Pwa Roads & Drainage Cad Standards Manual Ver 5.0

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 208

PWA CAD STANDARDS MANUAL V 5.

0
September 2017

PWA CAD STANDARDS MANUAL


ROADS & DRAINAGE
Version 5.0
September 2017

Doc Ref # EBD/EIS/IACADSTD/VER 5.0

Prepared by:

Engineering Business Department (EBD-EIS)

Page 1 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Acknowledgement

These Standards represents the extensive effort and support of many individuals within Public

Works Authority. Engineering Information Section expresses appreciation of the valuable

assistance given by the Directors, Managers and Head of departments. Without their co-

operation, the extensive work involved in compiling the background information and preparing

the standards would not be possible.

We would also like to place on record our appreciation to the coordinators who rendered

valuable advice and guidance in bringing these standards to completion and in editing the text

for publication.

Special thanks to

Director of Infrastructure Affairs

Director of Asset Affairs

Director of Building Affairs

Director of Technical Affairs

Page 2 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Document Control

Version Date Modified by Agency Purpose


Version 1.0 March 5,2007 Ashghal
Version 2.0 November 20, 2012 Ashghal
Version 3.0 September 12, 2013 Ashghal
Version 3.1 January 16, 2014 Ashghal
Version 4.0 October 25, 2014 Ashghal
Version 5.0 September 25, 2017 Ashghal

Additions / Revisions

This standard is intended to be neither static nor all-inclusive and thus will be updated and
enhanced as appropriate. Suggestions for improvements are strongly encouraged so that
subsequent updates will reflect the input and needs the current format will undergo versioning
or changes when new technologies become available. Addendum to these standards will be
issued when such changes are made.

In general, changes to these standards shall occur because of three primary factors:

1) Additional users and functionality.


2) Discovery of, and subsequent fixing of latent errors and omissions.
3) Changes to utilize advantage of latest technologies and software versions.

Therefore, it is reasonable to expect updates to this document. Users are cautioned to inquire
about changes within. In order to ensure the reader is using the latest version, a revision date
will be shown in the document control.

Page 3 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

CAD STANDARDS: Control and Authorization

The Standards are under Engineering Business Department Management.


Document Title: PWA CAD STANDARDS MANUAL V 5.0
Date: 25th September 2017
Document Owner: ASHGHAL

Document Approval: Dr. Eng. Saad bin Ahmed Al Mohannadi


President
ASHGHAL

Document Approval:
Mr. Abdulsamad Mohd S M Al-Makei
Manager
Engineering Business Department

Document Authorization:
Mr. Issa Omran I M Al Kuwari
Head of Engineering Information Section
Engineering Business Department
Phone: 4495 0040
E-Mail: ikuwari@ashghal.gov.qa

Document Coordinators: Mr. Thirunavukkarasu Ramalingam / Mr. Khadar Basha Shaik


Phone: 4495 0145 / 4495 0148
E-Mail: tramalingam@ashghal.gov.qa / kshaik@ashghal.gov.qa

Page 4 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

CAD STANDARDS: Distribution

The Master or Original Version of the PWA CAD Standards Manual is held electronically in
ASHGHAL’s Information Services Department. The copy of this PWA CAD Standards Manual is
available on our website (www.Ashghal.gov.qa or www.Ashghal.com) and with all PWA
department directorates.

CAD STANDARDS: Authorization and Change

This PWA CAD Standards Manual will undergo continuous reviews and updates, subject to
change, by the Management of ASHGHAL. Any changes or updates will be announced on our
website (www.Ashghal.gov.qa or www.Ashghal.com).

DISCLAIMER:

This PWA CAD Standards Manual is a property of Ashghal. Copying, circulating in parts or in

any form without Ashghal permission is not permitted. Hardcopies of this document are

considered uncontrolled. Please refer to PWA website for the latest version.

Page 5 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Table of Contents

1 Overview 8
1.1 Purpose 8
1.2 Application 8

2 Standards 9
2.1 Introduction 9
2.2 Objectives 9

3 CAD 10
3.1 General 10
3.2 Ashghal Standard Layer Templates 10
3.3 Drawing Borders 11

4 Filing and Storage of Drawings 11


4.1 Filing and Storage of Drawings 11
4.2 Electronic Copies 11
4.3 Folder Structure 11
4.4 Folder Name: Project Number and Title 12
4.5 Sub Folder Name: CAD 12
4.6 Collaborative Working 13
4.7 Hard Copies 15

5 Drawing Development 16
5.1 Drawing Numbering System 16
5.2 Model File (XRef) Naming 17
5.3 Drawing Title Blocks, Signatures, and Logos 18
5.4 Global Origin and Orientation 26
5.5 Units 27
5.6 Drawing Sizes 28
5.7 Scales 29
5.8 Key Plan 31
5.9 Drawing Notes 31

Page 6 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.10 General Notes 31


5.11 Reference Files 32
5.12 Drawing Revision 32
5.13 Drawing Register and Transmittal Record 34
5.14 Checking and Approval of Drawings 34
5.15 Safety, Health & Environmental (SHE) Box 37

6 CAD Standards 38
6.1 Drawing set up 38
6.2 Line Work 38
6.3 Text 40
6.4 Dimensioning 42
6.5 Standard Symbols and Blocks 42
6.6 Hatching 42
6.7 Colours 43
6.8 Layering 44
6.9 Reference Files (Xrefs) 48
6.10 Plotting 45
6.11 Data Submission Standards 46

7 Other Standards 48
7.1 Summary 48
7.2 Survey 48
7.3 MMUP 49
7.4 Utility CAD Standards 50
50

Appendix A AUTOCAD LAYER DEFINITIONS

Appendix B USEFUL TABLES FOR AUTOCAD

Appendix C DRAWING TYPE AND DRAWING NUMBER SERIES

Appendix D CAD COMPLIANCE CHECK LIST

Appendix E SAMPLE SPREADSHEET FOR PROPOSING NEW CAD LAYERS

Page 7 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

1 OVERVIEW

1.1 Purpose
Public Works Authority - Engineering Information Section (PWA - EBD / EIS) produced
this manual with the objective to ensure compatibility and transference of digital data
between all parties. The goal is to create an environment for seamless integration
between CAD and GIS. The document will achieve this through setting out the
standards for drawing data production. This will then enable drawing data to be
incorporated into the GIS through:

i. Simple data translation.


ii. Common language.
iii. Ease of data storage.
iv. Common medium of information exchange.
v. Drawings and data integration with other applications.
For complete guidelines on GIS database development refer to PWA GIS
Standards Manual.

1.2 Application
The Computer Aided Design (CAD) Standards Manual shall be applied to all disciplines
in all offices and design houses, working on PWA projects. The scope of this document
is to provide guidelines and procedures for adopting AutoCAD standards in preparing
design and as-built drawings for seamless integration with GIS. These standards will
address the following:
i. Drawing file naming convention
ii. Layers names and layer properties.
iii. Symbol blocks & Title blocks.
iv. Drafting standards.
v. Colour usage associated with line widths for all Roads & Drainage drawings.

The standards are to be applied for all drawings from Concept through to As Built
handover stage.

Page 8 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

2 STANDARDS

2.1 Introduction
These standards are aimed to serve all the departments within Ashghal and
consultants / contractors. It has recognized that all workflows have some common
characteristics, enabling them potentially to achieve a level of interoperability through
the use of common standards for various functions. It is intended that such standards
and specifications will enable interoperability between heterogeneous workflows
thereby improving the opportunities for the effective use of workflow process within
Ashghal and the outside domains.

Ashghal is committed to enforce the standards of information delivery that ensures


predictability and the ability to easily reuse information. As a result this CAD standard
will be included as part of the contractual requirement for delivery of digital
information to Ashghal.

This document stipulates the CAD standards to be adopted on projects from design to
construction.

This standard is intended to be neither static nor all-inclusive and thus will be updated
and enhanced as appropriate. Suggestions for improvements are strongly encouraged
so that subsequent updates will reflect the input and needs. Addendum to these
standards will be issued when such changes are made.

2.2 Objectives
This document is intended to address the following principal objectives:

i. To ensure that the CAD drawing files produced by all CAD users are formed and
referenced in a consistent and compatible manner
ii. To standardise the format and content of CAD files throughout where these are
common to all disciplines; such as drawing borders, title blocks, north arrows,
grid lines etc.,

Page 9 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

iii. To ensure a consistent approach to CAD activities and best practices across all
users. Benefits include common levels of understanding and competency, which
will facilitate more effective working.

iv. To provide the means by which all CAD users and other staff involved in
drawing production are kept informed of changes to these standards and
requirements.

3 CAD

3.1 General

Drawings that are produced by CAD that are subsequently amended with
manual corrections will not be permitted, as this can lead to future revision
discrepancies.

3.1.1 File Setup

Ashghal will provide consultants and contractors an AutoCAD template on a CD- ROM
with project boundaries containing policy plan and topographic features as base map
(site Plan) which are geo referenced as per QND 1995 (Qatar National Grid). All the
features of the projects must be drawn onto that template only.

It is the responsibility of the submitting party to organize drawing information


coherently as mentioned in the standard and maintain a reasonable file size.

3.2 Ashghal Standard Layer Templates


CAD drawings will be created using the latest versions of the Ashghal Standard Layer
Templates provided with this manual (refer to Appendices). CAD users are not
permitted to edit or modify the templates.

Page 10 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

3.3 Drawing Borders


Details of drawing border and its filename for AutoCAD are as Table 1 below.

Table 1 :

Drawing Borders – AutoCAD

Drawing Size Description File Name (.dwg)

A1 A1 – Right hand title block PWA_TEMPLATE-A1.dwg

4 FILING AND STORAGE OF DRAWINGS

4.1 Filing and Storage of Drawings


In order that the project information is readily accessible it is essential that all drawing
data is filed and stored in a consistent and logical manner.

4.2 Electronic Copies


All electronic drawing and sketch files associated with a particular project will be filed
within the project folder.

4.3 Folder Structure


The standard folder structure for CAD data is as shown in Figure 1 below, it adopts
the Code of Practice BS 1192:2007 on Common Data Environment for collaborative
working.
Figure 1:

Page 11 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

4.4 Folder Name: Project Number and Title


This can be under the main office or discipline folder, or, if the number of files would
render lists unwieldy, then further sub-folder are permissible. Folder names are not to
include any symbols.

4.5 Sub Folder Name: CAD


Contains drawings and digital information organized as shown in Figure 1.
In a multi-disciplinary office the main sub-folders defined below may be sub-divided as
necessary into the relevant disciplines:

4.5.1 Sub Folder Name: WIP (Work in Progress)

Contains the current working project drawings and sketches. This is where all files
currently in the iterative process of design have not yet been approved to be shared.
This folder will contain further sub-folders which can be amended to suit Consultant’s
individual requirements.

4.5.2 Sub Folder Name: Shared

Contains verified, checked and approved CAD data for use by others for reference. This
folder will hold the project specific drawings such as title frames, references, images,
etc.
This folder will contain further sub-folders which can be amended to suit Consultant’s
individual requirements.

4.5.3 Sub Folder Name: Published

Contains all final published sheet files, figures or sketches. This folder must contain the
last issued Models / Xref’s. Data filed in this area will never be deleted or overwritten,
but will remain until archived.

Page 12 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

4.5.4 Sub Folder Name: Archive

Contains all previous issues and superseded data. This folder is to allow retrieval of
previously issued drawings at certain stages of design decisions. This folder will provide
an audit trail of documentation and changes through the life of the project.

4.5.5 Sub Folder Name: Received

Contains read only copies of design data which have been received from Third Party
sources or Stakeholders and will contain further sub-folders to identify the source and
date of receipt.

The Received folder can be directly under the main project folder structure, under CAD
or wherever the Consultant’s find it suitable.

The vital concern is that a folder must be dedicated for incoming issues, where a full
archive of all received information is stored with an audit trail that is related to the
sending company and the date received and the current copy is easily identifiable
throughout the project.

4.6 Collaborative Working

i. Within WIP folder each discipline can create a folder structure to suit its needs.

ii. Models and sheets in a discipline WIP area may reference own discipline models
in WIP, but models from other disciplines must be referenced from the Shared
area.

iii. Common resource files such as title sheets, mapping, surveys, imagery and
other shared CAD data must be available to all disciplines in the Shared area.

iv. Once data has been checked, verified and approved, it must be copied to the
Shared area and other disciplines notified.

v. When models are revised or updated; other disciplines referencing the model
will be affected, so effective communication between disciplines is essential.

Page 13 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

vi. When data files have been authorised and verified for issue, it is copied to the
Published area, to maintain a local copy within the design organization’s server.

vii. The previous version of the data in the Published area will be moved to the

Archive area as a historical record and to maintain an audit trail.

Figure 2 : Application of Code of Practice BS1192:2007 on Common Data Environment

(CDE)

SHARED WORK IN PROGRESS


Verified design data shared with ( WIP )
the project team. Folders can be S Non-verified design data used by in-house
subdivided into disciplines. h
design team. Folders can be subdivided
a
r into disciplines.
e
EDITABLE DATA OWNED BY ONE PARTY EDITABLE MASTER DATA OWNED BY
TO BE REFERENCED BY OTHERS DESIGN ORGANISATION
[NO REVISIONS/STATUS IN FILE NAMES] [NO REVISIONS/STATUS IN FILE NAMES]
- AutoCAD model files (drawing xrefs) - AutoCAD model files (drawing xrefs)
I
e.g. X2-QN007-KWJ –HW- e.g. X2-QN007-KWJ –HW-
s
ROADS_PROPOSED.dwg s ROADS_PROPOSED.dwg
- drawing borders and templates etc. u
- AutoCAD .dwg sheet drawings
e
- base survey mapping e.g. QN007-P00-KWJ–HW-1001.dwg
- other shared CADD data

PUBLISHED ARCHIVED

Coordinated and validated design Project history maintained for knowledge

output for use by the total project and regulatory and legal requirements.

team. Arc
hiv All formats of data can be stored here –
Latest current issue e changeable and non-changeable formats.
PDFs
Bound DWGs (if required)

Page 14 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

4.7 Hard Copies


The print containing the original stamped, checked and approved signatures becomes
the hard-copy 'master plot' for the drawing. See Section 5.3.13.

Note:
It is vital at all times to maintain absolute correlation between the hard-copy stamped and signed
master and the current electronic version of the drawing or sketch held on the electronic data
storage system. ALL DWG/XREF/Model files will be submitted on a separate CD (or best) via zip
files along with a separate detailed letter of transmittal describing contents along with any
written variation to standard that was not already provided within this document. See section
6.11.1 & 6.11.2 Submissions & File Format.

4.7.1 Drawings

The Consultant’s Project Implementation Plan (PIP) will define the area where the hard-
copies for projects are to be filed.

The electronic version (DWG files) of the master plot of the drawing will be known as
the ‘reference master’. The reference master, is required as part of the submittal, and
will be utilized for the electronic issue of the file.

Superseded master plots will be retained and endorsed "superseded".

Following the close of the project the master plots will be removed from the drawing
office and archived.

4.7.2 Check Prints

All completed and signed check prints will be filed within the drawing office by the
drafting checker in an area in accordance with the Project Implementation Plan (PIP).

All check prints are to be retained at least for the term of the project unless otherwise
agreed with the PWA. No check prints are to be disposed of without the consent of the
Project Manager.

Page 15 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5 DRAWING DEVELOPMENT

5.1 Drawing Numbering System


The drawing names and numbers are to be entered into the drawing register during
creation of the drawings so as to eliminate duplicate drawing numbers being
assigned. The drawing number will be unique for each project and will normally be
as per the drawing naming and numbering convention below.

Table 2 :

Project Package
- - Originator - Type - Number
No. No.

Example QN007 - P01 - KWJ - HW - 1001

See
5.1.1 5.1.2 5.1.3 5.1.4 5.1.5
Reference

Fields will be separated by a hyphen ( - )

Example:

QN007-P01-KWJ-HW-1001

5.1.1 Project Number

A five digit alphanumeric code for PWA Project number.

5.1.2 Package Number

A three digit alphanumeric code to identify the package number. Each package will be
identified by P00, P01, P02, P03 and so on. P00 to be used by projects that have no
packages.

Page 16 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.1.3 Originator Code

A three letter code to identify the Consultant who prepared the drawing. A sample
code of Consultants is shown in Table 3 below.
Table 3 :
Originator CODE Originator NAME
ATK ATKINS
HYD HYDER
PAR PARSONS INTERNATIONAL
KWJ KHATIB & ALAMI - WSP
AEC AECOM

5.1.4 Drawing Type Code

Two letter code to assist in identifying a discipline or particular portion of works. (i.e.
HW for Highways, ST for Structures, LE for Landscape, SK for Sketch, etc.).Refer to
Appendix C.

5.1.5 Drawing Number Code

Four digit sequential number for a specific drawing type series. Refer to Appendix C.
Subsequent issue of a drawing will have the revision coding incremented by the next
sequential number or letter.

Note:
Working drawings will not have the drawing status and revision in the file name.

5.2 Model File (XRef) Naming


Model Files will be named in accordance with the convention described below:
Table 4 :
Model Type Project Drawing
- - Originator - - Short Description
Identifier No. Type

Example X2 - QN007 - KWJ - HW - Proposed_Road

See Reference 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5

Page 17 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Example:

X2-QN007-KWJ-HW-Proposed_Road

5.2.1 Model Identifier Code

This code identifies the model file if it is in 2D or 3D drawing as defined below.

Table 5 :

Description Model Type Identifier

2D Model X2

3D Model X3

5.2.2 Project Number Code

A Five (5) digit alphanumeric code for PWA Project number.

5.2.3 Originator Code

Refer to Section 5.1.3, Table 3.

5.2.4 Drawing Type Code

Refer to Appendix C.

5.2.5 Short Description Field

A short description of the model/Xref file. An underscore is to be used in place of any


spaces in the description field.
Working models will not have the drawing status and revision in the file name.

5.3 Drawing Title Blocks, Signatures, and Logos


A standard drawing arrangement (Drawing Border and Title Block) will be adopted for
all drawings and will be consistent across all drawings within the project. Title block
entries will be concise and informative to indicate fully the content of the drawing.

Page 18 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.3.1 Drawing Title

i. The top line will identify the specific area or section within the contract, i.e.
“HIGHWAYS”, or it may be left blank where no such area or section exists.

ii. The second third and fourth lines will identify the content or purpose of the
drawing, i.e. “TRAFFIC SIGNS AND ROAD MARKINGS”

iii. Where several drawings depict similar detail and no other qualifications are
available for distinguishing between them, the distinction will be made by
labelling each drawing consecutively with sheet numbers, such as “SHEET 1” ,
“SHEET 2”, etc.
Figure 3 :

5.3.2 Drawing Status

The issue DRAWING STATUS box shown below (Figure 4) will be completed to describe
the current status of the drawing. Refer to Table 6 for the list of drawing status/stages:
Figure 4 :

Table 6 :
Drawing Status

Concept Design
Preliminary Design
Detailed Design
Tender
Contract
AsBuilt

Page 19 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

For Corridor Approval drawings:


Table 7 :

Drawing Status

Corridor Approval

Note :
Utility Corridor drawings only get U00, U01, U02 revisions and these will be submitted to both
the utility companies and the PWA as such. They are never given K01, K02, P01 and D01...
revisions. They may be submitted as part of a Concept, Preliminary or Detailed submittal but
would retain their U00, U01, U02... revision status.

