MTI Aspiration System

for balancing the


moisture of the mixture.
NW
A 1 20

2 A-A

.2 m
max

NW 125
VACUUM UNIT and VALVE:
5
A Valve for changing from
1 9 Atmosphere to vacuum
including vent unit.
NW 150

AIR VALVE:
3
Fresh air supply for
exchanging the air inside
the heating mixer.
HK KK
2
3, 0 m

FL
JET – FILTER:
DN 50 Engineered to the mixer.
FL BP
(Remarks: The size of the
Jet-Filter is in
NW 200 correspondence to the
24 4
size of the vacuum unit.)
NW 300

2
Function process
Atmosphere /
Process step Remarks Air valve Jet Impuls
Aspiration
M ixer start in Speed I or Air through
close
continues w orking Speed I I BYPASS

Feeding the mixer w ith the Air through


close
major component BYPASS

Feeding the mixer w ith the Air through


close
minor component BYPASS

Air through
End of dosing sequence close
BYPASS

Air through 1-2


Clean Jet - Filter close
BYPASS I mpulse

30 seconds after end of Vacuum


Aspiration start open
dosing sequence (ASPIRATION)

The removing of moisture Vacuum


Mixing phase open
happens between (ASPIRATION)
≈ 85°C (186°F) and
Reaching Vacuum
≈ 105°C (221°F) open
discharging temperature (ASPIRATION)

Air through
Open Discharge close
BYPASS

Air through 1-2


Clean Jet - Filter during discharging close
BYPASS I mpulse

Air through
Close Discharge close
BYPASS

3
Jet-Filter

4
5
MTI Mischtechnik Tel +49 (0) 52 31-9 14-0
International GmbH Fax +49 (0) 52 31-9 14-2 99
Ohmstraße 8 info@mti-mixer.de