Tubing

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 66

1253170080200

1-1/4” 3.17 lb/ft N-80 w / 1-1/4” MT

TUBING SPECIFICATIONS
Grade N-80
Connection 1-1/4” MT
Upset Type Internal Welded
Nominal Weight per Foot 3.17 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1-3/4”
Inside Diameter 7/8”
Drift 13/16”
Minimum Make-up Torque 610 ft-lbs
Maximum Recommend Make-up Torque 670 ft-lbs
Torsional Yield 1020 ft-lbs

TUBE DATA
New Premium
Outside Diameter 1.660” 1.581”
Inside Diameter 1.264” 1.264”
Wall Thickness 0.198” 0.158”
Cross Sectional Area 0.909 sq in 0.708 sq in
Maximum Hook Load/Tensile Strength 72,700 lbs 56,600 lbs
Slip Crushing / Slip Type (TS-100) 63,900 lbs 50,000 lbs
Burst Pressure 16,700 psi 14,030 psi
Collapse Pressure 16,800 psi 14,430 psi
Torsional Yield Strength 2,300 ft-lbs 1,760 ft-lbs
Capacity 0.065 US gal/ft 0.065 US gal/ft
Displacement 0.047 US gal/ft 0.037 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/15/04
1253560080200

1-1/4” 3.56 lb/ft N-80 w / 1-1/4” MT

TUBING SPECIFICATIONS
Grade N-80
Connection 1-1/4” MT
Upset Type Internal Welded
Nominal Weight per Foot 3.56 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1-3/4”
Inside Diameter 13/16”
Drift 0.750”
Minimum Make-up Torque 690 ft-lbs
Maximum Recommend Make-up Torque 760 ft-lbs
Torsional Yield 1,150 ft-lbs

TUBE DATA
New Premium
Outside Diameter 1.660” 1.569”
Inside Diameter 1.204” 1.204”
Wall Thickness 0.228” 0.182”
Cross Sectional Area 1.026 sq in 0.794 sq in
Maximum Hook Load/Tensile Strength 82,000 lbs 63,600 lbs
Slip Crushing / Slip Type (TS-100) 72,000 lbs 56,200 lbs
Burst Pressure 19,230 psi 16,280 psi
Collapse Pressure 18,960 psi 16,440 psi
Torsional Yield Strength 2,500 ft-lbs 1,900 ft-lbs
Capacity 0.059 US gal/ft 0.059 US gal/ft
Displacement 0.053 US gal/ft 0.041 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/15/04
1253560110200

1-1/4” 3.56 lb/ft P-110 w / 1-1/4” MT DSI

TUBING SPECIFICATIONS
Grade P-110
Connection 1-1/4” MT DSI
Upset Type External Integral
Nominal Weight per Foot 3.56 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1-3/4”
Inside Diameter 13/16”
Drift 0.750”
Minimum Make-up Torque 690 ft-lbs
Maximum Recommend Make-up Torque 760 ft-lbs
Torsional Yield 1,570 ft-lbs

TUBE DATA
New Premium
Outside Diameter 1.660” 1.569”
Inside Diameter 1.204” 1.204”
Wall Thickness 0.228” 0.182”
Cross Sectional Area 1.026 sq in 0.794 sq in
Maximum Hook Load/Tensile Strength 112,800 lbs 87,400 lbs
Slip Crushing / Slip Type (TS-100) 99,100 lbs 77,300 lbs
Burst Pressure 26,440 psi 22,380 psi
Collapse Pressure 26,070 psi 22,600 psi
Torsional Yield Strength 3,440 ft-lbs 2,620 ft-lbs
Capacity 0.059 US gal/ft 0.059 US gal/ft
Displacement 0.053 US gal/ft 0.041 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/15/04
1254190080210

1-1/4” 4.19 lb/ft N-80 w / 1-1/4” MT LH

TUBING SPECIFICATIONS
Grade N-80
Connection 1-1/4” MT LH
Upset Type Internal Welded
Nominal Weight per Foot 4.19 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1-3/4”
Inside Diameter 0.750”
Drift 11/16”
Minimum Make-up Torque 690 ft-lbs
Maximum Recommend Make-up Torque 760 ft-lbs
Torsional Yield 1,150 ft-lbs

TUBE DATA
New Premium
Outside Diameter 1.660” 1.548”
Inside Diameter 1.100” 1.100”
Wall Thickness 0.280” 0.224”
Cross Sectional Area 1.214 sq in 0.932 sq in
Maximum Hook Load/Tensile Strength 97,100 lbs 74,500 lbs
Slip Crushing / Slip Type (TS-100) 85,300 lbs 66,000 lbs
Burst Pressure 23,600 psi 20,260 psi
Collapse Pressure 22,440 psi 19,800 psi
Torsional Yield Strength 2,790 ft-lbs 2,090 ft-lbs
Capacity 0.049 US gal/ft 0.049 US gal/ft
Displacement 0.063 US gal/ft 0.048 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/15/04
1504030080200

1-1/2” 4.03 lb/ft N-80 w / 1-1/2” MT

TUBING SPECIFICATIONS
Grade N-80
Connection 1-1/2” MT
Upset Type Internal Welded
Nominal Weight per Foot 4.03 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2”
Inside Diameter 1-1/16”
Drift 1”
Minimum Make-up Torque 835 ft-lbs
Maximum Recommend Make-up Torque 920 ft-lbs
Torsional Yield 1,390 ft-lbs

TUBE DATA
New Premium
Outside Diameter 1.900” 1.812”
Inside Diameter 1.462” 1.462”
Wall Thickness 0.219” 0.175”
Cross Sectional Area 1.157 sq in 0.901 sq in
Maximum Hook Load/Tensile Strength 92,500 lbs 72,100 lbs
Slip Crushing / Slip Type (TS-100) 79,600 lbs 62,500 lbs
Burst Pressure 16,140 psi 13,530 psi
Collapse Pressure 16,320 psi 13,970 psi
Torsional Yield Strength 3,365 ft-lbs 2,590 ft-lbs
Capacity 0.087 US gal/ft 0.087 US gal/ft
Displacement 0.060 US gal/ft 0.047 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/15/04
1504930080200

1-1/2” 4.93 lb/ft N-80 w / 1-1/2” MT

TUBING SPECIFICATIONS
Grade N-80
Connection 1-1/2” MT
Upset Type Internal Welded
Nominal Weight per Foot 4.93 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2”
Inside Diameter 1”
Drift 15/16”
Minimum Make-up Torque 935 ft-lbs
Maximum Recommend Make-up Torque 1,030 ft-lbs
Torsional Yield 1,560 ft-lbs

TUBE DATA
New Premium
Outside Diameter 1.900” 1.788”
Inside Diameter 1.340” 1.340”
Wall Thickness 0.280” 0.224”
Cross Sectional Area 1.425 sq in 1.101 sq in
Maximum Hook Load/Tensile Strength 114,000 lbs 88,000 lbs
Slip Crushing / Slip Type (TS-100) 98,100 lbs 76,500 lbs
Burst Pressure 20,630 psi 17,540 psi
Collapse Pressure 20,100 psi 17,530 psi
Torsional Yield Strength 3,900 ft-lbs 2,955 psi
Capacity 0.073 US gal/ft 0.073 US gal/ft
Displacement 0.074 US gal/ft 0.057 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/15/04
1504930110220

1-1/2” 4.93 lb/ft P-110 w / 1-1/2” MT DSI

TUBING SPECIFICATIONS
Grade P-110
Connection 1-1/2” MT DSI
Upset Type External Integral
Nominal Weight per Foot 4.93 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2”
Inside Diameter 1”
Drift 15/16”
Minimum Make-up Torque 935 ft-lbs
Maximum Recommend Make-up Torque 1,030 ft-lbs
Torsional Yield 2,380 ft-lbs

TUBE DATA
New Premium
Outside Diameter 1.900” 1.788”
Inside Diameter 1.340” 1.340”
Wall Thickness 0.280” 0.224”
Cross Sectional Area 1.425 sq in 1.101 sq in
Maximum Hook Load/Tensile Strength 156,700 lbs 121,100 lbs
Slip Crushing / Slip Type (TS-100) 134,900 lbs 105,200 lbs
Burst Pressure 28,370 psi 24,120 psi
Collapse Pressure 27,640 psi 24,110 psi
Torsional Yield Strength 5,360 ft-lbs 4,065 ft-lbs
Capacity 0.073 US gal/ft 0.073 US gal/ft
Displacement 0.074 US gal/ft 0.057 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/15/04
2384700080100

2-3/8” 4.70 lb/ft L-80 / N-80 w / 2-3/8” EUE 8rd

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-3/8” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 4.70 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.063”
Inside Diameter 1.995”
Drift 1.901”
Minimum Make-up Torque 1,500 ft-lbs
Maximum Recommend Make-up Torque 2,000 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.299”
Inside Diameter 1.995” 1.995”
Wall Thickness 0.190” 0.152”
Cross Sectional Area 1.304 sq in 1.025 sq in
Maximum Hook Load/Tensile Strength 104,300 lbs 82,000 lbs
Slip Crushing / Slip Type (SDML) 92,400 lbs 72,900 lbs
Burst Pressure 11,200 psi 9,260 psi
Collapse Pressure 11,780 psi 8,950 psi
Torsional Yield Strength 5,080 ft-lbs 3,970 ft-lbs
Capacity 0.162 US gal/ft 0.162 US gal/ft
Displacement 0.068 US gal/ft 0.053 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2384700110100

