Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Pipeng Toolbox : PR-3-805 RSTRENG Level 0 Corrosion Defect Screening Assessment

20 inch Oil Export pipeline from CPF to PK92, 22 km // ID Anomaly 60079 // Joint number 120
Calculated By PM
23-Jul-2022 13:29:49

Calculation Results

Symbol Description Value (STD value) Unit (STD unit)


B Defect B Value 1.437592 -
Ba Defect Allowable B Value 469.8331e-3 -
ID Pipe Inside Diameter 488.95e-3 m
La Defect Allowable Length 36.60378   (36.60378e-3) mm   (m)
OD Pipe Outside Diameter 508e-3 m
Defect Depth Over Wall
d/t 76.95538   (769.5538e-3) %   (x)
Thickness Ratio
t Pipe Wall Thickness 9.525e-3 m
Defect Minimum Remaining
tmin 2.195   (2.195e-3) mm   (m)
Wall Thickness

www.pipeng.com

You might also like