5.3.3 Project Name Field

For Project Name refer to Baseline Assessment Report on detailed list of projects.
Figure 5 :

5.3.4 Project Code Field

PWA-specific project codes will be assigned by Ashghal Contracts department.


Figure 6 :

5.3.5 Drawing Date Issued Field

The DATE field will reflect the issue date of a drawing and will be formatted by Month
and Year as highlighted below.
Figure 7 :

Page 20 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.3.6 Revision History Table

A concise description of each approved and issued revision will be entered into the
revision description column. The revision columns indicate the history and development
of the drawing; therefore, the description will be as informative as is practical.

Drawings that are issued under specific Submissions or Milestones sets will have clear,
consistent revision description that states the purpose of the submission. e.g. ISSUED
FOR APPROVAL, etc.

Figure 8 :

The date shown in the revision history table will be in the format DDMMMYY as
highlighted in Figure 9 below:

Figure 9 :

The months will be abbreviated as shown in table 8 below:


Table 8 :
Abbreviation Month Abbreviation Month
JAN January JUL July
FEB February AUG August
MAR March SEP September
APR April OCT October
MAY May NOV November
JUN June DEC December

The date of completion of the revision and the initials of the person effecting the
revision will be stated. The earliest revision descriptions will be deleted when there is no
space to include the current revision within the revision column.

Page 21 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.3.7 Drawing Number Field

Drawing number field will be completed as highlighted in the box below.


Refer to Section 5.1 for drawing numbering convention.
Figure 10 :

5.3.8 Revision Field Box

Revision field box will be completed as highlighted below.


For drawing revision codes refer to Section 5.12.3.
Figure 11 :

5.3.9 Name Fields

The ‘Drawn’, ‘Designed’, ‘Checked’ and ‘Approved’ field boxes on the title block, as
highlighted below, will include the first name initial and the full last name of the person
who performed or is responsible for the major portion of the work.

Figure 12 :

Page 22 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.3.10 Drawing Scale Field

For completing the drawing scale field box in the title frame, refer to Section 5.7

Figure 13 :

5.3.11 Signatures

The revision history table will contain the current issue revision number, date of
issue, Drafter/Author, Checker, Approver signatures or initials and description of
current revision.

Table 9 :

TITLE BLOCK CAD FILE HARD COPY PDF COPY

DRAWN BY See 5.3.12 See 5.3.13 See 5.3.14


CHECKED BY See 5.3.12 See 5.3.13 See 5.3.14
APPROVED BY See 5.3.12 See 5.3.13 See 5.3.14

5.3.12 Drawing File

When issued, drawing files will bear the typed CAD initials of the author, checker and
approver on the revision history box.

Figure 14 : CAD file

Page 23 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.3.13 Hard Copy

The original hard copy set to be submitted to PWA will be signed by hand and stamped.
This set will become the control set for reference. The drawing will bear hand signature
of the drawing Approver beside his/her name in the Approved field box on the title
frame as shown in Figure 15. Each drawing will be stamped with the issuing company’s
official stamp.

Figure 15 : Signed hard copy by Approver

Original hand-signed copy is required for all ‘Final’ drawings submitted for: Concept

design, Preliminary design, Detailed design, Tender set, Contract set, Shop drawings

(during construction) and AsBuilt.

Subsequent hard copies of the submitted original do not have to be hand signed.
Scanned copies of the hand signed drawing are permitted as long as the clarity of the
drawing is not compromised. Alternatively, copies may be printed directly from CAD
files as shown in Figures 16 & 17. It is acceptable for these not to contain a copy of the
hand signature, but to bear typed initials instead.

e.g. in the Revision history box:

Figure 16 : CAD file Figure 17 : Plotted drawing (subsequent hard Copy)

PLO
T

Page 24 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

e.g. in the Approved box:


Figure 18 : CAD File Figure 19 : Plotted drawing (subsequent hard copy)

PLO
T

5.3.14 PDF copy

When Issued, PDF copy can be generated electronically from the cad file bearing the
typed initials of the author, checker and approver.
Figure 20 : CAD file Figure 21 : PDF copy

PLO
T

5.3.15 LOGOS

All Consultant / Agency / Programme Logos are incorporated into the Title Block and
placed on layers that can be turned off.
Figure 22 :

Page 25 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

At Tender, all initials of the author, checker and approver & logos of Consultant’s &
Contractor’s other than the PWA’s will be removed.
But IFC (Issued for Construction) drawings should contain the initials of the author,
checker and approver & logos of Consultant’s & Contractor’s.
Figure 23 :

5.4 Global Origin and Orientation


A consistent approach to drawing global origin and orientation is essential for the
development of multi-disciplinary drawings.

Layouts, general arrangements and detailed plans will clearly mark real world Northing
and Easting values on the drawing file and will be in reference to the QND1995/Qatar
National Grid reference system which is a Transverse Mercator Projection (See Table 9
below for parameters):. These will be in metres.

Table 10 :

Central Meridian 51º 13’ 00” E

Scale Factor at the Central Meridian 0.99999

Location of the Origin 51° 13' 00" E 24° 27' 00" N

False Easting of the Origin 200,000 m

False Northing of the Origin 300,000 m

Reference Spheroid International 1924

Datum QND1995

Page 26 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Where there is a need to create drawings with elements that are not spatially referenced
to a mapping grid, such as standard detail drawings, and these will not need to be
incorporated into the PWA GIS, these elements do not need to be drawn at a specified
coordinate grid system.

5.4.1 Precision

Coordinates are stored in double precision (15 significant digits). Given the coordinate

system defined above, all Easting and Northing will carry six digits before the decimal.

Thus, the coordinate resolution (precision) for vector data is nine significant digits after

the decimal.

5.5 Units
All general drawing work (e.g. Xrefs) are to be in model space and be produced in
meters to three decimal places. Drawing borders to be in paper space and in
millimetres.
e.g.
27.500
8.150 (metres)
0.678
Dimensions in metres and using whole numbers, can be expressed using the ‘m’ (metre)
suffix as in the following:
15.000m
The position of the decimal point will be the same as a full stop and no space will be left
between the number and its units, to ensure clarity, as in the following example:
9.900m
All other non-linear measurements, e.g. areas and volumes, will be followed by the unit
symbol. The most common non-linear measurements are as follows:

Square metre – m²
Cubic metre – m³

Page 27 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

All detail drawing work (e.g. standard details) is to be in model space and be produced
in millimetres in whole numbers (i.e. no decimal places).

e.g.
275

10000 (millimetres)

150

Dimensions in millimetres using whole numbers, can be expressed using the ‘mm’
(millimetre) suffix as in the following:

150mm

Chainages will be in metres and written as shown:

e.g.

Chainages in whole numbers can be written without the


0+100
decimal accuracy

1+750.123
(metres)
10+850.123

Chainages are plan measurements taken along a setting out line, and provide a
horizontal distance not taking into account slope lengths.

5.6 Drawing Sizes


Drawing sizes will conform to the International Standards Organisation (ISO).
Sizes (in mm) are as follows: -
A0 – 1189 x 841
A1 – 841 x 594
A2 – 594 x 420
A3 – 420 x 297
A4 – 297 x 210

Page 28 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

In general, all drawings will be produced at the preferred A1 original size. The use of A0
size drawings will be avoided wherever possible.

Each group or set of drawings will use only one drawing size unless situations make this
impractical.

5.7 Scales
Scales used on drawings will be selected as indicated in the table below. Only

standard metric scales will be used. In all cases, the selected scale will be large enough

to permit easy and clear interpretation of the information depicted.

Specific scale requirements of particular drawings such as layouts will be as stated in


the Consultant’s Project Brief.

Table 11 :

Permitted scales

1:1 1:2 1:5 2:1

1:10 1:20 1:25 1:50 5:1

1:100 1:200 1:250 1:500 10:1

1:1,000 1:2,000 1:2,500 1:5,000 20:1

1:10,000 1:20,000 1:25,000 1:50,000 50:1

In exceptional cases where for functional reasons the recommended scale cannot be

applied, intermediate scales may be chosen, provided that the required scale is of a

whole number, such as 1:125, 1:150, etc.

The following scale notes will be considered:

i. Number of scales on any one drawing will be kept to a minimum.

ii. CAD entities will be drawn at full scale (1 Drawing unit = 1 Measurement unit).
Final plotted scale will be established during composition of the drawing layout
for plotting.

Page 29 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

iii. Originators using AutoCAD will employ the PAPER SPACE/ MODEL SPACE facility
to establish drawing layout and scales. All drawing entities will reside in MODEL
SPACE with the exception of view ports, general notes, revision clouding and its
labels, title block and border.

iv. Where different scales exist, each scale will be specified under the title of the
area of the drawing to which it applies and noted in the Title Block field as shown
below:

Figure 24 :

v. Where a single scale is used on a drawing, it will be specified within the title
block only. (See below). The scales selected will depend on the object area and
will be large enough to permit easy and clear interpretation of information and
ensure clarity of prints on the original as well as reduced copies i.e. A3 versions
of A1 drawings.
Figure 25 :

vi. Where different scales are used for horizontal and vertical dimensions, such as in
profiles, each scale will be clearly indicated on the drawing as shown below:
Figure 26 :

vii. When the drawing is not drawn to any scale, ‘NTS’ (Not to Scale) will be placed
in the title block as shown below:
Figure 27 :

viii. Scale bars will be shown on all drawings containing plans.

Page 30 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.8 Key Plan


Where layout plans are produced on a number of drawings to cover the extent or
section of the project, a Key Plan will be included on each sheet, clearly indicating the
section of the works under consideration. A dedicated box in the title frame is provided
for the Key Plan as shown below.

Figure 28 :

5.9 Drawing Notes


Notes are to be numbered and positioned appropriately and will include the following
notes:

i. All Dimensions are in metres unless otherwise stated. (Only on drawings drawn
in metres.)

ii. All levels in metres above Qatar National Datum. (Only on drawings where this
note is applicable.)

iii. All dimensions are in millimetres unless otherwise stated. (Only on drawings
drawn in millimetres.)

5.10 General Notes


Where notes are extensive and apply on several drawings, a General Notes Drawing
will be provided which consolidates all notes. Deviation from these notes on a
particular drawing may be permitted, provided this amendment is shown in the Notes
section of the drawing.

Page 31 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Where a General Notes Drawing is used, the first note on each applicable drawing will
contain the following statement:
“1. FOR GENERAL NOTES, REFER TO DRAWING NO. XXX “

5.11 Reference Files


Referencing of other CAD files or external files is the method employed for data
sharing. Effective use of CAD reference files ensures that data integrity and accuracy
across disciplines is maintained and the latest, up-to-date revision of the CAD
background is automatically displayed. These will be attached into the appropriate
layer when referenced into the drawing sheets containing the drawing border. Refer
to Section 5.2 for Model File reference naming and Section 6.8 for layering standards.

5.12 Drawing Revision & Status

5.12.1 Revision Clouds and Triangles

i. All revisions on the body of the plotted drawing will be clearly identified by a
revision cloud and triangle.
ii. Each area in which a revision occurs will be ringed with a cloud and marked with
an equilateral triangle containing the current revision letter.
iii. Revision clouds and its triangle label will be placed on the paper space.
iv. Revision clouds and triangles will be placed on layer Z_REV.
v. Clouding and revision triangles denoting the previous revision will be removed
from the CAD file.
Figure 29 :

Page 32 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.12.2 Revision Description

The date and description of the revision / issue will be given in the identified space
within the Title Frame. Refer to Section 5.3.6 for completing the revision history table
on the title frame.

5.12.3 Drawing Revision Code

This code identifies the drawing revision and will be as defined in Table 12 below.

Subsequent issue of a drawing will have the revision coding incremented by the next
sequential number or letter.

All drawings at first issue of all design stages will begin with - alpha character + ‘00’.

Table 12 :
Design Stage Revision Code

Concept Design K00,K01,K02,K03….etc.,


Preliminary Design P00,P01,P02,P03….etc.,
Detailed Design D00,D01,D02,D03….etc.,
Tender TA, TB, TC…….etc.,
Contract CA, CB, CC, CD…….etc.,
AsBuilt Z

For Corridor Approval drawings:

Status Revision / Issue Code

Corridor Approval
U00,U01,U02….etc.,
(see Note in Section 5.3.2)

Note : As drawings move from one stage to another, all historical revision history under that
stage is to be removed from the revision history on the title block.

Page 33 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.13 Drawing Register and Transmittal Record


The issue of drawings will be recorded on the drawing register and a transmittal
provided by drawing originators containing like information. The drawing register will
be a concise and continuous record of drawing revisions and issue history.

The current revision indicator will be recorded for each issue.

5.14 Checking and Approval of Drawings


During drawing production a system of continuous checking will be employed by the
Consultant to confirm that all CAD information fully complies with the conditions set
out in this document.

It is imperative that all drawings are subjected to a Quality Assurance and Quality
Control (QA/QC) check and are duly signed and authorized prior to issue.

The PWA, upon receipt of CAD data, will run an audit on all drawings. All data found
on non-conformance and without an attached variance notation via transmittal, will
be rejected and returned to the Consultant for notation in transmittal/request variance
and/or correction.

Any drawing leaving the drawing office will have been properly checked for
presentation, clarity, accuracy, technical correctness and compliance with the relevant
CAD Standard. Refer to the flow chart overleaf in Figure 30 for an overview of the
checking procedure.

Page 34 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Figure 30 : Flow diagram showing overview of CAD drawing checking procedure

INITIAL
DRAFTING

RAISE AMEND
CHECK PRINT
DRAWING

RAISE
CHECK PRINT

DRAFTING
CHECK ACTION REQUIRED

ENGINEERING
CHECK
ACTION REQUIRED

NO ACTION REQUIRED

SIGN & FILE


CHECK PRINT

RETURN TO
DRAWING ORIGINATOR

PRODUCE FINAL PRINT & HAND SIGNED SIGNATURES OF CHECKERS


AND APPROVER
CREATE PDF RETURN TO
(when required) ETRANSMIT
DRAWING CAD FILES
ORIGINATOR
(For signature requirements on drawings refer to Section 5.3.11)

RECORD DRAWING ISSUE IN REGISTER


ISSUE
AND COMPLETE TRANSMITTAL

Page 35 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.14.1 Self Check

After preparation, the drawing will be checked by the drawing originator and any
required amendment to the drawing is to be carried out prior to handing over the check
print for checking.

5.14.2 Drafting Check

Generally the Drafting Check must precede the Engineering Check.

The Drafting Check will normally be carried out by a person designated by the CAD
Office representative/Manager.

The Drafting Check will verify adherence to the Project Brief in conjunction with any
applicable supplied criteria. The checker will also make an assessment with respect to
presentation, standard of workmanship and adherence to the CAD Standard Manual.

The Drafting Check will, where deemed necessary, include an electronic check of the
CAD File to ensure compliance with applicable standards and/or client requirements.

The check print will be clearly marked by the checker with any required modifications.

Upon completion of the Drafting Check the checker will then sign, date and highlight
the required action to be taken.

Any amendment to the drawing requirements may, if required, be carried out prior to
the Engineering Check and a new print raised, duly stamped and signed.

5.14.3 Engineering Check

The Engineering check will normally be carried out by a competent and relevant
experienced Senior Engineer within the Consultant’s organization.

The Engineering check will verify adherence to the design calculations, design standards
and associated construction issues.

Upon completion of the Engineering Check, the checker will then sign, date and
highlight the required action to be taken.

Page 36 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

5.14.4 Further drawing amendments

Upon completion of the Drafting Check and Engineering Check the completed check
print will be returned to the originator of the drawing for amendment of the drawing.

Where required, further check prints will be raised and the checks repeated.

5.14.5 Approval

Upon completion of the checking process, a clean print of the drawing will be
submitted to the relevant checkers for signature and to the designated authority for
approval. This then becomes the controlled drawing for reference. The checker’s and
approver’s initials together with the relevant dates will be entered in the appropriate
areas of the CAD file.

5.15 Safety, Health & Environmental (SHE) Box


The QCS stipulates that provision of information can be achieved by inclusion of notes
on drawings, as a preferred method, since the notes will then be immediately available
to those carrying out the work. One common technique that is used is the SHE Box.
Details about the SHE box can be found in the ‘Design for Health and Safety’ Standard
(PMC-ST-HSS-020-020 Rev 1). The SHE box appears on drawings at Detailed Design,
Tender & IFC Stages to be issued to contractors. Once construction works are
completed, any residual risk needs to be reported in a similar way on the As-Built
drawings. Placement of the SHE box ideally will be placed in the upper right corner of
the drawing area of each sheet. Should this placement obscure key drawing
information, the consultant’s / contractor’s may move it to a more ideal location on the
drawing to provide clarity. There are no restrictions on how many lines may be used
within the SHE box. Figure 31 : SHE Box

Page 37 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

6 CAD STANDARDS

6.1 Drawing set up


i. Drawing templates will be used for setting the layers of identifiable drawings
(e.g. Roads, Drainage).
ii. Units in AutoCAD will be set to metres for layouts and profiles and millimetres
for detail drawings such as standard details.
iii. The CAD files provided will be in the current version of AutoCAD file format
used on the project.
iv. Fonts and line types are to be followed as provided in this manual.
v. Files will be purged before issue only.
vi. Drawing features / entities must be in model space. Title frames must be in
paperspace.
vii. The colour and line type of each entity is drawn on BYLAYER.
viii. For all general drawing annotations, ISOCP.shx will be used. True type fonts
such as Arial.ttf will be used for presentation drawings and Title frame.
ix. All polygons will be closed polylines.
x. Do not place entities on layer 0. This layer is for the creation of blocks only.

6.2 Line Work

6.2.1 Line Types

The following guidelines will apply to the use of line types:

i. LINETYPE to be set BYLAYER. (Deviation: Standard AutoCAD Blocks)

ii. All layers will have their entities set to ‘BYLAYER’

iii. All colours of AutoCAD objects to be BYLAYER. (Deviation: Standard AutoCAD


Blocks)

iv. The plotted appearance of linetypes will be consistent across all drawings.

v. Modification of AutoCAD default source file is not permitted.

Page 38 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

vi. Lines on a drawing that cannot be represented by those in the default AutoCAD
source file may be loaded from the approved Custom line types provided.

The default AutoCAD source file ACADISO.LIN will be used with the following:

Table 13 :

System
LTSCALE PSLTSCALE MEASUREMENT MEASUREINIT
Variable

Value 1 1 1 1

Custom line types provided:

 PWA_Drainage.lin (accompanied by Drainage.shp & Drainage.shx)


 PWA_Roads.lin
 PWA_Utilities.lin

6.2.2 Line Weights

Table 14 :
Display Screen Plotted Line
Colour No. Plotted Colour
Colour Weight
(mm) PWA_COL_A1.CTB PWA_BW_A1.CTB

1 Red 0.10 BLACK BLACK


2 Yellow 0.25 BLACK BLACK
3 Green 0.35 BLACK BLACK
4 Cyan 0.50 BLACK BLACK
5 Blue 0.70 BLACK BLACK
6 Magenta 0.35 BLACK BLACK
7 White 0.25 BLACK BLACK
8 Dark Grey 0.20 Object Colour BLACK
9 Light Grey 0.15 Object Colour BLACK
10 & 13 Object Colour 0.60 Object Colour BLACK
11,12,14-79 &
Object Colour 0.35 Object Colour BLACK
81-249
80 Object Colour 0.60 Object Colour BLACK
250-255 (Greys) Object Colour 0.15 Object Colour Object Colour

Page 39 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

6.2.3 Xref as Background

The external reference, when used as a background, will be shown as screened or


subdued such that the proposed work is more legible against the background reference.

