Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

GRUNDFOS ALLDOS DATA BOOKLET

Vaccuperm VGA and VGB

Chlorine gas dosing systems


Dosing and Disinfection
Contents

General data
Performance diagram 3
Principle of vacuum chlorine gas dosing systems 4

Construction and function


Vaccuperm VGB-103 5
Vaccuperm VGA-111, VGA-113, VGA-146, VGA-117 6

Type key
Vaccuperm VGB-103 11
Vaccuperm VGA-111 12
Vaccuperm VGA-113 13
Vaccuperm VGA-117 13
Vaccuperm VGA-146 14

Product selection
Vaccuperm VGB-103 15
Vaccuperm VGA-111 16
Vaccuperm VGA-113 17
Vaccuperm VGA-117 18
Vaccuperm VGA-146 19

Technical data
Compact dosing unit Vaccuperm VGB-103 20
Vacuum regulator Vaccuperm VGA-111 21
Dosing regulator Vaccuperm VGA-113 23
Vacuum regulator Vaccuperm VGA-146 24
Dosing regulator Vaccuperm VGA-117 26

Further product documentation


WebCAPS 27
WinCAPS 28

2
General data VACCUPERM
Chlorine gas dosing systems

Performance diagram
equipment features

VGS

VGA

VGB

TM04 1280 1209


0 2 10 200 max. capacity (kg/h)

Fig. 1 Performance diagram Vaccuperm VGB, VGA and VGS

Please select your Vaccuperm chlorine gas dosing


system according to this diagram.

3
General data VACCUPERM
Chlorine gas dosing systems

Principle of vacuum chlorine gas dosing systems

B C

G
E

TM04 1281 1209


H
A

Fig. 2 Principle of vacuum chlorine gas dosing systems

Function of chlorine gas dosing systems A diaphragm check valve at the gas supply line prevents
Handling, transport and storage of chlorine for the the ingress of water into the vacuum line.
disinfection of drinking and pool water are a challenge to
Legend
systems engineering. This is the reason why the vacuum
principle is being used in dosing systems for a long time
already. At this, the pressure of the chlorine gas is Pos. Component

reduced to the vacuum. A Chlorine gas cylinder

This method successfully avoids chlorine gas leakage. B Vacuum regulator

In the event of a pipe breakage, no chlorine gas can C Dosing regulator

escape, only ambient air is drawn in. D Injector


E Absorption cylinder (option)
Vacuum chlorine gas dosing systems are composed of
F Safety valve (option)
three principal components.
G Change-over device (option)

Vacuum regulator (B) H Water apparatus (option)

The vacuum regulator is a pressure reducing valve, which


reduces the overpressure from the chlorine tank side to
the negative pressure on the vacuum side. The valve
opens, when a sufficient vacuum is present on the outlet
side. Vacuum regulators with pressure gauge and a liquid
trap are available for more safety.

Dosing regulator (C)


The chlorine gas volume flow is adjusted with the dosing
regulator. This can be effected manually or automatically
via motor control.
VGB models combine a vacuum regulator and a dosing
unit in a compact enclosure. They are not available with
change-over device or servomotor for dosing regulator.

Injector (D)
Injectors have the task to bring chlorine gas into the water
flow. They operate according to the principle of water jet
pumps. The injector body comprises a nozzle with a
successional diffusor. Between the nozzle and the
diffusor, there is a narrow annular gap, where chlorine gas
is sucked out of the dosing line through the injector head.

4
Construction and function VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGB-103
Compact dosing unit Vaccuperm VGB-103
• Vacuum regulator and dosing regulator in a single
unit for direct mounting on a chlorine cylinder.
• Up to 2000 g/h can be extracted. The maximum
extraction quantity depends on the chlorine cylinder
content: It is 1 % per hour of the content by weight.
For a short time (max. 10 min.) it is possible to
extract the triple of this.

TM04 1305 2609


1

Fig. 4 Vaccuperm VGB-103

2
TM04 1271 1310

TM04 1306 2609


Fig. 3 Compact unit VGB-103
Fig. 5 Vaccuperm VGB-103 with USA yoke
Legend

Pos. Component
1 Vaccuperm 103-100
2 Chlorine gas absorption cylinder
3 Injector

5
Construction and function VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGA-111, VGA-113, VGA-146, VGA-117


Dosing station for extraction from one Dosing station for extraction from one
cylinder drum
Combination of Vaccuperm VGA-111 and VGA-113 Combination of Vaccuperm VGA-146 and VGA-117
• Vacuum regulator for direct mounting on a chlorine • Vacuum regulator for wall mounting (in the drum
cylinder. room).
• Dosing regulator for separate wall mounting. • Dosing regulator for separate wall mounting.
• It is recommended to wrap a heater band around
the copper line between the container and the
vacuum regulator when using drums.

TM04 1307 1310

TM04 1309 2609


Fig. 6 Vaccuperm VGA-113 and VGA-111

Fig. 8 Vaccuperm VGA-146 and VGA-117

2 1

0 bar 16

11 1b

12 3
TM04 1274 1310
TM04 1272 1310

12 3
7 6

Fig. 7 Dosing station for extraction from one cylinder Fig. 9 Dosing station for extraction from one drum
(VGA-111 and VGA-113) (VGA-146 and VGA-117)

Pos. Component Pos. Component

1 Vacuum regulator VGA for direct mounting 1b Vacuum regulator VGA with liquid trap for wall mounting
2 Dosing regulator VGA for serial installation 2 Dosing regulator VGA for serial installation
3 Injector with diaphragm check valve 3 Injector with diaphragm check valve
6 Gas absorption cylinder 6 Gas absorption cylinder
12 Water apparatus 7 Gas sensor
8 Gas warning unit
11 Safety valve
12 Water apparatus

6
Construction and function VACCUPERM
Chlorine gas dosing systems

Dosing station for simultaneous extraction from several cylinders (full vacuum system)
Combination of several VGA-111 and VGA-113
• If more gas is required, it can be extracted from
several cylinders simultaneously.
• Vacuum regulators are installed on several chlorine
cylinders in series using T-pieces.
• Single or multiple dosing regulators for separate
installation.