2-3/8” 4.70 lb/ft P-110 w / 2-3/8” EUE 8rd

TUBING SPECIFICATIONS
Grade P-110
Connection 2-3/8” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 4.70 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.063”
Inside Diameter 1.995”
Drift 1.901”
Minimum Make-up Torque 1,900 ft-lbs
Maximum Recommend Make-up Torque 2,300 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.299”
Inside Diameter 1.995” 1.995”
Wall Thickness 0.190” 0.152”
Cross Sectional Area 1.304 sq in 1.025 sq in
Maximum Hook Load/Tensile Strength 143,500 lbs 112,800 lbs
Slip Crushing / Slip Type (SDML) 127,100 lbs 100,300 lbs
Burst Pressure 15,400 psi 12,730 psi
Collapse Pressure 16,130 psi 11,270 psi
Torsional Yield Strength 6,990 ft-lbs 5,460 ft-lbs
Capacity 0.162 US gal/ft 0.162 US gal/ft
Displacement 0.068 US gal/ft 0.053 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2786500080100

2-7/8” 6.50 lb/ft L-80 / N-80 w / 2-7/8” EUE 8rd

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-7/8” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 6.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.668”
Inside Diameter 2.441”
Drift 2.347”
Minimum Make-up Torque 1,800 ft-lbs
Maximum Recommend Make-up Torque 2,300 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.788”
Inside Diameter 2.441” 2.441”
Wall Thickness 0.217” 0.174”
Cross Sectional Area 1.812 sq in 1.426 sq in
Maximum Hook Load/Tensile Strength 145,000 lbs 114,100 lbs
Slip Crushing / Slip Type (SDML) 125,000 lbs 98,800 lbs
Burst Pressure 10,570 psi 8,720 psi
Collapse Pressure 11,170 psi 8,000 psi
Torsional Yield Strength 8,620 ft-lbs 6,750 ft-lbs
Capacity 0.243 US gal/ft 0.273 US gal/ft
Displacement 0.094 US gal/ft 0.074 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2786500080110

2-7/8” 6.50 lb/ft L-80 / N-80 w / 2-7/8” EUE 8rd


Special Clearance Couplings

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-7/8” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 6.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.460”
Inside Diameter 2.441”
Drift 2.347”
Minimum Make-up Torque 1,800 ft-lbs
Maximum Recommend Make-up Torque 2,300 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.788”
Inside Diameter 2.441” 2.441”
Wall Thickness 0.217” 0.174”
Cross Sectional Area 1.812 sq in 1.426 sq in
Maximum Hook Load/Tensile Strength 145,000 lbs 114,100 lbs
Slip Crushing / Slip Type (SDML) 125,000 lbs 98,800 lbs
Burst Pressure 10,570 psi 8,720 psi
Collapse Pressure 11,170 psi 8,000 psi
Torsional Yield Strength 8,620 ft-lbs 6,750 ft-lbs
Capacity 0.243 US gal/ft 0.243 US gal/ft
Displacement 0.094 US gal/ft 0.074 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2786500110100

2-7/8” 6.50 lb/ft P-110 w / 2-7/8” EUE 8rd

TUBING SPECIFICATIONS
Grade P-110
Connection 2-7/8” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 6.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.668”
Inside Diameter 2.441”
Drift 2.347”
Minimum Make-up Torque 2,200 ft-lbs
Maximum Recommend Make-up Torque 2,900 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.788”
Inside Diameter 2.441” 2.441”
Wall Thickness 0.217” 0.174”
Cross Sectional Area 1.812 sq in 1.426 sq in
Maximum Hook Load/Tensile Strength 199,300 lbs 156,900 lbs
Slip Crushing / Slip Type (SDML) 171,800 lbs 135,900 lbs
Burst Pressure 14,530 psi 11,990 psi
Collapse Pressure 14,550 psi 9,920 psi
Torsional Yield Strength 11,850 ft-lbs 9,290 ft-lbs
Capacity 0.243 US gal/ft 0.243 US gal/ft
Displacement 0.094 US gal/ft 0.074 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2786500110110

2-7/8” 6.50 lb/ft P-110 w / 2-7/8” EUE 8rd


Special Clearance Coupling

TUBING SPECIFICATIONS
Grade P-110
Connection 2-7/8” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 6.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.460”
Inside Diameter 2.441”
Drift 2.347”
Minimum Make-up Torque 2,200 ft-lbs
Maximum Recommend Make-up Torque 2,900 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.788”
Inside Diameter 2.441” 2.441”
Wall Thickness 0.217” 0.174”
Cross Sectional Area 1.812 sq in 1.426 sq in
Maximum Hook Load/Tensile Strength 199,300 lbs 156,900 lbs
Slip Crushing / Slip Type (SDML) 171,800 lbs 135,900 lbs
Burst Pressure 14,530 psi 11,990 psi
Collapse Pressure 14,550 psi 9,920 psi
Torsional Yield Strength 11,850 ft-lbs 9,290 ft-lbs
Capacity 0.243 US gal/ft 0.243 US gal/ft
Displacement 0.094 US gal/ft 0.074 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
3509300800100

3-1/2” 9.30 lb/ft L-80 / N-80 w / 3-1/2” 8rd

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 3-1/2” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 9.30 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 4.500”
Inside Diameter 2.992”
Drift 2.867”
Minimum Make-up Torque 2,400 ft-lbs
Maximum Recommend Make-up Torque 3,200 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.298”
Inside Diameter 2.992” 2.992”
Wall Thickness 0.254” 0.203”
Cross Sectional Area 2.590 sq in 2.040 sq in
Maximum Hook Load/Tensile Strength 207,200 lbs 163,200 lbs
Slip Crushing / Slip Type (SDML) 172,700 lbs 136,700 lbs
Burst Pressure 10,160 psi 8,370 psi
Collapse Pressure 10,540 psi 7,400 psi
Torsional Yield Strength 15,100 ft-lbs 11,800 ft-lbs
Capacity 0.365 US gal/ft 0.365 US gal/ft
Displacement 0.135 US gal/ft 0.106 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
3509300080110

3-1/2” 9.30 lb/ft L-80 / N-80 w / 3-1/2” 8rd


Special Clearance Couplings

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 3-1/2” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 9.30 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 4.180”
Inside Diameter 2.992”
Drift 2.867”
Minimum Make-up Torque 2,400 ft-lbs
Maximum Recommend Make-up Torque 3,200 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.298”
Inside Diameter 2.992” 2.992”
Wall Thickness 0.254” 0.203”
Cross Sectional Area 2.590 sq in 2.040 sq in
Maximum Hook Load/Tensile Strength 207,200 lbs 163,200 lbs
Slip Crushing / Slip Type (SDML) 172,700 lbs 136,700 lbs
Burst Pressure 10,160 psi 8,370 psi
Collapse Pressure 10,540 psi 7,400 psi
Torsional Yield Strength 15,100 ft-lbs 11,800 ft-lbs
Capacity 0.365 US gal/ft 0.365 US gal/ft
Displacement 0.135 US gal/ft 0.106 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
3509300110100

3-1/2” 9.30 lb/ft P-110 w / 3-1/2” 8rd

TUBING SPECIFICATIONS
Grade P-110
Connection 3-1/2” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 9.30 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 4.500”
Inside Diameter 2.992”
Drift 2.867”
Minimum Make-up Torque 3,000 ft-lbs
Maximum Recommend Make-up Torque 4,000 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.298”
Inside Diameter 2.992” 2.992”
Wall Thickness 0.254” 0.203”
Cross Sectional Area 2.590 sq in 2.040 sq in
Maximum Hook Load/Tensile Strength 284,900 lbs 224,400 lbs
Slip Crushing / Slip Type (SDML) 237,400 lbs 188,000 lbs
Burst Pressure 13,970 psi 11,510 psi
Collapse Pressure 13,530 psi 9,060 psi
Torsional Yield Strength 20,700 ft-lbs 16,300 ft-lbs
Capacity 0.365 US gal/ft 0.365 US gal/ft
Displacement 0.135 US gal/ft 0.106 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
3509300110110

3-1/2” 9.30 lb/ft P-110 w / 3-1/2” 8rd


Special Clearance Couplings

TUBING SPECIFICATIONS
Grade P-110
Connection 3-1/2” EUE 8rd
Upset Type EUE
Nominal Weight per Foot 9.30 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 4.180”
Inside Diameter 2.992”
Drift 2.867”
Minimum Make-up Torque 3,000 ft-lbs
Maximum Recommend Make-up Torque 4,000 ft-lbs
Recommended power tong speed of 20 rpm or less for make up

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.298”
Inside Diameter 2.992” 2.992”
Wall Thickness 0.254” 0.203”
Cross Sectional Area 2.590 sq in 2.040 sq in
Maximum Hook Load/Tensile Strength 284,900 lbs 224,400 lbs
Slip Crushing / Slip Type (SDML) 237,400 lbs 188,000 lbs
Burst Pressure 13,970 psi 11,510 psi
Collapse Pressure 13,530 psi 9,060 psi
Torsional Yield Strength 20,700 ft-lbs 16,300 ft-lbs
Capacity 0.365 US gal/ft 0.365 US gal/ft
Displacement 0.135 US gal/ft 0.106 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
0751500110800

3/4" 1.50 lb/ft P-110 Tubing w / 3/4" WTS-8

TUBING SPECIFICATIONS
Grade P-110
Connection ¾” WTS-8
Interchangeable With Hydril ¾” CS
Upset Type External Integral
Nominal Weight per Foot 1.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.327”
Inside Diameter 0.687”
Drift 0.648”
Minimum Make-up Torque 300 ft-lbs
Maximum Recommend Make-up Torque 375 ft-lbs
Tensile Strength 55,650 lbs

