Professional Documents
Culture Documents
Juntion Box For Optimix 2000 - 12000
Juntion Box For Optimix 2000 - 12000
07:29:30
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Approved For Construction date of print: 24.09.2018
Customer: ##
Order: ¤¤
Project no.: ¤
Project: Real Equipment and Devices
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix 2000-12000 - Box 133106990 Project: Real Equipment and Devices Function Unit: <F.No>
Created: Laursen Optimix Project no.: ¤ Location:
Checked: Laursen / 21.09.2018 Cover sheet Customer: ## Page: 1 / 22 1 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
07:29:31
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|PAB.2 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
WARNING
DO NOT OPEN THIS JUNCTION BOX WHEN ENERGIZED
A A
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the
General Information
-These diagrams are shown with optional equipment that might not be installed at the current machine.
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those
However, the junction box does contain terminals and cable glands for all of these options.
-Only use qualified personnel for installation and maintenance of EX-equipment.
-Always comply with relevant national and international regulations.
-For EX-installations always comply with Directive 2014/34/EU, relevant parts of the IEC 60079 Standard series,
with special attention to IEC 60079-14:2013 and IEC 60079-18:2014.
-Always follow the installation instructions and all other relevant instructions published by the manufacturers.
For this junction box, these manufacturers are found in Order list and Parts list.
-Manufacturer instructions for external equipment must also be followed.
B B
Cable Glands
Cables
-Ensure proper PE-connection (both "inside" and "outside") of the junction box according to "Installation and Operating Instructions" for the cabinet.
Note: "Inside" PE conductor through cable gland "P-PE" must be connected at the same connection point as the factory pre-wired
PE-connection between cabinet interior and cabinet door.
expressly agreed to by ANDRITZ AG or one of its affiliates.
E E
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix 2000-12000 - Box 133106990 Project: Real Equipment and Devices Function Unit: <F.No>
Created: Laursen Optimix Project no.: ¤ Location:
Checked: Laursen / 21.09.2018 Information Customer: ## Page: 2 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|PAB.3
07:29:31
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy,
reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. Approved For Construction date of print: 24.09.2018
Pages
Label/
Created Checked Revision Document number Document number
Sheet number Unit / Location / Funct. Description 1 Description 2 Description 3 Status
Rev.
Description ANDRITZ customer
date by date by
Front matter
1 <F.No> / / Cover sheet Optimix 2000-12000 - Optimix 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
Box 133106990
2 <F.No> / / Information Optimix 2000-12000 - Optimix 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
Box 133106990
3 <F.No> / / Table of contents Optimix 2000-12000 - Optimix 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
Box 133106990
4 @MIX.ST1.01 / / Mixer Mixer boxes Optimix 2000-12000 - 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
Box 133106990
Loop diagrams
5 <F.No>.V1 / / DV Circuit diagram Optimix Inlet Damper 5/3 Lock Damper 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
6 <F.No>.V2 / / DV Circuit diagram Optimix Inlet Damper 5/2 Open/Close Damper 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
(A)
7 <F.No>.V3 / / DV Circuit diagram Optimix Inlet Damper 5/2 Open/Close Damper 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
(B)
8 <F.No>.G1 / / ZZ Circuit diagram Optimix Door Switch (A) [w/Lock] 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
9 <F.No>.S1 / / SZ Circuit diagram Optimix Zero Speed Monitoring 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
[Dual
sensor+Transmitter]
10 <F.No>.V1 / / DV Circuit diagram Optimix 3/2 Air Seal 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
11 <F.No>.V2 / / DV Circuit diagram Optimix 5/3 Lock Gate 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
12 <F.No>.V3 / / DV Circuit diagram Optimix 5/2 Open/Close Gate (A) 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
13 <F.No>.V4 / / DV Circuit diagram Optimix 5/2 Open/Close Gate (B) 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
Layout drawings
14 <F.No> / <F.No>-CB01 / Exterior design 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
15 <F.No> / <F.No>-CB01 / Interior design 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
Terminal diagrams
16 <F.No> / <F.No>-CB01 / Terminal diagram - X1 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
17 <F.No> / <F.No>-CB01 / Terminal diagram - X2 2 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
19 <F.No> / <F.No>-CB01 / Terminal diagram - X3 2 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
Lists
21 <F.No> / <F.No>-CB01 / Parts list 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
Lists
22 <F.No> / <F.No>-CB01 / Orderlist 1 21.09.2018 Laursen 0 21.09.2018 Laursen Created first revision Approved For Construction 18128
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix 2000-12000 - Box 133106990 Project: Real Equipment and Devices Function Unit: <F.No>
Created: Laursen Optimix Project no.: ¤ Location:
Checked: Laursen / 21.09.2018 Table of contents Customer: ## Page: 1 / 22 3 / 22
Standard: Order: ¤¤ Draw. no.: 18128
date of print:
07:29:35 24.09.2018 1 2 3 4 5 6 7 8 9
Important note:
This P&ID show only Junctionbox relevant functions.