1 1

0 bar 16 0 bar 16 0 bar 16 0 bar 16 0 bar 16 0 bar 16

TM04 1273 1310


12 3

Fig. 10 Dosing station for simultaneous extraction from several cylinders (VGA-111 and VGA-113)

Pos. Component
1 Vacuum regulator VGA for direct mounting
2 Dosing regulator VGA for serial installation
3 Injector with diaphragm check valve
6 Gas absorption cylinder
12 Water apparatus

7
Construction and function VACCUPERM
Chlorine gas dosing systems

Dosing station with vacuum change-over device


Combination of several VGA-111 and VGA-113
• Continuous gas dosing without interrupting the
process.
• Two vacuum regulators for mounting on gas cylinder
header lines.
• Up to 4 dosing regulators can be installed
separately.
• If the first cylinder row is empty, the change-over
device immediately changes over to the next
vacuum regulator at the full chlorine cylinder row.
• The safety valve avoids excess pressure in the
vacuum lines leaving the clinder room.

2b 2b 11

8 5 1b 4

1b 13

13
4-20 mA

3 7
TM04 1277 1310

9
12

Fig. 11 Dosing station with vacuum change-over device (VGA-111 and VGA-113)

Pos. Component
1b Vacuum regulator VGA with liquid trap for wall mounting
2b Dosing regulator VGA with electric servomotor and current input
3 Injector with diaphragm check valve
4 Vacuum change-over device
5 Empty signal display unit
6 Gas absorption cylinder
7 Gas sensor
8 Gas warning unit
9 Flowmeter with output for mA signal
11 Safety valve
12 Water apparatus
13 Header line

8
Construction and function VACCUPERM
Chlorine gas dosing systems

Dosing station for simultaneous extraction from several cylinders, if more than 4000 g/h are
required in total
Combination of several VGA-146 and VGA-117
• If more gas is required, it can be extracted form
several cylinders simultaneously.
• Vacuum regulators for mounting on header lines.
• With automatic change-over device.

2b 2a

4 11

13 13

1b 1b

10

TM04 1276 1310


9 3

12

Fig. 12 Dosing station with vacuum change-over device (VGA-146 and VGA-117)

Pos. Component
1b Vacuum regulator VGA with liquid trap for wall mounting
2 Dosing regulator VGA for serial installation
2a Dosing regulator VGA with electric servomotor
2b Dosing regulator VGA with electric servomotor and current input
3 Injector with diaphragm check valve
4 Vacuum change-over device
9 Flowmeter with output for mA signal
10 Compact measuring system
11 Safety valve
12 Water apparatus
13 Header line

9
Construction and function VACCUPERM
Chlorine gas dosing systems

Dosing station with vacuum change-over device


Combination of several VGA-146 and VGA-117
• Continuous gas dosing without interrupting the
process.
• Two vacuum regulators for mounting on chlorine
drums, liquid traps avoid the penetration of liquefied
gas.
• Several dosing regulators can be installed
separately.
• If the first drum is empty, the change-over device
immediately changes over to the next vacuum
regulator at the full chlorine drum.
• The safety valve avoids excess pressure in the
vacuum lines leaving the drum room.

2b 2a

8 5 4
11

1c 1c

10

TM04 1275 1310

12 3

7 6 7 6 9

Fig. 13 Dosing station with vacuum change-over device (VGA-146 and VGA-117)

Pos. Component
1c Vacuum regulator VGA with liquid trap for direct mounting
2 Dosing regulator VGA for serial installation
2a Dosing regulator VGA with electric servomotor
2b Dosing regulator VGA with electric servomotor and current input
3 Injector with diaphragm check valve
4 Vacuum change-over device
5 Empty signal display unit
6 Gas absorption cylinder
7 Gas sensor
8 Gas warning unit
9 Flowmeter with output for mA signal
10 Compact measuring system
11 Safety valve
12 Water apparatus

10
Type key VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGB-103
Example: Compact dosing regulator VGB-103-250/1-S-1-O, B0

Code Example VGB-103 -250 /1 -S -1 -O ,B 0

VGB Vaccuperm Gas Basic

Dosing flow
100 5 - 100 g/h
250 10 - 250 g/h
500 25 - 500 g/h
1000 50 - 1000 g/h
2000 100 - 2000 g/h
Connection
1 G1
2 G 3/4
3 yoke USA
Inlet valve
B simple
S short
Pressure indication
0 without
1 with pressure gauge
Filter
O external
U internal

B not applicable

0 not applicable

11
Type key VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGA-111
Example: Vacuum regulator VGA-111-B/1-S-0R-0-U, NF

Code Example VGA-111 -B /1 -S -0 R -0 -U ,N F


VGA Vaccuperm Gas Advanced
Installation
B directly on the chlorine gas cylinder
W wall-mounting
C on a header line
BC directly on the chlorine gas cylinder or on a header line
Connection
1 G1
2 G 3/4
3 yoke USA
4 copper pipe 6/8 mm
Inlet valve
B simple
S short
L long, 230-240V / 50-60 Hz, with liquid trap and heater
M long, 110-115V / 50-60 Hz, with liquid trap and heater
Pressure indication
0 without
1 with pressure gauge
Connection pressure gauge
X without
T top
R right-hand-side
Limiting nozzle for full vacuum systems
0 without
1 with nozzle
Filter
O external
U internal

N not applicable

F not applicable

12
Type key VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGA-113
Example: Dosing regulator VGA-113-100/M0, Y

Code Example VGA-113 -100 /M 0 -Y


VGA Vaccuperm Gas Advanced
Dosing flow
25 1-25 g/h
40 2-40 g/h
100 5-100 g/h
250 10-250 g/h
500 25-500 g/h
1000 50-1000 g/h
2000 100-2000 g/h
3000 150-3000 g/h
4000 400-4000 g/h
Adjustment
M manual
A automatic, 230-240V / 50-60 Hz (not for 25 g/h)
B automatic, 110-115V / 50-60 Hz (not for 25 g/h)
Control
0 without
1 4-20 mA input signal
2 direct control with 1000 Ohm feedback potentiometer

Y not applicable

Vaccuperm VGA-117
Example: Dosing regulator VGA-117-1000/5M0, N

Code Example VGA-117 -1000 /5 -M O ,N


VGA Vaccuperm Gas Advanced
Dosing flow
1000 50-1000 g/h
2000 100-2000 g/h
4000 200-4000 g/h
6000 300-6000 g/h
8000 400-8000 g/h
10000 500-10000 g/h
Connection input and output
5 PE hose 8/11 mm
6 PE hose 10/14 mm
7 PVC pipe DN 15 (external diameter 20 mm)
Adjustment
M manual
A automatic, 230-240V / 50-60Hz
B automatic, 110-115V / 50-60Hz
Control
0 without
1 4-20 mA input signal
2 direct control with 1000 Ohm feedback potentiometer