TUBE DATA
New Premium
Outside Diameter 1.050” 0.988”
Inside Diameter 0.742” 0.742”
Wall Thickness 0.154” 0.123”
Cross Sectional Area 0.433 sq in 0.335 sq in
Maximum Hook Load/Tensile Strength 47,700 lbs 36,800 lbs
Slip Crushing / Slip Type (TS-100) 44,000 lbs 34,200 lbs
Burst Pressure 28,230 psi 23,970 psi
Collapse Pressure 27,540 psi 24,000 psi
Torsional Yield Strength 900 ft-lbs 685 ft-lbs
Capacity 0.022 US gal/ft 0.022 US gal/ft
Displacement 0.023 US gal/ft 0.017 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/15/04
1002250080800

1” 2.25 lb/ft L-80 / N-80 Tubing w / 1” WTS-8

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 1” WTS-8
Interchangeable With Hydril 1” CS
Upset Type External Integral
Nominal Weight per Foot 2.25 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.600”
Inside Diameter 0.864”
Drift 0.848”
Minimum Make-up Torque 400 ft-lbs
Maximum Recommend Make-up Torque 500 ft-lbs
Tensile Strength 55,700 lbs

TUBE DATA
New Premium
Outside Diameter 1.315” 1.243”
Inside Diameter 0.957” 0.957”
Wall Thickness 0.179” 0.143”
Cross Sectional Area 0.639 sq in 0.494 sq in
Maximum Hook Load/Tensile Strength 51,120 lbs 39,600 lbs
Slip Crushing / Slip Type (TS-100) 46,160 lbs 35,970 lbs
Burst Pressure 19,060 psi 16,120 psi
Collapse Pressure 18,820 psi 16,290 psi
Torsional Yield Strength 1,240 ft-lbs 940 ft-lbs
Capacity 0.037 US gal/ft 0.037 US gal/ft
Displacement 0.033 US gal/ft 0.026 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1002250095800

1” 2.25 lb/ft T-95 Tubing w / 1" WTS-8

TUBING SPECIFICATIONS
Grade T-95
Connection 1” WTS-8
Interchangeable With Hydril 1” CS
Upset Type External Integral
Nominal Weight per Foot 2.25 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.600”
Inside Diameter 0.864”
Drift 0.848”
Minimum Make-up Torque 400 ft-lbs
Maximum Recommend Make-up Torque 500 ft-lbs
Tensile Strength 66,100 lbs

TUBE DATA
New Premium
Outside Diameter 1.315” 1.234”
Inside Diameter 0.957” 0.957”
Wall Thickness 0.179” 0.143”
Cross Sectional Area 0.639 sq in 0.494 sq in
Maximum Hook Load/Tensile Strength 60,700 lbs 47,000 lbs
Slip Crushing / Slip Type (TS-100) 54,810 lbs 42,710 lbs
Burst Pressure 22,630 psi 19,150 psi
Collapse Pressure 22,340 psi 19,340 psi
Torsional Yield Strength 1,470 ft-lbs 1,120 ft-lbs
Capacity 0.037 US gal/ft 0.037 US gal/ft
Displacement 0.033 US gal/ft 0.026 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1002250110800

1” 2.25 lb/ft P-110 Tubing w / 1” WTS-8

TUBING SPECIFICATIONS
Grade P-110
Connection 1” WTS-8
Interchangeable With Hydril 1” CS
Upset Type External Integral
Nominal Weight per Foot 2.25 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.600”
Inside Diameter 0.864”
Drift 0.848”
Minimum Make-up Torque 400 ft-lbs
Maximum Recommend Make-up Torque 500 ft-lbs
Tensile Strength 76,500 lbs

TUBE DATA
New Premium
Outside Diameter 1.315” 1.243”
Inside Diameter 0.957” 0.957”
Wall Thickness 0.179” 0.143”
Cross Sectional Area 0.639 sq in 0.495 sq in
Maximum Hook Load/Tensile Strength 70,270 lbs 54,450 lbs
Slip Crushing / Slip Type (TS-100) 63,460 lbs 49,460 lbs
Burst Pressure 26,200 psi 22,170 psi
Collapse Pressure 25,870 psi 23,400 psi
Torsional Yield Strength 1,700 ft-lbs 1,300 ft-lbs
Capacity 0.037 US gal/ft 0.037 US gal/ft
Displacement 0.033 US gal/ft 0.026 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1002250135800

1” 2.25 lb/ft S-135 Tubing w / 1” WTS-8

TUBING SPECIFICATIONS
Grade S-135
Connection 1” WTS-8
Interchangeable With Hydril 1” CS
Upset Type External Integral
Nominal Weight per Foot 2.25 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.600”
Inside Diameter 0.864”
Drift 0.848”
Minimum Make-up Torque 500 ft-lbs
Maximum Recommend Make-up Torque 625 ft-lbs
Tensile Strength 93,900 lbs

TUBE DATA
New Premium
Outside Diameter 1.315” 1.243”
Inside Diameter 0.957” 0.957”
Wall Thickness 0.179” 0.143”
Cross Sectional Area 0.639 sq in 0.494 sq in
Maximum Hook Load/Tensile Strength 86,200 lbs 66,800 lbs
Slip Crushing / Slip Type (TS-100) 77,900 lbs 60,700 lbs
Burst Pressure 32,160 psi 27,200 psi
Collapse Pressure 31,750 psi 27,500 psi
Torsional Yield Strength 2,085 ft-lbs 1,590 ft-lbs
Capacity 0.037 US gal/ft 0.037 US gal/ft
Displacement 0.033 US gal/ft 0.026 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
1252400080800

1-1/4” 2.40 lb/ft L-80 / N-80 Tubing w / 1-1/4” WTS-8

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 1-1/4” WTS-8
Interchangeable With Hydril 1-1/4” CS
Upset Type External Integral
Nominal Weight per Foot 2.40 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.883”
Inside Diameter 1.380”
Drift 1.286”
Minimum Make-up Torque 600 ft-lbs
Maximum Recommend Make-up Torque 750 ft-lbs
Tensile Strength 57,480 lbs

TUBE DATA
New Premium
Outside Diameter 1.660” 1.604”
Inside Diameter 1.380” 1.380”
Wall Thickness 0.140” 0.112”
Cross Sectional Area 0.668 sq in 0.525 sq in
Maximum Hook Load/Tensile Strength 53,440 lbs 42,000 lbs
Slip Crushing / Slip Type (TS-100) 46,960 lbs 37,000 lbs
Burst Pressure 11,810 psi 9,780 psi
Collapse Pressure 12,360 psi 9,860 psi
Torsional Yield Strength 1,800 ft-lbs 1,410 ft-lbs
Capacity 0.078 US gal/ft 0.078 US gal/ft
Displacement 0.035 US gal/ft 0.027 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1253020080800

1-1/4” 3.02 lb/ft L-80 / N-80 Tubing w / 1-1/4” WTS-8

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 1-1/4” WTS-8
Interchangeable With Hydril 1-1/4” CS
Upset Type External Integral
Nominal Weight per Foot 3.02 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.927”
Inside Diameter 1.218”
Drift 1.184”
Minimum Make-up Torque 600 ft-lbs
Maximum Recommend Make-up Torque 750 ft-lbs
Tensile Strength 70,600 lbs

TUBE DATA
New Premium
Outside Diameter 1.660” 1.584”
Inside Diameter 1.278” 1.278”
Wall Thickness 0.191” 0.153”
Cross Sectional Area 0.881 sq in 0.687 sq in
Maximum Hook Load/Tensile Strength 70,520 lbs 54,950 lbs
Slip Crushing / Slip Type (TS-100) 61,910 lbs 48,550 lbs
Burst Pressure 16,110 psi 13,500 psi
Collapse Pressure 16,290 psi 13,950 psi
Torsional Yield Strength 2,240 ft-lbs 1,730 ft-lbs
Capacity 0.067 US gal/ft 0.067 US gal/ft
Displacement 0.046 US gal/ft 0.036 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1253020095800

1-1/4” 3.02 lb/ft T-95 Tubing w / 1-1/4” WTS-8

TUBING SPECIFICATIONS
Grade T-95
Connection 1-1/4” WTS-8
Interchangeable With Hydril 1-1/4” CS
Upset Type External Integral
Nominal Weight per Foot 3.02 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.927”
Inside Diameter 1.218”
Drift 1.848”
Minimum Make-up Torque 600 ft-lbs
Maximum Recommend Make-up Torque 750 ft-lbs
Tensile Strength 83,800 lbs

TUBE DATA
New Premium
Outside Diameter 1.660” 1.584”
Inside Diameter 1.278” 1.278”
Wall Thickness 0.191” 0.153”
Cross Sectional Area 0.881 sq in 0.687 sq in
Maximum Hook Load/Tensile Strength 83,740 lbs 65,250 lbs
Slip Crushing / Slip Type (TS-100) 73,520 lbs 57,650 lbs
Burst Pressure 19,130 psi 16,040 psi
Collapse Pressure 19,350 psi 16,560 psi
Torsional Yield Strength 2,660 ft-lbs 2,050 ft-lbs
Capacity 0.067 US gal/ft 0.067 US gal/ft
Displacement 0.046 US gal/ft 0.036 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1253020110800

1-1/4” 3.02 lb/ft P-110 Tubing w / 1-1/4” WTS-8

TUBING SPECIFICATIONS
Grade P-110
Connection 1-1/4” WTS-8
Interchangeable With Hydril 1-1/4” CS
Upset Type External Integral
Nominal Weight per Foot 3.02 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.927”
Inside Diameter 1.218”
Drift 1.184”
Minimum Make-up Torque 600 ft-lbs
Maximum Recommend Make-up Torque 750 ft-lbs
Tensile Strength 97,000 lbs

