Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 12

PROJECT ESCALADES (TOWER 1)

SUBJECT STRIP FOOTING


DESIGNER
DATE 7/21/2022 9:28

The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 2015 7th Edition Section 415.3.2

Footing Name STF1

Allowable Soil Bearing Capacity 4000 psf

Design Service load 1930 kip

The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load

Foundation Weight 193 kip

Total Load 2123 kip

The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure

Required Area 530.75 sqft

Adopted Dimensions of Footing


WIDTH 13.12 ft 4 meter
LENGTH 41.656 ft 12.7 meter

Actual Footing Area 546.53 sqft


Actual Soil Pressure 3884.53 psf

For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered

Reinforcement Along Ftg Width Reinforcement Along Ftg Length


Column 1 Column 2
Column Width 20 in Column Width 20 in
Column Length 24 in Column Length 24 in
Dist. b/w Col 16.43 ft Dist. b/w Col 16.43 ft
Cant. Length 5.560 ft Cant. Length 2 ft
Moment(Cant.) 93.07 kip-ft/ft Moment(Cant) 10.811 kip-ft/ft
Moment(b/w Col) 203.24 kip-ft/ft
Des. Mu= 203.24 kip-ft/ft

r 0.0025
F'c 4000 psi
Fy 60000 psi
Rn 146.69 psi
Ftg. Thk. 42.24 in

Trial Ftg. Thk. 43 in Trial Ftg. Thk. 43 in


As_bot 49.99 sqin As_bot 15.74 sqin

Rebar dia 32 mm Rebar dia 32 mm


Rebar area 1.247 sqin Rebar area 1.247 sqin
No. Rebar 41 pcs. No. Rebar 13 pcs.
END
Reinforcement Along Ftg Length
Column 3
Column Width 20 in
Column Length 24 in
Dist. b/w Col 16.43 ft
Project: Norde Building
Location : 100 Kalayaan Ave. Central, Quezon City

Title NORDE Des by JCEN Date 91312

Mark MAT(ELEVATOR) Chck by Date

MAT FOUNDATION
The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2

Allowable Soil Bearing Capacity 6000 psf

Design Service load 1700 kip

Actual Mat Area 38.28 sq. m

The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load

Foundation Weight 170 kip

Total Load 1870 kip

The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure

Required Area 311.67 sq ft

Check actual soil pressure

Actual Soil Pressure 4540.69 psf > Allowable Soil Bearing Capacity

For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered

Simply Supported Length Cantilever Length


L 3.40 m L 1.85 m
L 11.15 ft L 6.07 ft
Moment 109.41 kip-ft/ft Moment 129.57 kip-ft/ft
Des. Mu 129.57 kip-ft/ft

r 0.0034
F'c 4000 psi
Fy 60000 psi
Rn 197.88 psi
Ftg. Thk. 29.97 in

Adopt Ftg. Thk. 30 in


Ftg. Thk. 750 mm
As 1.10 sqin
Rebar dia 28 mm S 10.40
Area of Bar 0.954 sqin say 10 in
Spacing 250 mm

Adopt Dia. 28 mm spaced @ 250 mm


END
Project: Design and Construct 100 MLD North STP
Location : Kabayani Marikina City

CHLORINATION
Title TANK Des by TCP Date 81911

Mark MF1 Chck by Date

MAT FOUNDATION
The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2

Allowable Soil Bearing Capacity 3000 psf

Design Service load 4520 kip

Actual Mat Area 114.8 sq. m

The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load

Foundation Weight 452 kip

Total Load 4972 kip

The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure

Required Area 1657.33 sq ft

Check actual soil pressure

Actual Soil Pressure 4025.70 psf > Allowable Soil Bearing Capacity

For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered

Simply Supported Length Cantilever Length


L 1.92 m L 2.00 m
L 6.28 ft L 6.56 ft
Moment 30.77 kip-ft/ft Moment 134.26 kip-ft/ft
Des. Mu 134.26 kip-ft/ft

r 0.0025
F'c 4000 psi
Fy 60000 psi
Rn 146.69 psi
Ftg. Thk. 34.89 in

Adopt Ftg. Thk. 36 in


Ftg. Thk. 900 mm
As 0.99 sqin
Rebar dia 25 mm S 9.22
Area of Bar 0.761 sqin say 8 in
Spacing 200 mm

Adopt Dia. 25 mm spaced @ 200 mm


END
PROJECT ESCALADES (TOWER 1)
SUBJECT ISOLATED FOOTING DESIGN
DESIGNER
DATE 7/21/2022 9:28

The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 2015 7th Edition Section 415.3.2

Footing Name F1

Allowable Soil Bearing Capacity 4000 psf

Design Service load 660 kip

The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load

Foundation Weight 66 kip

Total Load 726 kip

The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure

Required Area 181.50 sqft

Adopted Dimensions of Footing


WIDTH 13.78 ft 4.2 meter
LENGTH 14.432 ft 4.4 meter

Actual Footing Area 198.82 sqft


Actual Soil Pressure 3651.63 psf

For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered

Reinforcement Along Ftg Width Reinforcement Along Ftg Length


Column Dim. 20 in Column Dim. 24 in
Cant. Length 6.05 ft Cant. Length 6.22 ft
Moment 103.75 kip-ft/ft Moment 109.35 kip-ft/ft
Des. Mu 109.35 kip-ft/ft

r 0.0030
F'c 4000 psi
Fy 60000 psi
Rn 175.24 psi
Ftg. Thk. 29.33 in

Adopt Ftg. Thk. 30 in Trial Ftg. Thk. 30 in


As_bot 14.03 sqin As_bot 13.39 sqin

Rebar dia 28 mm Rebar dia 28 mm


Rebar area 0.954 sqin Rebar area 0.954 sqin
No. Rebar 15 pcs. No. Rebar 15 pcs.

