AS-Interface Power24: The Simple Wiring

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

AS-Interface Power24

The simple wiring.

www.AS-Interface.net

AS-Interface Power24
AS-Interface Power24 Uses the existing power supply and offers a cost effective start to automation Benefits Application Availability and support Technology

www.AS-Interface.net

Benefits AS-Interface
AS-Interface replaces old wiring technology Quick installation
Reduced wiring efforts around 40%

Quick start up
Simple test and diagnosis

One single cable


A single cable for data and power

Reduced wiring mistakes


Less clamp positions and mechanical reverse polarity protection

Better diagnosis
Errors are easily located, diagnostic information is available
www.AS-Interface.net

Benefits AS-Interface Power24


Comparing Costs
Costs

Power24

Savings

Number of I/O Points Costs Savings

AS-Interface

Number of I/O points Cost effective start


www.AS-Interface.net

Benefits AS-Interface Power24


User benefit AS-Interface Power24:
Low entry cost Reduced size Supply by 24V makes it independent from local power network (50/60 Hz. 110V, 230V, 400V) Decentral switchcabinet for gateways
Smaller switchcabinet

Start of communication for even less

www.AS-Interface.net

Application
AS-Interface Power24 Optimized for compact applications
Small machines Facilities with few I/O points Compact complex facilities Networked islands (typical local bus) For field and switch cabinets

Replaces the classic application of passive distributers

www.AS-Interface.net

Application
AS-Interface has now economic advantage for the local traffic Reduced beginners efforts for short cable length. Use of existing 24V power supply for ASInterface network. Easy to extend to full distance and power

www.AS-Interface.net

Availability and support


Wide product range and more than 300 members worldwide

www.AS-Interface.net

Availability and support


Availability: More than 1500 certified AS-Interface products More than 16 Million AS-Interface devices in the field More than 300 Million Euro annual sales More than 600,000 safety devices in the field

www.AS-Interface.net

Availability and support


Support: All common Fieldbus systems (e.g. PROFIBUS, PROFINET, Ethernet IP, CC-Link, DeviceNet, Modbus) Local organizations (China, Germany, Italy, Japan, USA) Manufacturer neutral certification

www.AS-Interface.net

Technologie
Technical Data AS-Interface Power24
System Network topology Cable Max. number Master Slave with cyclic Polling Free Topology (tree, line, ring, star) Cable two wire for data and power, no shielding 62 devices 992 I/O points (e.g. 496 In- and 496 Outputs or 832 In- and 160 Outputs) 50 m. With AS-Interface power supply, 500 m IEC 62026-2 1 cycle maximum 5ms Up to 8A on the bus cable Typical 24 VDC at the outputs using AS-Interface power supply Typical <24 VDC at the outputs using Power24 technology Residual error propability <10-14, at bit error rate of 10-4

Network length Standard Reaction time Power supply Power supply Data consistency
www.AS-Interface.net

Technology
Necessary devices: AS-Interface Master / Gateway
Handles the communication to the devices connected, is implemented in the PLC like a common I/O module

AS-Interface power supply / data decoupling unit


Power24 data decoupling unit (can be integrated to Master or other devices), uses existing 24V power supply, reduced network length, reduced voltage at the outputs AS-Interface power supply (data decoupling unit integrated), full network distance and more Power available at the outputs

www.AS-Interface.net

Technology
Necessary devices: AS-Interface devices
AS-Interface devices capable of using Power24 technology are marked by the manufacturers with the Power24 logo.

AS-Interface cable
Yellow flat cable (reverse polarity protection), Advantage: vampire technology can be used, stripping and cutting to length is omitted Regular cable e.g. : H05VV-F 2x1,5 can be used, different transmission characteristics influence the available network length

www.AS-Interface.net

Technoloy
Necessary devices: Earth fault detection
In case IEC 60204-1 is applicable an earth fault detection has to be used (Mostly integrated to master or power supply)

www.AS-Interface.net

Technology
Power24
Secondary grounding not allowed!

AS-i + 24 V DC ripple max. 250mV AS-i Data decoupling unit Maximum network length 50m AS-Interface Master / Gateway

AS-i +

AS-i -

AS-i Slave
www.AS-Interface.net

AS-i Slave

AS-i Slave

Up to 62 AS-i Slave connectable

AS-i Slave

Uout <24V, (U=R*I)

Technologie
AS-Interface
AS-i +

AS-i AS-Interface power supply Network length 100m, Extendable by impedance and repeater AS-Interface Master / Gateway

AS-i +

AS-i -

AS-i Slave
www.AS-Interface.net

AS-i Slave

AS-i Slave

Up to 62 AS-i Slave connectable

AS-i Slave

Uout typical 24 V, (U=R*I)

AS-Interface
AS-Interface optimizes: Efforts of project planning Installation time Marking efforts Time for testing Start up Documentation Efforts for diagnosis Maintenance time

www.AS-Interface.net

AS-Interface
AS-Interface Power24 Network length up to 50m Use of existing 24 VDC power supply

www.AS-Interface.net

More information:
www.as-interface.net www.as-i.mobi
AS-International Association Tel: +49 6051 473212 E-Mail: info@as-interface.net

www.AS-Interface.net