Download as pdf
Download as pdf
You are on page 1of 9
amu roenan EAA PeBANGUUN STEM FENTEDAMN AR AR BERD FENGGA TURE svn. 98, LoWBOXTENGAA FORMULIR PERSETUJUAN MATERIAL row 1 ‘we To = etm TT PE paaxon (a RSTRNT am PAaor dela Mancha’ intwmart Aslan daw pecan ventions Pembntas Sapaya — Mngfunetwn Peelen YC Standarel Soyerhi Cont C ABE /SBmWEDER At Chea ) [ERT FERGELUA Ton EO ~ Mentertafan Wee ing Kresrem ucdk — tanel Pet Ae ot PAN ROG CHNT CHINT ELECTRIG BRIEF CATALOG PERALATAN LISTRIK TEGANGAN RENDAH LOW VOLTAGE ELECTRICAL APARATUS Ey (ie 60898) Cy ec 60947. MINIATURE CIRCUIT BREAKER NXB-63 SERIES @ + Rated Current 11,2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63 A + Breaking Capacity: NXB-63- 6 kA, NXB-63H - 10 kA + Available Poles 14,2, 3,4P + Acc. available : Shunt Release, UVT, Aux Contact, Aux Alarm Contact eee lor 3 we MOULDED CASE CIRCUIT BREAKER M1 SERIES - FIXED TYPE up to 250A NXM SERIES - FIXED TYPE 80 up to 800A NMB SERIES - ADJUSTABLE TYPE \e—— + Rated Current + Breaking Capacity + Available Poles + Acc. available 110-1250 : Up to 100 kA :2,3,4P : Motor, Rotary Handle, Shunt Release, UVT, Aux Contact, Aux Alarm Contact ogas ‘atate teal) TTA TYPE-TEST PANEL NGC8 SERIES + Full range of cabinet type + Up to Form 48 Separation + Rated Current (le) up to 63008 + Rated peak withstand current (Ipk) 230 kA + Rated short circuit withstand current (Icu) 100 KA / 1s MOULDED CASE CIRCUIT BREAKER NXB-125 SERIES + Rated Current £80, 100, 125.4 + Breaking Capacity: 10 kA + Available Poles 1,3,4P + Acc. available + Shunt Release, UVT, ‘Aux Contact, ‘Aux Alarm Contact 2 aes Ey (tec 60947-2) AIR CIRCUIT BREAKER NXA SERIES, NA1 SERIES, NA8 SERIES + Rated Current + Breaking Capacity + Available Poles + Type + Op. Mechanism £800 ~ 6300 A Up to 120 kA 3,4P Fixed & Drawable : Manual (Free UVT & Aux) Motor (Free UVT, Aux, Closing) A Current) Type Intelligent Controler Long Time & Short Time Delay, Instantaneous Tip, Ground Fault (LSIG Protection) Rad (EC 61439.) ise Full protection functions (overioad + short circuit curent + earth WARNING! LINE OR INCOMING MUST BE FROM TOP/ABOVE RESIDUAL CURRENT CIRCUIT BREAKER WITH OVER VOLTAGE PROTECTION NXBLE SERIES (ec 616431) + Rated Current 26-63A ! + Breaking Capacity: 6 kA é + Available Poles HIP+N, 3P+N Bi) ‘a o6 + Sensitivity 10 & 300 mA r a NU6 - II SERIES + Imax up to 100 kA + Available Poles : 2, 4P + Draw Out Type + Protect Electric System from Lightning and instantaneous f.fis!* Over-Voltage Bers be (61095), NCHS SERIES + Rated Current + Available Poles ,2,4P + Main Contact NO+INC, 2NO+2NC, 4N0, ANC + Coll Voltage £110, 220, 400 vac Para STE tc 60947-1) NXZ SERIES (PC TYPE), NXZB-63 & NZ7 SERIES (CB TYPE) fee ae + Rated Current 163-630 } ae + Available Poles 24P ee seen + Features Hi + Switch PLN - Generator + Signal ON-OFF Generator + Integrated Controller + Over voltage and Under Voltage + Phase Failure + Transfer Delay 0s - 180s NXMLE SERIES ec 60269. + Rated Current + Breaking Capacity + Available Poles + Sensitivity }00, 200, 300 mA (adjustable) Ea) dec 60269.2) RT28-32 SERIES .e + Rated Current -32A + Breaking Capacity: 50 kA + Available Poles. =: 1P iad + Made of ceramics material . DOU teas CZ1-63 + Rated Current + Available Poles 2-634 . and 4P 6 = ‘= Manual switching PLN-Generator + ONLY 1 Source can be operated, + Equipped