UBICACIÓN

A B C D E F G

795950
19

VERDE
AREA

ESCALA GRAFICA ESCALA 1/5000

N
0m 50 100 150 200 250

0m 1.0 2.0 3.0 4.0 6.0


1 R.R.Ø4"
R.R.Ø3 " 1
Ø2" Ø2"
Ø4
R.R.Ø3 " Ø2" Ø2" Ø2" Ø2" Ø2" Ø2"
R.R.Ø4"
Ø2" Ø2" LEYENDA
Ø3 Ø2 Ø2 R.R.Ø4"

Ø3"
R.R.Ø4" Ø2 Ø2 "

"
" Ø2"
Ø2

Ø2
" Ø2 Ø2

Ø2"
" SUM.Ø3"

Ø2"
" " "

Ø2"
Ø2" "

"
Ø2" Ø2 "

Ø2
Ø4

"
R.R.Ø3 " R.R.Ø2"

Ø2"
" Ø2"

Ø2

"
"
Ø2"
Ø2 Ø2

Ø2
Ø2
R.R.Ø4" Ø3 " " Ø2 Ø2" Ø2" Ø2"

Ø2"
"

Ø3"

Ø2"
R.R.Ø3 " "

Ø4"
" R.R.Ø3 " Ø2" Ø2" Ø2" Ø2" Ø2" Ø2" Ø2"
" R.R.Ø4" Ø3 Ø2

"
Ø4 Ø2"

Ø2
SUM.Ø3" R.R.Ø2" "

Ø2"
" "
Ø3 Ø2" Ø2"

Ø3"
Ø3"

Ø4"
"

Ø3"
Ø2
Ø3 R.R.Ø4"

Ø2"
"
Ø2"
Ø3"

Ø4"

"
"

Ø2"
Ø3
"

Ø4
Ø4
Ø4"

Ø2"
" Ø3" " Ø2

Ø3"
SH 052 Ø2 Ø2 Ø2" Ø Ø3

Ø4"
PÚBLICO " " 2 " SH 056 Ø2"

Ø2"
R.R.Ø4"

Ø4"

Ø4"

"
SUM.Ø3"

Ø4"

Ø2
Ø2" DISCP. PÚBLICO Ø4" Ø4"
SUM.Ø3" Ø2 Ø4 SSHH 057 SUM.Ø3"

Ø4"
NPT +4.60 DISCP.

"
Ø3"
SUM.Ø3" SSHH 054 " SSHH 055

Ø2"
Ø2
CONSULTORIO "

"
PÚBLICO

Ø4
SSHH 051 SSHH 053 ESCALERA 2 SUM.Ø3" Ø4 ESCALERA 1

Ø2"
PREESCOLAR PÚBLICO NPT +4.60

"
DE "

Ø2
PÚBLICO HOMBRE

Ø3"
PÚBLICO NPT +4.60 Ø3 MUJER

Ø4
Ø3"
Ø3 PEDIATRIA NPT +4.60 Ø3

Ø2"
HOMBRES " ESCALERA 2 NPT +4.60

"
" MUJER Ø3 "

Ø4"

Ø2"
NPT +4.60

Ø2"

Ø4"
Ø3"
NPT +4.60 " NPT +4.60
NPT +4.60

Ø2"

Ø4"

Ø2"

Ø3"

Ø2"
Ø2"
Ø4"
Ø2"
Ø4"

Ø2" Ø2" Ø2" Ø2" Ø2" Ø2" Ø2" Ø4" Ø4"

Ø4"
ESCALERA 2 R.R.Ø4"
Ø2 Ø2 Ø2 R.R.Ø3 " Ø4
" Ø2" "

Ø3"
"

Ø4"
"

Ø2"
Ø2" Ø

Ø3"

Ø3"

"
Ø2"
Ø2"

Ø2
Ø3

Ø2"
Ø2" Ø2" Ø2" 2" R.R.Ø3 " Ø2
" R.R.Ø3 "

Ø4
R.R.Ø3 " "

Ø2"
Ø4

"
Ø4
"

"