A For full P&ID of machine, consult project documentation. A
[2C2FB]
DV
<F.No>.V2
[2C2FB]
DV
<F.No>.V1
Optimix 2000-4000
ZZ
<F.No>.G1
B B
[2C2FB]
SZ DV
<F.No>.S1 <F.No>.V2
[1C0FB] [2C2FB]
DV DV
<F.No>.V1 <F.No>.V3
C C
ZZ
<F.No>.G1
D D
SZ [2C2FB]
DV
<F.No>.S1
<F.No>.V2
[2C2FB]
DV
<F.No>.V3
[1C0FB]
DV [2C2FB]
DV
<F.No>.V1
<F.No>.V4
E E
[2C2FB] [2C2FB]
Optimix 10000-12000 DV DV
<F.No>.V2 <F.No>.V3
[2C2FB]
DV
<F.No>.V1
ZZ
F F
<F.No>.G1
Revisions
Revisions
checked
Rev. Date Name Quadrant, Description Date Name
Drawn by 21.09.2018 Laursen Ref. doc. no.
SZ [2C2FB] 21.09.2018 Laursen
DV Checked Replaces
<F.No>.S1
<F.No>.V2 Reference Model No.
@MIX.ST1.01
Rel. Label Customer doc. no.
[2C2FB]
DV Scale Document Title Document no. Rev. Lang. Sheet
<F.No>.V3
[1C0FB] Mixer 4
DV
DV
[2C2FB] 18128 0 EN of
G <F.No>.V1
<F.No>.V4 Mixer boxes 22 G
CAE 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ
Optimix 2000-12000 - Box 133106990 @MIX|ST1|01|JPID.4
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party
Project: Project no.: Customer: Order:
Document number: Rev.: accepting receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, Real Equipment and Devices ¤ ## ¤¤
disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or
18128 0 one of its affiliates. ## Group No.
1 2 3 4 5 6 7 8 9
07:29:37
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|020|V1|E|PFSS.5 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
DO1 DO2
Lock Damper - Command Open Lock Damper - Command Close Lock Damper - Feedback Opened Lock Damper - Feedback Closed
Command Lock Command Unlock
Optimix Inlet Damper - 5/3 Optimix Inlet Damper - 5/3
DO1 digital DO2 digital DI1 DI2
Lock Damper - Command Open Lock Damper - Command Close
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those
?
COM
+
S
?
-
-
-
-
-
-
IN
IN
COM
COM
VDC
VDC
+24 VDC
+24 VDC
-
-
?
COM
S
B B
1 2 3 4 5 6 7 8
<F.No>.V1-W1
12 x 1
-CB01
C C
5a
5b
PEPE
PEPE
C-OPTIMIX - Box 133106990
1b
1a
2a
2b
3b
4b
<F.No>-X3
3a
4a
GNYE
GNYE
BU
BN
BU
BN
BK
BK
2
2
expressly agreed to by ANDRITZ AG or one of its affiliates.