6.3 Text

6.3.1 General

i. The AutoCAD Styles will have a default height setting = 0.

ii. Sloping, italic, and elaborate fonts are not permitted.

iii. The objective will be to make all lettering highly legible so that information can
be communicated with the minimal possibility of error in reading. Lettering
sizes will be chosen such that it will remain legible when drawings are reduced
to A3 size.

iv. Lettering will be consistent, both in size and placement. Lettering sizes for
specific applications, such as notes or titles, will not vary within the same
drawing.

v. Lettering will be uniform, clear, sharp and distinct. The mixing of lettering
styles, sloping, italic, and elaborate fonts will not be permitted.

vi. All text will be regularly spaced, upright and uppercase and not be underlined.
Deviation Titles under plans, details, etc. are to be underlined.

vii. All text will be left justified. Deviation: Titles will be centre justified and
underlined.

viii. Specific notations will be carefully placed so they relate to the portion of the
drawing or detail to which they apply.

ix. The placing of notes through drawing lines is to be avoided.

x. Leader arrows relating to specific text or annotation will be placed in model


space with the detail it is referencing on the same layer as the text to which it
relates.

Page 40 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

6.3.2 Fonts

Permitted text fonts are as shown below:


Table 15 :

AutoCAD Style Name AutoCAD Font File CAD Usage

STANDARD ISOCP.SHX Technical / Engineering drawings


ARIAL / ARIAL NARROW ARIAL.TTF Presentation Drawings

6.3.3 Text Assignments

The table below indicates approved texts with their appropriate


Colour/application assignments:

Table 16 :

Plotted
Width Plotted Line
Text Height Usage
Factor weight
(mm)

General text, Dimensions, Notes – used


1.8 1 0.18 on A3 & A4 only where drawing is not
plotted at a reduced scale.

General text annotations, Dimensions,


2.5 1 0.25
Notes Special Notes

For more prominent notes or labels


3.5 1 0.35
requiring special emphasis.

Normal Titles, Drawing Numbers,


5.0 1 0.50
Section titles, Detail Titles

7.0 1 0.7 Major Titles

i. The preferred text height for general text and notes is 2.5mm.

ii. The text height adopted for a project will be consistent across all
drawings unless situations make this impractical.

Page 41 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

6.4 Dimensioning
Automated dimensioning commands within CAD software programs will be used for
creation and editing of dimensions, as shown in table 17 below.

The editing of dimension values via basic text editing commands is not permitted.
Dimensions will be associative and placed on their own unique layer.
Table 17 :

Extension
Dimension Extension Stack
Line Arrow Size Centre Mark
Text Height Line Offset Offset
Extension

2.5mm Dimexo = 2 Dimexe = 2 Dimdli = 6.25 Dimasz = 2.5 Dimcen = 1

6.5 Standard Symbols and Blocks


In order to promote consistency, standard symbols will be utilized. All blocks are to be
inserted into the drawing on its appropriate drawing layer. Where a symbol required is
not available from the blocks provided with this manual, symbols compliant to
international standards will be used. These new blocks will be submitted to PWA
through a proper transmittal and action assignment. Email requests will be considered.
PWA will confirm and verify then update the list of standard symbols library and then
reissue a block/symbols library.
All symbols will be consistent within a drawing or set of drawings.
All blocks that need to be created as new blocks will have all their elements saved on
layer 0.
All symbols used within a drawing must be defined using a legend.

6.6 Hatching
Wherever possible, all hatching created will be associative and placed on its own
unique layer. Exploding of hatches must be avoided.

Page 42 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

6.7 Colours
In AutoCAD, entity colour will be assigned “ByLayer”. Deviation can be on standard
blocks, i.e. are Road signs blocks where specific standard colours are assigned for
each.

6.8 Layering
CAD Layering will be in accordance with PWA AutoCAD Layering Standards as
included in Appendix A of this manual.

Additional layers may be required and the naming of such layers will follow format as
shown in Section 6.8.1.

Note :
All new layer names must be forwarded to PWA for review and approval. So as not to hold up
production of drawings, work must continue on any new layers created while design offices
seek PWA approval. If issue is unresolved as project goes to submittal – Consultant to provide
transmittal stating variance from standard and provide detailed description of non-conforming
layers, blocks, linestyles, etc. ALL requests for new symbology to go through a proper
transmittal and action assignment to PWA. Newly proposed layer names must be accompanied
with proper justification and schematics referencing the request. A sample justification
spreadsheet is included in Appendix E.

6.8.1 Layer Name Layout

Where new layers are to be created the AutoCAD layer naming convention is as
follows:
1 2 3
D_EX_SEW_MH

Where:
1 = Department Designator
2 = Status / Section Designator
3 = Feature / Entity Designator

Page 43 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Department Designator (Field 1)


This code identifies the PWA department (i.e. B = Building Affairs, D = Drainage and
RD = Roads.

Status / Section Designator (Field 2)


This code identifies the main classification of the type of element within a discipline. For
example ‘EX_SEW” describes as Existing Sewer.

Feature / Entity Designator (Field 3)


This code further identifies the entity description feature name. For example ‘MH”
describes the Sewer Manhole feature.

List of PWA Standard Layers

See Appendix A.

6.8.2 Drawing Layers

While preparing As-Built Drawings the Layer standards should be updated from

Proposed to Existing, i.e. “_PR_” should be replaced with “_EX_”.

6.9 Reference Files (Xrefs)


i. Where CAD data is to be shared between drawings the use of reference files is
to be adopted.
ii. All reference files are to be inserted in model space with the UCS set to ‘world’.
All files are to be inserted at 0,0,0.
iii. Unused reference files will be detached upon completion of drawings.
iv. The number of reference files on a project will be kept to a minimum.
v. The preferred method of attaching Xrefs will be Overlay option.
vi. Reference files will be inserted on unique layer that does not conflict with the
general content of the drawing. (i.e. layer Z_XREF in AutoCAD).
vii. Reference files will be “CLIPPED” within the Active drawing sheet file to ensure
that only the design data relevant to the drawing is displayed.

Page 44 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

viii. Reference files issued externally or shared between departments will indicate
revised areas with a revision cloud and triangle. A revision history will be
maintained within the reference file. In AutoCAD, the revision history log will be
placed in paper space, see Figure 32 below.
ix. For Model File Naming refer to Section 5.2

Figure 32 :

6.10 Plotting
The following standard colour source files will be used:

Table 18 :

Colour Black and White

PWA _COLOUR_A1.ctb PWA _BW_A1.ctb

PWA_COLOUR_ITS.ctb PWA_BW_ITS.ctb

This standard colour source (CTB) file will be flexible and can be adjusted to suit
Consultant’s need during plotting. When drawing (DWG) files are required as part of a
submittal, the CTB file used for the plotting of the drawings will also be required in the
submittal.

Page 45 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

6.10.1 Date and File location update

These are field entities contained within the drawing border and are used to
print the file name, file location, date and time of print, etc. However, these
Plot-Stamp details shall be removed from the border of Tender drawings.

Figure 33 :

6.11 Data Submission Standards


All drawing files must conform to the PWA CAD Standards set forth in this document.

6.11.1 CAD Compliance Certificate

Prior to submissions of any CAD files, the Consultant must undertake a thorough check
of the CAD datasets to ensure that the requirements of the CAD Standards Manual
have been fully satisfied. The Consultant must make reference to the requirements of
the CAD Compliance Checklist (refer to Appendix D) and ensure that the checkpoints
have been fully satisfied. Once the checklist has been fulfilled, the Consultant must
generate a CAD Compliance Certificate to be signed by a person authorized by the
company to confirm adherence to the standards. The signed CAD Compliance
Certificate will be required as attachment with the submission of final drawings (CAD
files) during the design stages and for as-built drawing submissions during handover
stage.

6.11.2 Submission

Submittals at each level of design will be in hard copy and soft copy digital format per
requirements in the Project Brief. The digital submittal will not be locked to prevent
PWA from extracting or editing content of the submittal. Furthermore, the digital
submittal will be produced in PDF format and the original format of the deliverable for
each level of design.

Page 46 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Table 19 : Levels of Design

Drawing Status

Concept Design
Preliminary Design
Detailed Design
Tender
Contract
As-Built

All CAD drawings to be submitted must conform to PWA’s standard of a single sheet

layout per drawing. Due to file size and volume of data sets, CAD Drawings & Technical

Engineering Models, as the deliverables are defined as per the Consultant Project Brief,

will be delivered via best means (transmittal + CD, Portable drive). This Visualization

Simulation and Technical Engineering Model data is to be delivered separate from other

documents that are delivered at the same time. It is required that there be a Letter of

Transmittal and a full description of data included; listing of files, project area,

Consultant project number, title and date of submission to be included, along with any

variances to standards as published.

6.11.3 File Format

Digital submittals will be in both DWG and PDF format. DWG files will be delivered via
best means (Consultant to submit with transmittal + CD, Portable drive) in ZIP format.

Page 47 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Table 20 : Technical Model Data Formats

7 OTHER STANDARDS

7.1 Summary
For consistency in production the following external CAD standards will be followed:

7.2 Survey
Qatar Survey Manual: Urban Planning & Development Authority / The Centre for GIS –
State of Qatar

All surveys conducted in accordance to the standards and specifications as laid out in
Qatar Survey Manual will be assured of the same level of consistency and accuracy. This
will ensure the reliability of all the survey data and enhance the confidence level of all its
users. With this standardized survey data, it can be uploaded onto the Qatar GIS system
as seamlessly as possible.

Link: http://www.gisqatar.org.qa/en

Page 48 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

7.3 MMUP

7.3.1 Ministry of Municipality & Urban Planning (MMUP) - Urban Planning &
Development Sector

In accordance with the Memorandum of Understanding between MMUP-Urban


Planning Sector and Public Works Authority – December 2012 Notes, Section 6.
Land Expropriation CAD Format and Drawing template is attached. Soft Copy
should be requested from PWA. The following CAD layers, line types and
hatching are to be used for all Land Acquisition Drawings.

Table 21 :

Notes on drawing set up:

To ensure consistency for all land expropriations drawing produced, the following
layering sequence to be used for the drawing objects (1 being the top layer followed by
2,3, and so on):

1. Viewport text and notes (top)


2. Proposed right of way (red dotted lines)
3. Land expropriation hatching (purple on top, then yellow, green, blue)
4. Existing right of way (blue lines)
5. Survey parcel / plot boundary (green lines)
6. Road design Layout (greyscale/fine black lines)
7. Aerial image (bottom)
The drawings to be kept clean by placing text (coordinates, etc.) and annotations away
from engineering lines and color hatching (land expropriation).

Page 49 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

A transparency value of 60 to be used for hatching layers (yellow, Cyan and green) to
allow showing the aerial image background. The purple hatch for buildings to be in
front of the yellow, cyan, and green hatch to avoid color change. The purple hatch will
not have transparency to avoid change in color if placed on top of the other transparent
color hatch.

The proposed right of way (red dotted lines) to be on top of the existing right of way
(blue dotted lines). The proposed right of way to only include the additional right of way
required for the new road project.

7.3.2 MMUP Typical Road Cross-sections and Utility Corridors

Consultant’s to contact MMUP for standards. When submitting typical cross section
drawings to MMUP, Consultant’s to use MMUP standard color coding as MMUP
specified.

7.4 Utility CAD Standards

Consultant’s to contact Utility Authority (i.e. KAHRAMAA, Ooredoo, Vodafone, or others) for

CAD Plan Preparation Standards. If no other Utility standard is in place by the given Utility

Authority, then the Utility standards as outlined in this manual will take precedent.

Page 50 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix A – AUTOCAD LAYER DEFINITIONS

Page 51 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

A.1 General Layers

Screen Plotted Line


Layer Name Linetype Description
Colour weight

Z_18TEXT RED CONTINUOUS 0.10 TEXT AT RESPECTIVE HEIGHT


Z_25TEXT WHITE CONTINUOUS 0.25 TEXT AT RESPECTIVE HEIGHT
Z_35TEXT GREEN CONTINUOUS 0.35 TEXT AT RESPECTIVE HEIGHT
Z_50TEXT CYAN CONTINUOUS 0.50 TEXT AT RESPECTIVE HEIGHT
Z_70TEXT BLUE CONTINUOUS 0.70 TEXT AT RESPECTIVE HEIGHT
Z_DIMS RED CONTINUOUS 0.10 ALL DIMENSIONS
Z_DWG_GRID 251 CENTER2 0.15 DRAWING / MAP GRID LINES
Z_DWG_SHT WHITE CONTINUOUS 0.25 DRAWING SHEET & TITLE BLOCK
Z_MATCHLINE BLUE PHANTOM 0.70 MATCHLINE
Z_NORTH GREEN CONTINUOUS 0.35 NORTH DIRECTION SYMBOL
Z_REV YELLOW CONTINUOUS 0.25 REVISION CLOUDS AND TRIANGLES
Z_SCALE WHITE CONTINUOUS 0.25 GRAPHIC SCALE
Z_SECMK GREEN CONTINUOUS 0.35 SECTION AND DETAIL MARKS
Z_SYM WHITE CONTINUOUS 0.25 SYMBOLS
Z_TAG WHITE CONTINUOUS 0.25 DRAWING TAG
Z_VPORT WHITE CONTINUOUS 0.25 VIEWPORT
Z_XREF WHITE CONTINUOUS 0.25 EXTERNAL REFERENCE (XREF)

Page 52 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

A.2 GIS Layers

GIS LAYERS
Plotted
Screen
Layer Name Linetype Line Description
Colour
weight

GIS_ACQ_BDRY 20 ACAD_ISO13W100 0.25 LAND ACQUISITION BOUNDARY


GIS_CADASTRAL RED CONTINUOUS 0.10 CADASTRAL PLOT
GIS_CNTRS 9 CONTINUOUS 0.15 CONTOURS
GIS_CNTRS_TEXT RED CONTINUOUS 0.10 CONTOURS TEXT
GIS_CSTL 90 CONTINUOUS 0.35 COASTLINE

STATION NAME, EASTING,


GIS_CTRL YELLOW CONTINUOUS 0.25
NORTHING, HEIGHT, ACCURACY
RATINGS, ETC.

GIS_DIST 72 ACAD_ISO12W100 0.35 DISTRICT


GIS_FLOWLINE 8 CONTINUOUS 0.20 FLOWLINES
GIS_MUNC 200 ACAD_ISO10W100 0.35 MUNICIPALITY
GIS_PPLN 252 CONTINUOUS 0.15 POLICY PLAN
GIS_PRJ_BDRY 222 ACAD_ISO14W100 0.35 PROJECT BOUNDARY
GIS_RD01 121 CONTINUOUS 0.35 MAJOR ROAD
GIS_RD02 151 CONTINUOUS 0.35 MINOR ROAD
GIS_RD03 181 CONTINUOUS 0.35 STREETS
GIS_ROW_BDRY 170 PHANTOM2 0.35 RIGHT OF WAY BOUNDARY
GIS_ZONE 13 CONTINUOUS 0.60 ZONE

Page 53 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

A.3 Drainage layers


A.3.1 Surface Ground Water

PROPOSED SURFACE GROUND WATER (SGW)

Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SURFACE GROUND


D_PR_SGW 80 SGW_PR 0.60
WATER LINES
PROPOSED SURFACE GROUND
D_PR_SGW_ATT YELLOW Continuous 0.25 WATER LINE ATTRIBUTES (ID,
DIAMETER, LENGTH, MATERIAL, ETC.)
D_PR_SGW_AVCH 90 Continuous 0.35 PROPOSED SGW AIRVALVE CHAMBER
D_PR_SGW_BD 90 Continuous 0.35 PROPOSED SGW BACK DROP

D_PR_SGW_BY_ PROPOSED SURFACE GROUND


160 SGW_PR 0.35
OTHERS WATER LINES BY OTHERS
PROPOSED SGW BRIDGE DECK
D_PR_SGW_BDDAU 90 HIDDEN2 0.35
DRAINAGE ACCESS UNIT
PROPOSED SGW BRIDGE DECK
90 HIDDEN2 0.35
D_PR_SGW_BDDOU DRAINAGE OUTLET UNIT
PROPOSED SGW BRIDGE DECK
90 HIDDEN2 0.35
D_PR_SGW_BDDU DRAINAGE UNIT
PROPOSED SGW DISCHARGE
D_PR_SGW_DCH 90 Continuous 0.35
CHAMBER
D_PR_SGW_DT 90 Continuous 0.35 PROPOSED SGW DRAIN TRENCH
D_PR_SGW_DUCT 30 Continuous 0.35 PROPOSED SGW DUCT
D_PR_SGW_FCH 90 Continuous 0.35 PROPOSED SGW FLUSHING CHAMBER
D_PR_SGW_FLOW WHITE Continuous 0.25 PROPOSED SGW FLOW ARROW
D_PR_SGW_GC 90 Continuous 0.35 PROPOSED SGW GULLY CONNECTION
PROPOSED SGW GULLY CONNECTION
D_PR_SGW_GC_ST_E 90 Continuous 0.35
STUB END CAP
PROPOSED SGW GULLY CONNECTION
D_PR_SGW_GC_ST_P 90 Continuous 0.35
STUB END PIPE

Page 54 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED SURFACE GROUND WATER (SGW) (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

D_PR_SGW_GL 90 Continuous 0.35 PROPOSED SGW GULLY

D_PR_SGW_HP WHITE Continuous 0.25 PROPOSED SGW HIGH POINT


PROPOSED SURFACE GROUND WATER
D_PR_SGW_HTANK 90 Continuous 0.35
/ STORM WATER HOLDING TANK
PROPOSED SGW INSPECTION
D_PR_SGW_ICH 90 Continuous 0.35
CHAMBER
D_PR_SGW_LD 90 Continuous 0.35 PROPOSED SGW LAND DRAIN

