Content

Chapter 1: Introduction ___________________________ 2


Chapter 2: General Description _____________________ 2
Chapter 3: Main Functions _________________________ 3
3.1 Alarms ___________________________________________________________________ 3
3.2 Diagnostics _______________________________________________________________ 3
3.3 Valve Control ______________________________________________________________ 3
3.3 Events Record _____________________________________________________________ 4
3.4 User interface______________________________________________________________ 4
3.4.1 LCD display ___________________________________________________________ 5
3.4.2 Button _______________________________________________________________ 7
3.4.3 Communication ________________________________________________________ 7

Chapter 4: Mechanical installation __________________ 8


4.1 Notes ____________________________________________________________________ 8
4.2 Mount ____________________________________________________________________ 8

Chapter 5: Technical Characteristics ________________ 9

Page 1
Installation and User Guide

Chapter 1: Introduction

Viewshine U-GR2 as a smart ultrasonic gas meter with GPRS wireless communication modules
and internal shutoff valve, and supporting IC pre-payment and different power supply styles brings
customers different configuration options at economical principle. In its extended measuring range of
0.016~6m3/h. U-GR2 keeps high level of accuracy for its very sensitive ultrasonic sensor. No-moving
parts, full electronic measurement and temperature compensation drive all combine to give long term
stability in this meter service life.

U-GR2 is available in different models with the following main common features:

 High Measurement Stability and Accuracy


 Temperature Compensation
 Internal Shut-off Valve
 Extended Measuring Range
 LCD display

This document refers to the version of U-GR2 and provides information about the use of the involved
device.

Chapter 2: General Description

Product Name:
Name Residential Ultrasonic Gas Meter

Model No.:
Code U-GR2

Identification of product:
Case
 Case LCD
Panel
 Panel Optical
 LCD Port Button
 Optical Port
 Button Battery
 Battery

Fig. 1

Page 2
VIEWSHINE

Residential Ultrasonic Gas Meter

Chapter 3: Main Functions

3.1 Alarms
With advantages of design and ultrasonic measurement technology, U-GR2 implements in particular
the following services of detecting and display:

 Low battery

 Reverse flow

 Leakage Detecting with displaying “Err-7”

 Overload Detecting with displaying “Err-8”

3.2 Diagnostics
U-GR2 implements in particular service of diagnostics and display:

 Pressure sensor failure with displaying “Err-0”

 Temperature sensor failure with displaying “Err-1”.

 Memory chip failure with displaying “Err-2”.

 Metering Module failure lasts for more than 1 hour with displaying “Err-9”

3.3 Valve Control


U-GR2 implements in particular service of valve control in the following cases:

 Low battery

 Metering module failure

 Reverse flow

 Memory chip failure

 Remote control command

 Leakage(Optional)

 Overload (Optional)

Page 3
Installation and User Guide

3.3 Events Record


U-GR2 implements in particular service of events as below:

CODE DESCRIPTION
01 Replace batteries
02 Low Battery
03 Overload
04 Overload disappears
05 Leakage
06 Leakage disappears
09 Clean Event Log
10 Temperature Sensor Failure
11 Pressure Sensor Failure
12 Temperature Sensor returns to normal
13 Pressure Sensor returns to normal
14 Reverse Flow
15 Reverse flow disappears
16 Metering Module Failure
17 Metering module returns to normal

Table 1

3.4 User interface


The user interface consists of LCD display, button. The following paragraphs describe the interaction
between the operator and the user interface, and the meaning of the various fields available on the
display.

Page 4
VIEWSHINE

Residential Ultrasonic Gas Meter

3.4.1 LCD display


The display is an LCD display that consists of 9 7-segment characters and a series of icons. The
meanings are described below.

Fig. 2

Units of measurement

UNIT DESCRIPTION
Media Temperature Unit

Media Pressure Unit

Flow Rate

Metrological Volume

Table 2

Icons and alarms

ICON DESCRIPTION

: ≥ 5.7V

: 5.1V~5.7V

: 4.9V~5.1V (Under voltage)

: <4.9V (Low voltage)

Test mode is on

Reverse flow is detected

Table 3

Note: other icons or characters in LCD display without description are reserved.

Page 5
Installation and User Guide

Display

Short-press (0.5s) button each time to switch LCD display, displays in turn as table below:

NO. NAME DISPLAY DESCRIPTION

1. Total Volume XXX.xxxx m³/h

First 6 digits of meter No-


2. Meter No.-Part 1
”HXXXXXX”

Last 6 digits of Meter No.-


3. Meter No.-Part 2
“LXXXXXX”

“csq--XX”
4. Signal Strength
“XX” is in range of 0~31

“tPE- X.X”
5. Meter Type
“X.X”=1.6/2.5/4.0

6. Date XXXXXX(yymmdd)

7. Time XX:XX:XX(hh:mm:ss)

Table 4

Page 6
VIEWSHINE

Residential Ultrasonic Gas Meter

3.4.2 Button

1) Short-press (0.5s) button each time to switch LCD display, see Table 4 “Display”

2) In the screen of “Time” long press for 3s to switch to engineering interface. Please note that this
function is designed for the configuration by the authorized person only.

3.4.3 Communication
U-GR-6 is compatible with two communication interfaces, a local one and a remote one.

Local interface:
Optical Port: It is designed for the factory configuration and requires an external optical probe.
The optical port is normally on if the battery voltage is higher than 3.6V .

Remote interface:
GPRS Module: it is used for the utility to collect and analyze data with SIM card.

U-GR2 with integrated GPRS module implements in remote services as below:

 Data transmission;

 Read status of valve

 Valve control

Page 7
Installation and User Guide

Chapter 4: Mechanical installation

4.1 Notes
1) Before installation, carefully check that liquid or particles are not in gas meter’s inlet and outlet.

2) It is better to install the gas meter downstream of valve in pipeline.

3) U-GR is precision instrument; please handle it gently to prevent shock and vibration.

4.2 Mount
1) Read 4.1 Notes thoroughly before mounting please.

2) Mount the gas meter horizontally (Thread pattern: M30*2). Ensure the arrow direction as same
as gas flow direction.

3) Make sure the gas meter is mounted under cool, dry and frost free conditions to avoid direct solar
radiation and rain.

4) After mounting, open the upstream valve, and light the gas appliance for a while. Check the
accumulated consumption volume, if the value increases, it means gas meter work well,
installation is completed!

Page 8
VIEWSHINE

Residential Ultrasonic Gas Meter

Chapter 5: Technical Characteristics

Range and Capacities


G1.6 G2.5 G4.0 G4.0+

Qmin 0.016 0.025 0.04 0.016

Qn 1.6 2.5 4.0 1.6/2/5/4.0

Qmax 2.5 4.0 6.0 6.0

Electrical

Battery 6.0V, Alkaline/3.6V/Li-Battery

Metrological

+ 2% / 3% in range Qmin≤Q<0.1Qmax
Accuracy
+ 1%/ 1.5% in range 0.1Qmax≤Q≤Qmax

Pressure Loss ﹤250Pa

Mechanical
Environmental
Indoor
Classification
Protection Class IP54/IP65

Medium Temperature -25~55℃

Storage Temperature -30~60℃

Pressure Range ≤10kpa /≤50kpa

Connection axis spacing 130mm

Dimension 220*102*152mm

VIEWSHINE
Building 6#, Moganshan Road 1418-41, Hangzhou, Zhejiang, P.R.C

T +86 (0)571 88179010-8001 F +86 (0)571 88179018

Email: sales@viewshine.com.cn