"
Ø3
Ø2

Ø2
" Ø4 Ø3

Ø3"

"
Ø4 "

Ø3
Ø4"
Ø2" Ø3 " Ø2" Ø2" " " Ø2" Ø2"
Ø4 Ø4 Ø3 R.C.Ø4"

Ø4"
Ø2 Ø2 " Ø2 Ø3 Ø3
Ø3 " " "

Ø2"
" " "
Ø4" Ø4" " Ø4" Ø4" Ø4" Ø4" Ø4" " Ø4" Ø4" Ø4" Ø4" Ø4" " " Ø3
R.C.Ø4"

Ø4
R.C.Ø4"

Ø4

Ø3"
"
"
Ø4" Ø4" Ø4"
Ø4
"

Ø4"
Ø4
"
NPT +4.60
CORREDOR
NPT +4.60 CORREDOR
PÚBLICO
PUBLICO NPT +4.60

Ø2"

Ø4"

Ø4"
R.C.Ø2"
Ø4" Ø4"

"
Ø4
SALA DE

Ø2"
ESPERA
NPT +4.60 Ø2
"

Ø2"
2 2
SH 059

"
Ø2
Ø2" Ø2" Ø2" Ø2"

Ø4"
Ø2"
Ø2" Ø2
R.C.Ø4" "

Ø2"
II.MM. Ø4" R.C.Ø4"
II.SS. Ø4" Ø4" Ø4" Ø4"
" Ø2 II.SS.
Ø4 " Ø4

Ø2"
" II.MM. II.TT

M.D. N° 01
M.V. N° 01 M.D.Cu N°01
Ø2"

B.D. Ø4" Ø2"


LL.V. Ø4" S.V. Ø4" B.D. Ø4"

"
Ø2
S.V. Ø4"

Ø2"
S.V. Ø4"
M.D. N° 01
B.D. Ø4" ATENCIÓN
S.V. Ø4" INTEGRAL M.V. N° 02 M.D. N° 02
ADULTO SALA DE S.V.Ø4" B.D. Ø6"
MAYOR/CONSEJERIA ESPERA S.V. Ø6"
Y PREV.
NPT +4.60
ENFERMEDADES
NO
TRANSMISIBLES
RECEPCIÓN NPT +4.60
TOMA DE DE REGISTRO
MUESTRAS MUESTRAS Y LABORATORIO

Ø4"
NPT +4.60 ENTREGA DE CLÍNICO
RESULTADOS NPT +4.59 SALA DE
NPT +4.60 ESPERA
Ø2"

Ø2"
NPT. +4.59

Ø2" Ø2"
Ø2
R.R.Ø2" "

Ø2"
Ø2" Ø2" Ø2" R.C.Ø3"

Ø2
Ø2" "
CONSULTORIO "
DE Ø2

Ø4"
Ø4 "
PREVENCION " " Ø2
Ø3"

DEL CANCER Ø2 2" Ø4


" Ø Ø4" Ø4"
NPT +4.60
Ø2"

Ø2"
SH 058 "
NPT +4.60 Ø2 DEPOSITO R.R.Ø4"
CORREDOR SH 060
R.C.Ø2" NPT +4.59
INTERNO NPT +4.59
Ø2" Ø2"
NPT +4.59

Ø4"
"
Ø4"

Ø2

"
Ø2
3 Ø2"
3

"
Ø2
PATIO

Ø2"
SALA DE
Ø4"
Ø2 "

"
Ø4
ESTIMULACIÓN R.C.Ø2" " Ø2
TEMPRANA Ø2" Ø2"

Ø2"
"

Ø2"
Ø4

"
Ø2

CORREDOR PSICOPROFILAXIS

Ø4"
CONSULTA NPT +4.60
EXTERNA
Ø3"

NPT +4.60
Ø4"

PLANIFICACIÓN
FAMILIAR
NPT +4.60

CORREDOR
INTERNO Ø2"
"
Ø2

NPT +4.59 Ø2" CORREDOR SALA DE Ø4


" EMITIDO PARA
Ø2"

