Professional Documents
Culture Documents
Foundation Design
Foundation Design
The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 2015 7th Edition Section 415.3.2
The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load
The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure
For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered
r 0.0025
F'c 4000 psi
Fy 60000 psi
Rn 146.69 psi
Ftg. Thk. 42.24 in
MAT FOUNDATION
The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2
The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load
The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure
Actual Soil Pressure 4540.69 psf > Allowable Soil Bearing Capacity
For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered
r 0.0034
F'c 4000 psi
Fy 60000 psi
Rn 197.88 psi
Ftg. Thk. 29.97 in
CHLORINATION
Title TANK Des by TCP Date 81911
MAT FOUNDATION
The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2
The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load
The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure
Actual Soil Pressure 4025.70 psf > Allowable Soil Bearing Capacity
For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered
r 0.0025
F'c 4000 psi
Fy 60000 psi
Rn 146.69 psi
Ftg. Thk. 34.89 in
The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 2015 7th Edition Section 415.3.2
Footing Name F1
The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load
The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure
For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered
r 0.0030
F'c 4000 psi
Fy 60000 psi
Rn 175.24 psi
Ftg. Thk. 29.33 in
END
PROJECT ESCALADES (TOWER 1)
SUBJECT ISOLATED FOOTING DESIGN
DESIGNER
DATE 7/21/2022 9:28
The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2
Footing Name F2
The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load
The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure
For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered
r 0.0025
F'c 4000 psi
Fy 60000 psi
Rn 146.69 psi
Ftg. Thk. 25.34 in
END
PROJECT EURO PLAZA
SUBJECT ISOLATED FOOTING DESIGN
DESIGNER FERDY
DATE 7/21/2022 9:28
The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2
The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load
The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure
For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered
r 0.0020
F'c 4000 psi
Fy 60000 psi
Rn 117.88 psi
Ftg. Thk. 26.01 in
END
PROJECT
SUBJECT COMBINED FOOTING
DESIGNER
DATE 7/21/2022 9:28
The design loads considered in the sizing of the footing are unfactored or service loads as
stated in the National Structural Code of the Philippines 5th Edition Section 415.3.2
The weight of the foundation to be added to the service load shall be at a maximum of 10%
of the load
The required area of footing shall be determined by dividing the total load by the allowable soil
bearing pressure
For the design of footing reinforcement, ultimate loads (1.4DL+1.7LL) or 1.55xActual Soil
Pressure shall be considered
r 0.0025
F'c 4000 psi
Fy 60000 psi
Rn 146.69 psi
Ftg. Thk. 46.75 in