D_PR_SGW_LP WHITE Continuous 0.25 PROPOSED SGW LOW POINT


D_PR_SGW_LRD 130 Continuous 0.35 PROPOSED SGW LINEAR ROAD DRAIN

130 Continuous PROPOSED SGW LINEAR ROAD DRAIN


D_PR_SGW_LRDO 0.35
OUTLET
D_PR_SGW_MH 90 Continuous 0.35 PROPOSED SGW MANHOLE
D_PR_SGW_MT 90 Continuous 0.35 PROPOSED SGW MICROTUNNEL LINES
PROPOSED SGW MICROTUNNEL
D_PR_SGW_MTMH 90 Continuous 0.35
MANHOLE
D_PR_SGW_OFCH 90 Continuous 0.35 PROPOSED SGW OUTFALL CHAMBER
D_PR_SGW_PS 90 Continuous 0.35 PROPOSED SGW PUMPING STATION
D_PR_SGW_RM 90 RM_PR 0.35 PROPOSED SGW RISING MAIN
PROPOSED SGW RISING MAIN
D_PR_SGW_RM_ DIA YELLOW Continuous 0.25
DIAMETER
PROPOSED SGW SOAKAWAY
D_PR_SGW_SAW_MH 90 Continuous 0.35
MANHOLE
D_PR_SGW_ST_E 90 Continuous 0.35 PROPOSED SGW STUB END CAP
D_PR_SGW_ST_P 90 Continuous 0.35 PROPOSED SGW STUB END PIPE
PROPOSED SGW SURFACE WATER
D_PR_SGW_SWC 10 DASHED2 0.60
CHANNEL

Page 55 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED SURFACE GROUND WATER (SGW) (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SGW SURFACE WATER


D_PR_SGW_SWCO 10 Continuous 0.60
CHANNEL OUTLET
D_PR_SGW_TBMM 90 Continuous 0.35 PROPOSED TUNNEL BORING MACHINE

D_PR_SGW_TDS 90 Continuous 0.35 PROPOSED TUNNELING DRIVE SHAFT


D_PR_SGW_TRS 90 Continuous 0.35 PROPOSED TUNNELING RECEPTION
D_PR_SGW_TUNNEL 80 PR_TUN_SW 0.60 SHAFT
PROPOSED SGW TUNNEL LINE

D_PR_SGW_VALV 90 Continuous 0.35 PROPOSED SGW VALVE

D_PR_SGW_VC 90 Continuous 0.35 PROPOSED SGW VALVE CHAMBER


D_PR_SGW_VDP 170 Continuous 0.35 PROPOSED SGW VERTICAL DOWN PIPE
PROPOSED SGW VERTICAL DOWN PIPE
D_PR_SGW_VDPO 170 Continuous 0.35
OUTLET
D_PR_SGW_WCH 90 Continuous 0.35 PROPOSED SGW WASHOUT CHAMBER

EXISTING SURFACE GROUND WATER (SGW)

Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SURFACE GROUND WATER


D_EX_SGW 96 SGW_EX 0.35
LINES
EXISTING SURFACE GROUND WATER
D_EX_SGW_ATT WHITE Continuous 0.25 LINE ATTRIBUTES (ID, DIAMETER,
LENGTH, MATERIAL, ETC.)
D_EX_SGW_AVCH 96 Continuous 0.35 EXISTING SGW AIRVALVE CHAMBER
D_EX_SGW_DCH 96 Continuous 0.35 EXISTING SGW DISCHARGE CHAMBER
D_EX_SGW_DT 96 Continuous 0.35 EXISTING SGW DRAIN TRENCH
D_EX_SGW_DUCT 30 Continuous 0.35 EXISTING SGW DUCT
D_EX_SGW_FCH 96 Continuous 0.35 EXISTING SGW FLUSHING CHAMBER

Page 56 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING SURFACE GROUND WATER (SGW) (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
EXISTING SGW FLOW DIRECTION
D_EX_SGW_FLOW WHITE Continuous 0.25
ARROW
D_EX_SGW_GC 96 HIDDEN2 0.35 EXISTING SGW GULLY CONNECTION

EXISTING SGW GULLY CONNECTION


D_EX_SGW_GC_ ST_E 96 Continuous 0.35
STUB END CAP
EXISTING SGW GULLY CONNECTION
D_EX_SGW_GC_ ST_P 96 HIDDEN2 0.35
STUB END PIPE
D_EX_SGW_GL 96 Continuous 0.35 EXISTING SGW GULLY

D_EX_SGW_HP WHITE Continuous 0.25 EXISTING SGW HIGH POINT


EXISTING SURFACE GROUND WATER /
D_EX_SGW_HTANK 96 Continuous 0.35
STORM WATER HOLDING TANK
D_EX_SGW_ICH 96 Continuous 0.35 EXISTING SGW INSPECTION CHAMBER

D_EX_SGW_LD 96 Continuous 0.35 EXISTING SGW LAND DRAIN

D_EX_SGW_LP WHITE Continuous 0.25 EXISTING SGW LOW POINT


D_EX_SGW_MH 96 Continuous 0.35 EXISTING SGW MANHOLE
D_EX_SGW_MT 96 Continuous 0.35 EXISTING SGW MICROTUNNEL LINES
EXISTING SGW MICROTUNNEL
D_EX_SGW_MTMH 96 Continuous 0.35
MANHOLE
D_EX_SGW_OFCH 96 DASHED2 0.35 EXISTING SGW OUTFALL CHAMBER
D_EX_SGW_PS 96 Continuous 0.35 EXISTING SGW PUMPING STATION
D_EX_SGW_RM 96 RM_EX 0.35 EXISTING SGW RISING MAIN
D_EX_SGW_RM_DIA WHITE Continuous 0.25 EXISTING SGW RISING MAIN
DIAMETERSGW SOAKAWAY
EXISTING
D_EX_SGW_SAW_MH 96 Continuous 0.35
MANHOLE

D_EX_SGW_ST_E 96 Continuous 0.35 EXISTING SGW STUB END CAP


D_EX_SGW_ST_P 96 HIDDEN2 0.35 EXISTING SGW STUB END PIPE

Page 57 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING SURFACE GROUND WATER (SGW) (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

D_EX_SGW_TDS 96 Continuous 0.35 EXISTING TUNNELING DRIVE SHAFT

EXISTING TUNNELING RECEPTION


D_EX_SGW_TRS 96 Continuous 0.35
SHAFT
D_EX_SGW_VAL 96 Continuous 0.35 EXISTING SGW VALVE
D_EX_SGW_VC
V 96 Continuous 0.35 EXISTING SGW VALVE CHAMBER
D_EX_SGW_WC 96 Continuous 0.35 EXISTING SGW WASHOUT CHAMBER
H
A.3.2 Foul Sewer

PROPOSED FOUL SEWER (SEW)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
PROPOSED SEWER ATTRIBUTES (ID,
D_PR_SEWER_ATT YELLOW Continuous 0.25
DIAMETER, LENGTH,MATERIAL, ETC)
PROPOSED SEWER AIRVALVE
D_PR_SEW_AVCH 20 Continuous 0.35
CHAMBER
D_PR_SEW_BY_
160 Continuous 0.35 PROPOSED SEWER LINES BY OTHERS
OTHERS
PROPOSED SEWER DISCHARGE
D_PR_SEW_DCH 20 Continuous 0.35
CHAMBER
D_PR_SEW_DUCT 20 Continuous 0.35 PROPOSED SEWER DUCT
PROPOSED SEWER FLUSHING
D_PR_SEW_FCH 20 Continuous 0.35
CHAMBER
PROPOSED SEWER FLOW DIRECTION
D_PR_SEW_FLOW YELLOW Continuous 0.25
ARROW
PROPOSED SEWER HOUSE
D_PR_SEW_HC 20 Continuous 0.35
CONNECTION

Page 58 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED FOUL SEWER (SEW) (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
PROPOSED SEWER HOUSE
D_PR_SEW_HC_ST_E 20 Continuous 0.35
CONNECTION STUB END CAP
PROPOSED SEWER HOUSE
D_PR_SEW_HC_ST_P 20 HIDDEN2 0.35
CONNECTION STUB END PIPE
PROPOSED SEWER INSPECTION
D_PR_SEW_ICH 20 Continuous 0.35
CHAMBER
PROPOSED SEWER INSPECTION
D_PR_SEW_ICH_ID YELLOW Continuous 0.25
CHAMBER ID
PROPOSED SEWER LAGOON &
D_PR_SEW_LGON 20 Continuous 0.35
TANK
D_PR_SEW_MH 20 Continuous 0.35 PROPOSED SEWER MANHOLE
D_PR_SEW_MH-1 20 Continuous 0.35 PROPOSED SEWER MANHOLE-1
PROPOSED SEWER MICROTUNNEL
D_PR_SEW_MT 20 Continuous 0.35
LINES
PROPOSED SEWER MICROTUNNEL
D_PR_SEW_MTMH 20 Continuous 0.35
MANHOLE
PROPOSED SEWER PUMPING
D_PR_SEW_PS 20 Continuous 0.35
STATION

D_PR_SEW_RM 13 RM_PR 0.60 PROPOSED SEWER RISING MAIN

D_PR_SEW_SPTK RED Continuous 0.10 PROPOSED SEWER SEPTIC TANK

D_PR_SEW_ST_E 20 Continuous 0.35 PROPOSED SEWER STUB END CAP

D_PR_SEW_ST_P 20 DASHED2 0.35 PROPOSED SEWER STUB END PIPE

PROPOSED TUNNELING DRIVE


D_PR_SEW_TDS 20 Continuous 0.35
SHAFT
PROPOSED TUNNELING RECEPTION
D_PR_SEW_TRS 20 Continuous 0.35
SHAFT

Page 59 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED FOUL SEWER (SEW) (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

D_PR_SEW_VALV 20 Continuous 0.35 PROPOSED SEWER VALVE (ALL VALVES)

D_PR_SEW_VC 20 Continuous 0.35 PROPOSED SEWER VALVE CHAMBER

D_PR_SEW_WCH 20 Continuous 0.35 PROPOSED SEWER WASHOUT CHAMBER

D_PR_RIDER_
141 Continuous 0.35 PROPOSED RIDER SEWER
SEWER
D_PR_RIDER_ PROPOSED RIDER SEWER ATTRIBUTES (ID,
YELLOW Continuous 0.35
SEWER_ATT DIAMETER, LENGTH, MATERIAL, ETC.)
D_PR_SEWER 10 Continuous 0.60 PROPOSED SEWER LINE
D_PR_TR_SEWER 10 TRSEW_PR 0.60 PROPOSED TRUNK SEWER

EXISTING FOUL SEWER (SEW)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SEWER ATTRIBUTES (ID,


D_EX_SEWER_ATT WHITE Continuous 0.25
DIAMETER, LENGTH, MATERIAL, ETC.)

D_EX_SEW_AVCH 30 Continuous 0.35 EXISTING SEWER AIRVALVE CHAMBER

EXISTING SEWER DISCHARGE


D_EX_SEW_DCH 30 Continuous 0.35
CHAMBER
D_EX_SEW_DUCT 30 Continuous 0.35 EXISTING SEWER DUCT

D_EX_SEW_FCH 30 Continuous 0.35 EXISTING SEWER FLUSHING CHAMBER

EXISTING SEWER FLOW DIRECTION


D_EX_SEW_FLOW WHITE Continuous 0.25
ARROW

D_EX_SEW_HC 30 HIDDEN2 0.35 EXISTING SEWER HOUSE CONNECTION

Page 60 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING FOUL SEWER (SEW) (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

D_EX_SEW_HC_ EXISTING SEWER HOUSE CONNECTION


30 Continuous 0.35
ST_E STUB END CAP
D_EX_SEW_HC_ EXISTING SEWER HOUSE CONNECTION
30 HIDDEN2 0.35
ST_P STUB END PIPE
EXISTING SEWER INSPECTION
D_EX_SEW_ICH 30 Continuous 0.35
CHAMBER
EXISTING SEWER INSPECTION
D_EX_SEW_ICH_ID WHITE Continuous 0.25
CHAMBER ID
D_EX_SEW_LGON 30 Continuous 0.35 EXISTING SEWER LAGOON & TANK
D_EX_SEW_MH 30 Continuous 0.35 EXISTING SEWER MANHOLE
D_EX_SEW_MH-1 30 Continuous 0.35 EXISTING SEWER MANHOLE-1
D_EX_SEW_MT 30 Continuous 0.35 EXISTING SEWER MICROTUNNEL
EXISTING SEWER MICROTUNNEL
D_EX_SEW_MTMH 30 Continuous 0.35
MANHOLE

D_EX_SEW_PS 30 Continuous 0.35 EXISTING SEWER PUMPING STATION

D_EX_SEW_RM 170 RM_EX 0.35 EXISTING SEWER RISING MAIN


D_EX_SEW_SPTK 30 Continuous 0.35 EXISTING SEWER SEPTIC TANK
D_EX_SEW_ST_E 30 Continuous 0.35 EXISTING SEWER STUB END CAP
D_EX_SEW_ST_P 30 DASHED2 0.35 EXISTING SEWER STUB END PIPE
D_EX_SEW_TDS 30 Continuous 0.35 EXISTING TUNNELING DRIVE SHAFT
EXISTING TUNNELING RECEPTION
D_EX_SEW_TRS 30 Continuous 0.35
SHAFT
D_EX_SEW_VALV 30 Continuous 0.35 EXISTING SEWER VALVE
D_EX_SEW_VC 30 Continuous 0.35 EXISTING SEWER VALVE CHAMBER
D_EX_SEW_WCH 30 Continuous 0.35 EXISTING SEWER WASHOUT CHAMBER
D_EX_RIDER_SEWER 161 Continuous 0.35 EXISTING RIDER SEWER

Page 61 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING FOUL SEWER (SEW) (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

D_EX_RIDER_ EXISTING RIDER SEWER ATTRIBUTES (ID,


WHITE Continuous 0.35
SEWER_ATT DIAMETER, LENGTH, MATERIAL, ETC.)
D_EX_SEWER 30 DASHED2 0.35 EXISTING SEWER LINE
D_EX_TR_SEWER 30 TRSEW_EX 0.35 EXISTING TRUNK SEWER

A.3.3 Treated Sewage Effluent (TSE)

PROPOSED TREATED SEWAGE EFFLUENT (TSE)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED TREATED SEWAGE


D_PR_TSE 210 TSE_PR 0.35
EFFLUENT LINES
PROPOSED TSE ATTRIBUTES (ID,
D_PR_TSE_ATT YELLOW Continuous 0.25
DIAMETER, LENGTH, MATERIAL,
PROPOSED
ETC.) TSE AIR VALVE
D_PR_TSE_AVCH 200 Continuous 0.35
CHAMBER
D_PR_TSE_BY_OTHERS 160 TSE_PR 0.35 PROPOSED TSE BY OTHERS

D_PR_TSE_DAMW 200 Continuous 0.35 PROPOSED TSE DAM WALL

PROPOSED TSE DISCHARGE


D_PR_TSE_DCH 200 Continuous 0.35
CHAMBER
PROPOSED TSE DISTRIBUTION
D_PR_TSE_DICH 200 Continuous 0.35
CHAMBER
D_PR_TSE_DUCT 30 Continuous 0.35 PROPOSED TSE DUCT

PROPOSED TSE FLUSHING


D_PR_TSE_FCH 200 Continuous 0.35
CHAMBER
D_PR_TSE_FIHD 200 Continuous 0.35 PROPOSED FIRE HYDRANT

Page 62 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TREATED SEWAGE EFFLUENT (TSE) (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED TSE FLOW DIRECTION


D_PR_TSE_FLOW WHITE Continuous 0.25
ARROW
PROPOSED TSE FLOW METER
D_PR_TSE_FMCH 200 Continuous 0.35
CHAMBER
PROPOSED TSE INSPECTION
D_PR_TSE_ICH 200 Continuous 0.35
CHAMBER
D_PR_TSE_LGON 200 Continuous 0.35 PROPOSED TSE LAGOON & TANKS
D_PR_TSE_MH 200 Continuous 0.35 PROPOSED TSE MANHOLE
PROPOSED TSE DAM WALL PILLER
D_PR_TSE_PILR 200 Continuous 0.35
OR BEND
D_PR_TSE_PS 200 Continuous 0.35 PROPOSED TSE PUMPING STATION
D_PR_TSE_ST_E 200 Continuous 0.35 PROPOSED TSE STUB END CAP
D_PR_TSE_ST_P 200 Continuous 0.35 PROPOSED TSE STUB END PIPE
PROPOSED SEWAGE TREATMENT
D_PR_TSE_STWK 200 Continuous 0.35
WORKS / TREATMENT PLANT
D_PR_TSE_VALV 200 Continuous 0.35 PROPOSED TSE VALVE
D_PR_TSE_VC 200 Continuous 0.35 PROPOSED TSE VALVE CHAMBER
PROPOSED TSE WASHOUT
D_PR_TSE_WCH 200 Continuous 0.35
CHAMBER
D_PR_TSE_WTWR 200 Continuous 0.35 PROPOSED TSE WATER TOWER

Page 63 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TREATED SEWAGE EFFLUENT (TSE)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING TREATED SEWAGE


D_EX_TSE 240 TSE_EX 0.35
EFFLUENT LINES
EXISTING TSE ATTRIBUTES (ID,
D_EX_TSE_ATT WHITE Continuous 0.25 DIAMETER, LENGTH, MATERIAL,
ETC.)
D_EX_TSE_AVCH 240 Continuous 0.35 EXISTING TSE AIR VALVE CHAMBER
D_EX_TSE_DAMW 240 Continuous 0.35 EXISTING TSE DAM WALL
EXISTING TSE DISCHARGE
D_EX_TSE_DCH 240 Continuous 0.35
CHAMBER
EXISTING TSE DISTRIBUTION
D_EX_TSE_DICH 240 Continuous 0.35
CHAMBER

D_EX_TSE_DUCT 30 Continuous 0.35 EXISTING TSE DUCT

D_EX_TSE_FCH 240 Continuous 0.35 EXISTING TSE FLUSHING CHAMBER

D_EX_TSE_FIHD 240 Continuous 0.35 EXISTING FIRE HYDRANT

EXISTING TSE FLOW DIRECTION


D_EX_TSE_FLOW WHITE Continuous 0.25
ARROW
EXISTING TSE FLOW METER
D_EX_TSE_FMCH 240 Continuous 0.35
CHAMBER
EXISTING TSE INSPECTION
D_EX_TSE_ICH 240 Continuous 0.35
CHAMBER

D_EX_TSE_LGON 240 Continuous 0.35 EXISTING TSE LAGOON & TANKS

D_EX_TSE_MH 240 Continuous 0.35 EXISTING TSE MANHOLE

EXISTING TSE DAM WALL PILLER OR


D_EX_TSE_PILR 240 Continuous 0.35
BEND

Page 64 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TREATED SEWAGE EFFLUENT (TSE) (Continuation...)


Plotted
Layer Name Screen Colour Linetype Description
Line weight

D_EX_TSE_PS 240 Continuous 0.35 EXISTING TSE PUMPING STATION


D_EX_TSE_ST_E 240 Continuous 0.35 EXISTING TSE STUB END CAP
D_EX_TSE_ST_P 240 DASHED2 0.35 EXISTING TSE STUB END PIPE
EXISTING SEWAGE TREATMENT
D_EX_TSE_STWK 240 Continuous 0.35
WORKS / TREATMENT PLANT
D_EX_TSE_VALV 240 Continuous 0.35 EXISTING TSE VALVE

D_EX_TSE_VC 240 Continuous 0.35 EXISTING TSE VALVE CHAMBER

D_EX_TSE_WCH 240 Continuous 0.35 EXISTING TSE WASHOUT CHAMBER

D_EX_TSE_WTWR 240 Continuous 0.35 EXISTING TSE WATER TOWER

A.3.4 General Construction Layers

GENERAL CONSTRUCTION LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

D_C_10HID RED HIDDEN2 0.10 HIDDEN DETAILS

D_C_10OUT RED Continuous 0.10 ALL VERY THIN OUTLINES


D_C_10PIPE RED Continuous 0.10 PIPE WORK OUTLINES / FITTINGS

D_C_10PIPEHID RED HIDDEN2 0.10 PIPE WORK HIDDEN LINES


D_C_25DASH WHITE DASHED2 0.25 HIDDEN DETAILS

D_C_25HID WHITE HIDDEN2 0.25 HIDDEN DETAILS

D_C_25OUT YELLOW Continuous 0.25 ALL THIN OUTLINES


ALL OUT LINES IN PLAN /
D_C_35OUT GREEN Continuous 0.35
ELEVATION
ALL CONCRETE OUTLINES IN
D_C_50OUT CYAN Continuous 0.50
SECTION

Page 65 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

GENERAL CONSTRUCTION LAYERS (Continuation...)