END
PROJECT ESCALADES (TOWER 1)
SUBJECT ISOLATED FOOTING DESIGN
DESIGNER
DATE 7/21/2022 9:28

The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2

Footing Name F2

Allowable Soil Bearing Capacity 4000 psf

Design Service load 250 kip

The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load

Foundation Weight 25 kip

Total Load 275 kip

The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure

Required Area 68.75 sqft

Adopted Dimensions of Footing


WIDTH 5.904 ft 1.8 meter
LENGTH 9.84 ft 3 meter

Actual Footing Area 58.10 sqft


Actual Soil Pressure 4733.60 psf

For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered

Reinforcement Along Ftg Width Reinforcement Along Ftg Length


Column Dim. 20 in Column Dim. 20 in
Cant. Length 4.237 ft Cant. Length 4.087 ft
Moment 65.87 kip-ft/ft Moment 61.27 kip-ft/ft
Des. Mu 65.87 kip-ft/ft

r 0.0025
F'c 4000 psi
Fy 60000 psi
Rn 146.69 psi
Ftg. Thk. 25.34 in

Trial Ftg. Thk. 26 in Trial Ftg. Thk. 26 in


As_bot 6.79 sqin As_bot 4.07 sqin

Rebar dia 20 mm Rebar dia 20 mm


Rebar area 0.487 sqin Rebar area 0.487 sqin
No. Rebar 14 pcs. No. Rebar 9 pcs.

END
PROJECT EURO PLAZA
SUBJECT ISOLATED FOOTING DESIGN
DESIGNER FERDY
DATE 7/21/2022 9:28

The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2

Footing Name F-4

Allowable Soil Bearing Capacity 5000 psf

Design Service load 134 kip

The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load

Foundation Weight 13.4 kip

Total Load 147.4 kip

The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure

Required Area 29.48 sqft

Adopted Dimensions of Footing


WIDTH 5.576 ft 1.7 meter
LENGTH 5.576 ft 1.7 meter

Actual Footing Area 31.09 sqft


Actual Soil Pressure 4740.80 psf

For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered

Reinforcement Along Ftg Width Reinforcement Along Ftg Length


Column Dim. 20 in Column Dim. 20 in
Cant. Length 3.909 ft Cant. Length 3.909 ft
Moment 56.15 kip-ft/ft Moment 56.15 kip-ft/ft
Des. Mu 56.15 kip-ft/ft

r 0.0020
F'c 4000 psi
Fy 60000 psi
Rn 117.88 psi
Ftg. Thk. 26.01 in

Trial Ftg. Thk. 26 in Trial Ftg. Thk. 26 in


As_bot 3.08 sqin As_bot 3.08 sqin

Rebar dia 20 mm Rebar dia 20 mm


Rebar area 0.487 sqin Rebar area 0.487 sqin
No. Rebar 7 pcs. No. Rebar 7 pcs.

END
PROJECT
SUBJECT COMBINED FOOTING
DESIGNER
DATE 7/21/2022 9:28

The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2

Footing Name CF1

Allowable Soil Bearing Capacity 4000 psf

Design Service load 2000 kip

The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load

Foundation Weight 200 kip

Total Load 2200 kip

The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure

Required Area 550.00 sqft

Adopted Dimensions of Footing


WIDTH 14.76 ft 4.5 meter
LENGTH 29.52 ft 9 meter

Actual Footing Area 435.72 sqft


Actual Soil Pressure 5049.17 psf

For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered

Reinforcement Along Ftg Width Reinforcement Along Ftg Length


Column 1 Column 2
Column Width 20 in Column Width 20 in
Column Length 28 in Column Length 52 in
Dist. b/w Col 16.07 ft Dist. b/w Col 16.07 ft
Cant. Length 6.213 ft Cant. Length 5.057 ft
Moment(Cant.) 151.07 kip-ft/ft Moment(Cant) 100.084 kip-ft/ft
Moment(b/w Col) 252.70 kip-ft/ft
Des. Mu= 252.70 kip-ft/ft

r 0.0025
F'c 4000 psi
Fy 60000 psi
Rn 146.69 psi
Ftg. Thk. 46.75 in

Trial Ftg. Thk. 28 in Trial Ftg. Thk. 28 in


As_bot 22.14 sqin As_bot 11.07 sqin

Rebar dia 25 mm Rebar dia 25 mm


Rebar area 0.761 sqin Rebar area 0.761 sqin
No. Rebar 30 pcs. No. Rebar 15 pcs.
END