N not applicable

13
Type key VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGA-146
Example: Vacuum regulator VGA-146-D/1/6-S-0RF

Code Example VGA-146 -D /1 /6 -S -0 R F


VGA Vaccuperm Gas Advanced
Installation
D directly on the chlorine gas drum
W wall-mounting
C on a header line
DC directly on the chlorine gas drum or on a header line
Connection
1 G1
2 G 3/4
3 yoke USA
4 copper pipe 6/8 mm
Output
6 PE 10/14 mm
7 PVC pipe DN 15 (external diameter 20 mm)
Inlet valve
S short
L long, 230-240 V / 50-60 Hz, with liquid trap and heater
M long, 110-115 V / 50-60 Hz, with liquid trap and heater
Pressure indication
0 without
1 with pressure gauge
Connection pressure gauge
T top
R right-hand side
F front
Pressure input
F front
L left-hand side

14
Product selection VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGB-103
Max. dosing quantity Connection, Pressure
Inlet valve Filter Type key Product Number
[g/h] pressure side indication

manometer
yoke USA

external

internal
without
100 250 500 1000 2000

simple

short
G 3/4
G1
100 250 500 1000 2000 1 2 3 B S 0 1 O U Vaccuperm
z z z z z VBG-103-100/1-B-0-O 95712114 (103-100-10298)
z z z z z VBG-103-100/1-S-0-O 95712115 (103-100-10299)
z z z z z VBG-103-100/1-S-0-U 95712116 (103-100-10300)
z z z z z VBG-103-100/1-S-1-O 95712117 (103-100-10301)
z z z z z VBG-103-100/1-S-1-U 95712118 (103-100-10302)
z z z z z VBG-103-100/2-B-0-O 95712119 (103-100-10303)
z z z z z VBG-103-100/2-S-0-U 95712121 (103-100-10304)
z z z z z VBG-103-100/2-S-1-U 95712122 (103-100-10305)
z z z z z VBG-103-100/3-B-0-O 95712123 (103-100-10306)
z z z z z VBG-103-100/3-S-0-U 95712124 (103-100-10307)
z z z z z VBG-103-100/3-S-1-U 95712125 (103-100-10308)
z z z z z VBG-103-250/1-B-0-O 95712126 (103-100-10309)
z z z z z VBG-103-250/1-S-0-O 95712127 (103-100-10310)
z z z z z VBG-103-250/1-S-0-U 95712128 (103-100-10311)
z z z z z VBG-103-250/1-S-1-O 95712129 (103-100-10312)
z z z z z VBG-103-250/1-S-1-U 95712130 (103-100-10313)
z z z z z VBG-103-250/2-B-0-O 95712131 (103-100-10314)
z z z z z VBG-103-250/2-S-0-U 95712133 (103-100-10316)
z z z z z VBG-103-250/2-S-1-U 95712132 (103-100-10315)
z z z z z VBG-103-250/3-B-0-O 95712136 (103-100-10317)
z z z z z VBG-103-250/3-S-0-U 95712137 (103-100-10318)
z z z z z VBG-103-250/3-S-1-U 95712138 (103-100-10319)
z z z z z VBG-103-500/1-B-0-O 95712139 (103-100-10320)
z z z z z VBG-103-500/1-S-0-O 95712140 (103-100-10321)
z z z z z VBG-103-500/1-S-0-U 95712149 (103-100-10322)
z z z z z VBG-103-500/1-S-1-O 95712151 (103-100-10323)
z z z z z VBG-103-500/1-S-1-U 95712152 (103-100-10324)
z z z z z VBG-103-500/2-B-0-O 95712153 (103-100-10325)
z z z z z VBG-103-500/2-S-0-U 95712157 (103-100-10326)
z z z z z VBG-103-500/2-S-1-U 95712158 (103-100-10327)
z z z z z VBG-103-500/3-B-0-O 95712159 (103-100-10328)
z z z z z VBG-103-500/3-S-0-U 95712160 (103-100-10329)
z z z z z VBG-103-500/3-S-1-U 95712161 (103-100-10330)
z z z z z VBG-103-1000/1-B-0-O 95712162 (103-100-10331)
z z z z z VBG-103-1000/1-S-0-O 95712163 (103-100-10332)
z z z z z VBG-103-1000/1-S-0-U 95712164 (103-100-10333)
z z z z z VBG-103-1000/1-S-1-O 95712165 (103-100-10334)
z z z z z VBG-103-1000/1-S-1-U 95712166 (103-100-10335)
z z z z z VBG-103-1000/2-B-0-O 95712167 (103-100-10336)
z z z z z VBG-103-1000/2-S-0-U 95712168 (103-100-10337)
z z z z z VBG-103-1000/2-S-1-U 95712169 (103-100-10338)
z z z z z VBG-103-1000/3-B-0-O 95712170 (103-100-10339)
z z z z z VBG-103-1000/3-S-0-U 95712171 (103-100-10340)
z z z z z VBG-103-1000/3-S-1-U 95712172 (103-100-10341)
z z z z z VBG-103-2000/1-B-0-O 95712173 (103-100-10342)
z z z z z VBG-103-2000/1-S-0-O 95712174 (103-100-10343)
z z z z z VBG-103-2000/1-S-0-U 95712175 (103-100-10344)
z z z z z VBG-103-2000/1-S-1-O 95712176 (103-100-10345)
z z z z z VBG-103-2000/1-S-1-U 95712177 (103-100-10346)
z z z z z VBG-103-2000/2-B-0-O 95712178 (103-100-10347)
z z z z z VBG-103-2000/2-S-0-U 95712179 (103-100-10348)
z z z z z VBG-103-2000/2-S-1-U 95712180 (103-100-10349)
z z z z z VBG-103-2000/3-B-0-O 95712181 (103-100-10350)
z z z z z VBG-103-2000/3-S-0-U 95712182 (103-100-10351)
z z z z z VBG-103-2000/3-S-1-U 95712183 (103-100-10352)