Screen Plotted Line
Layer Name Linetype Description
Colour weight

D_C_50REBARS CYAN Continuous 0.50 REINFORCEMENT DETAILS

ALL CONCRETE OUTLINES IN


D_C_70OUT BLUE Continuous 0.70
SECTION

D_C_BUND YELLOW Continuous 0.25 BUND OUTLINES


D_C_CHAIN WHITE Continuous 0.25 CHAINAGE SYMBOL

D_C_CHAIN-TEXT WHITE Continuous 0.25 CHAINAGE TEXT


D_C_CTRLINE RED CENTER2 0.10 CENTRE LINE
D_C_EX_GRND WHITE DASHED2 0.25 EXISTING GROUND LEVEL

D_C_FRL WHITE DASHED2 0.25 FINISHED ROAD LEVEL


D_C_HATCH RED Continuous 0.10 ALL HATCHING

D_C_PROF_CURV CYAN Continuous 0.50 PROFILE: VERTICAL CURVES


D_C_PROF_DIAG CYAN Continuous 0.50 PROFILE: BAND DIAGRAMS

D_C_PROF_FG YELLOW HIDDEN2 0.25 PROFILE: FINISHED GROUND

PROFILE: GRIDLINE @ MAJOR


D_C_PROF_GRID-MAJR 251 Continuous 0.15
STATIONS
PROFILE: GRIDLINE @ MINOR
D_C_PROF_GRID-MINR 251 Continuous 0.15
STATIONS
D_C_PROF_LABL 8 Continuous 0.20 PROFILE: LABEL
D_C_PROF_LINE RED Continuous 0.10 PROFILE: VERTICAL LINES

D_C_PROF_MATCHLINE BLUE PHANTOM2 0.70 PROFILE: MATCHLINE

D_C_PROF_SEW CYAN Continuous 0.50 PROFILE: SEW PROFILE LINE

D_C_PROF_SGW CYAN Continuous 0.50 PROFILE: SGW PROFILE LINE

D_C_PROF_STAN- PROFILE: GEOMETRY POINT


WHITE Continuous 0.25
GEOM LABELS
PROFILE: MAJOR STATION
D_C_PROF_STAN-MAJR YELLOW Continuous 0.25
LABELS

Page 66 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

GENERAL CONSTRUCTION LAYERS (Continuation...)


Screen Plotted Line
Layer Name Linetype Description
Colour weight
D_C_PROF_STAN-MINR RED Continuous 0.10 PROFILE: MINOR STATION LABELS
D_C_PROF_TEXT WHITE Continuous 0.25 PROFILE: TEXT
D_C_PROF_TICK 251 Continuous 0.15 PROFILE: TICK MARKS
D_C_PROF_TITL CYAN Continuous 0.50 PROFILE: LABEL / TITLE
D_C_PROF_TSE CYAN Continuous 0.50 PROFILE: TSE PROFILE LINE
D_C_TABLE WHITE Continuous 0.25 TABLES
D_C_TEXT WHITE Continuous 0.25 GENERAL / COMMON TEXT

A.3.5 Attribute & Common Layers

(DRAINAGE) ATTRIBUTE & COMMON LAYERS


Screen Plotted Line
Layer Name Linetype Description
Colour weight

D_EX_ABD_SEW 30 ---A--- 0.35 ABANDONED SEWER LINES


ABANDONED SURFACE GROUND WATER
D_EX_ABD_SGW 30 ---A--- 0.35
LINES
D_EX_ABD_TSE 30 ---A--- 0.35 ABANDONED TSE LINES

EXISTING AIRVALVE CHAMBER


D_EX_AVCH_ATT WHITE Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL, INV.
LVL, ETC.)
D_EX_BOREHOLE WHITE Continuous 0.25 EXISTING BOREHOLE

D_EX_BOREHOLE_ EXISTING BOREHOLE ATTRIBUTES (ID,


WHITE Continuous 0.25
ATT DEPTH, COV. LVL, INV. LVL, ETC.)
EXISTING DISCHARGE CHAMBER
D_EX_DC_ATT WHITE Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL, INV.
LVL, ETC.)

Page 67 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

(DRAINAGE) ATTRIBUTE & COMMON LAYERS (CONTINUATION...)


Screen Plotted Line
Layer Name Linetype Description
Colour weight

EXISTING INCOMING DISCHARGE


D_EX_DC_RM_DIA WHITE Continuous 0.25
CHAMBER RISING MAIN DIAMETER

EXISTING DISCHARGE CHAMBER


D_EX_DC_SEW_DIA WHITE Continuous 0.25
OUTGOING SEWER DIAMETER

EXISTING DISCHARGE CHAMBER


D_EX_DC_SGW_DIA WHITE Continuous 0.25
OUTGOING SGW PIPE DIAMETER

EXISTING DISCHARGE CHAMBER


D_EX_DC_TSE_DIA WHITE Continuous 0.25
OUTGOING TSE PIPE DIAMETER
EXISTING FLOWMETER RISING
D_EX_FM_RM_DIA WHITE Continuous 0.25
MAIN DIAMETER

D_EX_FMCH 30 Continuous 0.35 EXISTING FLOWMETER CHAMBER

EXISTING FLOWMETER CHAMBER


D_EX_FMCH_ATT WHITE Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, TYPE, ETC.)
EXISTING GULLY CONNECTION
ATTRIBUTES (ID, DIAMETER,
D_EX_GC_ATT WHITE Continuous 0.25
LENGTH, MATERIAL, DEPTH, COV.
LVL, INV. LVL, ETC.)
EXISTING GULLY ATTRIBUTES (ID,
D_EX_GL_ATT WHITE Continuous 0.25
COV. LVL, INV. LVL, ETC)

EXISTING HOUSECONNECTION
ATTRIBUTES (ID, DIAMETER,
D_EX_HC_ATT WHITE Continuous 0.25
LENGTH, MATERIAL, DEPTH, COV.
LVL, INV. LVL, TYPE, ETC.)

Page 68 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

(DRAINAGE) ATTRIBUTE & COMMON LAYERS (CONTINUATION...)


Screen Plotted Line
Layer Name Linetype Description
Colour weight
EXISTING MANHOLE-1 ATTRIBUTES (ID,
D_EX_MH-1_ATT WHITE Continuous 0.25
DEPTH, COV. LVL, INV. LVL, ETC.)
EXISTING MANHOLE ATTRIBUTES (ID,
D_EX_MH_ATT WHITE Continuous 0.25 DEPTH, COV. LVL, INV. LVL, TYPE,
RODDING EYE LVL, ETC.)
EXISTING MICROTUNNEL ATTRIBUTES (ID,
D_EX_MT_ATT WHITE Continuous 0.25
DIAMETER, LENGTH, MATERIAL, ETC. )
EXISTING MICROTUNNEL MANHOLE
D_EX_MTMH_ATT WHITE Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL, INV.
LVL, TYPE, RODDING EYE LVL, ETC.)
EXISTING OUTFALL CHAMBER
D_EX_OFCH_ATT WHITE Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL, INV.
LVL, TYPE, ETC.)
D_EX_PENSTOCK 21 Continuous 0.35 EXISTING PENSTOCK
EXISTING PUMPING STATION ATTRIBUTES
D_EX_PS_ATT WHITE Continuous 0.25 (ID, DEPTH, COV. LVL, INV. LVL, PUMP
CAPACITY, TOTAL HEAD, ETC.)
EXISTING PUMPING STATION SCADA
D_EX_PS_SCADA WHITE Continuous 0.25
SYSTEM
EXISTING P/S INCOMING SEWER
ATTRIBUTES (ID, DIAMETER, LENGTH,
D_EX_PS_SEW_ATT WHITE Continuous 0.25
MATERIAL, DEPTH, COV. LVL, INV. LVL,
ETC.)
EXISTING P/S INCOMING SGW
D_EX_PS_SGW_ ATTRIBUTES (ID, DIAMETER, LENGTH,
WHITE Continuous 0.25
ATT MATERIAL, DEPTH, COV. LVL, INV. LVL,
ETC )

Page 69 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

(DRAINAGE) ATTRIBUTE & COMMON LAYERS (CONTINUATION...)


Screen Plotted Line
Layer Name Linetype Description
Colour weight

EXISTING P/S INCOMING TSE


ATTRIBUTES (ID, DIAMETER, LENGTH,
D_EX_PS_TSE_ATT WHITE Continuous 0.25
MATERIAL, DEPTH, COV. LVL, INV.
LVL, ETC.)
EXISTING REFUR/REFINED/REPLACED
D_EX_RE_SEW 30 ---R--- 0.35
SEWER LINES
EXISTING REFUR/REFINED/REPLACED
D_EX_RE_SGW 30 ---R--- 0.35
SURFACE GROUND WATER LINES
EXISTING REFUR/REFINED/REPLACED
D_EX_RE_TSE 30 ---R--- 0.35
TSE LINES
EXISTING RISING MAIN ATTRIBUTES
D_EX_RM_ATT WHITE Continuous 0.25 (ID, DIAMETER, LENGTH, MATERIAL
ETC.)
D_EX_RM_MH 170 Continuous 0.35 EXISTING RISING MAIN MANHOLE
EXISITING RISING MAIN PUMP
D_EX_RM_PS 240 Continuous 0.35
STATION
D_EX_SCR-CHMBR MAGENTA Continuous 0.35 EXISTING SCREEN CHAMBER
EXISTING SEWERAGE TREATMENT
D_EX_STW 240 DASHED2 0.35
WORKS
EXISTING SEWERAGE TREATMENT
D_EX_STW_TANKS CYAN Continuous 0.50
WORK TANKS
EXISTING SURGE VESSEL CHAMBER
D_EX_SV_ATT WHITE Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, TYPE, CAPACITY, ETC.)
EXISTING SURGE VESSEL RISING
D_EX_SV_RM_DIA WHITE Continuous 0.25
MAIN DIAMETER

Page 70 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

(DRAINAGE) ATTRIBUTE & COMMON LAYERS (CONTINUATION...)


Screen Plotted Line
Layer Name Linetype Description
Colour weight
D_EX_SVCH 40 Continuous 0.35 EXISTING SURGE VESSEL CHAMBER
EXISTING VALVE ATTRIBUTES (ID,
D_EX_VALV_ATT WHITE Continuous 0.25
DEPTH, COV. LVL, INV. LVL, ETC.)
EXISTING VALVE CHAMBER
D_EX_VC_ATT WHITE Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, TYPE, CAPACITY, ETC.)
EXISTING VALVE RISING MAIN
D_EX_VC_RM_DIA WHITE Continuous 0.25
DIAMETER
EXISTING WASHOUT CHAMBER
D_EX_WO_ATT WHITE Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, ETC.)
EXISTING WASHOUT CHAMBER RISING
D_EX_WO_RM_DIA WHITE Continuous 0.25
MAIN DIAMETER
D_EX_WO_SUMP 140 Continuous 0.25 EXISTING WASHOUT SUMP/MH
PROPOSED AIRVALVE CHAMBER
D_PR_AVCH_ATT YELLOW Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, ETC.)
D_PR_BOREHOLE 220 Continuous 0.35 PROPOSED BOREHOLE
D_PR_BOREHOLE_ PROPOSED BOREHOLE ATTRIBUTES (ID,
YELLOW Continuous 0.25
ATT DEPTH, COV. LVL, INV. LVL, ETC.)
PROPOSED DISCHARGE CHAMBER
D_PR_DC_ATT YELLOW Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, ETC.)
PROPOSED INCOMING RISING MAIN
D_PR_DC_RM_DIA YELLOW Continuous 0.25
DIAMETER

Page 71 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

(DRAINAGE) ATTRIBUTE & COMMON LAYERS (CONTINUATION...)


Screen Plotted Line
Layer Name Linetype Description
Colour weight
PROPOSED DISCHARGE CHAMBER
D_PR_DC_SEW_DIA YELLOW Continuous 0.25
OUTGOING SEWER DIAMETER
PROPOSED DISCHARGE CHAMBER
D_PR_DC_SGW_DIA YELLOW Continuous 0.25
OUTGOING SGW DIAMETER
PROPOSED DISCHARGE CHAMBER
D_PR_DC_TSE_DIA YELLOW Continuous 0.25
OUTGOING TSE DIAMETER
PROPOSED FLOWMETER RISING
D_PR_FM_RM_DIA YELLOW Continuous 0.25
MAIN DIAMETER

D_PR_FMCH 30 Continuous 0.35 PROPOSED FLOWMETER CHAMBER

PROPOSED FLOWMETER CHAMBER


D_PR_FMCH_ATT YELLOW Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, TYPE, ETC.)
PROPOSED GULLY CONNECTION
ATTRIBUTES (ID, DIAMETER,
D_PR_GC_ATT YELLOW Continuous 0.25
LENGTH, MATERIAL, DEPTH, COV.
LVL, INV. LVL, ETC.)
PROPOSED GULLY ATTRIBUTES (ID,
D_PR_GL_ATT YELLOW Continuous 0.25
COV. LVL, INV. LVL, ETC.)
PROPOSED HOUSECONNECTION
ATTRIBUTES (ID, DIAMETER,
D_PR_HC_ATT YELLOW Continuous 0.25
LENGTH, MATERIAL, DEPTH, COV.
LVL, INV. LVL, ETC.)
PROPOSED MANHOLE-1 ATTRIBUTES
D_PR_MH-1_ATT YELLOW Continuous 0.25 (ID, DEPTH, COV. LVL, INV. LVL,
ETC.)

Page 72 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

(DRAINAGE) ATTRIBUTE & COMMON LAYERS (CONTINUATION...)


Plotted
Screen
Layer Name Linetype Line Description
Colour
weight
PROPOSED MANHOLE ATTRIBUTES (ID,
D_PR_MH_ATT YELLOW Continuous 0.25 DEPTH, COV. LVL, INV. LVL, TYPE, RODDING
EYE LVL, ETC.)
PROPOSED MICROTUNNEL ATTRIBUTES (ID,
D_PR_MT_ATT YELLOW Continuous 0.25
DIAMETER, LENGTH, MATERIAL, ETC. )
PROPOSED MICROTUNNEL MANHOLE
D_PR_MTMH_
YELLOW Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL, INV. LVL,
ATT
TYPE, RODDING EYE LVL, ETC.)
PROPOSED OUTFALL CHAMBER ATTRIBUTES
D_PR_OFCH_ ATT YELLOW Continuous 0.25
(ID, DEPTH, COV. LVL, INV. LVL, TYPE, ETC.)
D_PR_PENSTOCK 21 Continuous 0.35 PROPOSED PENSTOCK
PROPOSED PUMPING STATION ATTRIBUTES
D_PR_PS_ATT YELLOW Continuous 0.25 (ID, DEPTH, COV. LVL, INV. LVL, PUMP
CAPACITY, TOTAL HEAD, ETC.)
PROPOSED PUMPING STATION SCADA
D_PR_PS_ SCADA YELLOW Continuous 0.25
SYSTEM
PROPOSED P/S INCOMING SEWER
D_PR_PS_SEW_ ATTRIBUTES (ID, DIAMETER, LENGTH,
YELLOW Continuous 0.25
ATT MATERIAL, DEPTH, COV. LVL, INV. LVL,
ETC.)
PROPOSED P/S INCOMING SGW ATTRIBUTES
D_PR_PS_SGW_
YELLOW Continuous 0.25 (ID, DIAMETER, LENGTH, MATERIAL, DEPTH,
ATT
COV. LVL, INV. LVL, ETC.)
PROPOSED P/S INCOMING TSE ATTRIBUTES
D_PR_PS_TSE_
YELLOW Continuous 0.25 (ID, DIAMETER, LENGTH, MATERIAL, DEPTH,
ATT
COV. LVL, INV. LVL, ETC.)

Page 73 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

(DRAINAGE) ATTRIBUTE & COMMON LAYERS (CONTINUATION...)


Screen Plotted Line
Layer Name Linetype Description
Colour weight
PROPOSED RISING MAIN ATTRIBUTES
D_PR_RM_ATT YELLOW Continuous 0.25
(ID, DIAMETER, LENGTH, ETC.)
D_PR_RM_MH 170 Continuous 0.35 PROPOSED RISING MAIN MANHOLE
PROPOSED RISING MAIN PUMP
D_PR_RM_PS 240 Continuous 0.35
STATION
D_PR_SCR-CHMBR 32 Continuous 0.25 PROPOSED SCREEN CHAMBER
PROPOSED SEWERAGE TREATMENT
D_PR_STW 240 Continuous 0.35
WORKS
PROPOSED SURGE VESSEL CHAMBER
D_PR_SV_ATT YELLOW Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, TYPE, CAPACITY, ETC.)
PROPOSED SURGE VESSEL RISING
D_PR_SV_RM_DIA YELLOW Continuous 0.25
MAIN DIAMETER
D_PR_SVCH 40 Continuous 0.35 PROPOSED SURGE VESSEL CHAMBER

PROPOSED VALVE ATTRIBUTES (ID,


D_PR_VALV_ATT YELLOW Continuous 0.25
DEPTH, COV. LVL, INV. LVL, ETC.)

