Referee Time 1000 Aging Rate 3 Capactiance 100.0E-9 Tolerance K Capactiance Nom K Lower K Upper Test Time (HRS) Aging Factor
Referee Time 1000 Aging Rate 3 Capactiance 100.0E-9 Tolerance K Capactiance Nom K Lower K Upper Test Time (HRS) Aging Factor
Referee Time 1000 Enter as hours. (typ X5R: 48, X7R: 1000) 1
6
0
0
4
0
0
.
.
0
0
0
0
E
E
E
-
-
9
40 .0 0E -9
20 .0 0E -9
0 .0 0E +0
Aging Rate 3
1
Capactiance
Test Time Aging
Nom K Lower K Upper
(hrs) Factor
0.0001 1.210 121.00E-9 108.90E-9 133.10E-9
0.001 1.180 118.00E-9 106.20E-9 129.80E-9
0.010 1.150 115.00E-9 103.50E-9 126.50E-9
0.100 1.120 112.00E-9 100.80E-9 123.20E-9
1 1.090 109.00E-9 98.10E-9 119.90E-9
10 1.060 106.00E-9 95.40E-9 116.60E-9
100 1.030 103.00E-9 92.70E-9 113.30E-9
1,000 1.000 100.00E-9 90.00E-9 110.00E-9
10,000 0.970 97.00E-9 87.30E-9 106.70E-9
100,000 0.940 94.00E-9 84.60E-9 103.40E-9
48 1.040 103.96E-9 93.56E-9 114.35E-9
Aging Factor = 1 + ( Aging Rate ) ( Log ( Referee Time in Hrs ) - Log ( Test Time in Hrs ) )
The plots and projections revealed within are intended as a guide to typical responses and are not intended to define
absolute behavior limits of any capacitors of like description. All information provided as-is.
More tools available at: https://ec.kemet.com/
Version 1.0
C a p a c it a n c e
Ag ing C u rve
No m K Lo w er K Up pe r
1 40 .0 0E -9
1 20 .0 0E -9
1 00 .0 0E -9
80 .0 0E -9
60 .0 0E -9
40 .0 0E -9
20 .0 0E -9
0 .0 0E +0
1 10 10 0 1 ,0 00 10 ,00 0 10 0,0 0 0
H ours