Error Codes Special Modes: Yes Yes Yes

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° SERVICE DATA SHEET SYSTEM DIAGNOSTIC MODE

CONTROL SETTING Activate: Press FZ ^ and FZ v for up to 10 sec. simultaneously. Press FF ^ to advance
Type A with Run / 65°F (18°C) Ambient 90°F (32°C) Ambient A06686901 through tests.
Start Capacitor Deactivate: Press FF ^ for up to 10 sec. Diagnostic Mode will automatically deactivate after 10
FREEZER ICE MAKER - AUTOMATIC DEFROST min. of inactivity.
Operating Time 90 to 100% 100%
BOTTOM FREEZER - R134a Note: Silence alarm.
-5° to 2°F -1° to 3°F • Tests marked with “*” may not be applicable to this unit and will not be displayed in System DiagnosticMode.
Freezer Temperature
(-20° to -17°C) (-18° to -16°C) • Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
34° to 39°F 34° to 39°F • View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
Refrigerator Temperature
(1° to 4°C) (1° to 4°C)
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION. • Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.

-2 to 6 psig -2 to 6 psig Test To activate test: Passing result


Low Side Pressure
(-14 to 41 kPa) (-14 to 41 kPa) ERROR CODES SPECIAL MODES -- First Screen -- Blank UI display, no LEDs illuminated.
High Side Pressure 85 to 105 psig 120 to 135 psig Display Interpretation Mode Display Activate Deactivate -- Second Screen -- All LED lights on UI illuminated.
(last 1/3 cycle) (586 to 724 kPa) (827 to 931 kPa) FZ FF FZ FF (Press for up to 10 sec. simultaneously) -- Third Screen -- Blank UI display, no LEDs illuminated.
Wattage (last 1/3 cycle) 30 to 50 50 to 70 -- OP Open FF Manual Defrost d F FF ^ and FF v Same to 46 Humidity Sensor Activates “OP” if open, “SH” if short. AC Heater System: Displays
Amps (running) .4 to .8 .7 to .9 Cavity Thermistor deactivate automatically %RH. DC Heater System: “HI” - heater should be on. “Lo”
- heater should be off. %RH is displayed when humidity is
Base Voltage 115 vac (127 vac max) OP -- Open FZ Demo / 77 77 FZ ^ and FF v Unplug to
between “Lo” and “HI” values; heater could be on or off.
Cavity Thermistor Showroom deactivate
DEFROST SPECIFICATIONS -- SH Shorted FZ Sabbath Sb Sb FZ v and FF ^ Same to deactivate
2 Freezer Press power on-off Freezer defrost heater on when “on”; off when “off”. Evapo-
Defrost Heater rator thermistor temperature is flashed. Watch for temp
→ Check at the Cutout
Thermal connector from the power cord
Heater → CheckDefrost
at Inverter Board on Cavity Thermistor
→ Remove inverter box from the → Check connections from Inverter
harness into the inverter board, located in increase with the heater on. It may take a few minutes for
Compressor
Heater compressor and check resistance Board to Compressor
the machine compartment.
SH -- Shorted FZ System Blank UI display, FZ ^ and FZ v Press and hold FF the evaporator to heat up.
Cabinet Size: yes (BLK and RED wires)
Termination across compressor winding pairs as
yes Thermistor yes
(PUR and WHT wires) Diagnostic no LEDsAre connections from Inverter^ to deactivate
shown. 12 Condenser Fan Press power on-off Fan running when “on”; stopped when “off”
Cut-in Cut-out Watts Ohms Is Inverter
Cut-outBoard receiving 10-15 Board to Compressor intact?
illuminated
27’ & 28’ SD, 22’ CD Is Inverter Board receiving 115 VAC VAC and 1-5 VDC from MainSY Is resistance across all winding 43 Mullion Anticon- Press power on-off Flip Mullion Heater on when “on”; off when “off”
CF UI to Main Board Current Air FZ FF Default Settings Automatically
110°F
from 135°F
power supply? 500 26.5 Control48°F
Board? pairs equal? densation Heater
communication Temps Temp Temp and C/F Buttons after 10 seconds
(43.3°C) (57.2°C) (8°C)
no no failure; on startnoup no 38 VCC Compressor Press power on-off Compressor on when “on”; off when “off”
CONDENSER FAN MOTOR SY CE UI to Main Board Notes: 13 FF Lights Press power on-off FF lights on when “on”; off when “off”
Watts RPM Amps communication • Always
Replace Compressor and check for pin back-outs, pinched or damaged wires before 15 Freezer Press power on-off Press to toggle between “off”, “Lo” and “HI”. A current sen-
Identify and repair damaged
Inverter
error; after Board.
a period replacing components.
Check
•1100 CWvoltage
supply. wires or poor connections Evaporator Fan sor reading is flashed (units are not mA). OFF reading should
3.1 0.03 Running of operation • Determine whether failure isbetween
causedInverter
by the component,
Board and main control be around 2. “Lo” speed reading should settle down to
• CheckShaft
Opposite and repair power
cord harness wiring and SY EF Freezer Evaporator board or wiring. Contact TID before
Compressor. replacing main control board. around 9. “HI” speed reading should settle down above 40.
→ Check at Main Control Board
FREEZER ICEconnections.
MAKER SPECIFICATIONS Fan Failure • Refer to Service Manual for additional information. yes
(BLK/WHT and RED/BLK wires) 20 FZ Lights Press power on-off FZ lights on when “on”; off when “off”
no
Electrical 115 vac (127 vac max) Is Main Control Board sending Replace Main Control Board. 22 Damper Press power on-off Perform test 15 and set fan to “HI”. Then, check for air flow
Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C) 10-15 VAC and 1-5 VDC to when open “OP,” and no air leaks when closed “CL”.
Inverter Board? VCC COMPRESSOR MOTOR RESISTANCE CHECK
Replace Inverter Board 23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open
Heater Voltage 115 vac VCC Resistance Check
yes
Check resistance between terminals 1 and 24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open
2, 2 and 3, 3 and 1. 29 FF Thermistor Activates UI shows temperature sensed by FF thermistor; pass if
Identify and repair damaged wires or If all resistances are equal,
automatically within 10°F of temperature measured with gauge at FF
poor connections between Main Control compressor is operative.
Board and Inverter Board. thermistor location.
“OP” if open; “SH” if short
30 FZ Thermistor Activates UI shows temperature sensed by FZ thermistor; pass if
automatically within 10°F of temperature measured with gauge at FZ
thermistor location.
“OP” if open; “SH” if short
33 Ambient Therm- Activates UI shows temperature sensed at main board; pass if within
istor @ Main automatically +20°F/-10°F of temperature measured with gauge at main
Board board location.
“OP” if open; “SH” if short
CAUTION 34 Ambient Therm- Activates UI shows temperature sensed at UI; pass if within +20°F/-
LINE POWER NEUTRAL All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch istor @ UI automatically 10°F of temperature measured with gauge at UI location.
insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the “OP” if open; “SH” if short
ICE MAKER plastic liner.
39 Freezer Activates UI shows temperature sensed by freezer evaporator thermis-
LT. BLUE