TUBE DATA
New Premium
Outside Diameter 1.660” 1.584”
Inside Diameter 1.278” 1.278”
Wall Thickness 0.191” 0.153”
Cross Sectional Area 0.881 sq in 0.687 sq in
Maximum Hook Load/Tensile Strength 96,960 lbs 75,550 lbs
Slip Crushing / Slip Type (TS-100) 85,130 lbs 66,750 lbs
Burst Pressure 22,150 psi 18,570 psi
Collapse Pressure 22,400 psi 19,180 psi
Torsional Yield Strength 3,080 ft-lbs 2,375 ft-lbs
Capacity 0.067 US gal/ft 0.067 US gal/ft
Displacement 0.046 US gal/ft 0.036 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1253020135800

1-1/4” 3.02 lb/ft S-135 Tubing w / 1-1/4” WTS-8

TUBING SPECIFICATIONS
Grade S-135
Connection 1-1/4” WTS-8
Interchangeable With Hydril 1-1/4” CS
Upset Type External Integral
Nominal Weight per Foot 3.02 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 1.927”
Inside Diameter 1.218”
Drift 1.184”
Minimum Make-up Torque 750 ft-lbs
Maximum Recommend Make-up Torque 950 ft-lbs
Tensile Strength 119,000 lbs

TUBE DATA
New Premium
Outside Diameter 1.660” 1.584”
Inside Diameter 1.278” 1.278”
Wall Thickness 0.191” 0.153”
Cross Sectional Area 0.881 sq in 0.687 sq in
Maximum Hook Load/Tensile Strength 119,000 lbs 92,720 lbs
Slip Crushing / Slip Type (TS-100) 104,480 lbs 81,920 lbs
Burst Pressure 27,180 psi 22,800 psi
Collapse Pressure 27,490 psi 23,540 psi
Torsional Yield Strength 3,780 ft-lbs 2,915 ft-lbs
Capacity 0.067 US gal/ft 0.067 US gal/ft
Displacement 0.046 US gal/ft 0.036 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
1503640080800

1-1/2” 3.64 lb/ft L-80 / N-80 Tubing w / 1-1/2” WTS-8

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 1-1/2” WTS-8
Interchangeable With Hydril 1-1/2” CS
Upset Type External Integral
Nominal Weight per Foot 3.64 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.162”
Inside Diameter 1.440”
Drift 1.406”
Minimum Make-up Torque 800 ft-lbs
Maximum Recommend Make-up Torque 1,000 ft-lbs
Tensile Strength 82,900 lbs

TUBE DATA
New Premium
Outside Diameter 1.900” 1.820”
Inside Diameter 1.500” 1.500”
Wall Thickness 0.200” 0.160”
Cross Sectional Area 1.068 sq in 0.834 sq in
Maximum Hook Load/Tensile Strength 85,500 lbs 66,700 lbs
Slip Crushing / Slip Type (TS-100) 73,500 lbs 57,800 lbs
Burst Pressure 14,740 psi 12,310 psi
Collapse Pressure 15,070 psi 12,830 psi
Torsional Yield Strength 3,170 ft-lbs 2,450 ft-lbs
Capacity 0.092 US gal/ft 0.092 US gal/ft
Displacement 0.056 US gal/ft 0.043 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1503640095800

1-1/2” 3.64 lb/ft T-95 w / 1-1/2” WTS-8

TUBING SPECIFICATIONS
Grade T-95
Connection 1-1/2” WTS-8
Interchangeable With Hydril 1-1/2” CS
Upset Type External Integral
Nominal Weight per Foot 3.64 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.162”
Inside Diameter 1.440”
Drift 1.406”
Minimum Make-up Torque 800 ft-lbs
Maximum Recommend Make-up Torque 1,000 ft-lbs
Tensile Strength 98,500 lbs

TUBE DATA
New Premium
Outside Diameter 1.900” 1.820”
Inside Diameter 1.500” 1.500”
Wall Thickness 0.200” 0.160”
Cross Sectional Area 1.068 sq in 0.834 sq in
Maximum Hook Load/Tensile Strength 101,500 lbs 79,300 lbs
Slip Crushing / Slip Type (TS-100) 87,300 lbs 68,700 lbs
Burst Pressure 17,500 psi 14,620 psi
Collapse Pressure 17,890 psi 15,230 psi
Torsional Yield Strength 3,760 ft-lbs 2,910 ft-lbs
Capacity 0.092 US gal/ft 0.092 US gal/ft
Displacement 0.056 US gal/ft 0.043 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1503640110800

1-1/2” 3.64 lb/ft P-110 Tubing w / 1-1/2” WTS-8

TUBING SPECIFICATIONS
Grade P-110
Connection 1-1/2” WTS-8
Interchangeable With Hydril 1-1/2” CS
Upset Type External Integral
Nominal Weight per Foot 3.64 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.162”
Inside Diameter 1.440”
Drift 1.406”
Minimum Make-up Torque 800 ft-lbs
Maximum Recommend Make-up Torque 1,000 ft-lbs
Tensile Strength 114,000 lbs

TUBE DATA
New Premium
Outside Diameter 1.900” 1.820”
Inside Diameter 1.500” 1.500”
Wall Thickness 0.200” 0.160”
Cross Sectional Area 1.068 sq in 0.834 sq in
Maximum Hook Load/Tensile Strength 117,500 lbs 91,800 lbs
Slip Crushing / Slip Type (TS-100) 101,100 lbs 79,500 lbs
Burst Pressure 20,260 psi 16,920 psi
Collapse Pressure 20,720 psi 17,640 psi
Torsional Yield Strength 4,350 ft-lbs 3,370 ft-lbs
Capacity 0.092 US gal/ft 0.092 US gal/ft
Displacement 0.056 US gal/ft 0.043 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
1503640135800

1-1/2” 3.64 lb/ft S-135 w / 1-1/2” WTS-8

TUBING SPECIFICATIONS
Grade S-135
Connection 1-1/2” WTS-8
Interchangeable With Hydril 1-1/2” CS
Upset Type External Integral
Nominal Weight per Foot 3.64 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.162”
Inside Diameter 1.440”
Drift 1.406”
Minimum Make-up Torque 1,000 ft-lbs
Maximum Recommend Make-up Torque 1,250 ft-lbs
Tensile Strength 140,000 lbs

TUBE DATA
New Premium
Outside Diameter 1.900” 1.820”
Inside Diameter 1.500” 1.500”
Wall Thickness 0.200” 0.160”
Cross Sectional Area 1.068 sq in 0.834 sq in
Maximum Hook Load/Tensile Strength 144,200 lbs 112,600 lbs
Slip Crushing / Slip Type (TS-100) 124,100 lbs 97,600 lbs
Burst Pressure 24,870 psi 20,770 psi
Collapse Pressure 25,430 psi 21,650 psi
Torsional Yield Strength 5,350 ft-lbs 4,140 ft-lbs
Capacity 0.092 US gal/ft 0.092 US gal/ft
Displacement 0.056 US gal/ft 0.043 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
2163250080800

2-1/16” 3.25 lb/ft L-80 / N-80 w / 2-1/16” WTS-8

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-1/16” WTS-8
Interchangeable With Hydril 2-1/16” CS
Upset Type External Integral
Nominal Weight per Foot 3.25 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.330”
Inside Diameter 1.700”
Drift 1.657”
Minimum Make-up Torque 900 ft-lbs
Maximum Recommend Make-up Torque 1,125 ft-lbs
Tensile Strength 78,500 lbs

TUBE DATA
New Premium
Outside Diameter 2.063” 2.000”
Inside Diameter 1.751” 1.751”
Wall Thickness 0.156” 0.125”
Cross Sectional Area 0.933 sq in 0.734”
Maximum Hook Load/Tensile Strength 74,600 lbs 58,700 lbs
Slip Crushing / Slip Type (TS-100) 63,400 lbs 50,100 lbs
Burst Pressure 10,570 psi 8,720 psi
Collapse Pressure 11,170 psi 8,010 psi
Torsional Yield Strength 3,185 ft-lbs 2,495 ft-lbs
Capacity 0.125 US gal/ft 0.125 US gal/ft
Displacement 0.048 US gal/ft 0.038 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2164500080800

2-1/16” 4.50 lb/ft L-80 / N-80 w / 2-1/16” WTS-8

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-1/16” WTS-8
Interchangeable With Hydril 2-1/16” CS
Upset Type External Integral
Nominal Weight per Foot 4.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.460”
Inside Diameter 1.550”
Drift 1.519”
Minimum Make-up Torque 900 ft-lbs
Maximum Recommend Make-up Torque 1,125 ft-lbs
Tensile Strength 109,300 lbs

TUBE DATA
New Premium
Outside Diameter 2.062” 1.973”
Inside Diameter 1.613” 1.613”
Wall Thickness 0.225” 0.180”
Cross Sectional Area 1.298 sq in 1.013 sq in
Maximum Hook Load/Tensile Strength 103,800 lbs 81,000 lbs
Slip Crushing / Slip Type (TS-100) 88,200 lbs 69,300 lbs
Burst Pressure 15,260 psi 12,760 psi
Collapse Pressure 15,540 psi 13,270 psi
Torsional Yield Strength 4,150 ft-lbs 3,200 ft-lbs
Capacity 0.106 US gal/ft 0.106 US gal/ft
Displacement 0.067 US gal/ft 0.052 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2164500110800