15
Product selection VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGA-111

indication
Pressure

Limiting
Connection

nozzle
Connection
Installation Inlet valve pressure Filter Type key Product Number
pressure side
gauge
cylinder + header line

copper pipe 6/8 mm

pressure gauge
header line

long 230 V

long 115 V
yoke USA
cylinder

external

internal
without

without

without
simple
short
G 3/4

right

with
wall

G1

top
B W C BC 1 2 3 4 S L M B 0 1 X T R 0 1 O U Vaccuperm
z z z z z z z VGA-111-BC/1-B-0X-0-O 96680069 (111-102-10004)
z z z z z z z VGA-111-BC/2-B-0X-0-O 96680071 (111-102-10006)
z z z z z z z VGA-111-B/3-B-0X-0-O 91834644 (111-102-10000)
z z z z z z z VGA-111-BC/1-S-0R-0-O 96680197 (111-202-10130)
z z z z z z z VGA-111-BC/1-S-0R-1-U 96680200 (111-202-10133)
z z z z z z z VGA-111-BC/1-S-0R-0-U 96680128 (111-202-10058)
z z z z z z z VGA-111-BC/1-S-0X-1-O 96680190 (111-202-10123)
z z z z z z z VGA-111-BC/1-S-1R-0-O 96680135 (111-202-10068)
z z z z z z z VGA-111-BC/1-S-1R-1-U 96680117 (111-202-10046)
z z z z z z z VGA-111-BC/1-S-1R-0-U 96680088 (111-202-10015)
z z z z z z z VGA-111-BC/1-S-1R-1-O 96680159 (111-202-10092)
z z z z z z z VGA-111-BC/2-S-0R-0-O 95712188 (111-202-10373)
z z z z z z z VGA-111-BC/2-S-0R-1-U 95712189 (111-202-10374)
z z z z z z z VGA-111-BC/2-S-0R-0-U 96680208 (111-202-10145)
z z z z z z z VGA-111-BC/2-S-0R-1-O 95713053 (111-202-10389)
z z z z z z z VGA-111-BC/2-S-1R-0-O 95712192 (111-202-10375)
z z z z z z z VGA-111-BC/2-S-1R-1-U 95712193 (111-202-10376)
z z z z z z z VGA-111-BC/2-S-1R-0-U 96680205 (111-202-10142)
z z z z z z z VGA-111-BC/2-S-1R-1-O 95713054 (111-202-10390)
z z z z z z z VGA-111-W/4-S-1R-0-U 96680129 (111-202-10059)
z z z z z z z VGA-111-W/4-S-1R-1-U 95712194 (111-202-10377)
z z z z z z z VGA-111-W/4-L-1T-0-U 95712196 (111-202-10378)
z z z z z z z VGA-111-W/4-L-1T-1-U 95712195 (111-202-10221)
z z z z z z z VGA-111-W/4-L-1R-0-U 96680091 (111-202-10018)
z z z z z z z VGA-111-W/4-L-1R-1-U 95713055 (111-202-10391)
z z z z z z z VGA-111-W/4-M-1R-0-U 95712197 (111-202-10379)
z z z z z z z VGA-111-W/4-M-1R-1-U 95712198 (111-202-10380)
z z z z z z z VGA-111-W/4-M-1T-0-U 95713056 (111-202-10392)
z z z z z z z VGA-111-W/4-M-1T-1-U 95713057 (111-202-10393)
z z z z z z z VGA-111-C/1-L-1T-0-O 95712202 (111-202-10310)
z z z z z z z VGA-111-C/1-L-1T-1-U 95712203 (111-202-10381)
z z z z z z z VGA-111-C/1-L-1T-0-U 96680132 (111-202-10064)
z z z z z z z VGA-111-C/1-L-1T-1-O 95713058 (111-202-10394)
z z z z z z z VGA-111-C/1-M-1T-0-O 95712204 (111-202-10382)
z z z z z z z VGA-111-C/1-M-1T-1-U 95712205 (111-202-10383)
z z z z z z z VGA-111-C/1-M-1T-0-U 96680163 (111-202-10096)
z z z z z z z VGA-111-C/1-M-1T-1-O 95713059 (111-202-10395)
z z z z z z z VGA-111-C/2-L-1T-0-O 95712207 (111-202-10384)
z z z z z z z VGA-111-C/2-L-1T-1-U 95712208 (111-202-10385)
z z z z z z z VGA-111-C/2-L-1T-0-U 95712206 (111-202-10254)
z z z z z z z VGA-111-C/2-L-1T-1-O 95713063 (111-202-10396)
z z z z z z z VGA-111-C/2-M-1T-0-O 95712210 (111-202-10386)
z z z z z z z VGA-111-C/2-M-1T-1-U 95712211 (111-202-10387)
z z z z z z z VGA-111-C/2-M-1T-0-U 95713064 (111-202-10397)
z z z z z z z VGA-111-C/2-M-1T-1-O 95713065 (111-202-10398)

16
Product selection VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGA-113
Dosing quantity (g/h) Adjustment Control Type key Product Number

