Water Cooled Chiller Service Report

Customer\ Name
Unit ID
Model
Serial
CHILLER REPORT
CHILLER OPERATING MODE
Active Chilled Water Temp. Setpoint, °F
Evap. Entering Water Temp., °F
Evap. Leaving Water Temp., °F
Cond. Entering Water Temp., °F
Cond. Leaving Water Temp., °F
Active Current Limit Setpoint
REFRIGERANT REPORT
Evap. Pressure, psi
Cond. Pressure, psi
Sat. Evap. Temp, °F
Sat. Cond. Temp, °F
Evap. Approach Temp, °F
Cond. Approach Temp, °F
COMPRESSOR REPORT
Differential Oil Pressure, psid
Oil Temp, °F
Discharge Oil Pressure, psid
Oil Tank Pressure
Oil Pump Heater Ampere
Oil Pump Motor Ampere
Operating Oil Level (Sight Glass), %
Compressor Phase Ampere A
Compressor Phase Ampere B
Compressor Phase Ampere C
Compressor Phase Voltage AB
Compressor Phase Voltage BC
Compressor Phase Voltage CA
Compressor Winding Temp A, °F
Compressor Winding Temp B, °F
Compressor Winding Temp C, °F
Compressor Start
Compressor Running Time
IGV Position Open
IGV Position Open
Compressor Power Factor, %
Compressor Power Input, kW
REMARK

Compressor Start
Compressor Running Time
IGV Position Open
IGV Position Open
Compressor Power Factor, %
Compressor Power Input, kW
REMARK

Ruko Sedayu Square Blok C No. 1 Cengkareng - Jakarta Barat T : 021 - 2255 7169
Ruko Sedayu Square Blok C No. 1 Cengkareng - Jakarta Barat T : 021 - 2255 7169
Air Cooled Chiller Service Report
Customer Name
GENERAL DATA
Unit ID
Model
Serial Number
Service Date
Refrigerant Type
Active Chilled Water Temp. Setpoint, °C
EVAPORATOR DATA
Evap. Entering Water Temp., °C
Evap. Leaving Water Temp., °C
Evap. Entering Water Pressure., Bar
Evap. Leaving Water Pressure., Bar
Evap.Refrigerant Temp, °C
Evap. Pressure, psi
CONDENSOR DATA
Cond. Refrigerant Pressure, psi
Cond. Refrigerant Temp, °C
Condensor Motor Fan 1 Current., A
Condensor Motor Fan 2 Current., A
Condensor Motor Fan 3 Current., A
Condensor Motor Fan 4 Current., A
Condensor Motor Fan 5 Current., A
Condensor Motor Fan 6 Current., A
Condensor Motor Fan 7 Current., A
Condensor Motor Fan 8 Current., A
Ambient Temp C
Condensor Fin condition
COMPRESSOR REPORT
Evap. Approach Temp, °C
Operating Oil Level (Sight Glass), %
Compressor Phase Ampere R
Compressor Phase Ampere S
Compressor Phase Ampere T
Compressor Phase Voltage RS
Compressor Phase Voltage ST
Compressor Phase Voltage TR
Compressor Running Time
IGV Position Open
Compressor Power Factor, %
Compressor Power Input, kW
EXPANSION VALVE
Normal/ Abnormal
Flow Switch Condition
REMARK