2-1/16” 4.50 lb/ft P-110 w / 2-1/16” WTS-8

TUBING SPECIFICATIONS
Grade P-110
Connection 2-1/16” WTS-8
Interchangeable With Hydril 2-1/16” CS
Upset Type External Integral
Nominal Weight per Foot 4.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.460”
Inside Diameter 1.550”
Drift 1.519”
Minimum Make-up Torque 1,000 ft-lbs
Maximum Recommend Make-up Torque 1,250 ft-lbs
Tensile Strength 150,300 ft-lbs

TUBE DATA
New Premium
Outside Diameter 2.062” 1.973”
Inside Diameter 1.613” 1.613”
Wall Thickness 0.225” 0.180”
Cross Sectional Area 1.298 sq in 1.013 sq in
Maximum Hook Load/Tensile Strength 142,700 lbs 111,400 lbs
Slip Crushing / Slip Type (TS-100) 121,200 lbs 95,300 lbs
Burst Pressure 20,980 psi 17,550 psi
Collapse Pressure 21,360 psi 18,230 psi
Torsional Yield Strength 5,700 ft-lbs 4,400 ft-lbs
Capacity 0.106 US gal/ft 0.106 US gal/ft
Displacement 0.067 US gal/ft 0.052 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2164500135800

2-1/16” 4.50 lb/ft S-135 w / 2-1/16” WTS-8

TUBING SPECIFICATIONS
Grade S-135
Connection 2-1/16” WTS-8
Interchangeable With Hydril 2-1/16” CS
Upset Type External Integral
Nominal Weight per Foot 4.50 ft-lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.460”
Inside Diameter 1.550”
Drift 1.519”
Minimum Make-up Torque 1,100 ft-lbs
Maximum Recommend Make-up Torque 1,375 ft-lbs
Tensile Strength 184,500 lbs

TUBE DATA
New Premium
Outside Diameter 2.062” 1.973”
Inside Diameter 1.613” 1.613”
Wall Thickness 0.225” 0.180”
Cross Sectional Area 1.298 sq in 1.013 sq in
Maximum Hook Load/Tensile Strength 175,200 lbs 136,700 lbs
Slip Crushing / Slip Type (TS-100) 148,800 lbs 117,000 lbs
Burst Pressure 25,700 psi 21,530 psi
Collapse Pressure 26,220 psi 22,370 psi
Torsional Yield Strength 7,000 ft-lbs 5,400 ft-lbs
Capacity 0.106 US gal/ft 0.106 US gal/ft
Displacement 0.067 US gal/ft 0.052 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
2384700080800

2-3/8” 4.70 lb/ft N-80/L-80 w/ 2-3/8” WTS-8

TUBING SPECIFICATIONS
Grade N-80/L-80
Connection 2-3/8” WTS-8
Interchangeable With Hydril 2-3/8” CS
Upset Type External Integral
Nominal Weight per Foot 4.70 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.700”
Inside Diameter 1.945”
Drift 1.901”
Minimum Make-up Torque 1,500 ft-lbs
Maximum Recommend Make-up Torque 1,875 ft-lbs
Tensile Strength 107,440 lbs

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.299”
Inside Diameter 1.995” 1.995”
Wall Thickness 0.190” 0.152”
Cross Sectional Area 1.304 sq in 1.165 sq in
Maximum Hook Load/Tensile Strength 104,320 lbs 93,200 lbs
Slip Crushing / Slip Type (SDML) 92,405 lbs 72,935 lbs
Burst Pressure 11,200 psi 8,950 psi
Collapse Pressure 11,770 psi 12,360 psi
Torsional Yield Strength 5080 ft-lbs 3,975 ft-lbs
Capacity W/ Tool Joint 0.162 US gal/ft 0.162 US gal/ft
Displacement W/ Tool Joint 0.068 US gal/ft 0.053 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

7/29/04
2384700110800

2-3/8” 4.70 lb/ft P110 w / 2-3/8” WTS-8

TUBING SPECIFICATIONS
Grade P110
Connection 2-3/8” WTS-8
Interchangeable With Hydril 2-3/8” CS
Upset Type External Integral
Nominal Weight per Foot 4.70 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.700”
Inside Diameter 1.945”
Drift 1.901”
Minimum Make-up Torque 1,500 ft-lbs
Maximum Recommend Make-up Torque 1,875 ft-lbs
Tensile Strength 147,730 lbs

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.299”
Inside Diameter 1.995” 1.995”
Wall Thickness 0.190” 0.152”
Cross Sectional Area 1.304 sq in 1.165 sq in
Maximum Hook Load/Tensile Strength 143,440 lbs 128,150 lbs
Slip Crushing / Slip Type (SDML) 127,000 lbs 100,280 lbs
Burst Pressure 15,400 psi 12,730 psi
Collapse Pressure 16,130 psi 11,275 psi
Torsional Yield Strength 6,985 ft-lbs 5,465 ft-lbs
Capacity W/ Tool Joint 0.162 US gal/ft 0.162 US gal/ft
Displacement W/ Tool Joint 0.068 US gal/ft 0.053 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

7/29/04
2786500080800

2-7/8” 6.50 lb/ft L-80 / N-80 w/ 2-7/8” WTS-8

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-7/8” WTS-8
Interchangeable With Hydril 2-7/8” CS
Upset Type External Integral
Nominal Weight per Foot 6.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.220”
Inside Diameter 2.371”
Drift 2.347”
Minimum Make-up Torque 2,100 ft-lbs
Maximum Recommend Make-up Torque 2,625 ft-lbs
Tensile Strength 143,400 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.788”
Inside Diameter 2.441” 2.441”
Wall Thickness 0.217” 0.174”
Cross Sectional Area 1.812 sq in 1.426 sq in
Maximum Hook Load/Tensile Strength 144,960 lbs 114,075 lbs
Slip Crushing / Slip Type (SDML) 124,960 lbs 98,800 lbs
Burst Pressure 10,560 psi 8,720 psi
Collapse Pressure 11,160 psi 8,040 psi
Torsional Yield Strength 8,620 ft-lbs 6,750 ft-lbs
Capacity 0.243 US gal/ft 0.243 US gal/ft
Displacement 0.094 US gal/ft 0.074 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2786500110800

2-7/8” 6.50 lb/ft P-110 w/ 2-7/8” WTS-8

TUBING SPECIFICATIONS
Grade P-110
Connection 2-7/8” WTS-8
Interchangeable With Hydril 2-7/8” CS
Upset Type External Integral
Nominal Weight per Foot 6.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.220”
Inside Diameter 2.375”
Drift 2.347”
Minimum Make-up Torque 2,100 ft-lbs
Maximum Recommend Make-up Torque 2,600 ft-lbs
Tensile Strength 197,200 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.787”
Inside Diameter 2.441” 2.441”
Wall Thickness 0.217” 0.174”
Cross Sectional Area 1.812 sq in 1.429 sq in
Maximum Hook Load/Tensile Strength 199,300 lbs 157,200 lbs
Slip Crushing / Slip Type (SDML) 171,800 lbs 135,800 lbs
Burst Pressure 14,500 psi 12,000 psi
Collapse Pressure 14,550 psi 9,985 psi
Torsional Yield Strength 11,850 ft-lbs 9,250 ft-lbs
Capacity 0.243 US gal/ft 0.243 US gal/ft
Displacement 0.0941 US gal/ft 0.0743 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
3509300110800

3-1/2” 9.30 lb/ft P-110 w / 3-1/2” WTS-8

TUBING SPECIFICATIONS
Grade P-110
Connection 3-1/2” WTS-8
Interchangeable With Hydril 3-1/2” CS
Upset Type External Integral
Nominal Weight per Foot 9.30 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.905”
Inside Diameter 2.920”
Drift 2.867”
Minimum Make-up Torque 3,000 ft-lbs
Maximum Recommend Make-up Torque 3,800 ft-lbs
Tensile Strength 293,810 lbs

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.398”
Inside Diameter 2.992” 2.992”
Wall Thickness 0.254” 0.203”
Cross Sectional Area 2.590 sq in 2.038 sq in
Maximum Hook Load/Tensile Strength 284,900 lbs 224,200 lbs
Slip Crushing / Slip Type (SDML) 237,400 lbs 187,987 lbs
Burst Pressure 13,970 psi 11,500 psi
Collapse Pressure 13,530 psi 9,040 psi
Torsional Yield Strength 20,747 ft-lbs 16,253 ft-lbs
Capacity 0.365 US gal/ft 0.365 US gal/ft
Displacement 0.134 US gal/ft 0.106 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
2385950080600

2-3/8” 5.95 lb/ft L-80 / N-80 w/ 2-3/8” WTS-6

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-3/8” WTS-6
Interchangeable With Hydril 2-3/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 5.95 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.906”
Inside Diameter 1.805”
Drift 1.773”
Minimum Make-up Torque 2,200 ft-lbs
Maximum Recommend Make-up Torque 2,750 ft-lbs
Tensile Strength 144,100 lbs

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.273”
Inside Diameter 1.867” 1.867”
Wall Thickness 0.254” 0.203”
Cross Sectional Area 1.692 sq in 1.320 sq in
Maximum Hook Load/Tensile Strength 135,400 lbs 105,700 lbs
Slip Crushing / Slip Type (SDML) 119,900 lbs 94,100 lbs
Burst Pressure 14,970 psi 12,510 psi
Collapse Pressure 15,280 psi 13,000 psi
Torsional Yield Strength 6,250 ft-lbs 4,835 ft-lbs
Capacity 0.142 US gal/ft 0.142 US gal/ft
Displacement 0.088 US gal/ft 0.069 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2385950095600