-
-
-
-
-
-
contact contact
D 4 2 <F.No>.V1-GSO <F.No>.V1-GSC
D
S
+
+
-
-
A1 B1 Limit Switch Limit Switch
PARKER PARKER
Y1 Y2 P8S-GSFTX P8S-GSFTX
A2 5 1 3 B2
G G
PARKER
P2LBX612EENDDB49
<F.No>.V1-P
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix Inlet Damper Project: Real Equipment and Devices Function Unit: <F.No>.V1
Created: Laursen 5/3 Lock Damper Project no.: ¤ DV Location:
Checked: Laursen / 21.09.2018 AEI - v3.1 - Circuit diagram Customer: ## Page: 5 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
07:29:40
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|020|V2|E|PFSS.6 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
DO1 DO2
Open/Close Damper (A) - Command Open Open/Close Damper (A) - Command Close Open/Close Damper (A) - Feedback Opened Open/Close Damper (A) - Feedback Closed
Command Open Command Close
Optimix Inlet Damper - 5/2 Optimix Inlet Damper - 5/2
DO1 digital DO2 digital DI1 DI2
Open/Close Damper (A) - Command Open Open/Close Damper (A) - Command Close
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those
?
COM
+
S
?
-
-
-
-
-
-
IN
IN
COM
COM
VDC
VDC
+24 VDC
+24 VDC
-
-
?
COM
S
B B
1 2 3 4 5 6 7 8
<F.No>.V2-W1
12 x 1
-CB01
10a
10b
C C
PEPE
PEPE
C-OPTIMIX - Box 133106990
6b
6a
7a
7b
8b
9b
<F.No>-X3
8a
9a
GNYE
GNYE
BU
BN
BU
BN
BK
BK
2
2
expressly agreed to by ANDRITZ AG or one of its affiliates.
-
-
-
-
-
-
contact contact
D 4 2 <F.No>.V2-GSO <F.No>.V2-GSC
D
S
+
+
-
-
A1 B1 Limit Switch Limit Switch
PARKER PARKER
Y1 Y2 P8S-GSFTX P8S-GSFTX
A2 5 1 3 B2
G G
PARKER
P2LBX51_EENDDB49
<F.No>.V2-P
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix Inlet Damper Project: Real Equipment and Devices Function Unit: <F.No>.V2
Created: Laursen 5/2 Open/Close Damper (A) Project no.: ¤ DV Location:
Checked: Laursen / 21.09.2018 AEI - v3.1 - Circuit diagram Customer: ## Page: 6 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
07:29:42
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|020|V3|E|PFSS.7 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
DO1 DO2
Open/Close Damper (B) - Command Open Open/Close Damper (B) - Command Close Open/Close Damper (B) - Feedback Opened Open/Close Damper (B) - Feedback Closed
Command Open Command Close
Optimix Inlet Damper - 5/2 Optimix Inlet Damper - 5/2
DO1 digital DO2 digital DI1 DI2
Open/Close Damper (B) - Command Open Open/Close Damper (B) - Command Close
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those
?
COM
+
S
?
-
-
-
-
-
-
IN
IN
COM
COM
VDC
VDC
+24 VDC
+24 VDC
-
-
?
COM
S
B B
2 1 3 4 7 6 5 8
<F.No>.V3-W1
12 x 1
-CB01
15a
15b
C C
PEPE
PEPE
C-OPTIMIX - Box 133106990
11b
11a
12a
12b
13b
14b
<F.No>-X3
13a
14a
GNYE
GNYE
BU
BN
BU
BN
BK
BK
2
2
expressly agreed to by ANDRITZ AG or one of its affiliates.
-
-
-
-
-
-
contact contact
D 4 2 <F.No>.V3-GSO <F.No>.V3-GSC
D
S
+
+
-
-
A1 B1 Limit Switch Limit Switch
PARKER PARKER
Y1 Y2 P8S-GSFTX P8S-GSFTX
A2 5 1 3 B2
G G
PARKER
P2LCX513EENDDB49
<F.No>.V3-P
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix Inlet Damper Project: Real Equipment and Devices Function Unit: <F.No>.V3
Created: Laursen 5/2 Open/Close Damper (B) Project no.: ¤ DV Location:
Checked: Laursen / 21.09.2018 AEI - v3.1 - Circuit diagram Customer: ## Page: 7 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
07:29:44
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|G1|E|PFSS.8 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
Optimix - Door Switch (A)
[w/Lock] - Feedback
DI1
Feedback
digital Input
A A
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those
-
-
-
IN
1 COM
VDC
2
<F.No>.G1-W1
-
4x1
+MCC
<F.No>.G1-X
(See MCC documentation) . . . . . . . . . .