BLK BRN Evaporator automatically tor; pass if within 10°F of temperature measured with gauge
ICE MAKER

P-3 Thermistor at evaporator thermistor location. “OP” if open; “SH” if short


THERMAL
CUT-OUT FREEZER ICE MAKER INFORMATION 0- Firmware Press power on-off Displays digit sequence; record
(Where Applicable) Water Fill Parameters
MOTOR Adjustment
RED Test Cycling: Remove cover by inserting screwdriver in notch 1- Main Board Press power on-off Displays digit sequence; record
BLK

HOLD at bottom and prying cover from housing. Use screwdriver to Firmware
Motor
SWITCH rotate motor gear counterclockwise until holding switch circuit
ICE MAKER

NO LT. BLUE Gear


P-4
3- UI Firmware Press power on-off Displays digit sequence; record
RED
THERMOSTAT is completed. All components of ice maker should function to
WATER VALVE

NC TU
C
NO complete the cycle. R Mounting
RED

N
Plate
BLK BLU
NC Water Fill Volume: The water fill adjustment screw will Screws IMPORTANT SAFETY NOTE
C

MOLD HEATER change the fill time. One full turn is equal to 20cc (.68 oz.). The information provided herein is designed to assist qualified repair personnel only. Untrained persons should
SHUTOFF
165 WATTS NO The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing
SWITCH Mounting
GRN / YEL valve is replaced, the fill volume must be checked. Plate this appliance.
NC YELLOW Screw
P-1 C
P-2 Timing
IMPORTANT
MOLD MOUNTING WATER FILL
PLATE SWITCH
Gear If any green grounding wires are removed during servicing, they must be returned to their original position
ICE MAKER and properly secured.
POWER CORD

NON-RIBBED

(NEUTRAL)
LED LIGHT WIRING

RIBBED
(LINE)
BASE PLATE
GROUND

1
4

2
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU

WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU

WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
DC SIDE AC SIDE COMPRESSOR
GROUND
LT. BLU
BLK
POWER

BLK
1
BLK LT. BLU
VARIABLE SPEED
GND CONTROL SIGNAL COMPRESSOR/ INV.
3 PIN 3
WHT
2 COMM.
RED/BLK
LED LED LED USER
J2 2 PIN 4 J9 NEUTRAL 1 LT. BLU BLK/WHT
3
INTERFACE
1 PIN 5
+5V DC 12 VDC
RG-5 RG-4 RG-3 LH1 RED
4 +12V DC
CAB. GROUND J1 2 GRN/YEL GRN/YEL
BASE PLATE