2-3/8” 5.95 lb/ft T-95 w / 2-3/8” WTS-6

TUBING SPECIFICATIONS
Grade T-95
Connection 2-3/8” WTS-6
Interchangeable With Hydril 2-3/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 5.95 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.906”
Inside Diameter 1.805”
Drift 1.773”
Minimum Make-up Torque 2,500 ft-lbs
Maximum Recommend Make-up Torque 3,125 ft-lbs
Tensile Strength 171,200 lbs

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.273”
Inside Diameter 1.867” 1.867”
Wall Thickness 0.254” 0.203”
Cross Sectional Area 1.692 sq in 1.320 sq in
Maximum Hook Load/Tensile Strength 160,800 lbs 125,500 lbs
Slip Crushing / Slip Type (SDML) 142,400 lbs 111,800 lbs
Burst Pressure 17,780 psi 14,860 psi
Collapse Pressure 18,150 psi 15,450 psi
Torsional Yield Strength 7,430 ft-lbs 5,745 ft-lbs
Capacity 0.142 US gal/ft 0.142 US gal/ft
Displacement 0.088 US gal/ft 0.069 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2385950110600

2-3/8” 5.95 lb/ft P-110 w / 2-3/8” WTS-6

TUBING SPECIFICATIONS
Grade P-110
Connection 2-3/8” WTS-6
Interchangeable With Hydril 2-3/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 5.95 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.906”
Inside Diameter 1.805”
Drift 1.773”
Minimum Make-up Torque 2,700 ft-lbs
Maximum Recommend Make-up Torque 3,375 ft-lbs
Tensile Strength 198,200 lbs

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.273”
Inside Diameter 1.867” 1.867”
Wall Thickness 0.254” 0.203”
Cross Sectional Area 1.692 sq in 1.322 sq in
Maximum Hook Load/Tensile Strength 186,200 lbs 145,400 lbs
Slip Crushing / Slip Type (SDML) 164,900 lbs 129,500 lbs
Burst Pressure 20,590 psi 17,200 psi
Collapse Pressure 21,010 psi 17,900 psi
Torsional Yield Strength 8,600 ft-lbs 6,650 ft-lbs
Capacity 0.142 US gal/ft 0.142 US gal/ft
Displacement 0.088 US gal/ft 0.069 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2385950135600

2-3/8” 5.95 lb/ft S-135 w / 2-3/8” WTS-6

TUBING SPECIFICATIONS
Grade S-135
Connection 2-3/8” WTS-6
Interchangeable With Hydril 2-3/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 5.95 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 2.906”
Inside Diameter 1.805”
Drift 1.773”
Minimum Make-up Torque 3,000 ft-lbs
Maximum Recommend Make-up Torque 3,750 ft-lbs
Tensile Strength 243,300 lbs

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.273”
Inside Diameter 1.867” 1.867”
Wall Thickness 0.254” 0.203”
Cross Sectional Area 1.692 sq in 1.322 sq in
Maximum Hook Load/Tensile Strength 228,500 lbs 178,400 lbs
Slip Crushing / Slip Type (SDML) 202,400 lbs 158,900 lbs
Burst Pressure 25,270 psi 21,120 psi
Collapse Pressure 25,790 psi 21,980 psi
Torsional Yield Strength 10,550 ft-lbs 8,165 ft-lbs
Capacity 0.142 US gal/ft 0.142 US gal/ft
Displacement 0.088 US gal/ft 0.069 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
2387700080600

2-3/8” 7.70 lb/ft L-80 / N-80 w / 2-3/8” WTS-6

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-3/8” WTS-6
Interchangeable With Hydril 2-3/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 7.70 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.125”
Inside Diameter 1.645”
Drift 1.609”
Minimum Make-up Torque 2,200 ft-lbs
Maximum Recommend Make-up Torque 2,750 ft-lbs
Tensile Strength 179,000 lbs

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.241”
Inside Diameter 1.703” 1.703”
Wall Thickness 0.336” 0.269”
Cross Sectional Area 2.152 sq in 1.665 sq in
Maximum Hook Load/Tensile Strength 172,200 lbs 133,200 lbs
Slip Crushing / Slip Type (SDML) 152,500 lbs 118,830 lbs
Burst Pressure 19,800 psi 16,800 psi
Collapse Pressure 19,430 psi 16,900 psi
Torsional Yield Strength 7,440 ft-lbs 5,660 ft-lbs
Capacity 0.118 US gal/ft 0.118 US gal/ft
Displacement 0.112 US gal/ft 0.086 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2387700095600

2-3/8” 7.70 lb/ft T-95 w / 2-3/8” WTS-6

TUBING SPECIFICATIONS
Grade T-95
Connection 2-3/8” WTS-6
Interchangeable With Hydril 2-3/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 7.70 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.125”
Inside Diameter 1.645”
Drift 1.609”
Minimum Make-up Torque 2,500 ft-lbs
Maximum Recommend Make-up Torque 3,125 ft-lbs
Tensile Strength 212,600 lbs

TUBE DATA
New Premium
Outside Diameter 2-3/8” 2.241”
Inside Diameter 1.703” 1.703”
Wall Thickness 0.336” 0.269”
Cross Sectional Area 2.152 sq in 1.665 sq in
Maximum Hook Load/Tensile Strength 204,500 lbs 158,200 lbs
Slip Crushing / Slip Type (SDML) 181,100 lbs 141,100 lbs
Burst Pressure 23,520 psi 19,950 psi
Collapse Pressure 23,080 psi 20,060 psi
Torsional Yield Strength 8,840 ft-lbs 6,720 ft-lbs
Capacity 0.118 US gal/ft 0.118 US gal/ft
Displacement 0.112 US gal/ft 0.086 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2787900080600

2-7/8” 7.90 lb/ft L-80 / N-80 w / 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-7/8” WTS-6
Interchangeable With Hydril 2-7/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 7.90 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.438”
Inside Diameter 2.265”
Drift 2.229”
Minimum Make-up Torque 3,000 ft-lbs
Maximum Recommend Make-up Torque 3,750 ft-lbs
Tensile Strength 190,200 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.795”
Inside Diameter 2.323” 2.323”
Wall Thickness 0.276” 0.221”
Cross Sectional Area 2.254 sq in 1.765 sq in
Maximum Hook Load/Tensile Strength 180,300 lbs 141,200 lbs
Slip Crushing / Slip Type (SDML) 155,400 lbs 122,400 lbs
Burst Pressure 13,440 psi 11,180 psi
Collapse Pressure 13,890 psi 11,760 psi
Torsional Yield Strength 10,300 ft-lbs 8,000 ft-lbs
Capacity 0.220 US gal/ft 0.220 US gal/ft
Displacement 0.117 US gal/ft 0.092 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2787900095600

2-7/8” 7.90 lb/ft T-95 w / 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade T-95
Connection 2-7/8” WTS-6
Interchangeable With Hydril 2-7/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 7.90 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.438”
Inside Diameter 2.265”
Drift 2.229”
Minimum Make-up Torque 3,400 ft-lbs
Maximum Recommend Make-up Torque 4,250 ft-lbs
Tensile Strength 225,800 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.765”
Inside Diameter 2.323” 2.323”
Wall Thickness 0.276” 0.221”
Cross Sectional Area 2.254 sq in 1.765 sq in
Maximum Hook Load/Tensile Strength 214,100 lbs 167,600 lbs
Slip Crushing / Slip Type (SDML) 184,600 lbs 145,400 lbs
Burst Pressure 15,960 psi 13,280 psi
Collapse Pressure 16,490 psi 13,970 psi
Torsional Yield Strength 12,300 ft-lbs 9,500 ft-lbs
Capacity 0.220 US gal/ft 0.220 US gal/ft
Displacement 0.117 US gal/ft 0.092 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2787900110600

2-7/8” 7.90 lb/ft P-110 w/ 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade P-110
Connection 2-7/8” WTS-6
Interchangeable With Hydril 2-7/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 7.90 lbs

CONNECTION DATA
Outside Diameter 3.438”
Inside Diameter 2.265”
Drift 2.229”
Minimum Make-up Torque 3,500 ft-lbs
Maximum Recommend Make-up Torque 4,375 ft-lbs
Tensile Strength 261,500 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.765”
Inside Diameter 2.323” 2.323”
Wall Thickness 0.276” 0.221”
Cross Sectional Area 2.254 sq in 1.765 sq in
Maximum Hook Load/Tensile Strength 248,000 lbs 194,100 lbs
Slip Crushing / Slip Type (SDXL) 213,700 lbs 168,300 lbs
Burst Pressure 18,480 psi 15,370 psi
Collapse Pressure 19,090 psi 16,080 psi
Torsional Yield Strength 14,160 ft-lbs 11,000 ft-lbs
Capacity 0.220 US gal/ft 0.220 US gal/ft
Displacement 0.117 US gal/ft 0.092 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss, damage or injury
resulting from the use of the information listed above. All applications are for guidelines and
the data described are at the user’s own risk and are the user’s responsibility.

