Data sheet Version: 1.

Tank wall page: 1 of 6


valid from 15.09.2014

A GLS tank kit includes 4 main components:

 1) glass lined steel panels


panel thickness 2/2,5/2,99 mm 3,40/4/5/6/7/8/10/12 mm
row steel quality S 235 - DIN 17.100 (EN 10025)* S380 - S 420 - DIN 17.100 (EN 10025)*

steel type special enamelable special enamelable


recast cold rolled hot rolled
tensile strength (Rm) min. 340 N/mm2 490 N/mm² bis 620 N/mm²
gross size 1 length 1737 mm x height 1500 mm
net size 1 length 1571 mm x height 1440 mm
gross size 2 length 2260 mm x height 1500 mm
net size 2 length 2094 mm x height 1440 mm
* quality of the glass lined steel acc. proofable static

 2) panel bolts
Option „HDG-Special“ Option „V2A“
Hot-dip galvanized with PP Stainless steel V2A
bolts head (1.4301)
dimension M 12 M 12
bolts

strength category 8.8 A2-80


Tensile strength (Rm) min. 800 N/mm2 min. 800 N/mm2
Yield point Rp 0,2% min. 600 N/mm2 min. 600 N/mm2
Stainless steel V2A
nut Hot-dip galvanized (1.4301)
Stainless steel V2A
washer Hot-dip galvanized (1.4301)
gasket (EPDM) Yes Yes
Klingersil disk Yes Yes
Nut cap optional (in PP)

 3) sealant
Depending on the agreement and application, permanently elastic sealant is used for:
Panel bonding, joint connection coverage, joint seam bottom/wall, joint seam wall/roof, flange
sealing, manhole sealing, coverage of bolt heads. For the adhesion of the sealant to the
concrete and the steel necessary bonding agents (Primer), cleaners and cleaning rags are
included in our scope of supply.

Company: GLS Tanks International GmbH; Industriestraße 6, 3860 Heidenreichstein


Contact: Tel: +43286253187-0; Fax: +43286253187-820; Email: office@glstanks.com; Web: www.glstanks.com
Bank details: Bank und Sparkassen AG Waldviertel-Mitte, Sparkassenplatz 3, 3910 Zwettl;
IBAN: AT542027200000425090, BIC: SPZWAT21;
UID-Nr.: ATU67138867; Commercial register-Nr.: FN378557b; Tax-Nr.: FA Waldviertel: 213/5723
Place of jurisdiction: Gmünd, Handelsgericht Krems an der Donau
Page 1 of 6
Data sheet Version: 1.4

Tank wall page: 2 of 6


valid from 15.09.2014

 4) steel construction components


Bottom angle (at the bottom)

Purpose: connecting the tank to the foundation by the use of anchor bolts
Steel: S 235
Profile shape: L-profile
Possible dimensions: 70/70/7; 100/75/7; 120/80/10
Welding execution: EN 1090 EXC1, as per ONR 21090

Top angle (on top)

Purpose: for stiffening the panel ring on top; connection possibility for roofs
Steel: S 235
Profile shape: L-profile
Possible dimensions: 70/70/7; 100/75/7; 120/80/10; 150/75/9
Welding execution: EN 1090 EXC1, as per ONR 21090

Wind stiffener

Purpose: protect the tank against denting by wind if the tank is empty
Steel: S 235
Profile shape: flat profile
Possible dimensions: 70/6; 80/8; 100/8; 100/10; 100/12; 120/10; 140/10; 160/10
Welding execution: EN 1090 EXC1, as per ONR 21090

 

Company: GLS Tanks International GmbH; Industriestraße 6, 3860 Heidenreichstein


Contact: Tel: +43286253187-0; Fax: +43286253187-820; Email: office@glstanks.com; Web: www.glstanks.com
Bank details: Bank und Sparkassen AG Waldviertel-Mitte, Sparkassenplatz 3, 3910 Zwettl;
IBAN: AT542027200000425090, BIC: SPZWAT21;
UID-Nr.: ATU67138867; Commercial register-Nr.: FN378557b; Tax-Nr.: FA Waldviertel: 213/5723
Place of jurisdiction: Gmünd, Handelsgericht Krems an der Donau
Page 2 of 6
Data sheet Version: 1.4