3
BLK GROUND GRN/YEL
1 WHT/BLU WHT/BRN 4
LINE
LED LED GRY/YEL
5

PIN 4
PIN 1
PIN 5
2 WHT/BLU WHT/BRN 3 FREEZER RIGHT DOOR
3 WHT/BRN WHT/BLU 2 FLANGE
4 EVAPORATOR GRY/YEL MC1
6
WHT/BRN 1
RG-2
WHT/BLU
SENSOR +5V DC MC1 FLIP MULLION COVER
RG-6
1 WHT/BLU WHT/BRN
GRY/WHT
7
RL5 J2 3 YEL/RED
PIN 2 RIGHT HINGE
GROUND GRN/YEL
2
4
J6
LED LED FREEZER 2
2
3 WHT/BRN
WHT/BRN
WHT/BLU
3
2 SENSOR 1 GRY/WHT
8 +5V DC
RL4 7 YEL/BLK
PIN 3 LT. BLU
PIN 2 3 MULLION HEATER
4 WHT/BLU 1 MB1
RG-7 RG-1
FRESH FOOD PIN 7
GRY/BLK
11 RL6 J3 2 LT.BLU/BLK
PIN 8
LT.BLU/BLK
PIN 1 1
RH1
4
SENSOR GRY/BLK BLK/PNK
REFRIGERATOR LEDS
PIN 8
12 +5V DC RL8 PIN 6

WHT/GRN WHT/GRN
3
J2 6
LT. BLU
NEUTRAL
WHT/RED
4
WHT/RED
+12V DC
U2 (SSR1) J3 6 RED
CONDENSER FAN
WHT/GRN 3

WHT/RED 1

5
4

WHT/BRN WHT/BRN
WHT/GRN
WHT/GRN
WHT/RED
WHT/RED

YEL FREEZER ICEMAKER


WHT/BLU WHT/BLU
6 +12V DC WATER VALVE
LT. BLU
PIN 2 YEL/WHT 1 MAIN INLET
J4
2
WATER VALVE
EVAPORATOR
FAN (DC)
1 PIN 1
RED/WHT
2 +12V DC YEL YEL/BLU
PIN 1
FZ-2 LED LED FZ-1 3 PIN 3 BRN/WHT
9 GND
1
BLK BLK
MB1 LINE PIN 3
BLK/ORN
FREEZER LEDS LT. BLU
RED
1
RED/BLK
11
NEUTRAL J2 5 PIN 2
YEL/PNK
COMPRESSOR YEL/PNK
2
BRN PIN 4
CONTROL SIGNAL BLK RL2
12
BLK/WHT THERMAL
2 +12V DC FREEZER
MB2 FREEZER DOOR
EVAPORATOR CUT-OUT SWITCH
TYPICAL LED CONNECTOR HEATER
1 (DOOR OPEN)
AT1
PIN 6
RED/YEL
5 OUT1A FREEZER
ICE MAKER
4
3
RED/YEL BRN/YEL YEL/BLU
12V DC
BRN/YEL
PIN 5
6 OUT1B (SEE FZ ICE 2
DAMPER
BLK/YEL J5 MAKER DIAGRAM)
1 GRN/YEL
3
MOTOR BLK/YEL
PIN 3 OUT2A
WHT/YEL
WHT/YEL ERF2500++ISO
PIN 2
4 OUT2B
REFRIGERATOR COIL COVER
GROUND
CONTROL BEHIND FRONT
LEFT ROLLER
MB1
FREEZER DOOR
YEL/PNK
PIN 4
YEL/PNK
12
SWITCH YEL/PNK YEL/PNK J5
(DOOR OPEN) BLK/ORN
PIN 5
8 +5V DC
BLK

BOARD-MOUNTED BOARD VIEW


1 AMBIENT THERMISTOR
J8 J9
2 +5V DC
RH1 LH1
FRONT INSIDE 2 4
1 4
J11
J1
VIEW
RL1
INLINE CONNECTOR ABBREVIATION KEY
1 3
ABBR. EXPLANATION RL2
AT1 9 PIN CONNECTION AT AIR TOWER 1
11 12
5 PIN CONNECTION AT THE LEFT AT1 & MB1 MB2 LH1
LH1
DOOR UPPER HINGE J2 J6
3 9 3 2 4 4 2 5 5 RL5 1 2
9 PIN CONNECTION IN THE MAIN 9
BACK VIEW
MB1 BOARD HOUSING BEHIND THE TOE J8
1 RL3 1
GRILLE CATCH LATCH AMBIENT
4 PIN CONNECTION IN THE MAIN AT1 3 1 TEMP
1 3
MB2 BOARD HOUSING BEHIND THE TOE 1 7 7 1
1 1
RL6 SENSOR J4
RL9
GRILLE
J3
9 PIN CONNECTION IN THE MC1 RH1 RL8 1 1
MC1 MACHINE COMPARTMENT TO THE
LEFT OF THE COMPRESSOR 3 9 9 3 2
J7
2 U2 RL4 RL7
2 PIN CONNECTION AT THE RIGHT 1
RH1
DOOR UPPER HINGE
1 1
MC1 1 7 7 1 J5
MB1 MB2
Wire Diagram A06742201

You might also like