Professional Documents
Culture Documents
CM 06 - Pre-Loading - Discharging Checklist
CM 06 - Pre-Loading - Discharging Checklist
15. If there is any doubt of the Lifting Heights, Outreach then the √
Stow or Lift Plan needs reconsideration/calculation
16. Any adjustment of outreach warrants confirmation that √
Crane Capacity is adequate
17. Ensure adequate capacity of Heeling Tanks is available & √
anti-heeling system is tested before start of operations.
18. Has draft been physically verified and corresponds with √
calculated displacement and Capacity Plan?
19. Where used, does the Stabilizer Pontoon Draft allow for N/A
change in draft during the operation?
20. Are Stabilizer Pontoon Valves & Securing arrangements in N/A
correct position after rigging?
21. Are Ballast & Anti-Heeling operations assigned to a √
responsible Officer?
22. Are vessel’s and lighter’s (where applicable) Moorings & √
Accommodation Ladders attended to?
23. Are the Taluretted/Spliced Ends of Grommets and Slings √
outside of hooks and shackles? There must NOT be a bend in
these areas
24. Ensure Communication Equipment fixed and walkie-talkies √
are in good working order and batteries full charged
25. Consideration given to non-essential personnel being N/A
disembarked from the vessel during a Super Heavy lift.
26. Verify Master is working with the most up to date versions √
of the documents. Verify method statement, lifting plan
Cargo information load/discharge procedure.
27. In cases where no CSI is in attendance the Master is to √
acknowledge with HHL head office Cargo Management
which version of the plans he is working from.
28. Where necessary reference is made to HHL head office for √
lifts to proceed. This would include any situation where
equipment or systems are not fully functional.
29. Are all deck cargo stowage arrangements in place PRIOR √
cargo being lifted onboard?
30. Cargo already onboard is adequately lashed / secured before √
attempting further lifts.
31. Proper barriers have been erected to prevent personnel √
unauthorized access to holds and hatch covers during the lift.
32. CSI specific check of heeling tank capacities and √
calculations for expected transfer to enable righting of the
vessel through all stages of lift without need to transfer
ballast.
33. All mooring ropes shall have valid certificates and shall not √
be spliced at any part of their length.
34. Ballast tank soundings have been checked by manual √
CM 06 – Pre-Loading – Discharging Checklist Page 3 of 4
Document No: ORG-CARGO-01-CM06
Document Revision./Date 1 / 2016-09-22
Prepared / Reviewed / Released: Cargo Management / Head of QHSE / DPA
HANSA HEAVY LIFT GmbH Internal use only
39. Check that slings are secured against slipping for lift of √
floating units in belly lift configuration?.
Engine Department
40. Check all safety devices in working condition? Any √
‘bridging’ must have the approval of Fleet Department.
41. Check and confirm there are NO EARTH FAULTS on the √
MSB and ESB including DC switchboards.
42. Confirm Remote Control Devices / Control Monitors are √
fully operational?
43. Verify that Diesel Generator’s Fuel & L.O. Filters changed √
over and cleaned and that D/G’s are tested and confirmed
with log entry as able to provide minimum 80% of full load?
44. Is a Stand-By D/G where applicable available ready and on √
STAND-BY?
45. Check, test and ensure: √
- Ballast Pumps are in good order.
- Anti-Heeling Pumps are in good order.
- Cross-over connection valves between Ballast / Ant-
Heeling / SW Pumps where fitted are known and operational.
Deck and Engine Departments
46. Ensure ALL SAFETY FUNCTIONS / REMOTE STOPS & √
ALARMS of Deck Cranes are fully operational, tested and
log entries made prior to HL operations.
47. Ensure Bunker / LO / FW is correctly entered in the Loading √
Program and Soundings Log. Do not rely on remote readings
CM 06 – Pre-Loading – Discharging Checklist Page 4 of 4
Document No: ORG-CARGO-01-CM06
Document Revision./Date 1 / 2016-09-22
Prepared / Reviewed / Released: Cargo Management / Head of QHSE / DPA
HANSA HEAVY LIFT GmbH Internal use only