auto. 230 V

auto. 115 V

4-20 mA
without
manual
25 40 100 250 500 1000 2000 3000 4000

direct
25 40 100 250 500 1000 2000 3000 4000 A B M 0 1 2 Vaccuperm
z z z VGA-113-25/M0 95722277 (113-311-10000)
z z z VGA-113-25/A1 95722286 (113-391-10000)
z z z VGA-113-25/B1 95722287 (113-391-10001)
z z z VGA-113-25/A2 95722304 (113-396-10000)
z z z VGA-113-25/B2 95722305 (113-396-10001)
z z z VGA-113-40/M0 95722278 (113-311-10001)
z z z VGA-113-40/A1 95722288 (113-391-10002)
z z z VGA-113-40/B1 95722289 (113-391-10003)
z z z VGA-113-40/A2 95722306 (113-396-10002)
z z z VGA-113-40/B2 95722307 (113-396-10003)
z z z VGA-113-100/M0 95722279 (113-311-10002)
z z z VGA-113-100/A1 95722290 (113-391-10004)
z z z VGA-113-100/B1 95722291 (113-391-10005)
z z z VGA-113-100/A2 95722308 (113-396-10004)
z z z VGA-113-100/B2 95722309 (113-396-10005)
z z z VGA-113-250/M0 95722280 (113-311-10003)
z z z VGA-113-250/A1 95722292 (113-391-10006)
z z z VGA-113-250/B1 95722293 (113-391-10007)
z z z VGA-113-250/A2 95722310 (113-396-10006)
z z z VGA-113-250/B2 95722311 (113-396-10007)
z z z VGA-113-500/M0 95722281 (113-311-10004)
z z z VGA-113-500/A1 95722294 (113-391-10008)
z z z VGA-113-500/B1 95722295 (113-391-10009)
z z z VGA-113-500/A2 95722312 (113-396-10008)
z z z VGA-113-500/B2 95722313 (113-396-10009)
z z z VGA-113-1000/M0 95722282 (113-311-10005)
z z z VGA-113-1000/A1 95722296 (113-391-10010)
z z z VGA-113-1000/B1 95722297 (113-391-10011)
z z z VGA-113-1000/A2 95722314 (113-396-10010)
z z z VGA-113-1000/B2 95722315 (113-396-10011)
z z z VGA-113-2000/M0 95722283 (113-311-10006)
z z z VGA-113-2000/A1 95722298 (113-391-10012)
z z z VGA-113-2000/B1 95722299 (133-391-10013)
z z z VGA-113-2000/A2 95722316 (113-396-10012)
z z z VGA-113-2000/B2 95722317 (113-396-10013)
z z z VGA-113-3000/M0 95722284 (113-311-10007)
z z z VGA-113-3000/A1 95722300 (113-391-10014)
z z z VGA-113-3000/B1 95722301 (113-391-10015)
z z z VGA-113-3000/A2 95722318 (113-396-10014)
z z z VGA-113-3000/B2 95722319 (113-396-10015)
z z z VGA-113-4000/M0 95722285 (113-311-10008)
z z z VGA-113-4000/A1 95722302 (113-391-10016)
z z z VGA-113-4000/B1 95722303 (113-391-10017)
z z z VGA-113-4000/A2 95722320 (113-396-10016)
z z z VGA-113-4000/B2 95722321 (113-396-10017)

17
Product selection VACCUPERM
Chlorine gas dosing systems

Vaccuperm VGA-117
Dosing quantity Connection Adjustment Control Type key Product Number

auto. 230 V

auto. 115 V
PVC DN15
PE 10/14

4-20 mA
without
PE 8/11

manual
1000 2000 4000 6000 8000 10000

direct
1000 2000 4000 6000 8000 10000 5 6 7 A B M 0 1 2 Vaccuperm
z z z z VGA-117-1000/5-M0 95712895 (117-110-10051)
z z z z VGA-117-1000/5-A1 95712896 (117-190-10050)
z z z z VGA-117-1000/5-B1 95712897 (117-190-10051)
z z z z VGA-117-1000/5-A2 95712898 (117-195-10021)
z z z z VGA-117-1000/5-B2 95712899 (117-195-10022)
z z z z VGA-117-1000/6-M0 91834655 (117-110-10008)
z z z z VGA-117-1000/6-A1 96680468 (117-190-10009)
z z z z VGA-117-1000/6-B1 91834657 (117-190-10001)
z z z z VGA-117-1000/6-A2 96680492 (117-195-10003)
z z z z VGA-117-1000/6-B2 96680499 (117-195-10010)
z z z z VGA-117-2000/5-M0 95712900 (117-110-10052)
z z z z VGA-117-2000/5-A1 95712901 (117-190-10052)
z z z z VGA-117-2000/5-B1 95712902 (117-190-10053)
z z z z VGA-117-2000/5-A2 95712903 (117-195-10023)
z z z z VGA-117-2000/5-B2 95712904 (117-195-10024)
z z z z VGA-117-2000/6-M0 91834654 (117-110-10004)
z z z z VGA-117-2000/6-A1 96680469 (117-190-10010)
z z z z VGA-117-2000/6-B1 91834656 (117-190-10000)
z z z z VGA-117-2000/6-A2 96680493 (117-195-10004)
z z z z VGA-117-2000/6-B2 96680500 (117-195-10011)
z z z z VGA-117-4000/5-M0 95712905 (117-110-10053)
z z z z VGA-117-4000/5-A1 96680478 (117-190-10019)
z z z z VGA-117-4000/5-B1 95712906 (117-190-10054)
z z z z VGA-117-4000/5-A2 95712907 (117-195-10025)
z z z z VGA-117-4000/5-B2 95712908 (117-195-10026)
z z z z VGA-117-4000/6-M0 91834651 (117-110-10001)
z z z z VGA-117-4000/6-A1 96680470 (117-190-10011)
z z z z VGA-117-4000/6-B1 96680472 (117-190-10013)
z z z z VGA-117-4000/6-A2 96680494 (117-195-10005)
z z z z VGA-117-4000/6-B2 96680501 (117-195-10012)
z z z z VGA-117-4000/7-M0 96680446 (117-110-10018)
z z z z VGA-117-4000/7-A1 96680482 (117-190-10025)
z z z z VGA-117-4000/7-B1 95712909 (117-190-10055)
z z z z VGA-117-4000/7-A2 95712910 (117-195-10027)
z z z z VGA-117-4000/7-B2 95712911 (117-195-10028)
z z z z VGA-117-6000/6-M0 96680442 (117-110-10006)
z z z z VGA-117-6000/6-A1 96680471 (117-190-10012)
z z z z VGA-117-6000/6-B1 96680473 (117-190-10014)
z z z z VGA-117-6000/6-A2 96680495 (117-195-10006)
z z z z VGA-117-6000/6-B2 91834659 (117-195-10013)
z z z z VGA-117-6000/7-M0 96680447 (117-110-10019)
z z z z VGA-117-6000/7-A1 96680463 (117-190-10003)
z z z z VGA-117-6000/7-B1 95712912 (117-190-10056)
z z z z VGA-117-6000/7-A2 95712913 (117-195-10029)
z z z z VGA-117-6000/7-B2 95712914 (117-195-10030)
z z z z VGA-117-8000/6-M0 95703355 (117-110-10039)
z z z z VGA-117-8000/6-A1 96680464 (117-190-10004)
z z z z VGA-117-8000/6-B1 96680474 (117-190-10015)
z z z z VGA-117-8000/6-A2 96680496 (117-195-10007)
z z z z VGA-117-8000/6-B2 96680502 (117-195-10014)
z z z z VGA-117-8000/7-M0 95712915 (117-110-10054)
z z z z VGA-117-8000/7-A1 95712916 (117-190-10057)
z z z z VGA-117-8000/7-B1 95712917 (117-190-10058)
z z z z VGA-117-8000/7-A2 95712918 (117-195-10031)
z z z z VGA-117-8000/7-B2 95712919 (117-195-10032)
z z z z VGA-117-10000/6-M0 96680440 (117-110-10000)
z z z z VGA-117-10000/6-A1 96680465 (117-190-10005)
z z z z VGA-117-10000/6-B1 96680466 (117-190-10006)
z z z z VGA-117-10000/6-A2 96680497 (117-195-10008)
z z z z VGA-117-10000/6-B2 96680503 (117-195-10015)