with Indicator, Overload and Short-Circuit Protection. Et fee CHANGE OVER SWITCH LOAD BREAK SWITCH NH4O SERIES ec 6o9a7. + Rated Current + Available Poles + Optional Extended Rotary Handle + Equipped with ARC-CHAMBER t Decca) ioe EC 60947-1, 60987-4-1, 0947-5-1) XC, NC-1 & NC-2 SERIES + Rated Current : 6 ~ 800 A (800A only for NC2) + Available Poles : 3 and 4 P (4P only for NC1 & NC2) + Build-in Aux Contact for NXC + NXC<=100A TOOL FREE installation + Available Accessories : Front Mounting Aux, Side Mounting Aux, Time Delay Contact Block. mene ae mori BUT ie (tec 6181041) NXJ SERIES Available contact : + 22 (2NO*2NC) - 8 PIN + 32 (3NO+3NC) - 11 PIN r. cal + 42 (ANO+4NC) - 14 PIN : Available Cofl Voltage : + 12, 24, 48, 110, 220 VAC/VDC i “Socket Available Groce ies ae XJ3-S, XJ3-D, NJYB3-15 SERIES (iE 60947-5-1) «+ 3ephase voltage relay with LED indicator + Protection: nes + Phase failure (all-type) + Wrong phase sequence (all-type) i + 3-phase voltage unbalance (all-type) ff + Over-voltage 380 - 460 V, Under-voltage 300 - 380 (XJ3-D & NJYB3 Only) + Built-in microprocessor (NJYB3 Only) + 3-phase 4-wire 220 V circuits with a frequency unbalance (NJYB3 Only) (ae anes (tec 60947-1, 60947-5-1) NXR SERIES ‘+ Rated Current : 0.1 = 6304 + Features + 3-Phase R-S-T Protection + Phase Failure Protection + Stop and Test Button + Release indicator + Temperature compensation + Continuous adjustment of setting current ‘Manual and Automatic Reset button + (NXR-200 and 630, only Manual Reset), + Electrically separated 1NO + 1NC contact, “Mounting Block available for installation Te le fee JZC1 SERIES SEC1-44 + Rated Voltage : 220 VAC + Rated Current : AC-15 (AC-11) 54 ‘+ Main Contact: 4NO + 4NC JEC1-44z. + Rated Voltage : 24 VDC + Rated Current : DC-13 (DC-11) 0.25 A + Main Contact: 4NO + 4NC tale KG10D & KG316 + Rated Voltage : 220 VAC 50 / 60 Hz + Rated Current : AC-15 220 V3. + Time Control Range : 1 min ~ 168 hours + Time of Open / Close : 16 opens & 16 closes + KG100 - build in rechargeable battery + KG316 - replaceable AAA battery CONTACTOR TYPE RELAY (dec 61095) (eer dec 60947.5-1) = weet Wienke at eines asd fee fea Ec 60947-5-1) aecorsse) NJYW1 SERIES JBK5 SERIES eoeee + Can be used to control TWO tanks + Rated Capacity: 63 ~ 2500 VA (Water Supply and Water Drainage) + Multiple Input & Multiple output + Operating Mode: Continuous Working | : + Available type: + Conductor Length: Max 2 Km. + Input 380/220 V - Output 220/110/48 “ot applicable for iiqud with low « Input 380/220 V - conductivity suchas oil & explesve chemical liquid Output 36/24/12 V EC pe aeRO NQ2 SERIES -- ict NS2 SERIES Shae eae } te wae + Rated Current: 0.1 = 25 cen hee 230 - 690 VAC, 50 Hz + Rated Power: 5.5 ~ 15 kW. + Rated current: 0.1 - 804 NON push button available eo 35 ~ 100 kA + Aux Contact Available Soya EE el aL EC 61558) INVERTER NVF2G SERIES (EC 6094741) TND1, TNS1, TNSZ SERIES + 0,75 = 315 kW aear + Constant Torque Type: (0-400) Hz h- + TNDI 1-Phase Voltage Stabilizer + Suggested applicatior i e + Output capacity : 0,5-15 kVA FAN, PUMP, COMPRESSOR, BLOWER. ;. 