Tank wall page: 3 of 6


valid from 15.09.2014

other:
a) Anchor bolts
The choice of the anchor bolts is done by the GLS Tanks International GmbH and is based on
the static requirements, the installation location and customer needs.

b) Levelling shims
To compensate the tolerated unevenness of the foundation a certain amount of levelling shims
made of steel or galvanized steel is included.

c) Center point sheets


Thin stainless steel plates which are located in the overlapping area of 4 panels, in order to
guarantee a metal seal.

d) nameplate
Every tank is equipped with a nameplate mentioning following details:
 project number of the GLS Tanks International GmbH (E - number)
 tank diameter
 tank heigth
 net volume
 content or tank type

e) GLS Logo
In case of non-insulated tanks the GLS logo is adhered to a panel. We can offer you to adhere
your leocustomer’s logo on request.

f) Warning signs
 For silos with risk of suffocation
 For tank in tank solutions
The client is responsible for any other warning signs!

Company: GLS Tanks International GmbH; Industriestraße 6, 3860 Heidenreichstein


Contact: Tel: +43286253187-0; Fax: +43286253187-820; Email: office@glstanks.com; Web: www.glstanks.com
Bank details: Bank und Sparkassen AG Waldviertel-Mitte, Sparkassenplatz 3, 3910 Zwettl;
IBAN: AT542027200000425090, BIC: SPZWAT21;
UID-Nr.: ATU67138867; Commercial register-Nr.: FN378557b; Tax-Nr.: FA Waldviertel: 213/5723
Place of jurisdiction: Gmünd, Handelsgericht Krems an der Donau
Page 3 of 6
Data sheet Version: 1.4

Tank wall page: 4 of 6


valid from 15.09.2014

Glass lining:
Steel segments are made to glass lined panels because of the enameling according to the
guideline of the European Enamel Authority (EEA). This is done in our factory in AUSTRIA,
A-3860 Heidenreichstein. Link: http://www.european-enamel-authority.org

The certificate can be found on our website. This certificate entitles to enamel tanks for
industrial, commercial purposes, silos for animal feed and manure silos.

In most cases the steel surface must be environmental harmful


pretreated before enameling, but not with modern technic and special
types of steel. With the PUESTA method the enamel powder is applied
onto the steel sheets by electrostatic charging. The charging of the
enamel powder is done by ion atmospheric components which are
formed by a corona discharge at the tip of a spray pistol. 45-100 kV are
applied between the pistol and the earthed work piece. The enamel parts
move preferably along the electric field lines to the panel. A for the
production process sufficient adhesion of the powder is caused by
electrostatic forces. A too fast discharge is prevented by the special preparation of the
powders. The special advantage of the electrostatic enamel powder application is the ability to
achieve a particularly high resistance to mechanical stress of the enameled panel with reduced
but uniform layer thicknesses. After that the panel with the powder applied comes into the
enameling oven. The enamel powder melts with the steel at about 840°C to a strong and
permanent fusion.

Monoglass
 According to guideline EEA 7.24 „silos for animal feed“
 According to guideline der EEA 7.25 „manure silos“
 one layer – one burning process
 color: blue similar RAL 5004 (blue-black)
 layer thickness acc. standard: 0,18 mm to 0,5 mm
 5 defects per squaremeter allowed on the inside

Uniglass
 According to guideline EEA 7.20 „tanks for industrial purpose“
 Two layeres – two burning processes
 colors: blue similar RAL 5004 (blue-black)
white similar RAL 9010 (pure white)
green similar RAL 6020 (chrome green)
 layer thickness acc. standard: 0,18 mm to 0,5 mm
 No defects allowed on the inside
Ultraglass
 According to guideline EEA 7.20 „tanks for industrial purpose“
 One layer – one burning process with HR Ultra Enamel (High Resistant)
 color: blue similar RAL 5004 (blue-black)
 layer thickness acc. standard: 0,18 mm to 0,5 mm
 No defects allowed on the inside