PROPOSED VALVE CHAMBER


D_PR_VC_ATT YELLOW Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, TYPE, CAPACITY, ETC.)
PROPOSED VALVE RISING MAIN
D_PR_VC_RM_DIA YELLOW Continuous 0.25
DIAMETER
PROPOSED WASHOUT CHAMBER
D_PR_WO_ATT YELLOW Continuous 0.25 ATTRIBUTES (ID, DEPTH, COV. LVL,
INV. LVL, ETC.)
PROPOSED WASHOUT CHAMBER
D_PR_WO_RM_DIA YELLOW Continuous 0.25
RISING MAIN DIAMETER
D_PR_WO_SUMP GREEN Continuous 0.35 PROPOSED WASHOUT SUMP/MH

Page 74 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

A.4 ROAD LAYERS

A.4.1 Road Design Layers

PROPOSED ROAD DESIGN LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED ROAD FEATURE :


RD_PR_ACRS 22 Continuous 0.35
ANIMAL CROSSING
PROPOSED ROAD FEATURE:
RD_PR_AFNCE 22 FENCELINE15 0.35
ANIMAL FENCE
PROPOSED ROAD FEATURE :
RD_PR_AGRID 22 Continuous 0.35
ANIMAL GRID
PROPOSED ROAD FEATURE :
RD_PR_APED WHITE Continuous 0.25
ASPHALT EDGE
RD_PR_APPROACH- PROPOSED ROAD FEATURE :
220 Continuous 0.35
SPLAY JUNCTION APPROACH SPLAY
PROPOSED ROAD FEATURE :
RD_PR_AWAY WHITE Continuous 0.25
ACCESS WAY
PROPOSED ROAD FEATURE :
RD_PR_BICYL GREEN Continuous 0.35
BICYCLE LANE
PROPOSED ROAD FEATURE :
RD_PR_BRDG YELLOW Continuous 0.25
BRIDGE FLYOVER
PROPOSED ROAD FEATURE :
RD_PR_BRHL RED Continuous 0.10
BOREHOLE
PROPOSED ROAD FEATURE :
RD_PR_CHNL RED HIDDEN2 0.10
CHANNEL
PROPOSED ROAD FEATURE :
RD_PR_CILND GREEN Continuous 0.35 CENTRAL/ROUNDABOUT
ISLAND
PROPOSED ROAD FEATURE :
RD_PR_CLMN RED Continuous 0.10
COLUMN

Page 75 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED ROAD DESIGN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED ROAD FEATURE :


RD_PR_CLVT WHITE Continuous 0.25
CULVERT

PROPOSED ROAD FEATURE :


RD_PR_CNRL RED CENTER2 0.10
CENTERLINE

PROPOSED ROAD FEATURE :


RD_PR_CSLPE MAGENTA Continuous 0.35
CONCRETE SLOPE PROTECTION

PROPOSED ROAD FEATURE :


RD_PR_CWAY CYAN Continuous 0.50
CARRIAGEWAY

RD_PR_FNCE GREEN FENCELINE25 0.35 PROPOSED ROAD FEATURE : FENCE

PROPOSED ROAD FEATURE :


RD_PR_FTPH 11 Continuous 0.35
FOOTPATH
PROPOSED ROAD FEATURE :
RD_PR_FUT-
30 Continuous 0.35 RESERVED FOR FUTURE
CDITCH
CONTAINMENT DITCH
PROPOSED ROAD FEATURE :
RD_PR_FUT-LANE 20 Continuous 0.35
RESERVED FOR FUTURE

RD_PR_GEOM YELLOW Continuous 0.25 GEOMETRY STRING

RD_PR_GIVE-WAY- PROPOSED ROAD FEATURE :


111 Continuous 0.35
SPLAY JUNCTION GIVE-WAY SPLAY
PROPOSED ROAD FEATURE : GATE
RD_PR_GLVL WHITE Continuous 0.25
LEVEL
PROPOSED ROAD FEATURE :
RD_PR_GRAIL WHITE GUARDRAIL 0.25
GUARD RAIL

PROPOSED ROAD FEATURE : HARD


RD_PR_HSTRIP WHITE Continuous 0.25
STRIP

Page 76 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED ROAD DESIGN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED ROAD FEATURE :


RD_PR_ILOCK RED Continuous 0.10
INTER LOCK
RD_PR_INTER- PROPOSED ROAD FEATURE :
254 Continuous 0.15
VISIBILITY-ZONE JUNCTION INTERVISIBILITY SPLAY
PROPOSED ROAD FEATURE :
RD_PR_JILND GREEN Continuous 0.35
JUNCTION ISLAND
PROPOSED ROAD FEATURE :
RD_PR_KBDD GREEN HIDDEN2 0.35
DROPPED KERB
PROPOSED ROAD FEATURE :
RD_PR_KBED 150 Continuous 0.25
EDGE KERB
PROPOSED ROAD FEATURE :
RD_PR_KBFL YELLOW DASHED2 0.25
FLUSH KERB
PROPOSED ROAD FEATURE :
RD_PR_KBRD CYAN Continuous 0.50
RAISED KERB

RD_PR_LOW BLUE DASHDOT2 0.70 LIMIT OF WORKS

PROPOSED ROAD FEATURE :


RD_PR_MBK YELLOW Continuous 0.25
EMBANKMENT
PROPOSED ROAD FEATURE :
RD_PR_MEDIAN GREEN Continuous 0.35
MEDIAN
PROPOSED ROAD FEATURE :
RD_PR_OTHR RED Continuous 0.10
OTHER INFORMATION
PROPOSED ROAD FEATURE :
RD_PR_PBAY GREEN Continuous 0.35
PARKING BAY
PROPOSED ROAD FEATURE :
RD_PR_PDCR 8 Continuous 0.20
PEDESTRIAN CROSSING
PROPOSED ROAD FEATURE :
RD_PR_PRAMP GREEN Continuous 0.35
PEDESTRIAN RAMP

Page 77 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED ROAD DESIGN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED ROAD FEATURE :


RD_PR_PRKG WHITE Continuous 0.25
PARKING
PROPOSED ROAD FEATURE :
RD_PR_PTS YELLOW Continuous 0.25
IPS, CURVE POINTS ETC.,
PROPOSED ROAD FEATURE
REPRESENTATION: PAVEMENT
RD_PR_PVMT WHITE Continuous 0.25
(ASPHALT, BITMAC,
CONCRETE ETC.)
PROPOSED ROAD FEATURE :
RD_PR_RAILCOR 252 HIDDEN2 0.15
RAIL CORRIDOR
PROPOSED ROAD FEATURE :
RD_PR_RAILWAY WHITE TRACKS2 0.25
RAILWAY
PROPOSED ROAD FEATURE :
RD_PR_RAMP YELLOW Continuous 0.25
RAMP
PROPOSED ROAD FEATURE :
RD_PR_RBTR 8 Continuous 0.20
ROAD BATTER
PROPOSED ROAD FEATURE :
RD_PR_REDG WHITE Continuous 0.25
ROAD EDGE
PROPOSED ROAD FEATURE :
RD_PR_RLVL WHITE Continuous 0.25
ROAD LEVEL
PROPOSED ROAD FEATURE :
RD_PR_RNDA WHITE Continuous 0.25
ROUND ABOUT
PROPOSED ROAD FEATURE :
RD_PR_RRAP 8 Continuous 0.20
RIPRAP
PROPOSED ROAD FEATURE :
RD_PR_RSLAB RED Continuous 0.10
ROAD SLAB
PROPOSED ROAD FEATURE :
RD_PR_RSTL WHITE Continuous 0.25
ROAD SPEED TABLE

Page 78 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED ROAD DESIGN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED ROAD FEATURE :


RD_PR_SBAR-END 172 END_TERMINAL 0.35
SAFETY BARRIER END
PROPOSED
TERMINAL ROAD FEATURE :
RD_PR_SBAR-TERM 104 TERMINAL 0.35
SAFETY BARRIER TERMINAL
PROPOSED ROAD FEATURE :
RD_PR_SDITCH 44 Continuous 0.35
SWALE DITCH
PROPOSED ROAD FEATURE :
RD_PR_SHLDR GREEN Continuous 0.35
SHOULDER
PROPOSED ROAD FEATURE :
RD_PR_SP-KBCLER 170 Continuous 0.35
SWEPT PATH KERB
PROPOSED
CLEARANCEROAD FEATURE :
RD_PR_SP-PATH RED Continuous 0.10
VEHICLE SWEPT PATH
PROPOSED ROAD FEATURE :
RD_PR_SPTR 20 Continuous 0.35
ROAD SEPARATOR
PROPOSED ROAD FEATURE :
RD_PR_STAIRS YELLOW Continuous 0.25
STAIRS
PROPOSED ROAD FEATURE :
RD_PR_SWAY 190 Continuous 0.35
PEDESTRIAN SUBWAY
PROPOSED ROAD FEATURE :
RD_PR_TPIT RED Continuous 0.10
TRIAL PIT
PROPOSED ROAD FEATURE :
RD_PR_UPSS YELLOW Continuous 0.25
UNDERPASS TUNNEL
PROPOSED ROAD FEATURE :
RD_PR_VBAR MAGENTA Continuous 0.35
VEHICLE BARRIER
PROPOSED ROAD FEATURE :
RD_PR_VERGE YELLOW Continuous 0.25
VERGE

Page 79 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED ROAD DESIGN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED ROAD FEATURE :


RD_PR_VISIBILITY-
100 Continuous 0.35 STOPPING SIGHT DISTANCE
SPLAY
SPLAY
PROPOSED ROAD FEATURE :
RD_PR_WALL 40 Continuous 0.35
ALL WALLS

EXISTING ROAD DESIGN LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING ROAD FEATURE :


RD_EX_ACRS 31 Continuous 0.35
ANIMAL CROSSING
EXISTING ROAD FEATURE:
RD_EX_AFNCE 31 FENCELINE15 0.35
ANIMAL FENCE
EXISTING ROAD FEATURE :
RD_EX_AGRID 31 Continuous 0.35
ANIMAL GRID
EXISTING ROAD FEATURE :
RD_EX_APED WHITE Continuous 0.25
ASPHALT EDGE
EXISTING ROAD FEATURE:
RD_EX_AWAY WHITE Continuous 0.25
ACCESS WAY
EXISTING ROAD FEATURE:
RD_EX_BICYL GREEN Continuous 0.35
BICYCLE LANE
EXISTING ROAD FEATURE:
RD_EX_BRDG YELLOW Continuous 0.25
BRIDGE FLYOVER
EXISTING ROAD FEATURE :
RD_EX_BRHL WHITE Continuous 0.25
BOREHOLE

Page 80 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING ROAD DESIGN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING ROAD FEATURE :


RD_EX_CHNL RED HIDDEN2 0.10
CHANNEL
EXISTING ROAD FEATURE :
RD_EX_CILND GREEN Continuous 0.35
CENTRAL/ROUNDABOUT
EXISTING
ISLAND ROAD FEATURE :
RD_EX_CLMN RED Continuous 0.10
COLUMN
EXISTING ROAD FEATURE :
RD_EX_CLVT WHITE Continuous 0.25
CULVERT
EXISTING ROAD FEATURE :
RD_EX_CNRL RED CENTER2 0.10
CENTERLINE
EXISTING ROAD FEATURE :
RD_EX_CSLPE MAGENTA Continuous 0.35
CONCRETE SLOPE PROTECTION
EXISTING ROAD FEATURE :
RD_EX_CWAY CYAN Continuous 0.50
CARRIAGEWAY
EXISTING ROAD FEATURE :
RD_EX_FNCE GREEN FENCELINE25 0.35
FENCE
EXISTING ROAD FEATURE :
RD_EX_FTPH 11 Continuous 0.35
FOOTPATH
EXISTING ROAD FEATURE :
RD_EX_GLVL WHITE Continuous 0.25
GATE LEVEL
EXISTING ROAD FEATURE :
RD_EX_GRAIL WHITE GUARDRAIL 0.25
GUARD RAIL
EXISTING ROAD FEATURE :
RD_EX_HSTRIP WHITE Continuous 0.25
HARD STRIP
EXISTING ROAD FEATURE :
RD_EX_ILOCK RED Continuous 0.10
INTER LOCK
EXISTING ROAD FEATURE :
RD_EX_JILND GREEN Continuous 0.35
JUNCTION ISLAND

Page 81 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING ROAD DESIGN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING ROAD FEATURE :


RD_EX_KBDD GREEN HIDDEN2 0.35
DROPPED KERB
EXISTING ROAD FEATURE :
RD_EX_KBED 150 Continuous 0.25
EDGE KERB
EXISTING ROAD FEATURE :
RD_EX_KBFL YELLOW DASHED2 0.25
FLUSH KERB
EXISTING ROAD FEATURE :
RD_EX_KBRD CYAN Continuous 0.50
RAISED KERB
RD_EX_LOW BLUE DASHDOT2 0.70 LIMIT OF WORKS
EXISTING ROAD FEATURE :
RD_EX_MBK YELLOW Continuous 0.25
EMBANKMENT
EXISTING ROAD FEATURE :
RD_EX_MEDIAN GREEN Continuous 0.35
MEDIAN
EXISTING ROAD FEATURE :
RD_EX_OTHR RED Continuous 0.10
OTHER INFORMATION
EXISTING ROAD FEATURE :
RD_EX_PBAY GREEN Continuous 0.35
PARKING BAY
EXISTING ROAD FEATURE :
RD_EX_PDCR 8 Continuous 0.20
PEDESTRIAN CROSSING
EXISTING ROAD FEATURE :
RD_EX_PRAMP GREEN Continuous 0.35
PEDESTRIAN RAMP
EXISTING ROAD FEATURE :
RD_EX_PRKG WHITE Continuous 0.25
PARKING
EXISTING ROAD FEATURE : IPS,
RD_EX_PTS YELLOW Continuous 0.25
CURVE POINTS ETC

Page 82 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING ROAD DESIGN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING ROAD FEATURE


REPRESENTATION : PAVEMENT
RD_EX_PVMT WHITE Continuous 0.25
(ASPHALT, BITMAC, CONCRETE
ETC.)
EXISTING ROAD FEATURE : RAIL
RD_EX_RAILCOR 252 Continuous 0.15
CORRIDOR
EXISTING ROAD FEATURE :
RD_EX_RAILWAY WHITE TRACKS2 0.25
RAILWAY
RD_EX_RAMP YELLOW Continuous 0.25 EXISTING ROAD FEATURE : RAMP
EXISTING ROAD FEATURE: ROAD
RD_EX_RBTR 8 Continuous 0.20
BATTER

EXISTING ROAD FEATURE : ROAD


RD_EX_REDG WHITE Continuous 0.25
EDGE

EXISTING ROAD FEATURE: ROAD


RD_EX_RLVL WHITE Continuous 0.25
LEVEL
EXISTING ROAD FEATURE :
RD_EX_RNDA WHITE Continuous 0.25
ROUND ABOUT

EXISTING ROAD FEATURE :


RD_EX_RRAP 8 Continuous 0.20
RIPRAP

EXISTING ROAD FEATURE : ROAD


RD_EX_RSLAB RED Continuous 0.10
SLAB

EXISTING ROAD FEATURE : ROAD


RD_EX_RSTL WHITE Continuous 0.25
SPEED TABLE
RD_EX_SBAR- EXISTING ROAD FEATURE :
14 END_TERMINAL 0.35
END SAFETY BARRIER END TERMINAL

Page 83 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING ROAD DESIGN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
RD_EX_SBAR- EXISTING ROAD FEATURE :
30 TERMINAL 0.35
TERM SAFETY BARRIER TERMINAL

EXISTING ROAD FEATURE :


RD_EX_SDITCH 44 Continuous 0.35
SWALE DITCH

EXISTING ROAD FEATURE:


RD_EX_SHLDR GREEN Continuous 0.35
SHOULDER

EXISTING ROAD FEATURE: ROAD


RD_EX_SPTR 20 Continuous 0.35
SEPARATOR
EXISTING ROAD FEATURE :
RD_EX_STAIRS YELLOW Continuous 0.25
STAIRS
EXISTING ROAD FEATURE :
RD_EX_SWAY 190 Continuous 0.35
PEDESTRIAN SUBWAY

EXISTING ROAD FEATURE : TRIAL


RD_EX_TPIT WHITE Continuous 0.25
PIT
EXISTING ROAD FEATURE:
RD_EX_UPSS YELLOW Continuous 0.25
UNDERPASS TUNNEL
EXISTING ROAD FEATURE:
RD_EX_VBAR MAGENTA Continuous 0.35
VEHICLE BARRIER

RD_EX_VERGE YELLOW Continuous 0.25 EXISTING ROAD FEATURE: VERGE

EXISTING ROAD FEATURE : ALL


RD_EX_WALL 40 Continuous 0.35
WALLS

Page 84 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

A.4.2 Traffic and Safety

PROPOSED TRAFFIC AND SAFETY LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

TRAFFIC : BARRIERS, RAILS &


RD_PR_TS_BARL GREEN Continuous 0.35
BOLLARDS
TRAFFIC : CONTROL BOX OR
RD_PR_TS_CTRL_BOX RED Continuous 0.10
SERVICE BOX
RD_PR_TS_DET_LOOP 8 Continuous 0.20 TRAFFIC : DETECTOR LOOP

RD_PR_TS_DUCT 30 Continuous 0.35 TRAFFIC : DUCT


RD_PR_TS_DUCT_ATT WHITE Continuous 0.25 TRAFFIC : DUCT NUMBER
RD_PR_TS_HMPL 8 Continuous 0.20 TRAFFIC : SPEED HUMP

RD_PR_TS_INCH 12 Continuous 0.35 TRAFFIC : INSPECTION CHAMBER


RD_PR_TS_MNHL YELLOW Continuous 0.25 TRAFFIC : MANHOLE

RD_PR_TS_OHLL WHITE Continuous 0.25 TRAFFIC : OVERHEAD CABLE/LINE

RD_PR_TS_OTHR YELLOW Continuous 0.25 TRAFFIC : OTHER

RD_PR_TS_PBDG 31 Continuous 0.35 TRAFFIC : PEDESTRIAN BRIDGE

RD_PR_TS_PGR 40 Continuous 0.35 TRAFFIC : PEDESTRIAN GUARDRAIL

RD_PR_TS_PMTR 40 Continuous 0.35 TRAFFIC : PARKING METERS

TRAFFIC : PEDESTRIAN PUSH


RD_PR_TS_PPBN 13 Continuous 0.60
BUTTON

RD_PR_TS_PUP 13 Continuous 0.60 TRAFFIC : PEDESTRIAN UNDERPASS

TRAFFIC : ROAD DIRECTIONAL


RD_PR_TS_RDSN YELLOW Continuous 0.25 SIGNS (EX: DIRECTIONS, LIMITS
ETC.)
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_500 WHITE Continuous 0.25
MARKING LINE CODE 500
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_501 WHITE QTM501 0.25
MARKING LINE CODE 501

Page 85 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TRAFFIC AND SAFETY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED ROAD FEATURE: ROAD


RD_PR_TS_RM_502 WHITE QTM502 0.25
MARKING LINE CODE 502
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_503 WHITE Continuous 0.25
MARKING POLYGON CODE 503
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_504 WHITE Continuous 0.25
MARKING POLYGON CODE 504
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_505 WHITE QTM505 0.25
MARKING LINE CODE 505
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_506 WHITE QTM506 0.25
MARKING LINE CODE 506
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_507 WHITE QTM507 0.25
MARKING LINE CODE 507
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_508 WHITE Continuous 0.25
MARKING LINE CODE 508
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_509 WHITE QTM509 0.25
MARKING LINE CODE 509
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_510 WHITE Continuous 0.25
MARKING LINE CODE 510
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_511 WHITE QTM511 0.25
MARKING LINE CODE 511
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_512 WHITE QTM512 0.25
MARKING LINE CODE 512
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_513 WHITE Continuous 0.25
MARKING LINE CODE 513
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_
YELLOW Continuous 0.25 MARKING LINE CODE
513Y
513Y - THICK YELLOW LINE

Page 86 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TRAFFIC AND SAFETY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED ROAD FEATURE: ROAD