18
Product selection VACCUPERM
Chlorine gas dosing systems

Dosing quantity Connection Adjustment Control Type key Product Number

auto. 230 V

auto. 115 V
PVC DN15
PE 10/14

4-20 mA
without
PE 8/11

manual
1000 2000 4000 6000 8000 10000

direct
1000 2000 4000 6000 8000 10000 5 6 7 A B M 0 1 2 Vaccuperm
z z z z VGA-117-10000/7-M0 96680453 (117-110-10025)
z z z z VGA-117-10000/7-A1 96680462 (117-190-10002)
z z z z VGA-117-10000/7-B1 95712920 (117-190-10059)
z z z z VGA-117-10000/7-A2 96680504 (117-195-10016)
z z z z VGA-117-10000/7-B2 95712921 (117-195-10033)

Vaccuperm VGA-146

Connection
indication
Pressure

Pressure
pressure
gauge

input
Connection
Installation Output Inlet valve Type Key Product Number
pressure side
drum or header line

pressure gauge
copper pipe 6/8

PVC pipe DN15


header line

long 230 V

long 115 V
yoke USA

PE 10/14

without
short
drum

G 3/4

front

front
right
wall

G1

top

D W C DC 1 2 3 4 6 7 S L M 0 1 T R F F left
L Vaccuperm
z z z z z z z VGA-146-DC/1/6-L-0TL 96709585 (146-010-10057)
z z z z z z z VGA-146-DC/1/6-L-1TL 96681247 (146-010-10001)
z z z z z z z VGA-146-DC/1/6-M-0TL 96709595 (146-010-10072)
z z z z z z z VGA-146-DC/1/6-M-1TL 96709597 (146-010-10074)
z z z z z z z VGA-146-DC/2/6-L-0TL 96709617 (146-010-10096)
z z z z z z z VGA-146-DC/2/6-L-1TL 96709566 (146-010-10030)
z z z z z z z VGA-146-DC/2/6-M-0TL 95712923 (146-010-10364)
z z z z z z z VGA-146-DC/2/6-M-1TL 95712924 (146-010-10365)
z z z z z z z VGA-146-D/3/6-L-0TL 95702230 (146-010-10193)
z z z z z z z VGA-146-D/3/6-L-1TL 96681252 (146-010-10011)
z z z z z z z VGA-146-D/3/6-M-0TL 95712926 (146-010-10366)
z z z z z z z VGA-146-D/3/6-M-1TL 91834760 (146-010-10019)
z z z z z z z VGA-146-W/4/6-S-0FL 96709580 (146-010-10048)
z z z z z z z VGA-146-W/4/6-S-1FL 96646927 (146-010-10005)
z z z z z z z VGA-146-W/4/6-L-0FL 96681262 (146-010-10094)
z z z z z z z VGA-146-W/4/6-L-1FL 96681254 (146-010-10027)
z z z z z z z VGA-146-W/4/6-M-0FL 95712927 (146-010-10367)
z z z z z z z VGA-146-W/4/6-M-1FL 95701452 (146-010-10268)
z z z z z z z VGA-146-W/4/7-S-0FL 95712928 (146-010-10368)
z z z z z z z VGA-146-W/4/7-S-1FL 96709558 (146-010-10016)
z z z z z z z VGA-146-W/4/7-L-0FL 95712929 (146-010-10107)
z z z z z z z VGA-146-W/4/7-L-1FL 95713205 (146-010-10343)
z z z z z z z VGA-146-W/4/7-M-0FL 95712930 (146-010-10369)
z z z z z z z VGA-146-W/4/7-M-1FL 95712931 (146-010-10370)
z z z z z z z VGA-146-C/1/6-S-0RF 96709583 (146-010-10055)
z z z z z z z VGA-146-C/1/6-S-1RF 96681248 (146-010-10003)
z z z z z z z VGA-146-C/1/7-S-0RF 96681251 (146-010-10008)
z z z z z z z VGA-146-C/1/7-S-1RF 96709644 (146-010-10190)
z z z z z z z VGA-146-C/1/7-L-0TL 95712932 (146-010-10371)
z z z z z z z VGA-146-C/1/7-L-1TL 95712933 (146-010-10372)
z z z z z z z VGA-146-C/1/7-M-0TL 95712934 (146-010-10373)
z z z z z z z VGA-146-C/1/7-M-1TL 95712935 (146-010-10374)
z z z z z z z VGA-146-C/2/6-S-0RF 96709626 (146-010-10105)
z z z z z z z VGA-146-C/2/6-S-1RF 96709567 (146-010-10031)
z z z z z z z VGA-146-C/2/7-S-0RF 96709640 (146-010-10185)
z z z z z z z VGA-146-C/2/7-S-1RF 96709642 (146-010-10187)
z z z z z z z VGA-146-C/2/7-L-0TL 95712938 (146-010-10377)
z z z z z z z VGA-146-C/2/7-L-1TL 96709614 (146-010-10092)
z z z z z z z VGA-146-C/2/7-M-0TL 95712939 (146-010-10378)
z z z z z z z VGA-146-C/2/7-M-1TL 95712940 (146-010-10379)

19
Technical data VACCUPERM
Chlorine gas dosing systems

Compact dosing unit Vaccuperm VGB-103


Medium Chlorine gas
Capacity ranges 5-100 g/h, 10-250 g/h, 50-1000 g/h, 100-2000 g/h
Adjustment ratio 1:20
Accuracy ±4%
Measuring device According to the floater principle, measuring tube 70 mm
Empty indication Automatical visible signal for lack of chlorine
Enclosure: PVC
Inlet valve: Silver/PTFE, special alloy
Springs: Coated with nickel-chrome alloy
Materials Diaphragm: FEP
Rate valve: PVC
O rings: FKM
Yoke: Cast iron, nickel plated
Pressure side chlorine: G 3/4; G 1, yoke
Connections
Vacuum safety line: PE hose 8/11 mm
Weight 1.3 up to 2 kg
• Manometer 0 to 16 bars, NG 63
Options • Internal filter inside the vacuum regulator
• External filter outside the vacuum regulator, on the connection of the gas cylinder or drum

Dimensions VGB-103

257

132
146
82
63
92

VGB-103
TM04 1262 1009

71
197
31 14 40

Fig. 14 Vaccuperm VGB-103

Vaccuperm VGB-103 is directly mounted on a chlorine


cylinder.