Company: GLS Tanks International GmbH; Industriestraße 6, 3860 Heidenreichstein


Contact: Tel: +43286253187-0; Fax: +43286253187-820; Email: office@glstanks.com; Web: www.glstanks.com
Bank details: Bank und Sparkassen AG Waldviertel-Mitte, Sparkassenplatz 3, 3910 Zwettl;
IBAN: AT542027200000425090, BIC: SPZWAT21;
UID-Nr.: ATU67138867; Commercial register-Nr.: FN378557b; Tax-Nr.: FA Waldviertel: 213/5723
Place of jurisdiction: Gmünd, Handelsgericht Krems an der Donau
Page 4 of 6
Data sheet Version: 1.4

Tank wall page: 5 of 6


valid from 15.09.2014

Panel edges:

Rounded edges
We have the possibility to round the edges before enameling to prevent damage from
improper installation. This ensures also that the edges are better sourrounded by the enamel.

Example picture rounded edges

Edge protection
As transport and corrosion protection the panel edges are covered with sealant in the factory
(WITHOUT EXTRA COSTS). This type of edge protection is especially important for long
transport distances or long storage times.

Example picture edge protection

Company: GLS Tanks International GmbH; Industriestraße 6, 3860 Heidenreichstein


Contact: Tel: +43286253187-0; Fax: +43286253187-820; Email: office@glstanks.com; Web: www.glstanks.com
Bank details: Bank und Sparkassen AG Waldviertel-Mitte, Sparkassenplatz 3, 3910 Zwettl;
IBAN: AT542027200000425090, BIC: SPZWAT21;
UID-Nr.: ATU67138867; Commercial register-Nr.: FN378557b; Tax-Nr.: FA Waldviertel: 213/5723
Place of jurisdiction: Gmünd, Handelsgericht Krems an der Donau
Page 5 of 6
Data sheet Version: 1.4

Tank wall page: 6 of 6


valid from 15.09.2014

Static design:

Static design of the tank wall according DIN 18800, Part 1 „Steel structures – Design and
construction“ and EN 28765 „Vitreous and porcelain enamels – Design of bolted steel tanks for
storage or treatment of water or municipal or industrial effluents and sludges“.

Calculation of earthquake loads according DIN 4149 „earthquake design loads“ in combination
with Eurocode 8 „Design of structures for earthquake resistance“ or on request according
AWWA D103/09 „Standard for Factory-Coated Bolted Steel Tanks for Water Storage“.

The proofable static of GLS Tanks does not only consider the filled condition incl. the pressure
conditions but also the buckling caused by wind in case the tank is empty!!!

It is not allowed to place a tank in another tank, unless it is specifically allowed in the contract.

The calculation of the proofable static is based on following load information:

 Specific weight of medium


 Minimum freeboard
 Wind load
 Snow load
 Maximum soil acceleration factor for earthquakes
 Loads of the roof in case it is not from GLS (incl. snow load)
 Average biogas pressure
 Maximum biogas pressure
 Maximum vacuum in the tank
 Mixer loads of central mixers on the roof
 other*

* other: Loads of on-site attachements may not be induced or only after consultion with GLS.
Only the loads mentioned in the quotations load data are calculated in the quotation and
therefore also in the proofable static.

Following varies depending on the provided load information:

 panel thickness
 size and execution of the bottom and top angles
 size, execution and quantity of wind stiffeners
 quantity and execution of anchor bolts
 size of the roof beams for the glass lined roof

It is important to know that not only the thickness of the panels is crucial for the strength of
the tank. You always have to pay attention to the design of the steel structures.

Company: GLS Tanks International GmbH; Industriestraße 6, 3860 Heidenreichstein


Contact: Tel: +43286253187-0; Fax: +43286253187-820; Email: office@glstanks.com; Web: www.glstanks.com
Bank details: Bank und Sparkassen AG Waldviertel-Mitte, Sparkassenplatz 3, 3910 Zwettl;
IBAN: AT542027200000425090, BIC: SPZWAT21;
UID-Nr.: ATU67138867; Commercial register-Nr.: FN378557b; Tax-Nr.: FA Waldviertel: 213/5723
Place of jurisdiction: Gmünd, Handelsgericht Krems an der Donau
Page 6 of 6