"
CONSULTA ESTIMULACIÓN Ø4" Ø4" R01 20/06/2022 SP OP

Ø2
LABORATORIO Ø4" Ø4" R.C.Ø4"
TEMPRANA REVISION
DE EXTERNA Ø4
"

Ø2 " Ø2" Ø2" Ø2 Ø2"


Ø2

NPT +4.60 EMITIDO PARA


"

MICROBIOLOGÍA NPT +4.59

"
" "
Ø2

Ø2
R00 21/02/2022 REVISION Y SP OP
NPT +4.60
COMENTARIOS
Ø2"

Ø4"
REV DESCRIPCIÓN DE LA

"
Ø4"

Ø2
" FECHA REVISADO DIRECTOR
N.º REVISIÓN
Ø4
FECHA FIRMA

Ø4"
CLOSET "
II.EE.
Ø2" Ø2
SH 062 + DISEÑO :
Ø2" VESTIDOR
Ø2
"
ING. LUIS PEJERREY MINGUILLO 20/06/22

Ø2"
NPT +4.60

Ø4"
CONTROL DIBUJO :
Ø2"

PRENATAL 20/06/22
Ø3"

Ø2 R.R.Ø4" ING. LUIS PEJERREY MINGUILLO


" NPT +4.60 CLOSET
II.EE.
SALA DE REVISION :
ESCLUSA PROCEDIMIENTOS
GINECOLÓGICOS ARQ. SANDRA PAZ 20/06/22
NPT +4.60
Ø2 R.C.Ø4"
" NPT +4.59 APROBACION :

Ø4"
Ø2"

ING. OSWALDO PATIÑO 20/06/22


Ø2"

Ø4
Ø4"

"
Ø2" DIRECTOR DE PROYECTO :
Ø2" Ø2" Ø2" Ø2"
Ø2 ING. OSWALDO PATIÑO 20/06/22
Ø2" " Ø2" Ø2"
"
"

Ø2
Ø2

Ø4 Ø2
Ø2" " " "
Ø2
Ø4
" Ø4
" Ø4"
Ø2" Ø2" Ø4"
Ø2 CONSULTORIO

Ø2"
" R.R.Ø4"

"
Ø4
CRED
4 CLOSET
4

Ø2"
II.EE. NPT +4.60

Ø4"
"
Ø4
A B C D E F G

PLANTA NIVEL 02 - EP1-SECTOR A


ESC.: 1 : 50
ESPECIFICACIONES TÉCNICAS
LEYENDA
1. LA RED DE DESAGÜES, SERÁ INSTALADA CON TUBERÍA PVC-CP. SIMBOLOGIA DESCRIPCION

R
E
C
U
P
E
R
A
C
I
O
N
D
E
L
O
S
DE ACUERDO A LAS NORMAS TÉCNICAS PERUANAS N°399.003-2,002. TUBERÍA DE DESAGÜE, EMPOTRADA O ENTERRADA
TUBERÍA DE DESAGÜE, COLGADO BAJO TECHO
2. LA RED DE VENTILAC. SERA INSTALADA CON TUBERIA PVC-CL Y

S
E
R
V
I
C
I
O
S
D
E
S
A
L
U
D
D
E
L
TERMINARAN A 0.30m SNTT. Y CON SOMBRERETE DE PROTECCION. TUBERÍA DE DESAGÜE, COLGADO BAJO LOSA
3. LAS TUB. DE VENT. QUE CORREN HORIZONTALMENTE POR MURO,
TUBERÍA DE VENTILACIÓN, EMPOTRADA O ENTERRADA
LO HARAN A UNA ALTURA DE 1.20m. S.N.P.T.

