1 Where flexible tubing is used to encased the conductors, 6.

4 mm
the tubing shall extend from the last insulating support to
no less than _______ inside the nonmetallic boxes.

2 For voltages above 600 V, the minimum insulation 1,000,000 ohms


resistance shall be _____---____. per kilovolt
rating

3 In an eight unit apartment building, each kitchen contains 21 kVA


a 3.5 kW 240 volt electric range. The demand load for the
electric service to the building must include an allowance
for the minimum demand load of all of the ranges, which
would be ______.

4 What is the maximum number of overcurrent devices As many as will


permitted in a panelboard? fit

5 What is the minimum allowable length of a concrete- 20 feet


encased electrode?

6 The disconnecting means of a hermetic-type refrigerator 115%


compressor shall have an ampacity of at least _____ of the
nameplate full load current.

7 The working clearance between live parts for a system 3 feet


operating at 480 volts with exposed live parts on one side
and no live or grounded parts on the other side of the
working space must be a minimum of:

8 Flexible cords and cables shall not be used ______. to run through
holes in floors
9 All switches and circuit breakers, used as switches under A readily
normal operation, must be so located that they may be accessible
operated from: place

10 A fellow electrician is not breathing after receiving an Start artificial


electrical shock, but is no longer in contact with the respiration
electricity, what is the most important thing for you to do? immediately

11 A project requires the installation of twelve 1.4 ampere, 0 amps


120 volt, fluorescent lights fixtures on two 20 amp branch
circuits, as well as three 120 volt, 5.6 ampere electric fans
on individual circuits in a building with a 120/240 single
phase three-wire electric service. The minimum neutral
current allowed for these loads is -------_______.

12 Type FCC cable, cable connectors, and insulating ends 36”


shall be covered with carpet squares no larger than _____
square.

13 Wiring systems in wet locations should be _____. placed so a


permanent air
space
separates them
from the
supporting
surface
14 Branch circuit conductors supplying information 125 percent of
technology equipment shall have an ampacity of: the computed
load

15 Where must metal panelboards be protected against Both inside and


corrosion? outside
16 Service drop conductors not in excess of 600 volts shall 15
have a minimum clearance of ______ feet over residential
property and driveways, and those commercial areas not
subject to truck traffic.

17 Low voltage equipment in a hospital that comes in all of the


frequent contact with people’s bodies must be ______. choices

18 Fixtures shall be so constructed that adjacent combustible 90


material will not be subject to temperature in excess of
______ degrees C.

19 When administering first aid to a worker suffering from Cover the


fright as a result of falling from a ladder, what is the most person and
important thing to do? keep the
person warm

20 Service conductors shall not be connected to the service Solder only


disconnecting means with:

21 Potential transformers, and other switchboard devices 15


with potential coils shall be supplied by a circuit that is
protected by standard overcurrent devices rated ____
amperes or less.

22 If a co-worker is burned by acid from a storage battery, the proper water and
first aid treatment is to wash with ______. apply Vaseline

23 Which of the following systems and materials is not Metal


permitted to be used as a grounding electrode? underground
gas piping

24 The minimum spacing between bare metal 600-volt 1 inch


current-carrying parts and ground is:
25 What is the maximum overcurrent device rating allowed for 15 amperes
the protection of panelboard instrument circuits?

26 What type of front must be used for panelboard Dead-front


enclosures?

27 What is the maximum number of overcurrent devices 42


allowed in the lighting and appliance panel board?

28 All metal enclosures for service conductors and equipment Grounded


must be:

29 A continuous electrical load is one where the maximum 3 hours


current is expected to continue for minimum duration of
time. What is this minimum duration of time?

30 Which of the following is not one of the considerations that Longevity


must be evaluated in judging equipment?

31 Instrument pilot lights and potential transformers shall be 15


protected by OCD of ______ amps or less.

32 On busway installations, fused switches and circuit A suitable


breakers may be located at the same level as the busway means is
provided: provided to
operate the
device from
floor level
33 The information most useful in preventing the recurrence the cause of the
of a similar type accident when making out an accident accident
report would be ______.

34 Panelboards must be mounted in: Any of the


choices

35 A 400-ampere electric service is normally metered with a current


combination of a watt-hour meter and _______. transformer

36 Receptacles in patient care areas of pediatric locations Tamper


must be: resistant

37 An underground pull box used for circuits of over 600 volts 100
shall have the cover locked, bolted or screwed on, or the
cover is required to weigh over ______ pounds.

38 Ground fault protection for personnel on a 120 volt single- unbalanced


phase circuit is based on _______. current
between the
grounded and
ungrounded
conductor
39 Lighting that is required for a hoist pit shall meet which of It will not be
the following requirements? connected to
the load side of
the ground-
fault circuit
interrupter
40 Raceways or cable trays containing electric conductors all of the
shall not contain _____. choices

41 Artificial respiration after a severe electrical shock is stoppage of


necessary when the shock results in _________. breathing
42 Although enclosed, a service disconnecting means must Manually or
still be: power operable

43 What is the minimum size grounded system conductor 8 AWG copper


permitted by the PEC?

44 The highest current rating of an Edison-base plug fuse is: 30 amperes

45 For rigid steel conduit of trade diameter 50mm, the field 300 mm
bend shall be so made that the radius of the inner edge
shall not be less than a certain radius for conductors
without lead sheathed. What is the radius?

46 A dwelling unit is ________. One or more


rooms used as
a housekeeping
unit and having
permanent
cooking and
sanitation
provisions.
47 A single-family dwelling unit sits at grade level and has one 4
bathroom, an attached garage, and an unfinished
basement with a furnace, washer and dryer, and the
electrical service panel. Based on one ground-fault circuit-
interrupter device used to protect all of the receptacles on
the GFCI circuit, what is the minimum number of 125 volt
GFCI devices required in this dwelling?

48 Which of the following is not a requirement for an intersystem Contains at


bonding termination? least 50
percent bronze
or brass
49 In a single phase, 3-wire 120/240 volt service entrance, 14 amperes
where the hot conductor current is 28 amperes on the first
leg and 42 amperes on the second leg, the current in the
neutral will be ______.

50 In order to prevent a safety hazard an electrician should strike a


never ______. hardened steel
surface with a
hardened steel
hammer