AS-Interface Power24: The Simple Wiring
AS-Interface Power24: The Simple Wiring
AS-Interface Power24: The Simple Wiring
www.AS-Interface.net
AS-Interface Power24
AS-Interface Power24 Uses the existing power supply and offers a cost effective start to automation Benefits Application Availability and support Technology
www.AS-Interface.net
Benefits AS-Interface
AS-Interface replaces old wiring technology Quick installation
Reduced wiring efforts around 40%
Quick start up
Simple test and diagnosis
Better diagnosis
Errors are easily located, diagnostic information is available
www.AS-Interface.net
Power24
Savings
AS-Interface
www.AS-Interface.net
Application
AS-Interface Power24 Optimized for compact applications
Small machines Facilities with few I/O points Compact complex facilities Networked islands (typical local bus) For field and switch cabinets
www.AS-Interface.net
Application
AS-Interface has now economic advantage for the local traffic Reduced beginners efforts for short cable length. Use of existing 24V power supply for ASInterface network. Easy to extend to full distance and power
www.AS-Interface.net
www.AS-Interface.net
www.AS-Interface.net
www.AS-Interface.net
Technologie
Technical Data AS-Interface Power24
System Network topology Cable Max. number Master Slave with cyclic Polling Free Topology (tree, line, ring, star) Cable two wire for data and power, no shielding 62 devices 992 I/O points (e.g. 496 In- and 496 Outputs or 832 In- and 160 Outputs) 50 m. With AS-Interface power supply, 500 m IEC 62026-2 1 cycle maximum 5ms Up to 8A on the bus cable Typical 24 VDC at the outputs using AS-Interface power supply Typical <24 VDC at the outputs using Power24 technology Residual error propability <10-14, at bit error rate of 10-4
Network length Standard Reaction time Power supply Power supply Data consistency
www.AS-Interface.net
Technology
Necessary devices: AS-Interface Master / Gateway
Handles the communication to the devices connected, is implemented in the PLC like a common I/O module
www.AS-Interface.net
Technology
Necessary devices: AS-Interface devices
AS-Interface devices capable of using Power24 technology are marked by the manufacturers with the Power24 logo.
AS-Interface cable
Yellow flat cable (reverse polarity protection), Advantage: vampire technology can be used, stripping and cutting to length is omitted Regular cable e.g. : H05VV-F 2x1,5 can be used, different transmission characteristics influence the available network length
www.AS-Interface.net
Technoloy
Necessary devices: Earth fault detection
In case IEC 60204-1 is applicable an earth fault detection has to be used (Mostly integrated to master or power supply)
www.AS-Interface.net
Technology
Power24
Secondary grounding not allowed!
AS-i + 24 V DC ripple max. 250mV AS-i Data decoupling unit Maximum network length 50m AS-Interface Master / Gateway
AS-i +
AS-i -
AS-i Slave
www.AS-Interface.net
AS-i Slave
AS-i Slave
AS-i Slave
Technologie
AS-Interface
AS-i +
AS-i AS-Interface power supply Network length 100m, Extendable by impedance and repeater AS-Interface Master / Gateway
AS-i +
AS-i -
AS-i Slave
www.AS-Interface.net
AS-i Slave
AS-i Slave
AS-i Slave
AS-Interface
AS-Interface optimizes: Efforts of project planning Installation time Marking efforts Time for testing Start up Documentation Efforts for diagnosis Maintenance time
www.AS-Interface.net
AS-Interface
AS-Interface Power24 Network length up to 50m Use of existing 24 VDC power supply
www.AS-Interface.net