B Safety Circuit [Stop Motor] B
.
.
.
.
.
.
.
.
NC
COM
.
.
.
.
.
.
.
.
.
.
. . . . . . . . . .
1
2
3
4
<F.No>.G1-W2
5x1
-CB01
C-OPTIMIX - Box 133106990
C C
7a
8a
9a
-X1:5a <F.No>-X1
(<F.No>.S1/9.4)
10a
10b
11a
11b
7b
8b
-X1:1b <F.No>-X1
(<F.No>.S1/9.3)
expressly agreed to by ANDRITZ AG or one of its affiliates.
2
3
<F.No>.G1-W4
2
1
3
4
5
6
-
4x1 <F.No>.G1-W3
-
D 7x1 D
<F.No>.G1-PB1-S1 X1 13
<F.No>.G1-GZ1
A1 A2 63 64 51 52 71 72 13 14 21 22 41 42
SCHMERSAL
SCHNEIDER ELECTRIC AZM 161SK-12/12RK-024
X2 14
ZB5AW333 + ZALVB3
Green
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix Project: Real Equipment and Devices Function Unit: <F.No>.G1
Created: Laursen Door Switch (A) [w/Lock] Project no.: ¤ ZZ Location:
Checked: Laursen / 21.09.2018 AEI - v3.1 - Circuit diagram Customer: ## Page: 8 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
07:29:46
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|S1|E|PFSS.9 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
Optimix - Zero Speed Monitoring
[Dual sensor+Transmitter] - Feedback
DI1
Feedback
digital Input
A A
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the
express understanding and agreement that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those
-
-
-
IN
COM
VDC
24VDC +
-
B 2 1 1 2
B
<F.No>.S1-W1 <F.No>.S1-W2
4x1 4x1
-CB01
1b
C-OPTIMIX - Box 133106990 <F.No>-X1 -X1:7b (<F.No>.G1/8.3)
-X1:7a (<F.No>.G1/8.2)
1a
2a
5a
6a
6b
<F.No>-CB01-ST
L- Y2 L+ 13 14 23 24 Y4 Y5 Y6 Y7
IFM
DA102S
C C
A1 Supply C1 Relay1 C2 Relay2 A2
A3 Pulse Input
Input 1 Input2
S33 S34 S43 S44
3a
3b
2b
4a
4b
5b
expressly agreed to by ANDRITZ AG or one of its affiliates.
<F.No>-X1 <F.No>-X1
BN BK BU BN BK BU
<F.No>.S1-W3 <F.No>.S1-W4
D original cable original cable
D
1
2
3
1
2
3
Impulse Impulse
<F.No>.S1-SE1 <F.No>.S1-SE2
S
S
+
+
-
IFM IFM
IF503A IF503A
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix Project: Real Equipment and Devices Function Unit: <F.No>.S1
Created: Laursen Zero Speed Monitoring [Dual sensor+Transmitter] Project no.: ¤ SZ Location:
Checked: Laursen / 21.09.2018 AEI - v3.2 - Circuit diagram Customer: ## Page: 9 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
07:29:48
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|V1|E|PFSS.10 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
A Optimix - 3/2 Air Seal - Optimix - 3/2 Air Seal - Optimix - 3/2 Air Seal - A
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the
-
COM
S
+24 VDC
B B
1
<F.No>.V1-W1
-
4x1
-CB01
C C
C-OPTIMIX - Box 133106990 PEPE
1b
1a
<F.No>-X2
GNYE
2
1
expressly agreed to by ANDRITZ AG or one of its affiliates.
<F.No>.V1-W2
-
4x1
D 2
D
A1
Y1
A2 1 3
OPTION!