Accessories
For injectors, chlorine gas absorption cylinder and
other accessories please see the Vaccuperm Accesso-
ries Data Booklet.

Maintenance kit for Vaccuperm VGB-103

Comprising Order No.


Valve seats, filter, pressure spring, flat 91836513
gaskets, lock washers, O-rings (553-1704)

20
Technical data VACCUPERM
Chlorine gas dosing systems

Vacuum regulator Vaccuperm VGA-111


• For operation with dosing regulator VGA-113 or
VGA-117.
• With inlet valve and safety overpressure valve.
• With gaskets for cylinder connection.
• Long inlet valve with liquid trap (230 V with
Euro plug, 115 V with USA plug).

Technical data VGA-111


Medium Chlorine gas
Capacity range Up to 4000 g/h
Empty indication Automatical visible signal for lack of chlorine
Enclosure: PVC
Inlet valve: Silver/PTFE, special alloy
Springs: Coated with nickel-chrome alloy
Materials
Diaphragm: FEP
Rate valve: PVC
O rings: FKM
Pressure side chlorine gas: Union nut 1“, 3/4“; copper tube 6/8 mm (1/2“), USA yoke
Connections Vacuum line: PE hose 8/11 mm
Vacuum safety line: PE hose 8/11 mm
Weight 2.3 kg
• Manometer 0 to 16 bars for pressure indication
• Limiting nozzle full vacuum
Options • Internal filter inside the vacuum regulator or
• External filter outside the vacuum regulator, on the connection of the gas cylinder/drum
• Liquid trap with heater with long inlet valve

Dimensions VGA-111

340

146
214
63 82
125

VGA-111
TM04 1261 1009

153

31

Fig. 15 VGA-111 with manometer on the right side and short inlet valve

21
Technical data VACCUPERM
Chlorine gas dosing systems

Dimensions VGA-111

204

ca. 315

236

TM04 1263 1009


Fig. 16 VGA-111 with liquid trap

Accessories
For injector, header line, change-over device, safety
valve, testing agent, and other accessories please see
the Vaccuperm Accessories Data Booklet.

Maintenance kits for VGA-111

Comprising Order No.


Kit for VGA-111 without liquid trap:
91835972
Valve seat and cartridge, filter, pressure spring,
(553-594)
flat gasket, lock washer, O-rings
Kit for VGA-111 with liquid trap:
91835977
Valve seat, filter, pressure spring, flat gasket,
(553-605)
lock washer, O-rings

Repair kit for VGA-111

Comprising Order No.


Diaphragm, valve seat, valve cartridge, valve
96688860
cone, filter, pressure spring, flat gasket, O-rings,
(553-1516)
screws, union nuts

22
Technical data VACCUPERM
Chlorine gas dosing systems

Dosing regulator Vaccuperm VGA-113


• For operation with vacuum regulator VGA-111. VGA-113 for automatic operation
• With compensation regulator and measuring device. • Synchronous motor with limit switches,
• Fastening for wall mounting included. IP55 enclosure.
• Actuating time (1-100 %):
Technical data VGA-113 108 s at 50 Hz, 87 s at 60 Hz.
• Power consumption: 3 VA.
Medium Chlorine gas
Capacity range Up to 4000 g/h • Mains voltage of servomotor 230 V (50/60 Hz) or
Adjustment ratio 1:20 115 V (60 Hz).
Accuracy ±4%

Measuring device
According to the floater principle, measuring Servomotor with 4-20 mA input
tube 70 mm • For proportional control (direct connection to water
Enclosure: PVC meter).
Inlet valve: Silver/PTFE, special alloy
Springs: Coated with nickel-chrome • Manual/automatic switch.
Materials alloy
Diaphragm: FEP • Trimmer for zero point/limit value.
Rate valve: PVC
O rings: FKM
• Keys for manual control open/close.
Connections Vacuum line: PE hose 8/11 mm
Weight 0.9 kg; 3.1 kg (with servomotor) Servomotor with feedback potentiometer
• Automatic control with servomotor (4-20 mA • Connection to external controller.
Options
or direct control) • Single potentiometer 1000 Ohm.
VGA-113 for manual operation Dimensions VGA-113
Dimensions VGA-113
ca. 190

50

178
95

46.5
TM04 1521 1310
90

ca. 410

ca. 236 120


50
95

46.5
Fig. 17 Dosing regulator VGA-113 for manual opera-
tion
TM04 1522 1310

ca. 260 120

Fig. 18 Dosing regulator VGA-113 with electric ser-


vomotor

Accessories
For injector, header line, change-over device, safety
valve, testing agent, and other accessories please see
the Vaccuperm Accessories Data Booklet.

Maintenance kit for VGA-113

Comprising Order No.


91835974
Valve seat, flat gasket, lock washer, O-rings
(553-602)

Repair kit for VGA-113

Comprising Order No.


Diaphragm, pressure spring, flat gasket, 96688861
stopper, O-rings, screws, union nuts (553-1517)

23
Technical data VACCUPERM
Chlorine gas dosing systems

Vacuum regulator Vaccuperm VGA-146


• For operation with dosing regulator VGA-117.
• With inlet valve and safety overpressure valve.
• Overpressure connection for PE hose 8/11 mm. 193

• Always with liquid trap, if with long inlet valve. 140

• 230 V with Euro plug; 115 V with USA plug (for


liquid trap.
• Filter inside the vacuum regulator.
• Length of connection: short.