RD_PR_TS_RM_514 WHITE Continuous 0.25
MARKING POLYGON CODE 514
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_515 WHITE Continuous 0.25
MARKING POLYGON CODE 515
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_516 WHITE Continuous 0.25
MARKING POLYGON CODE 516
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_517 WHITE Continuous 0.25
MARKING POLYGON CODE 517
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_518 WHITE Continuous 0.25
MARKING POLYGON CODE 518
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_519 WHITE Continuous 0.25
MARKING LINE CODE 519
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_520 WHITE Continuous 0.25
MARKING LINE CODE 520
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_521 WHITE Continuous 0.25
MARKING POLYGON CODE 521
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_522 WHITE Continuous 0.25
MARKING POLYGON CODE 522
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_523 WHITE Continuous 0.25
MARKING POLYGON CODE 523
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_524 WHITE Continuous 0.25
MARKING POLYGON CODE 524
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_525 WHITE Continuous 0.25
MARKING LINE CODE 525
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_526 WHITE Continuous 0.25
MARKING LINE CODE 526

Page 87 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TRAFFIC AND SAFETY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED ROAD FEATURE: ROAD


RD_PR_TS_RM_527 WHITE Continuous 0.25
MARKING LINE CODE 527
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_528 WHITE Continuous 0.25
MARKING LINE CODE 528
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_529 WHITE Continuous 0.25
MARKING LINE CODE 529
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_530 WHITE Continuous 0.25
MARKING LINE CODE 530
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_531 WHITE Continuous 0.25
MARKING POLYGON CODE 531
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_532 WHITE Continuous 0.25
MARKING POLYGON CODE 532
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_533 WHITE Continuous 0.25
MARKING POLYGON CODE 533
PROPOSED ROAD FEATURE: ROAD
RD_PR_TS_RM_534 WHITE Continuous 0.25
MARKING LINE CODE 534
RD_PR_TS_SHEAD 13 Continuous 0.60 TRAFFIC : SIGNAL HEAD

RD_PR_TS_SHEAD_
WHITE Continuous 0.25 TRAFFIC : SIGNAL HEAD NUMBER
ATT
TRAFFIC : SIGNS (EX: WARNINGS,
RD_PR_TS_SIGN WHITE Continuous 0.25
SPEED LIMITS ETC.)
RD_PR_TS_SIGN_
WHITE Continuous 0.25 TRAFFIC : SIGN POST
POST
RD_PR_TS_SIGNAL WHITE Continuous 0.25 TRAFFIC : SIGNAL
RD_PR_TS_SIGNAL_
WHITE Continuous 0.25 TRAFFIC SIGNAL POST/POLE
POST

RD_PR_TS_STNM GREEN Continuous 0.35 TRAFFIC : STREET NAME POST/SIGN

Page 88 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TRAFFIC AND SAFETY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

RD_PR_TS_STUDS 8 Continuous 0.20 TRAFFIC : STUDS

RD_PR_TS_TCAM 13 Continuous 0.60 TRAFFIC : CAMERA

TRAFFIC : ANNOTATIONS /
RD_PR_TS_TEXT WHITE Continuous 0.25
DESCRIPTIVE TEXT

RD_PR_TS_TPP 8 Continuous 0.20 TRAFFIC : POLICE PLATFORM

TRAFFIC : UNDERGROUND
RD_PR_TS_UGLL YELLOW Continuous 0.25
CABLE/LINE

EXISTING TRAFFIC AND SAFETY LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TRAFFIC : BARRIERS, RAILS &
RD_EX_TS_BARL GREEN Continuous 0.35
BOLLARDS
TRAFFIC : CONTROL BOX OR
RD_EX_TS_CTRL_BOX RED Continuous 0.10
SERVICE BOX
RD_EX_TS_DET_LOOP 8 Continuous 0.20 TRAFFIC : DETECTOR LOOP
RD_EX_TS_DUCT 30 Continuous 0.35 TRAFFIC : DUCT
RD_EX_TS_DUCT_ATT YELLOW Continuous 0.25 TRAFFIC : DUCT NUMBER
RD_EX_TS_HMPL 8 Continuous 0.20 TRAFFIC : SPEED HUMP

RD_EX_TS_INCH 12 Continuous 0.35 TRAFFIC : INSPECTION CHAMBER

RD_EX_TS_MNHL YELLOW Continuous 0.25 TRAFFIC : MANHOLE

RD_EX_TS_OHLL WHITE Continuous 0.25 TRAFFIC : OVERHEAD CABLE/LINE

RD_EX_TS_OTHR YELLOW Continuous 0.25 TRAFFIC : OTHER

RD_EX_TS_PBDG 31 Continuous 0.35 TRAFFIC : PEDESTRIAN BRIDGE

Page 89 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TRAFFIC AND SAFETY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

RD_EX_TS_PGR 40 Continuous 0.35 TRAFFIC : PEDESTRIAN GUARDRAIL

RD_EX_TS_PMTR 40 Continuous 0.35 TRAFFIC : PARKING METERS

TRAFFIC : PEDESTRIAN PUSH


RD_EX_TS_PPBN 13 Continuous 0.60
BUTTON

RD_EX_TS_PUP 13 Continuous 0.60 TRAFFIC : PEDESTRIAN UNDERPASS

TRAFFIC : ROAD DIRECTIONAL


RD_EX_TS_RDSN YELLOW Continuous 0.25 SIGNS (EX: DIRECTIONS, LIMITS
ETC.)

EXISTING ROAD FEATURE: ROAD


RD_EX_TS_RM_500 WHITE Continuous 0.25
MARKING LINE CODE 500

EXISTING ROAD FEATURE: ROAD


RD_EX_TS_RM_501 WHITE QTM501 0.25
MARKING LINE CODE 501

EXISTING ROAD FEATURE: ROAD


RD_EX_TS_RM_502 WHITE QTM502 0.25
MARKING LINE CODE 502

EXISTING ROAD FEATURE: ROAD


RD_EX_TS_RM_503 WHITE Continuous 0.25
MARKING POLYGON CODE 503

EXISTING ROAD FEATURE: ROAD


RD_EX_TS_RM_504 WHITE Continuous 0.25
MARKING POLYGON CODE 504

EXISTING ROAD FEATURE: ROAD


RD_EX_TS_RM_505 WHITE QTM505 0.25
MARKING LINE CODE 505
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_506 WHITE QTM506 0.25
MARKING LINE CODE 506

Page 90 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TRAFFIC AND SAFETY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING ROAD FEATURE: ROAD


RD_EX_TS_RM_507 WHITE QTM507 0.25
MARKING LINE CODE 507
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_508 WHITE Continuous 0.25
MARKING LINE CODE 508
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_509 WHITE QTM509 0.25
MARKING LINE CODE 509
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_510 WHITE Continuous 0.25
MARKING LINE CODE 510
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_511 WHITE QTM511 0.25
MARKING LINE CODE 511
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_512 WHITE QTM512 0.25
MARKING LINE CODE 512
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_513 WHITE Continuous 0.25
MARKING LINE CODE 513
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_
YELLOW Continuous 0.25 MARKING LINE CODE 513Y - THICK
513Y
YELLOW LINE
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_514 WHITE Continuous 0.25
MARKING POLYGON CODE 514
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_515 WHITE Continuous 0.25
MARKING POLYGON CODE 515
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_516 WHITE Continuous 0.25
MARKING POLYGON CODE 516
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_517 WHITE Continuous 0.25
MARKING POLYGON CODE 517
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_518 WHITE Continuous 0.25
MARKING POLYGON CODE 518

Page 91 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TRAFFIC AND SAFETY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING ROAD FEATURE: ROAD


RD_EX_TS_RM_519 WHITE Continuous 0.25
MARKING LINE CODE 519
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_520 WHITE Continuous 0.25
MARKING LINE CODE 520
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_521 WHITE Continuous 0.25
MARKING POLYGON CODE 521
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_522 WHITE Continuous 0.25
MARKING POLYGON CODE 522
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_523 WHITE Continuous 0.25
MARKING POLYGON CODE 523
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_524 WHITE Continuous 0.25
MARKING POLYGON CODE 524
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_525 WHITE Continuous 0.25
MARKING LINE CODE 525
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_526 WHITE Continuous 0.25
MARKING LINE CODE 526
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_527 WHITE Continuous 0.25
MARKING LINE CODE 527
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_528 WHITE Continuous 0.25
MARKING LINE CODE 528
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_529 WHITE Continuous 0.25
MARKING LINE CODE 529
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_530 WHITE Continuous 0.25
MARKING LINE CODE 530
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_531 WHITE Continuous 0.25
MARKING POLYGON CODE 531

Page 92 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TRAFFIC AND SAFETY LAYERS (Continuation...)


Plotted
Screen
Layer Name Linetype Line Description
Colour
weight

EXISTING ROAD FEATURE: ROAD


RD_EX_TS_RM_532 WHITE Continuous 0.25
MARKING POLYGON CODE 532
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_533 WHITE Continuous 0.25
MARKING POLYGON CODE 533
EXISTING ROAD FEATURE: ROAD
RD_EX_TS_RM_534 WHITE Continuous 0.25
MARKING LINE CODE 534
RD_EX_TS_SHEAD 13 Continuous 0.60 TRAFFIC : SIGNAL HEAD
RD_EX_TS_SHEAD_
WHITE Continuous 0.25 TRAFFIC : SIGNAL HEAD NUMBER
ATT
TRAFFIC : SIGNS (EX: WARNINGS,
RD_EX_TS_SIGN WHITE Continuous 0.25
SPEED LIMITS ETC.)
RD_EX_TS_SIGN_
WHITE Continuous 0.25 TRAFFIC : SIGN POST
POST
RD_EX_TS_SIGNAL WHITE Continuous 0.25 TRAFFIC SIGNAL
RD_EX_TS_SIGNAL
WHITE Continuous 0.25 TRAFFIC SIGNAL POST/POLE
_POST
RD_EX_TS_STNM GREEN Continuous 0.35 TRAFFIC : STREET NAME POST/SIGN
RD_EX_TS_STUDS 8 Continuous 0.20 TRAFFIC : STUDS
RD_EX_TS_TCAM 13 Continuous 0.60 TRAFFIC : CAMERA
TRAFFIC : ANNOTATIONS
RD_EX_TS_TEXT WHITE Continuous 0.25
/DESCRIPTIVE TEXT
RD_EX_TS_TPP 8 Continuous 0.20 TRAFFIC : POLICE PLATFORM
TRAFFIC : UNDERGROUND
RD_EX_TS_UGLL YELLOW Continuous 0.25
CABLE/LINE

Page 93 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

A.4.3 Street Lighting Layers

PROPOSED STREET LIGHTING LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight
PROPOSED ROAD FEATURE :
RD_PR_ST_10sq
CYAN SL_10MM_4C 0.50 STREET LIGHTING CABLE 10 Sq.
mm CBLE
mm
PROPOSED ROAD FEATURE :
RD_PR_ST_16sq
CYAN SL_16MM_4C 0.50 STREET LIGHTING CABLE 16 Sq.
mm CBLE
mm
PROPOSED ROAD FEATURE :
RD_PR_ST_25sq
CYAN SL_25MM_4C 0.50 STREET LIGHTING CABLE 25 Sq.
mm CBLE
mm
PROPOSED ROAD FEATURE :
RD_PR_ST_35sq
CYAN SL_35MM_4C 0.50 STREET LIGHTING CABLE 35 Sq.
mm CBLE
mm
PROPOSED ROAD FEATURE :
RD_PR_ST_2c-
GREEN SL_2.5MM_2C 0.35 PUBLIC REALM LIGHTING CABLE
2.5sq mm CBLE
2c-2.5sq mm
PROPOSED ROAD FEATURE :
RD_PR_ST_2c-
GREEN SL_16MM_2C 0.35 PUBLIC REALM LIGHTING CABLE
16sq mm CBLE
2c-16sq mm
PROPOSED ROAD FEATURE:
RD_PR_ST_CBLE CYAN Continuous 0.50
STREET LIGHTING CABLE
PROPOSED ROAD FEATURE:
RD_PR_ST_DUCT 20 Continuous 0.35
STREET LIGHTING DUCT
PROPOSED ROAD FEATURE :
RD_PR_ST_ERTH GREEN Continuous 0.35
STREET LIGHTING EARTHING
PROPOSED ROAD FEATURE:
RD_PR_ST_FDPL MAGENTA Continuous 0.35
STREET LIGHTING FEEDER PILLAR

Page 94 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STREET LIGHTING LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
PROPOSED ROAD FEATURE :
RD_PR_ST_LIGHT CYAN Continuous 0.50
LIGHTING OTHER THAN STREET
PROPOSED ROAD FEATURE:
RD_PR_ST_POLE YELLOW Continuous 0.25 LIGHTING POLES (UNDERPASS /
STREET LIGHTING POLE
OVERPASS / SUBWAY ETC)
PROPOSED ROAD FEATURE:
RD_PR_ST_SUBSTN CYAN Continuous 0.50
STREET LIGHTING SUBSTATION
PROPOSED ROAD FEATURE:
RD_PR_ST_TEXT WHITE Continuous 0.25 STREET LIGHTING
ANNOTATION/TEXT

EXISTING STREET LIGHTING LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING ROAD FEATURE :


RD_EX_ST_10sq mm
153 SL_10MM_4C 0.35 STREET LIGHTING CABLE 10 Sq.
CBLE
mm
EXISTING ROAD FEATURE :
RD_EX_ST_16sq mm
153 SL_16MM_4C 0.35 STREET LIGHTING CABLE 16 Sq.
CBLE
mm
EXISTING ROAD FEATURE :
RD_EX_ST_25sq mm
153 SL_25MM_4C 0.35 STREET LIGHTING CABLE 25 Sq.
CBLE
mm
EXISTING ROAD FEATURE :
RD_EX_ST_35sq mm
153 SL_35MM_4C 0.35 STREET LIGHTING CABLE 35 Sq.
CBLE
mm
EXISTING ROAD FEATURE :
RD_EX_ST_2c-2.5sq
YELLOW SL_2.5MM_2C 0.25 PUBLIC REALM LIGHTING
mm CBLE
CABLE 2c-2.5sq mm

Page 95 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STREET LIGHTING LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
EXISTING ROAD FEATURE :
RD_EX_ST_2c-16sq
YELLOW SL_16MM_2C 0.25 PUBLIC REALM LIGHTING
mm CBLE
CABLE 2c-16sq mm

EXISTING ROAD FEATURE:


RD_EX_ST_CBLE 153 DASHED2 0.35
STREET LIGHTING CABLE

EXISTING ROAD FEATURE:


RD_EX_ST_DUCT 30 HIDDEN2 0.35
STREET LIGHTING DUCT
EXISTING ROAD FEATURE :
RD_EX_ST_ERTH GREEN Continuous 0.35
STREET LIGHTING EARTHING

EXISTING ROAD FEATURE:


RD_EX_ST_FDPL MAGENTA Continuous 0.35 STREET LIGHTING FEEDER
PILLAR
EXISTING ROAD FEATURE :
RD_EX_ST_LIGHT 153 Continuous 0.35 LIGHTING OTHER THAN
STREET LIGHTING POLES
(UNDERPASS/OVERPASS/SUBW
EXISTING ROAD FEATURE:
RD_EX_ST_POLE 8 Continuous 0.20
AY ETC)LIGHTING POLE
STREET

EXISTING ROAD FEATURE:


RD_EX_ST_SUBSTN CYAN Continuous 0.50
STREET LIGHTING SUBSTATION

EXISTING ROAD FEATURE:


RD_EX_ST_TEXT YELLOW Continuous 0.25 STREET LIGHTING
ANNOTATION/TEXT

Page 96 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

A.4.4 Road Furniture Layers

ROAD FURNITURE LAYERS

Screen Plotted Line


Layer Name Linetype Description
Colour weight
ROAD/STREET FURNITURE:
RD_F_BNCH YELLOW Continuous 0.25
BENCH/SEAT
RD_F_LGHT WHITE Continuous 0.25 ROAD/STREET FURNITURE: LIGHTING

RD_F_OTHR WHITE Continuous 0.25 ROAD/STREET FURNITURE: OTHERS

ROAD/STREET FURNITURE: PLANTER


RD_F_PBX WHITE Continuous 0.25
BOX
RD_F_POLE YELLOW Continuous 0.25 ROAD/STREET FURNITURE: POLE
ROAD/STREET FURNITURE:
RD_F_TEXT WHITE Continuous 0.25
ANNOTATION/TEXT

A.4.5 Road Network Plan Layers

ROAD NETWORK PLAN LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight
PROPOSED ROAD NETWORK PLAN :
RD_NP-CDRD 43 Continuous 0.35
COLLECTOR DISTRIBUTER ROAD
PROPOSED ROAD NETWORK PLAN :
RD_NP-LARD 252 Continuous 0.15
LOCAL ACCESS ROAD
PROPOSED ROAD NETWORK PLAN :
RD_NP-LINKRD 210 Continuous 0.35
LINK ROAD
PROPOSED ROAD NETWORK PLAN :
RD_NP-SERRD 43 Continuous 0.35
SERVICE ROAD
PROPOSED ROAD NETWORK PLAN :
RD_NP-SLIPRD 30 Continuous 0.35
SLIP ROAD
PROPOSED ROAD NETWORK PLAN :
RD_NP-UAMAJ 80 Continuous 0.60
URBAN MAJOR ARTERIAL

Page 97 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

ROAD NETWORK PLAN LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
PROPOSED ROAD NETWORK PLAN :
RD_NP-UAMIN 62 Continuous 0.35
URBAN MINOR ARTERIAL
PROPOSED ROAD NETWORK PLAN :
RD_NP-UCMAJ 170 Continuous 0.35
URBAN COLLECTOR MAJOR
PROPOSED ROAD NETWORK PLAN :
RD_NP-UCMIN 130 Continuous 0.35
URBAN COLLECTOR MINOR

PROPOSED ROAD NETWORK PLAN :


RD_NP-UEXW 10 Continuous 0.60
URBAN EXPRESSWAY

A.4.6 Roads – Common Layers

ROADS - COMMON LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

ALL VERY THIN HIDDEN


RD_C_10HID RED HIDDEN2 0.10
LINES
RD_C_10OUT RED Continuous 0.10 ALL VERY THIN OUT LINES
RD_C_25DASH WHITE DASHED2 0.25 HIDDEN DETAILS
RD_C_25HID WHITE HIDDEN2 0.25 HIDDEN DETAILS
RD_C_25OUT WHITE Continuous 0.25 ALL THIN OUT LINES
ALL OUTLINES IN
RD_C_35OUT GREEN Continuous 0.35
PLAN/ELEVATION
ALL CONCRETE OUTLINES IN
RD_C_50OUT CYAN Continuous 0.50
SECTION
RD_C_50REBARS CYAN Continuous 0.50 REINFORCEMENT DETAILS
ALL CONCRETE OUTLINES IN
RD_C_70OUT BLUE Continuous 0.70
SECTION

Page 98 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

ROADS - COMMON LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
RD_C_ABANDONED RED Continuous 0.10 ABANDONED

RD_C_CHAIN_MARK YELLOW Continuous 0.25 FEATURES MARKING


CHAINAGE

RD_C_CHAIN_TEXT WHITE Continuous 0.25 CHAINAGE TEXT

RD_C_CONT_MAJR 8 Continuous 0.20 MAJOR CONTOUR


RD_C_CONT_MINR 9 Continuous 0.15 MINOR CONTOUR
RD_C_CTRLINE RED CENTER2 0.10 CENTRE LINE
RD_C_HATCH RED Continuous 0.10 ALL HATCHES

