Professional Documents
Culture Documents
RFC 2544 Ethernet Test Report
RFC 2544 Ethernet Test Report
Customer RIAU-SDI-2018002953
Technician IBNU-DONI
Location SDI-RIAU
Comments RFC@OK
Date Mar-22-22
Time Start 22:37:17
Time End 23:00:53
RFC 2544 Mode Symmetric
Test Instrument Name HST-3000 ACE II
Serial Number 667a2e010000
Software Revision 7.30.12
1 of 8
RFC 2544 Ethernet Test Report
2 of 8
RFC 2544 Ethernet Test Report
Throughput
8
Throughput (Mbps)
5.907 6.114
6
2.215
2 1.810
0.500 0.701
0.402
0
66 128 256 512 1024 1280 1518
Frame Length (Bytes)
3 of 8
RFC 2544 Ethernet Test Report
Latency (RTD)
20000
16879
Latency (RTD) (us)
10000
5000
0
66 128 256 512 1024 1280 1518
Frame Length (Bytes)
4 of 8
RFC 2544 Ethernet Test Report
60%
Frame Loss Rate (%)
50%
40%
30%
20%
10%
0%
0.0 20.0 40.0 60.0
Cfg Rate (Mbps)
5 of 8
RFC 2544 Ethernet Test Report
3%
Frame Loss Rate (%)
2.5%
2%
1.5%
1%
0.5%
0%
0.0 20.0 40.0 60.0
Cfg Rate (Mbps)
12%
Frame Loss Rate (%)
10%
8%
6%
4%
2%
0%
0.0 20.0 40.0 60.0
Cfg Rate (Mbps)
6 of 8
RFC 2544 Ethernet Test Report
Frame Loss 512 Bytes:
25%
Frame Loss Rate (%)
20%
15%
10%
5%
0%
0.0 20.0 40.0 60.0
Cfg Rate (Mbps)
25%
Frame Loss Rate (%)
20%
15%
10%
5%
0%
0.0 20.0 40.0 60.0
Cfg Rate (Mbps)
7 of 8
RFC 2544 Ethernet Test Report
Frame Loss 1280 Bytes:
16%
Frame Loss Rate (%)
14%
12%
10%
8%
6%
4%
2%
0%
0.0 20.0 40.0 60.0
Cfg Rate (Mbps)
35%
Frame Loss Rate (%)
30%
25%
20%
15%
10%
5%
0%
0.0 20.0 40.0 60.0
Cfg Rate (Mbps)
8 of 8