9/14/04
2787900125600

2-7/8” 7.90 lb/ft Q-125 w / 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade Q-125
Connection WTS-6
Interchangeable With Hydril PH-6
Upset Type External Integral
Nominal Weight per Foot 7.90 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.438”
Inside Diameter 2.265”
Drift 2.229”
Minimum Make-up Torque 3,500 ft-lbs
Maximum Recommend Make-up Torque 4,370 ft-lbs
Tensile Strength 297,200 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.765”
Inside Diameter 2.323” 2.323”
Wall Thickness 0.276” 0.221”
Cross Sectional Area 2.254 sq in 1.765 sq in
Maximum Hook Load/Tensile Strength 281,700 lbs 220,600 lbs
Slip Crushing / Slip Type (SDML) 242,800 lbs 191,300 lbs
Burst Pressure 21,000 psi 17,470 psi
Collapse Pressure 21,700 psi 17,850 psi
Torsional Yield Strength 16,100 ft-lbs 12,500 ft-lbs
Capacity 0.220 US gal/ft 0.220 US gal/ft
Displacement 0.117 US gal/ft 0.092 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

2/7/05
2787900135600

2-7/8” 7.90 lb/ft S-135 w/ 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade S-135
Connection 2-7/8” WTS-6
Interchangeable With Hydril 2-7/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 7.90 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.438”
Inside Diameter 2.265”
Drift 2.229”
Minimum Make-up Torque 3,800 ft-lbs
Maximum Recommend Make-up Torque 4,750 ft-lbs
Tensile Strength 320,900 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.765”
Inside Diameter 2.323” 2.323”
Wall Thickness 0.276” 0.221”
Cross Sectional Area 2.254 sq in 1.765 sq in
Maximum Hook Load/Tensile Strength 304,200 lbs 238,200 lbs
Slip Crushing / Slip Type (SDML) 262,300 lbs 206,600 lbs
Burst Pressure 22,680 psi 18,870 psi
Collapse Pressure 23,430 psi 18,980 psi
Torsional Yield Strength 17,375 ft-lbs 13,500 ft-lbs
Capacity 0.220 US gal/ft 0.220 US gal/ft
Displacement 0.117 US gal/ft 0.092 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
2788700080600

2-7/8” 8.70 lb/ft L-80 / N-80 w / 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 2-7/8” WTS-6
Interchangeable With Hydril 2-7/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 8.70 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.500”
Inside Diameter 2.200”
Drift 2.165”
Minimum Make-up Torque 3,000 ft-lbs
Maximum Recommend Make-up Torque 3,750 ft-lbs
Tensile Strength 208,500 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.752”
Inside Diameter 2.259” 2.259”
Wall Thickness 0.308” 0.246”
Cross Sectional Area 2.484 sq in 1.939 sq in
Maximum Hook Load/Tensile Strength 198,700 lbs 155,200 lbs
Slip Crushing / Slip Type (SDML) 171,300 lbs 134,600 lbs
Burst Pressure 15,000 psi 12,540 psi
Collapse Pressure 15,300 psi 13,040 psi
Torsional Yield Strength 11,100 ft-lbs 8,590 ft-lbs
Capacity 0.208 US gal/ft 0.208 US gal/ft
Displacement 0.129 US gal/ft 0.101 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2788700095600

2-7/8” 8.70 lb/ft T-95 w / 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade T-95
Connection 2-7/8” WTS-6
Interchangeable With Hydril 2-7/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 8.70 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.500”
Inside Diameter 2.200”
Drift 2.165”
Minimum Make-up Torque 3,400 ft-lbs
Maximum Recommend Make-up Torque 4,250 ft-lbs
Tensile Strength 247,600 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.752”
Inside Diameter 2.259” 2.259”
Wall Thickness 0.308” 0.246”
Cross Sectional Area 2.484 sq in 1.939 sq in
Maximum Hook Load/Tensile Strength 236,000 lbs 184,200 lbs
Slip Crushing / Slip Type (SDML) 203,400 lbs 159,900 lbs
Burst Pressure 17,810 psi 14,890 psi
Collapse Pressure 18,170 psi 15,490 psi
Torsional Yield Strength 13,190 ft-lbs 10,200 psi
Capacity 0.208 US gal/ft 0.208 US gal/ft
Displacement 0.129 US gal/ft 0.101 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2788700110600

2-7/8” 8.70 lb/ft P-110 w / 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade P-110
Connection 2-7/8” WTS-6
Interchangeable With Hydril 2-7/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 8.70 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.500”
Inside Diameter 2.200”
Drift 2.165”
Minimum Make-up Torque 3,500 ft-lbs
Maximum Recommend Make-up Torque 4,375 ft-lbs
Tensile Strength 286,700 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.752”
Inside Diameter 2.259” 2.259”
Wall Thickness 0.308” 0.246”
Cross Sectional Area 2.484 sq in 1.939 sq in
Maximum Hook Load/Tensile Strength 273,200 lbs 213,300 lbs
Slip Crushing / Slip Type (SDML) 235,500 lbs 185,100 lbs
Burst Pressure 20,620 psi 17,240 psi
Collapse Pressure 21,040 psi 17,930 psi
Torsional Yield Strength 15,270 ft-lbs 11,810 ft-lbs
Capacity 0.208 US gal/ft 0.208 US gal/ft
Displacement 0.129 US gal/ft 0.101 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
2788700135600

2-7/8” 8.70 lb/ft S-135 Tubing w / 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade S-135
Connection 2-7/8” WTS-6
Interchangeable With Hydril 2-7/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 8.7 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.500”
Inside Diameter 2.200”
Drift 2.165”
Minimum Make-up Torque 3,800 ft-lbs
Maximum Recommend Make-up Torque 4,750 ft-lbs
Tensile Strength 351,800 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.752”
Inside Diameter 2.259” 2.259”
Wall Thickness 0.308” 0.246”
Cross Sectional Area 2.484” 1.939”
Maximum Hook Load/Tensile Strength 335,300 lbs 261,800 lbs
Slip Crushing / Slip Type (SDML) 289,100 lbs 227,200 lbs
Burst Pressure 25,310 psi 21,160 psi
Collapse Pressure 25,830 psi 22,000 psi
Torsional Yield Strength 18,740 ft-lbs 14,500 ft-lbs
Capacity 0.208 US gal/ft 0.208 US gal/ft
Displacement 0.129 US gal/ft 0.101 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
2789500095600

2-7/8” 9.50 lb/ft T-95 w / 2-7/8” WTS-6

TUBING SPECIFICATIONS
Grade T-95
Connection 2-7/8” WTS-6
Interchangeable With Hydril 2-7/8” PH-6
Upset Type External Integral
Nominal Weight per Foot 9.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 3.625”
Inside Diameter 2.130”
Drift 2.101”
Minimum Make-up Torque 5,000 ft-lbs
Maximum Recommend Make-up Torque 6,250 ft-lbs
Tensile Strength 270,300 lbs

TUBE DATA
New Premium
Outside Diameter 2-7/8” 2.739”
Inside Diameter 2.195” 2.195”
Wall Thickness 0.340” 0.272”
Cross Sectional Area 2.708 sq in 2.108 sq in
Maximum Hook Load/Tensile Strength 257,200 lbs 200,300 lbs
Slip Crushing / Slip Type (SDML) 221,700 lbs 173,900 lbs
Burst Pressure 19,660 psi 16,510 psi
Collapse Pressure 19,810 psi 16,990 psi
Torsional Yield Strength 14,070 ft-lbs 10,830 ft-lbs
Capacity 0.197 US gal/ft 0.197 US gal/ft
Displacement 0.141 US gal/ft 0.110 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
3501295080600

3-1/2” 12.95 lb/ft L-80 / N-80 w/ 3-1/2” WTS-6

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 3-1/2” WTS-6
Interchangeable With Hydril 3-1/2” PH-6
Upset Type External Integral
Nominal Weight per Foot 12.95 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 4.313”
Inside Diameter 2.687”
Drift 2.625”
Minimum Make-up Torque 5,500 ft-lbs
Maximum Recommend Make-up Torque 6,875 ft-lbs
Tensile Strength 345,100 lbs

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.350”
Inside Diameter 2.750” 2.750”
Wall Thickness 0.375” 0.300”
Cross Sectional Area 3.682 sq in 2.875 sq in
Maximum Hook Load/Tensile Strength 294,500 lbs 230,000 lbs
Slip Crushing / Slip Type (SDML) 245,400 lbs 193,200 lbs
Burst Pressure 15,000 psi 12,540 psi
Collapse Pressure 15,310 psi 13,040 psi
Torsional Yield Strength 20,040 ft-lbs 15,500 ft-lbs
Capacity 0.309 US gal/ft 0.309 US gal/ft
Displacement 0.191 US gal/ft 0.149 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
3501295095600

3-1/2” 12.95 lb/ft T-95 w / 3-1/2” WTS-6

TUBING SPECIFICATIONS
Grade T-95
Connection 3-1/2” WTS-6
Interchangeable With Hydril 3-1/2” PH-6
Upset Type External Integral
Nominal Weight per Foot 12.95 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 4.313”
Inside Diameter 2.687”
Drift 2.625”
Minimum Make-up Torque 6,000 ft-lbs
Maximum Recommend Make-up Torque 7,500 ft-lbs
Tensile Strength 409,800 lbs

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.350”
Inside Diameter 2.750” 2.750”
Wall Thickness 0.375” 0.300”
Cross Sectional Area 3.682 sq in 2.875 sq in
Maximum Hook Load/Tensile Strength 349,700 lbs 273,100 lbs
Slip Crushing / Slip Type (SDML) 291,400 lbs 229,400 lbs
Burst Pressure 17,810 psi 14,900 psi
Collapse Pressure 18,180 psi 15,490 psi
Torsional Yield Strength 23,800 ft-lbs 18,410 ft-lbs
Capacity 0.309 US gal/ft 0.309 US gal/ft
Displacement 0.191 US gal/ft 0.149 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
3501295110600

3-1/2” 12.95 lb/ft P-110 w / 3-1/2” WTS-6

TUBING SPECIFICATIONS
Grade P-110
Connection 3-1/2” WTS-6
Interchangeable With Hydril 3-1/2” PH-6
Upset Type External Integral
Nominal Weight per Foot 12.95 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 4.313”
Inside Diameter 2.687”
Drift 2.625”
Minimum Make-up Torque 7,000 ft-lbs
Maximum Recommend Make-up Torque 8,750 ft-lbs
Tensile Strength 474,500 lbs

