Test Menu Technical Specifications

Thyroid Infectious Disease Fertility Tumor marker General Information Measurement and Reaction System CL-900i
FT3 HIV Combo Total β-HCG CEA Throughput Up to 180 tests/hour Detection Mode Photon counting Chemiluminescence Immunoassay system
Measurement Principle Signal Detector Photomultiplier (PMT) photo counter
FT4 HBsAg FSH AFP
Micron superparamagnetic particles platform PMT Calibration LED reference module
T3 Anti-HBs LH CA125 With alkaline phosphatase (ALP) labeled reagents Incubation positions 82
T4 HBeAg Prolactin CA15-3 And AMPPD substrate Temperature Accuracy: 37±0.3 °C
TSH Anti-HBe E2 CA19-9 Mixing Unit Non-touch vortexer mixing
Sample Assembly
Anti-TG Anti-HBc E3 FPSA
Sample Feeder Continuous sample loading and offloading Cuvette Loading and Waste Collection
Anti-TPO Anti-HCV TESTO TPSA
Sample positions 50 Cuvette Disposable plastic cuvette
Tg Anti-TP (Syphilis) PROG NSE
Sample Probe Steel probe, liquid level detection, clot detection, Cuvette Loading 88 cuvettes per tray,
rT3 HBeAg quantitative* Free testosterone* CYFRA 21-1 Horizontal and vertical collision protection 2 trays can be loaded in one batch,
TRAB* Anti-HBc IgM* 17-OH PROG* CA72-4 Sample Volume 10~200ul, with increment of 1ul continuous loading and offloading
SHBG* PG I Sample Dilution Automatic dilution with 1:2~1:40 Waste collection Waste container, 200 cuvettes per box

Bone Cardiac AMH* PG II


Reagent Assembly Working conditions
Metabolic CK-MB SCCA
Diabetes Reagent Disk 15 reagent positions, continuous loading, Power Supply 100-240V~50/60Hz
Intact PTH Myoglobin HE4 real-time mixing for magnetic particles Input Power 500VA
Insulin
ProGRP Cooling System 2~8 °C Operating Temperature 15~30 °C
Calcitonin Troponin I C-peptide
CA50 Reagent Pack 50 tests/pack, 100 tests/pack Relative Humidity 35%RH~85%RH, without condensation
Vitamin D total BNP
Reagent Scanning Built-in/External bar code reader Dimension 860mm*740mm*560mm (W*D*H)
CA242
Reagent Probe Steel probe, liquid level detection, clot detection, Weight: 132Kg
Horizontal and vertical collision protection Altitude Height -400m~3000m (70kpa)
Reagent Volume 10~200ul, with increment of 1ul
Adrenal Function Liver Fibrosis ToRCH Anemia

LN Toxo IgG* Ferritin


DHEA-S Substrate System
HA Toxo IgM* Vitamin B12 Substrate Bottle 300/500 tests per bottle, bottom piercing
Cortisol
PIIINP Rubella IgG* Folate Substrate Loading Capable of continuous loading during testing
ACTH
Rubella IgM* Substrate Heating Constant heating
CIV RBC Folate
Aspiration Volume 200ul
CMV IgG*
CMV IgM* Magnetic separation unit
Hypertension Growth Hormone Inflammation
HSV-1/2 IgG* Separation Assembly 3-phase magnetic separation
Angiotension I* PCT
hGH* HSV-1/2 IgM* Temperature Accuracy: 37±0.3 °C
Angiotension II* IGF-1* HSV-1 IgG*
Renin*
HSV-2 IgG*
Aldosterone*

DS’ Screening
PAPP-A*
Free β-HCG*
www.mindray.com
*: in development P/N:ENG-CL-900i-210285X6P-20180725
©2017 Shenzhen Mindray Bio-Medical Electronics Co.,Ltd. All rights reserved.
One of the world's smallest, CL-900i The right size for your lab
fully automated CLIA analyzers

Precise magnetic separation with consistent One-key start


performance reliability Extremely easy to use

Solid-liquid waste separation Intuitive software interface


Environmental friendly Easy access to all functions

Wiper washing technology Continuously loading of User maintenance free lntelligent consumables management
Enhance efficiency and minimize carryover reagents and consumables Lighten the workload