H
O
S
P
I
T
A
L
A
P
O
Y
O
C
A
S
M
A
I
I
-
1
TUBERÍA DE DESAGÜE, COLGADO BAJO TECHO
4. LAS TUB. PARA DESAGUE, TENDRAN UNA PENDIENTE MINIMA DE:
TUBERÍA DE DESAGÜE, COLGADO BAJO LOSA
DIAMETROS 4" A MAYORES, SERAN DEL 1.0% (Mín) DIAMETROS 3" A
INFERIORES, SERAN DEL 1.5% (Mín). TUBERÍA DE DESAGÜE COBRE, EMPOTRADA O ENTERRADA
TUBERÍA DE DESAGÜE COBRE, EMPOTRADA O ENTERRADA
5. LAS REDES DE DESAGUES QUE CORREN COLGANTES EN EL
TECHO, TODAS PASAN POR DEBAJO DE LAS VIGAS SALVO OTRA TUBERÍA DE DESAGÜE COBRE, EMPOTRADA O ENTERRADA
INDICACION. YEE SIMPLE

P
L
A
N
O
:
6. PARA LAS PRUEBAS DE LA RED DE DESAGUES, SE LLENARAN LAS CODO DE 45º
TUBERIAS Y TAPONEANDO LAS SALIDAS Y BAJADAS Y ESTOS CODO DE 90º
DEBERAN PERMANECER LLENAS DE AGUA, DURANTE 24 HORAS

PLANO REDES INTERIORES


POR LO MENOS ANTES DE CUBRIRLO CON EL MATERIAL CODO DE 90º SUBE
REQUERIDO.
CODO DE 90º BAJA
7. VERIFICAR NIVELES EN OBRA, ANTES DE INSTALAR LAS REDES DE TEE SANITARIA
DRENAJE.

8. LOS TUBOS DE VENTILACION DEBERAN TENER UNA PENDIENTE


TEE SANITARIA BAJA

TEE SANITARIA SUBE


DE DESAGÜE Y
UNIFORME NO MENOR DE 1% EN FORMA TAL QUE EL AGUA QUE
PUDIERE CONDENSARSE EN ELLOS, ESCURRA A UN CONDUCTO DE
DESAGUE O MONTANTE.
TRAMPA "P" VENTILACIÓN NIVEL 02 -
9. TODAS LAS MEDIDAS Y NIVELES ESTÁN EN METROS, SALVO
INDICACIÓN EXPRESA EN PLANOS. EL RESPONSABLE DE LA
SUMIDERO

REGISTRO ROSCADO BRONCE (RR)


SECTOR EP1-A
EJECUCIÓN DE OBRA DEBERÁ VERIFICAR DICHAS MEDIDAS Y
NIVELES. REGISTRO COLGADO BRONCE (RC)
ESPECIALIDAD :
10. NO PODRÁ EJECUTARSE NINGUNA MODIFICACIÓN SIN COLGADOR TIPO GOTA O SIMILAR PLANO LLAVE
SALUD PUBLICA /
AUTORIZACIÓN DEL RESPONSABLE DEL PROYECTO.
PASE EN MURO O VIGA

11. ANTES DE LA EJECUCION DE LOS TRABAJOS, EL CONTRATISTA


JUNTA FLEXIBLE ANTISISMICA

SISTEMAS SANITARIOS
DEBERÁ TENER EN CUENTA LAS ESPECIFICACIONES TÉCNICAS Y
PLANOS.
MD
N.F.T.... NIVEL DE FONDO
MONTANTE DE TUBERÍA
DE DESAGÜE (PVC-CP)
N.F.V.... NIVEL DE FONDO DE VIGA
12. DE EXISTIR DISCREPANCIAS, SE DEBERÁ CONSULTAR MDRT MONTANTE DE DESAGÜE (COBRE) RESISTENTE ALTAS TEMPERATURAS
NECESARIAMENTE CON EL PROYECTISTA.
BD BAJA DESAGÜE USO :
SALUD
13. PARA VER DETALLES DE DESAGUE REFERISE A LAM. DE VD VIENE DESAGÜE
DETALLES. MV MONTANTE DE VENTILACIÓN
VV
SV
VIENE VENTILACIÓN
SUBE VENTILACIÓN
EP1-A ZONA :

CASMA - ANCASH
CR-# CAJA DE REGISTRO DE DESAGÜE
C.F.T. COTA DE FONDO DE TUBO

ESCALA : FECHA : REV :


1/50 20/06/22 R01
CÓDIGO DEL PLANO :

100002-CSII001-141-02-DR-PL-000109