Technical Data VGA-146


Medium Chlorine gas

TM04 1279 1009


Capacity range Up to 10 kg/h
Enclosure: PVC
Inlet valve: Silver/PTFE, special alloy
Springs: Coated with nickel-chrome alloy
Materials
Diaphragm: FEP
Rate valve: PVC
O rings: FKM Fig. 20 Vacuum regulator VGA-146 (mounting on
Pressure side Union nut 1“; 3/4“; yoke USA; header lines)
chlorine gas: copper pipe 6/8 mm (1/2“)
Connections
Vacuum safety PE hose 10/14 mm or PVC pipe
line: DN 15 (external diameter 20
mm)
Weight 2 kg; 4 kg (with liquid trap)

Dimensions VGA-146

Ø9
160

200
86

173

TM04 1257 1009

Fig. 19 Vacuum regulator VGA-146 (wall mounting)

24
Technical data VACCUPERM
Chlorine gas dosing systems

Dimensions VGA-146

177

143 131 ~ 198

Ø 172

PE 10/14

11
8/
PE
236

TM04 1278 1009


Fig. 21 Vacuum regulator VGA-146 (with liquid trap and yoke connection)
75

177
PE 10/14

TM04 1260 1009

59

Fig. 22 Vacuum regulator VGA-146 (with liquid trap


and union nut connection)

Accessories

For injector, header line, change-over device, safety


valve, testing agent, and other accessories please see
the Vaccuperm Accessories Data Booklet.

Spare parts sets for VGA-146

Comprising Order No.


Kit for VGA-146 without liquid trap:
91836513
Diaphragm, valve seat, valve cartridge, filter,
(553-1074)
pressure springs, flat gasket, O-rings
Kit or VGA-146 with liquid trap:
91835842
Diaphragm, valve seat, valve cartridge, filter,
(553-1075)
pressure springs, flat gaskets, O-rings

25
Technical data VACCUPERM
Chlorine gas dosing systems

Dosing regulator Vaccuperm VGA-117


Technical data VGA-117 Servomotor with 4-20 mA input
• For proportional control (direct connection to water
Medium Chlorine gas
meter).
Capacity range Up to 10 kg/h
Adjustment ratio 1:20 • Manual/automatic switch.
Accuracy ±4% • Trimmer for zero point/limit value.
According to the floater principle, measuring • Keys for manual control open/close.
Measuring device
tube 190 mm
Enclosure: PVC
Inlet valve: Silver/PTFE, special alloy Servomotor with feedback potentiometer
Springs: Coated with nickel-chrome • Connection to external controller.
Materials alloy
Diaphragm: FEP • Single potentiometer 1000 Ohm.
Rate valve: PVC
O rings: FKM • Automatic control on request.
Weight 2.6 kg; 3.1 kg (with servomotor)
Dimensions
VGA-117 for manual operation
• Operation with vacuum regulator VGA-146.
Ø6
• Mounted on a plate for wall mounting.
• With manual rate valve and measuring device.
• Vacuum connection for PE hose (8/11 mm or 10/
14 mm) or PVC pipe (DN 15, external diameter
20 mm).
• Without differential pressure regulator.

575
600
Dimensions VGA-117

Ø6

TM04 1267 1009


145
170

Fig. 24 Dosing unit VGA-117 with servomotor


400
375

Accessories

For injector, header line, change-over device, safety


valve, testing agent, and other accessories please see
the Vaccuperm Accessories Data Booklet.
TM04 1265 1009

Spare parts sets for VGA-117


105
130 Description Order No.
Valve seat, lock washer, compensating disc, 91835976
O-rings (553-604)
Fig. 23 Dosing unit VGA-117 for manual operation Valve seat, lock washer, screwings, hose 96689067
connection, hoses, O-rings, grease (553-617)
VGA-117 for automatic operation
• Synchronous motor with limit switches, IP55
enclosure.
• Actuating time (1-100 %): 108 s at 50 Hz, 87 s at
60 Hz.
• Power consumption: 3 VA.
• Mains voltage of servomotor 230 V (50/60 Hz) or
115 V (60 Hz).
• Without differential pressure regulator.

26
Further product documentation Vaccuperm VGA and VGB

WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185 000 Grundfos products in more than 20 languages.
In WebCAPS, all information is divided into 6 sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.

Catalogue

With a starting point in areas of applications and pump types, this


section contains
• technical data
• curves (QH, Eta, P1, P2, etc) which can be adapted to the den-
sity and viscosity of the pumped liquid and show the number of
pumps in operation
• product photos
• dimensional drawings
• wiring diagrams
• quotation texts, etc.

Literature

In this section you can access all the lastest documents of a given
pump, such as
• data booklets
• Installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures, etc.

Service

This section contains an easy-to-use interactive service catalogue.


Here you can find and identify service parts of both existing and
cancelled Grundfos pumps.
Furthermore, this section contains service videos showing you how
to replace service parts.

27
Further product documentation Vaccuperm VGA and VGB

Sizing 0 1

With a starting point in different application areas and installation


examples, this section gives easy step-by-step instructions in how
to
• select the most suitable and efficient pump for your installation
• carry out advanced calculations based on energy consumption,
payback periods, load profiles, lifecycle costs, etc.
• analyse your selected pump via the built-in lifecycle cost tool
• determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to select and compare replacement


data of an installed pump in order to replace the pump with a more
efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grundfos


pumps with the one you have installed on your site. After having
specified the installed pump, the guide suggests a number of
Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section it is possible to download 2-dimensional (2D) and


3-dimensional (3D) CAD drawings of most Grundfos pumps.

The following formats are available in WebCAPS:

2-dimensional drawings
• .dxf, wireframe drawings
• .dwg, wireframe drawings.

3-dimensional drawings
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed inform-
tion on more than 185,000 Grundfos products in more
than 22 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet
connection is available.
WinCAPS is available on CD-ROM and updated once a
year.
Fig. 25 WinCAPS CD-ROM

Subject to alterations.

28
29
30
31
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

95718867 0410
15.781004 V3.0
GB
The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks
owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

Grundfos Management A/S Grundfos Alldos Dosing & Disinfection


Poul Due Jensens Vej 7 Alldos Eichler GmbH
DK-8850 Bjerringbro Reetzstrasse 85
D-76327 Pfinztal (Söllingen)
Telephone: +45 87 50 14 00
Telephone: +49 72 40 61 0
www.grundfosalldos.com

You might also like