PARKER
P2LAX311ESNDDB49
<F.No>.V1-P
Present on Optimix 2000-12000
E E
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix Project: Real Equipment and Devices Function Unit: <F.No>.V1
Created: Laursen 3/2 Air Seal Project no.: ¤ DV Location:
Checked: Laursen / 21.09.2018 AEI - v3.1 - Circuit diagram Customer: ## Page: 10 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
07:29:49
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|V2|E|PFSS.11 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
A Optimix - 5/3 Lock Gate - Optimix - 5/3 Lock Gate - Optimix - 5/3 Lock Gate - Optimix - 5/3 Lock Gate - Optimix - 5/3 Lock Gate - Optimix - 5/3 Lock Gate - Optimix - 5/3 Lock Gate - Optimix - 5/3 Lock Gate - A
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the
Command Open Command Open Command Open Command Close Command Close Command Close Feedback Opened Feedback Closed
Command Lock Command Lock Command Lock Command Unlock Command Unlock Command Unlock Feedback Locked Feedback Unlocked
digital digital digital digital digital digital digital Input digital Input
?
?
-
-
-
-
-
-
-
IN
IN
COM
COM
COM
COM
+
VDC
VDC
S
S
+24 VDC
+24 VDC
B B
2 1 3 4 7 6 5 8
<F.No>.V2-W1
12 x 1
-CB01
C C
6a
6b
PEPE
PEPE
C-OPTIMIX - Box 133106990
2b
2a
3a
3b
4b
5b
<F.No>-X2
4a
5a
GNYE
GNYE
BU
BN
BU
BN
BK
BK
2
2
expressly agreed to by ANDRITZ AG or one of its affiliates.
-
-
-
-
-
-
contact contact
D 4 2 <F.No>.V2-GSO <F.No>.V2-GSC
D
S
+
+
-
-
A1 B1 Limit Switch Limit Switch
PARKER PARKER
Y1 Y2 P8S-GSFTX P8S-GSFTX
A2 5 1 3 B2
G G
PARKER
P2LBX612EENDDB49
<F.No>.V2-P
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix Project: Real Equipment and Devices Function Unit: <F.No>.V2
Created: Laursen 5/3 Lock Gate Project no.: ¤ DV Location:
Checked: Laursen / 21.09.2018 AEI - v3.1 - Circuit diagram Customer: ## Page: 11 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
07:29:51
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|V3|E|PFSS.12 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
A Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close A
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the
Gate (A) - Command Open Gate (A) - Command Open Gate (A) - Command Open Gate (A) - Command Close Gate (A) - Command Close Gate (A) - Command Close Gate (A) - Feedback Opened Gate (A) - Feedback Closed
Command Open Command Open Command Open Command Close Command Close Command Close Feedback Opened Feedback Closed
digital digital digital digital digital digital digital Input digital Input
?
?
-
-
-
-
-
-
-
IN
IN
COM
COM
COM
COM
+
VDC
VDC
S
S
+24 VDC
+24 VDC
B B
2 1 3 4 7 6 5 8
<F.No>.V3-W1
12 x 1
-CB01
11a
11b
C C
PEPE
PEPE
C-OPTIMIX - Box 133106990
10b
7b
7a
8a
8b
9b
<F.No>-X2
10a
9a
GNYE
GNYE
BU
BN
BU
BN
BK
BK
2
2
expressly agreed to by ANDRITZ AG or one of its affiliates.
-
-
-
-
-
-
contact contact
D 4 2 <F.No>.V3-GSO <F.No>.V3-GSC
D
S
+
+
-
-
A1 B1 Limit Switch Limit Switch
PARKER PARKER
Y1 Y2 P8S-GSFTX P8S-GSFTX
A2 5 1 3 B2
G G
PARKER
P2LBX512EENDDB49
<F.No>.V3-P
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix Project: Real Equipment and Devices Function Unit: <F.No>.V3
Created: Laursen 5/2 Open/Close Gate (A) Project no.: ¤ DV Location:
Checked: Laursen / 21.09.2018 AEI - v3.1 - Circuit diagram Customer: ## Page: 12 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
07:29:54
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|V4|E|PFSS.13 Approved For Construction date of print: 24.09.2018
1 2 3 4 5 6 7
A Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close Optimix - 5/2 Open/Close A
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the
Gate (B) - Command Open Gate (B) - Command Open Gate (B) - Command Open Gate (B) - Command Close Gate (B) - Command Close Gate (B) - Command Close Gate (B) - Feedback Opened Gate (B) - Feedback Closed
Command Open Command Open Command Open Command Close Command Close Command Close Feedback Opened Feedback Closed
digital digital digital digital digital digital digital Input digital Input
?
?