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.350”
Inside Diameter 2.750” 2.750”
Wall Thickness 0.375” 0.300”
Cross Sectional Area 3.682 sq in 2.875 sq in
Maximum Hook Load/Tensile Strength 405,000 lbs 316,200 lbs
Slip Crushing / Slip Type (SDML) 337,400 lbs 265,600 lbs
Burst Pressure 20,625 psi 17,240 psi
Collapse Pressure 21,050 psi 17,940 psi
Torsional Yield Strength 27,560 ft-lbs 21,310 ft-lbs
Capacity 0.309 US gal/ft 0.309 US gal/ft
Displacement 0.191 US gal/ft 0.149 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

9/14/04
3501295135600

3-1/2” 12.95 lb/ft S-135 w / 3-1/2” WTS-6

TUBING SPECIFICATIONS
Grade S-135
Connection 3-1/2” WTS-6
Interchangeable With Hydril 3-1/2” PH-6
Upset Type External Integral
Nominal Weight per Foot 12.95 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 4.313”
Inside Diameter 2.687”
Drift 2.625”
Minimum Make-up Torque 9,000 ft-lbs
Maximum Recommend Make-up Torque 11,250 ft-lbs
Tensile Strength 582,400 lbs

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.350”
Inside Diameter 2.750” 2.750”
Wall Thickness 0.375” 0.300”
Cross Sectional Area 3.682 sq in 2.875 sq in
Maximum Hook Load/Tensile Strength 497,000 lbs 388,100 lbs
Slip Crushing / Slip Type (SDML) 414,100 lbs 326,000 lbs
Burst Pressure 25,300 psi 21,160 psi
Collapse Pressure 25,830 psi 22,010 psi
Torsional Yield Strength 33,820 ft-lbs 26,160 ft-lbs
Capacity 0.309 US gal/ft 0.309 US gal/ft
Displacement 0.191 US gal/ft 0.149 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
3501580080600

3-1/2” 15.80 lb/ft L-80 / N-80 w / 3-1/2” WTS-6

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 3-1/2” WTS-6
Interchangeable With Hydril 3-1/2” PH-6
Upset Type External Integral
Nominal Weight per Foot 15.80 lb/ft

TOOL JOINT AND CONNECTION DATA


Outside Diameter 4.500”
Inside Diameter 2.485”
Drift 2.423”
Minimum Make-up Torque 5,500 ft-lbs
Maximum Recommend Make-up Torque 6,875 ft-lbs
Tensile Strength 411,000 lbs

TUBE DATA
New Premium
Outside Diameter 3-1/2” 3.310”
Inside Diameter 2.548” 2.548”
Wall Thickness 0.476” 0.381”
Cross Sectional Area 4.522 sq in 3.504 sq in
Maximum Hook Load/Tensile Strength 361,800 lbs 280,300 lbs
Slip Crushing / Slip Type (SDML) 301,400 lbs 236,000 lbs
Burst Pressure 19,040 psi 16,110 psi
Collapse Pressure 18,800 psi 16,300 psi
Torsional Yield Strength 23,290 ft-lbs 17,760 ft-lbs
Capacity 0.265 US gal/ft 0.265 US gal/ft
Displacement 0.235 US gal/ft 0.182 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
4501550080600

4-1/2” 15.50 lb/ft L-80 / N-80 4-1/2” WTS-6

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 4-1/2” WTS-6
Interchangeable With Hydril 4-1/2” PH-6
Upset Type External Integral
Nominal Weight per Foot 15.50 lb/ft

TOOL JOINT AND CONNECTION DATA


Outside Diameter 5.125”
Inside Diameter 3.765”
Drift 3.701”
Minimum Make-up Torque 6,000 ft-lbs
Maximum Recommend Make-up Torque 7,500 ft-lbs
Tensile Strength 370,700 lbs

TUBE DATA
New Premium
Outside Diameter 4-1/2” 4.365”
Inside Diameter 3.826” 3.826”
Wall Thickness 0.337” 0.270”
Cross Sectional Area 4.407 sq in 3.469 sq in
Maximum Hook Load/Tensile Strength 352,600 lbs 277,500 lbs
Slip Crushing / Slip Type (SDML) 278,200 lbs 220,600 lbs
Burst Pressure 10,480 psi 8,650 psi
Collapse Pressure 11,080 psi 7,880 psi
Torsional Yield Strength 32,860 ft-lbs 25,750 ft-lbs
Capacity 0.597 US gal/ft 0.597 US gal/ft
Displacement 0.229 US gal/ft 0.180 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
4501550110600

4-1/2” 15.50 lb/ft P-110 w / 4-1/2” WTS-6

TUBING SPECIFICATIONS
Grade P-110
Connection 4-1/2” WTS-6
Interchangeable With Hydril 4-1/2” PH-6
Upset Type External Integral
Nominal Weight per Foot 15.50 lb/ft

TOOL JOINT AND CONNECTION DATA


Outside Diameter 5.125”
Inside Diameter 3.765”
Drift 3.701”
Minimum Make-up Torque 7,500 ft-lbs
Maximum Recommend Make-up Torque 9,375 ft-lbs
Tensile Strength 509,800 lbs

TUBE DATA
New Premium
Outside Diameter 4-1/2” 4.365”
Inside Diameter 3.826” 3.826”
Wall Thickness 0.337” 0.270”
Cross Sectional Area 4.407 sq in 3.469 sq in
Maximum Hook Load/Tensile Strength 484,800 lbs 381,600 lbs
Slip Crushing / Slip Type (SDML) 382,500 lbs 303,300 lbs
Burst Pressure 14,420 psi 11,890 psi
Collapse Pressure 14,340 psi 9,750 psi
Torsional Yield Strength 45,190 ft-lbs 35,400 ft-lbs
Capacity 0.597 US gal/ft 0.597 US gal/ft
Displacement 0.229 US gal/ft 0.180 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04
4501550135600

4-1/2” 15.50 lb/ft S-135 w / 4-1/2” WTS-6

TUBING SPECIFICATIONS
Grade S-135
Connection 4-1/2” WTS-6
Interchangeable With Hydril 4-1/2” PH-6
Upset Type External Integral
Nominal Weight per Foot 15.50 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 5.125”
Inside Diameter 3.765”
Drift 3.701”
Minimum Make-up Torque 8,500 ft-lbs
Maximum Recommend Make-up Torque 10,625 ft-lbs
Tensile Strength 625,600 lbs

TUBE DATA
New Premium
Outside Diameter 4-1/2” 4.365”
Inside Diameter 3.826” 3.826”
Wall Thickness 0.337” 0.270”
Cross Sectional Area 4.407 sq in 3.469 sq in
Maximum Hook Load/Tensile Strength 595,000 lbs 468,300 lbs
Slip Crushing / Slip Type (SDML) 469,400 lbs 372,200 lbs
Burst Pressure 17,690 psi 14,590 psi
Collapse Pressure 16,770 psi 11,000 psi
Torsional Yield Strength 55,450 ft-lbs 43,450 ft-lbs
Capacity 0.597 US gal/ft 0.597 US gal/ft
Displacement 0.229 US gal/ft 0.180 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information. All information is
for guidelines and the data described are at the users risk and are the user’s
responsibility. All products are subject to Weatherford’s standard sales
warranty, a copy of which is available upon request.

CAUTION: As the steel strength grade increases, the steel’s susceptibility to


corrosion cracking or hydrogen embrittlement increases. S-135 is the
highest strength tubing and thus the most susceptible to corrosion and
hydrogen embrittlement. It is the responsibility of the operator to maintain a
suitable well environment is which S-135 tubing is run to avoid stress
cracking or hydrogen environment. If the well environment cannot be
maintained at a suitable level, a lower grade of tubing should be used. The
tubing grade is the sole decision and responsibility of the operator.

9/14/04
4501920080600

4-1/2” 19.20 lb/ft L-80 / N-80 w / 4-1/2” WTS-6

TUBING SPECIFICATIONS
Grade L-80 / N-80
Connection 4-1/2” WTS-6
Interchangeable With Hydril 4-1/2” PH-6
Upset Type External Integral
Nominal Weight per Foot 19.20 lbs

TOOL JOINT AND CONNECTION DATA


Outside Diameter 5.313”
Inside Diameter 3.560”
Drift 3.515”
Minimum Make-up Torque 7,500 ft-lbs
Maximum Recommend Make-up Torque 9,000 ft-lbs
Tensile Strength 465,300 lbs

TUBE DATA
New Premium
Outside Diameter 4-1/2” 4.328”
Inside Diameter 3.640” 3.640”
Wall Thickness 0.430” 0.344”
Cross Sectional Area 5.498 sq in 4.306 sq in
Maximum Hook Load/Tensile Strength 439,900 lbs 344,400 lbs
Slip Crushing / Slip Type (SDML) 347,000 lbs 274,300 lbs
Burst Pressure 13,380 psi 11,130 psi
Collapse Pressure 13,830 psi 11,710 psi
Torsional Yield Strength 39,360 ft-lbs 30,600 ft-lbs
Capacity 0.541 US gal/ft 0.541 US gal/ft
Displacement 0.286 US gal/ft 0.224 US gal/ft

Excessive heat or pulling when tube is torqued can cause the maximum pull
to decrease.

Where possible all figures are obtained from OEM data source.

NOTE: Weatherford in no way assumes responsibility or liability for any loss,


damage or injury resulting from the use of the information listed above. All
applications are for guidelines and the data described are at the user’s own
risk and are the user’s responsibility.

9/14/04