Download as pdf
Download as pdf
You are on page 1of 1
STRUCTURAL ARRANGEMENT OF CONE ROOF 2.5 mS DIA <6.0 m eatoe ORRIN: UMITED 2-M16 BOLTS(TYP) RAFTER MC75 8 THK. GUSSET PLATE STANDARD No. 7-68-0663 Rev. 2 300 OUTSIDE CURB ANGLE SECTION: 2-2 PAD PLATE (THICKNESS SAME AS CURB ANGLE) 8 THK. PLATE SEC _: 3-3 2 2 3 SECTION: 1-1 RADIAL RAFTERS MC75 (SEE NOTE 2) (wr. OF ROOF STR. FOR| PLAN 6.0 m 8 TANK = O3T NOTE: 1. FOR GENERAL NOTES REFER STANDARD NO. 7-68-0661. 2. FOR 2.5m DIA. 6 NOS. RAFTERS & 6.0m DIA. 12 NOS. RAFTERS SHALL BE PROVIDED; FOR TANKS OF INTERMEDIATE DIAMETERS THE NO. OF RAFTERS SHALL BE WORKED OUT BY LINEAR INTERPOLATION. 3. FOR CURB ANGLE SIZE STATIC EQUIPMENT DRAWING TO BE REFERRED. a Qe _f 2 oi RTD WO BID SOND xt Se ToT AD NO ESD SMO vam pou — Re a nee Sik Bea ave Pupose auaner_Chaan No » by appa Format Wo BOT Fa Rav ‘Copigh EL ~All ras asad