-
-
-
-
-
-
-
IN
IN
COM
COM
COM
COM
+
VDC
VDC
S
S
+24 VDC
+24 VDC
B B
2 1 3 4 7 6 5 8
<F.No>.V4-W1
12 x 1
-CB01
16a
16b
C C
PEPE
PEPE
C-OPTIMIX - Box 133106990
12b
12a
13a
13b
14b
15b
<F.No>-X2
14a
15a
GNYE
GNYE
BU
BN
BU
BN
BK
BK
2
2
expressly agreed to by ANDRITZ AG or one of its affiliates.
-
-
-
-
-
-
contact contact
D 4 2 <F.No>.V4-GSO <F.No>.V4-GSC
D
S
+
+
-
-
A1 B1 Limit Switch Limit Switch
PARKER PARKER
Y1 Y2 P8S-GSFTX P8S-GSFTX
A2 5 1 3 B2
G G
PARKER
P2LBX512EENDDB49
<F.No>.V4-P
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Optimix Project: Real Equipment and Devices Function Unit: <F.No>.V4
Created: Laursen 5/2 Open/Close Gate (B) Project no.: ¤ DV Location:
Checked: Laursen / 21.09.2018 AEI - v3.1 - Circuit diagram Customer: ## Page: 13 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
1 2 3 4 5 6 7
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|0|PED.14 Approved For Construction date of print: 24.09.2018
07:29:57
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
300
300
M20
K2 JACOB PERFECT M 16x1,5 (5 - 9mm) V1-W1 Optimix
155
M16 M16 M16 M16 M16 M16 M16 M20 M20 M20 M12
5
L2 JACOB PERFECT M 16x1,5 (5 - 9mm) S1-W2 Optimix
25 30 30 30 30 30 30 30 15 35 35 35 25
L5 JACOB PERFECT M 12 x 1,5 (3 - 6mm) P-PE Grounding
380
All measures in mm
M=1:5
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Project: Real Equipment and Devices Function
Unit: <F.No>
Created: Laursen Project no.: ¤ Location: <F.No>-CB01
Checked: Laursen / 21.09.2018 Layout drawings - Exterior design Customer: ## Page: 14 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|0|PED.15 Approved For Construction date of print: 24.09.2018
07:30:03
third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
receipt of this drawing does so on the express understanding and agreement that it will neither copy, reproduce, disclose to
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting
335
279,5
245
25
90
45
-X3
255
25
275
-ST
90
45
-X1
-X2
25
20
CABLE ENTRANCE
All measures in mm
M=1:2
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Project: Real Equipment and Devices Function
Unit: <F.No>
Created: Laursen Project no.: ¤ Location: <F.No>-CB01
Checked: Laursen / 21.09.2018 Layout drawings - Interior design Customer: ## Page: 15 / 22
Standard: EN 60617 Order: ¤¤ Draw. no.: 18128
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|10|X1|ET-KLP.16
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES : @MIX|ST1|01|030|CB01|10|X1|ET-KLP.16
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement 07:30:07
that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
Approved For Construction date of print: 24.09.2018
Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket
<F.No>.G1-W4, - 4 x 1
<F.No>.G1-W3, - 7 x 1
<F.No>.G1-W2, 5 x 1
<F.No>.S1-W1, 4 x 1
<F.No>.S1-W2, 4 x 1
Terminal strip
Manufacturer: PHOENIX CONTACT
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Project: Real Equipment and Devices Function Unit: <F.No>
Created: Laursen Project no.: ¤ Location: <F.No>-CB01
Checked: Laursen / 21.09.2018 Terminals - Terminal diagram Customer: ## Page: 1 / 22 16 / 22
Standard: Order: ¤¤ Draw. no.: 18128
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|10|X2|ET-KLP.17
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES : @MIX|ST1|01|030|CB01|10|X2|ET-KLP.17
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement 07:30:09
that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
Approved For Construction date of print: 24.09.2018
Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket
<F.No>.V1-W2, - 4 x 1
<F.No>.V2-W2, - 4 x 1
<F.No>.V2-W3, - 4 x 1
<F.No>.V3-W2, - 4 x 1
<F.No>.V3-W3, - 4 x 1
<F.No>.V2-W1, 12 x 1
<F.No>.V3-W1, 12 x 1
Terminal strip
Manufacturer: PHOENIX CONTACT
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Project: Real Equipment and Devices Function Unit: <F.No>