3 + TNS1 3-Phase Voltage Stabilizer + Output capacity : 2-60 kVA SOFT STARTER NJR2-D SERIES —_(€¢ 60947-41) = 15-500 kW + Soft Starting and Stopping of 3-Phase AC Motor ' ‘+ TNSZ 3-Phase Voltage Stabilizer tit + Output capacity : 50-600 kVA POWER QUALITY Lal CAPACITOR CONTACTOR CAPACITOR — POWER FACTOR CONTROLER NWC6 SERIES ec 06st.) CJ19SERIES veceovs7.4.1) JKF8 SERIES + Rated Voltage : 450-525 V + Size 120 x 120, + Rated Capacity : 5-30 KVAR pill +12 steps + Dry Type, filled with + Coil voltage + Real-time display of dry flame-retardant material up to 400 V 7 the network status + Can be mounted + Rated KVAR 18-80 = (power factor, voltage, vertically & horizontally + Auxilliary Contact = ampere, active power, 1NO + 1NC reactive power) + If THD (u) <3% use 450 V )« Equipped with + Factory pre-program + if THD (u) >3% and <5% use 525 V current limiting block. (full automation) or + if THD (u) >5% use 525 V + reactor ‘manual setup. PROJECT REFERENCE ALFA TOWER, {ASTON JAMBI HOTEL & MALL CITRAGRAND, CILEGON CENTER MALL aan osor cry RESIDENCE, PADDINGTON HEIGHTS, GRAND PARUBUWONO TRACE THESPRINGLAKESUNMARECON, PARKLAND AVENUE APARTMENT asi SERPONG [AKASABSO CITY, 'BETOS LAGOON APARTMENT, MNC TOWER ARARTA AKARTA PEKANBARU BANOUNG >> Contact us for more references PROJECT REFERENCE MENARA ONE, GRAND SUNGKONO LAGOON, CGRAND ASTON CITY HALL, MAYAPADA BAMUA CENTER, RANIARMASIN SERPONG UNIVERSITAS AHMAD DAHLAN, GRAND ASIA AFRIKA RESIDENCE, ° AYOMA, BELMONT RESIDENCE. 'INTARO ICON, (GATEWAY PASTEUR, SERPONG TAKARA >> Contact us for more references CHINT INDONESIA NETWORK ScrNT, own a Ben ¢ ar ae no GHNT — Poe PT. CHINT INDONESIA was founded in 2005. Until recently, PT. CHINT INDONESIA has developed an extensive network ‘across Indonesia. In these 15 years, CHINT has gained trust from Users across many sectors, be it private and government. With vast distribution network, quality products, impeccable services, and abundant inventory, we are confident that we can fulfil your electrical needs, be it for general public uses, industries, buildings, and constructions, and even power generations. CHINT Group is No.1 electrical manufacturer in Aci and No.3 in the world, CHINT is prezent in more then 127 countries around the world. CHINT's products have been certified by renowned international testing centers and laboratories; and have been awarded prestigious certificates such as KEMA, VDE, TUV, UL, SEMKO, Fi, ESC, PCT, SNI, SIRIM, etc. CHINTs manufacturing facility has also passed the certification of ISO 9001, ISO 14001 and OHSAS 18011 one = eet oor oan ope PT. CHINT INDONESIA resmi berdiri pada 2005. Hingga saat inj PT. CHINT INDONESIA telah mengembangkan jaringan pemasaran di seluruh wilayah Indonesia, Dalam kurun waktu 15 tahun, CHINT bethasil mendapatkan kepercayaan dari para pengguna di berbagai sektor, bak swasta maupun ppemerintahan. Dengan jaringan pemasaran yang luas, kualtas pproduk yang prima, pelayanan yang memuaskan, serta inventor yang memada, kami yakin dapat memenuhi seluruh kebutuhan ‘elektrkal pengguna di Indonesia; baik dari kalangan umum, industri, gedung dan bangunan, hingga ke pembangkit listrik. CCHINT Group adalah produsen elektrikal No.1 di Asia dan No.3 terbesardi dunia. CHINT hadidilebih dari 127 negara di seluruh dunia. Produkproduk CHINT telah diuji di berbagai pusat jpengujian dan laboratorum terkemuka di dunia dan meraih sertifikat bergengsi seperti KEMA, VDE, TUV, UL, SEMKO, Fl, ESC, PCT, SNI, SIRIM, dll. Fasiitas produksi CHINT juga telah ‘ulus sertifkasi SO 9001, ISO 14001, dan OHSAS 180011.

You might also like