Created: Laursen Project no.: ¤ Location: <F.No>-CB01
Checked: Laursen / 21.09.2018 Terminals - Terminal diagram Customer: ## Page: 1 / 22 17 / 22
Standard: Order: ¤¤ Draw. no.: 18128
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|10|X2|ET-KLP.17
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES : @MIX|ST1|01|030|CB01|10|X2|ET-KLP.17
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement 07:30:09
that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
Approved For Construction date of print: 24.09.2018
Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket
<F.No>.V4-W3, - 4 x 1
<F.No>.V3-W1, 12 x 1
<F.No>.V4-W1, 12 x 1
Terminal strip
Manufacturer: PHOENIX CONTACT
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Project: Real Equipment and Devices Function Unit: <F.No>
Created: Laursen Project no.: ¤ Location: <F.No>-CB01
Checked: Laursen / 21.09.2018 Terminals - Terminal diagram Customer: ## Page: 2 / 22 18 / 22
Standard: Order: ¤¤ Draw. no.: 18128
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|10|X3|ET-KLP.19
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES : @MIX|ST1|01|030|CB01|10|X3|ET-KLP.19
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement 07:30:13
that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
Approved For Construction date of print: 24.09.2018
Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket
<F.No>.V1-W3, - 4 x 1
<F.No>.V2-W2, - 4 x 1
<F.No>.V2-W3, - 4 x 1
<F.No>.V1-W1, 12 x 1
<F.No>.V2-W1, 12 x 1
Terminal strip
Manufacturer: PHOENIX CONTACT
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Project: Real Equipment and Devices Function Unit: <F.No>
Created: Laursen Project no.: ¤ Location: <F.No>-CB01
Checked: Laursen / 21.09.2018 Terminals - Terminal diagram Customer: ## Page: 1 / 22 19 / 22
Standard: Order: ¤¤ Draw. no.: 18128
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|10|X3|ET-KLP.19
CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES : @MIX|ST1|01|030|CB01|10|X3|ET-KLP.19
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement 07:30:13
that it will neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates.
Approved For Construction date of print: 24.09.2018
Legend
Connection input-output: Bridges:
Connection / Bridge GND Terminal Ridge bridge
Diode Opto-coupler terminal Switch bridge
Disconnect terminal Resistor Connections I / O:
Fuse Slide connection Wire-Connection
Fuse, switchable Test socket
<F.No>.V3-W3, - 4 x 1
<F.No>.V3-W1, 12 x 1
Terminal strip
Manufacturer: PHOENIX CONTACT
Rev. Rev.Date Created Checked Description of Revision Crea.Date: 21.09.2018 Project: Real Equipment and Devices Function Unit: <F.No>
Created: Laursen Project no.: ¤ Location: <F.No>-CB01
Checked: Laursen / 21.09.2018 Terminals - Terminal diagram Customer: ## Page: 2 / 22 20 / 22
Standard: Order: ¤¤ Draw. no.: 18128
07:30:16
This document constitutes confidential and proprietary information of ANDRITZ AG and/or its affiliates. Any party accepting receipt of this drawing does so on the express understanding and agreement that it will
neither copy, reproduce, disclose to third parties or use this document for any purpose other than those expressly agreed to by ANDRITZ AG or one of its affiliates. CAE: 0_3_AFB_REAL_EQUIPMENT_AND_DEVICES/GRZ:@MIX|ST1|01|030|CB01|91|ET-PAR.21
Date of print: 24.09.2018
Project name: Real Equipment and Devices Parts list
Project number: ¤ Doc. no.: 18128 for
Project description: # Plant Type - Feed - Pet- Bio Plant Status: Approved For Construction @MIX.ST1.01 / Optimix 2000-12000 - Box 133106990
Customer: ## Customer
Customer project no.: ¤¤ doc. no.:
Rev.
Unit Location Label Page Path Description Manufacturer Type Part number Remark
Rev.
Pcs. Manufacturer Description Type Part number SAP mat. number Remark