SHEET CONTINUATION
RD_C_MATCH_LINE BLUE PHANTOM 0.70
MATCH LINE
ROADWAYS: PROFILE
RD_C_PROF_ASMC 92 Continuous 0.35
ASSYMETRICAL
ROADWAYS:
CURVES PROFILE
RD_C_PROF_BUILD_LINE_LHS 10 ROAD_PROFILE 0.60 GL AT BUILDING LINE
LEFT HAND SIDE
ROADWAYS: PROFILE
RD_C_PROF_BUILD_LINE_RHS 170 ROAD_PROFILE 0.35 GL AT BUILDING LINE
RIGHT HAND SIDE
ROADWAYS: PROFILE
RD_C_PROF_CURV BLUE Continuous 0.70
VERTICAL CURVES
ROADWAYS: PROFILE
RD_C_PROF_DIAG CYAN Continuous 0.50
BAND DIAGRAMS
ROADWAYS: PROFILE
RD_C_PROF_EG YELLOW DASHED2 0.25
EXISTING
ROADWAYS: PROFILE
RD_C_PROF_FG CYAN Continuous 0.50
PROPOSED
ROADWAYS: PROFILE
RD_C_PROF_GRADED_SURF 210 ROAD_PROFILE 0.35
GRADED SURFACE

Page 99 of 208
PWA CAD STANDARDS MANUAL V 5.0
September 2017

ROADS - COMMON LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

RD_C_PROF_GRID 150 Continuous 0.35 ROADWAYS: PROFILE GRID

ROADWAYS: PROFILE
RD_C_PROF_GRID-GEOM MAGENTA Continuous 0.35
GRIDLINE @ GEOMETRY
ROADWAYS:
POINTS PROFILE
RD_C_PROF_GRID-MAJR 251 Continuous 0.15
GRIDLINE @ MAJOR
ROADWAYS:
STATIONS PROFILE
RD_C_PROF_GRID-MINR 251 Continuous 0.15
GRIDLINE @ MINOR

RD_C_PROF_LABL 8 Continuous 0.20 STATIONS


ROADWAYS: PROFILE LABEL

ROADWAYS: PROFILE
RD_C_PROF_LINE RED Continuous 0.10
VERTICAL LINES
ROADWAYS: CENTERLINE
RD_C_PROF_LINE-EXTN 252 HIDDEN 0.15
EXTENSION
ROADWAYS: PROFILE LEFT
RD_C_PROF_LTOF RED Continuous 0.10
OFFSET SAMPLE LINE
ROADWAYS: PROFILE
RD_C_PROF_PARB WHITE Continuous 0.25
PARABOLIC CURVES
ROADWAYS: PROFILE
RD_C_PROF_PNTS 252 HIDDEN 0.15
GEOMETRY POINTS
RD_C_PROF_PROJ 92 Continuous 0.35

ROADWAYS: PROFILE RIGHT


RD_C_PROF_RTOF RED Continuous 0.10
OFFSET SAMPLE LINE
ROADWAYS: PROFILE
RD_C_PROF_STAN-GEOM WHITE Continuous 0.25
GEOMETRY POINT LABELS
ROADWAYS: PROFILE MAJOR
RD_C_PROF_STAN-MAJR YELLOW Continuous 0.25
STATION LABELS

Page 100 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

ROADS - COMMON LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
ROADWAYS: PROFILE MINOR
RD_C_PROF_STAN-MINR RED Continuous 0.10
STATION LABELS
RD_C_PROF_TEXT WHITE Continuous 0.25 ROADWAYS: PROFILE TEXT

ROADWAYS: PROFILE TICK


RD_C_PROF_TICK 251 Continuous 0.15
MARKS
RD_C_PROF_TITL WHITE Continuous 0.25 ROADWAYS: PROFILE LABEL

SURVEY ROAD FEATURE :


RD_C_SPT_HGT YELLOW Continuous 0.25
SPOT HEIGHT MARKER & TEXT

SURVEY ROAD FEATURE :


RD_C_SPT_NUM YELLOW Continuous 0.25
SURVEY POINT NUMBER
RD_C_TABLE WHITE Continuous 0.25 TABLES

RD_C_TEXT WHITE Continuous 0.25 COMMON TEXT

A.5 Town Beautification Layers

A.5.1 Town Beautification – Landscaping Layers

TOWN BEAUTIFICATION – LANDSCAPING LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TOWN BEAUTIFICATION (LANDSCAPE)
TB_L_AGAVE 76 Continuous 0.35
AGAVE TREES

TB_L_ TOWN BEAUTIFICATION (LANDSCAPE)


12 Continuous 0.35
ALTERNANTHERA ALTERNANTHERA TREES

TB_L_ARTSCAPE Green Continuous 0.35 ARTSCAPE

Page 101 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TOWN BEAUTIFICATION
TB_L_ASPARAGUS 90 Continuous 0.35
(LANDSCAPE) ASPARAGUS TREES
TB_L_BAND Red Continuous 0.10 BANDS IN PAVING
TB_L_BENCH Green Continuous 0.35 LANDSCAPE BENCHES
TB_L_BIKE RACK Green Continuous 0.35 BIKE RACK
TB_L_BIN Green Continuous 0.35 LITTER BINS
TB_L_BOLLARD Green Continuous 0.35 BOLLARD
TB_L_BREAKLINE 11 Continuous 0.35 CUT LINE
TAGGING FOR LANDSCAPE
TB_L_BUFFER_TYPE White Continuous 0.25
BUFFER TYPES
TB_L_BUSH 90 Continuous 0.35 BUSH
TOWN BEAUTIFICATION
TB_L_CANNA 192 Continuous 0.35
(LANDSCAPE) CANNA TREES
CENTER LINE FOR VARIOUS
TB_L_CENTER 11 CENTER 0.35
LANDSCAPE SETTING OUTS
TB_L_CLIMBER_SUP Red FENCELINE 0.10 CLIMBER SUPPORT

TB_L_CLIMBERS Red 2
Continuous 0.10 CLIMBERS
TB_L_CONC 10 Continuous 0.60 CONCRETE IN SECTION
TB_L_CONTOUR Green Continuous 0.35 CONTOUR LINE
TB_L_COORDINATES Yellow Continuous 0.25 COORDINATES
TB_L_CO-PLAM Yellow Continuous 0.25 ORNAMENTAL PALMS
TB_L_CORNER_TYPE White Continuous 0.25 TAGGING FOR CORNERS TYPES
TB_L_CORRIDOR_TYPE White Continuous 0.25 TAGGING FOR CORRIDOR TYPES
TB_L_DECORATIVE
9 HIDDEN 0.15 LANDSCAPE SHADE STRUCTURE
SHADE STRUCTURE
TB_L_DIM Red Continuous 0.10 ALL TYPE OF DIMENSIONS

Page 102 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Layer Name Screen Colour Linetype Line Description

weight
TB_L_DRAINAGE
White Continuous 0.25 DRAINAGE SYMBOLS
SYMBOLS
TB_L_DROP KERB 9 HIDDEN 0.15 DROP KERB INDICATION
TB_L_DUCT Yellow HIDDEN 0.25 DUCT
BBQ, DR FOUNTAINS, TRASH
TB_L_FACILITIES 20 Continuous 0.35
BINS
TB_L_FENCE Green Continuous 0.35 LANDSCAPE FENCE LINES
TAGGING FOR ALL FITNESS
TB_L_FE_TAG Yellow Continuous 0.25
EQUIPMENTS
ALL TYPE OF FITNESS
Yellow Continuous 0.25
TB_L_FIT_EQUI EQUIPMENTS
TB_L_FUR_TAG Yellow Continuous 0.25 TAGGING FOR ALL FURNITURES

TB_L_GARBAGE_BIN 96 Continuous 0.35 GARBAGE BIN


ALTHENANTHERA BETZICKIANA
TB_L_GC_ABR_ALBE 244 Continuous 0.35
RED
TB_L_GC_ACB_APCO 232 Continuous 0.35 APTENIA CORDIFOLIA
TB_L_GC_AD_ALDE 100 Continuous 0.35 ALTHENANTHERA DENTATA
TB_L_GC_ASA_ALSA 51 Continuous 0.35 ALYSSUM SAXATILE
TB_L_GC_AST_ASTE 49,72,20 Continuous 0.35 ASPHODELUS TENUIFOLIUS
TB_L_GC_AV_ALVE 15 Continuous 0.35 ALTERANTHERA VERSICOLOR

TB_L_GC_BGR_BORE 255,36,145 Continuous 0.35 BOUGAINVILLEA GLABRA RED

BOUGAINVILLEA GLABRA
TB_L_GC_BGW_BOWH 166,166,166 Continuous 0.15
WHITE
BOUGAINVILLEA GLABRA
TB_L_GC_BGY_BOYE 227,255,143 Continuous 0.35
YELLOW
TB_L_GC_CAM_CAMA 52 Continuous 0.35 CARISSA MACROCARPA

Page 103 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Layer Name Screen Colour Linetype Description
Line weight
TB_L_GC_CC_CYCO 108,61,40 Continuous 0.35 CYPERUS CONGLOMERATUS
TB_L_GC_CG_CAGR 105 Continuous 0.35 CARISSA GRANDIFLORA
TB_L_GC_CYA_CYAL 106 Continuous 0.35 CYPERUS ALTERNIFOLIUS
TB_L_GC_GR_GARI 120 Continuous 0.35 GAZANIA RIGENS
HELIOTROPIUM
TB_L_GC_HC_HECU 89,136,107 Continuous 0.35
CURASSAVICUM
TB_L_GC_HPE_HAPE 190,48,30 Continuous 0.35 HALOPEPLIS PERFOLIATA
TB_L_GC_IH_IRHE 222 Continuous 0.35 IRESINE HERBESTII
TB_L_GC_LA_LIAX 135,92,157 Continuous 0.35 LIMONIUM AXILLARE
OSTEOSPERMUM
TB_L_GC_OF_OSFR 151 Continuous 0.35
FRUITCOSUM
TB_L_GC_PA_POAF 0,158,0 Continuous 0.35 PORTULACARIA AFRA
TB_L_GC_PU_PUUN 199,197,72 Continuous 0.35 PULICARIA UNDULATA
TB_L_GC_RE_RUEQ 105 Continuous 0.35 RUSSELIA EQUISETIFORMIS
TB_L_GC_RS_RHSP 160 Continuous 0.35 ROHEO SPTHACEA
TB_L_GC_SAA_SAAE 137,135,108 Continuous 0.20 SALVIA AEGYPTIACA
TB_L_GC_SEP_SEPU 152 Continuous 0.35 SETCREASEA PURPUREA
SESUVIUM
TB_L_GC_SP_SEPO 101 Continuous 0.35
PORTULACASTRUM
TB_L_GC_TEP_TEPO 110,180,177 Continuous 0.35 TEUCRIUM POLIUM
TB_L_GC_WT_WATR 158,119,0 Continuous 0.35 WEDELIA TRILOBATA
GEOTEXTILE MEMBERANE
TB_L_GEOTEX 9 DOT 0.15
FOR TREE AND PALAM
TB_L_GR_AEL_AELA 115,143,30 Continuous 0.35 AELUROPUS LAGOPOIDES
TB_L_GR_CD_CYDA 100 Continuous 0.35 CYNODON DACTYLON
TB_L_GR_CEI_CECI 180,126,163 Continuous 0.35 CENCHRUS CILIARIS
TB_L_GR_CS_COSE 22,106,116 Continuous 0.35 CORTA DERIA SELLOANA

Page 104 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)

Plotted
Layer Name Screen Colour Linetype Description
Line weight

TB_L_GR_CYC_ CYMBOPOGON
255,193,5 Continuous 0.35
CYCO COMMUTATUS
DACTYLOCTENIUM
TB_L_GR_DA_DAAE 179,199,153 Continuous 0.15
AEGYAPTIUM
TB_L_GR_HM_HAMU 53,72,40 Continuous 0.35 HALOPYRUM MUCRONATUM

TB_L_GR_JR_JURI 154,141,91 Continuous 0.35 JUNCUS RIGIDUS


TB_L_GR_LAH_LAHI 182,113,104 Continuous 0.35 LASIURUS HIRSUTUS
TB_L_GR_MR_MURI 188,239,174 Continuous 0.35 MUHLENBERGIA RIGENS
TB_L_GR_PED_PEDI 67,204,219 Continuous 0.35 PENNISETUM DIVISUM
PENNISETUM SETACEUM
TB_L_GR_PM_PERU 240 Continuous 0.35
RUBRAM
TB_L_GR_PS_PESE 70 Continuous 0.35 PENNISETUM SETACEUM
TB_L_GR_PT_PATU 173,202,83 Continuous 0.35 PANICUM TURGIDUM
TB_L_GR_PV_PAVA 70 Continuous 0.35 PASPALLUM VAGINATUM
TB_L_GR_SAR_SPAR 139,167,162 Continuous 0.15 SPOROBOLUS ARABICUS
TB_L_GRASS 90 Continuous 0.35 GRASS OF ALL TYPES
TB_L_GRAVEL 1 11 Continuous 0.35 GRAVEL PAVING
TB_L_GRAVEL 1 OUT White Continuous 0.25 GRAVEL PAVING
TB_L_GRAVEL 2 Red Continuous 0.10 GRAVEL PAVING
TB_L_GRAVEL 2 OUT White Continuous 0.25 GRAVEL PAVING
TB_L_GRAVEL 3 11 Continuous 0.35 GRAVEL PAVING
TB_L_GRAVEL 3 OUT White Continuous 0.25 GRAVEL PAVING
TB_L_GRAVEL Red HIDDEN 0.10 GRAVEL PAVING DIVISION
DIVISION
TB_L_GRAVEL OUT White Continuous 0.25 GRAVEL PAVING
TB_L_GRDN 8 Continuous 0.20 GARDEN

Page 105 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Layer Name Screen Colour Linetype Description
Line weight
TB_L_GROUND_COV Magenta Continuous 0.35 GROUND COVERS
ERS
TB_L_HATC_CAPA_ 0.35 CARPARK CONCRETE
255,122,122 Continuous
CO80 PAVING 80mm THICK
TB_L_HATC_DEPA_ 0.35 DECORATIVE CONCRETE
20 Continuous
CO60 PAVING 60mm THICK
TB_L_HATC_DEPA_ 0.35 DECORATIVE GRANITE
20 Continuous
GR60 PAVING 60mm THICK
TB_L_HATC_DRAC_ 0.20 DIVEWAY ACCESS
8 Continuous
CO80 CONCRETE PAVING 80mm
TB_L_HATC_DRAC_ 0.20 DRIVEWAY
THICK ACCESS GRANITE
8 Continuous
GR80 PAVING 80mm THICK
TB_L_HATC_GRPA 20 Continuous 0.35 GRANITE PAVING AREA
TB_L_HATC_JNPA_ JUCTION CONCRETE PAVING
161 Continuous 0.35
CO60 60mm THICK
TB_L_HATC_MAED_ MAINTENANCE PAVING
253 Continuous 0.15
CO60 CONCRETE 60mm THICK
TB_L_HATC_MAED_ MAINTENANCE EDGE
253 Continuous 0.15
GR60 GRANITE 60mm THICK
MAINTENANCE PATH
TB_L_HATC_MAPA_
253 Continuous 0.15 CONCRETE PAVING 60mm
CO60
THICK
TB_L_HATC_MAPA_ MAINTENANCE PATH
253 Continuous 0.15
GR60 GRANITE 60mm THICK
TB_L_HATC_MEPA_ MEDIAN CONCRETE PAVING
44 Continuous 0.35
CO60 60mm THICK
TB_L_HATC_MEPA_ MEDIAN GRANITE PAVING
44 Continuous 0.35
GR60 60mm THICK

Page 106 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Layer Name Screen Colour Linetype Description
Line weight
PEDESTRIAN CROSSING
TB_L_HATC_PECR_
9 Continuous 0.15 CONCRETE PAVING 60mm
CO60
THICK
PEDESTRIAN CROSSING
TB_L_HATC_PECR_
9 Continuous 0.15 GRANITE PAVING 60mM
GR60
THICK
TB_L_HATC_RAPA_ RAISED CONCRETE PAVING
8 Continuous 0.20
CO80 80mm THICK
TB_L_HATC_SHPA_ SHARED PATH CONCRETE
251 Continuous 0.15
CO60 PAVING60mm THICK
TB_L_HATC_SHPA_ SHARED PATH GRANITE
251 Continuous 0.15
GR60 PAVING 60mm THICK
TB_L_HATC_SIEN_ SIKKA ENTRANCE CONCRETE
251 Continuous 0.15
CO60 PAVING 60mm THICK
TB_L_HATC_SIWA_ SIDE WALK CONCRETE
250 Continuous 0.15
CO60 PAVING 60mm THICK
TB_L_HATC_SIWA_ SIDE WALK GRANITE PAVING
250 Continuous 0.15
GR60 60mm THICK
TB_L_HATC_TABL 255,112,112 Continuous 0.35 TACTILE BLISTER PAVING
TB_L_HATC_TOWE 253 Continuous 0.15 TOWER HATCH
TB_L_HATCH 9 Continuous 0.15 HATCH PATTERNS
TB_L_HATCH OUT White Continuous 0.25 HATCH OUT LINE
TB_L_HEDGES 150 Continuous 0.35 HEDGES
TB_L_HIDDEN 9 HIDDEN 0.15 DASH DOT LINES
TB_L_IMAGE White Continuous 0.25 IMAGES
TB_L_JUNCTION_ TAGGING FOR JUNCTION
Yellow Continuous 0.25
TYPE TYPES
TB_L_KERB Green Continuous 0.35 ROAD KERB

Page 107 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TB_L_KERB THIN 9 Continuous 0.15 BACK SIDE FACE OF THE KERB
TOWN BEAUTIFICATION
TB_L_LANTANA 32 Continuous 0.35
(LANDSCAPE) LANTANA TREES
TB_L_LAWN Yellow Continuous 0.25 GRASS
TB_L_LAWN-
White Continuous 0.25 GRASS OUTLINE FOR CALCULATIONS
CALC
TB_L_LINE_ALST 240 Continuous 0.35 ALUMINUM MOVING STRIP
TB_L_LINE_ARCY 255 Continuous 0.15 BYCICLE ARROW
TB_L_LINE_BILA 32 Continuous 0.35 BIKE LANE OUTER LINE
TB_L_LINE_BREA Red Continuous 0.10 BREAK LINE
BUILDING EDGE LINE OR PROPERTY
TB_L_LINE_BUED Blue Continuous 0.70
LINE
TB_L_LINE_CONT 251 HIDDEN2 0.15 CONTOUR LINES
TB_L_LINE_GEFA White HIDDEN 0.25 GEO TEXTILE MEMBRANE FABRIC

TB_L_LINE_GRLE 30 Continuous 0.35 GROUND LEVEL LINE IN SECTIONS


TB_L_LINE_HIDD White HIDDEN 0.25 HIDDEN LINE WORKS
ALL TYPE OF HATCH BOUNDARY-
TB_L_LINE_HOUT White Continuous 0.25
NON PLOT
ALL TYPE OF LAWN BOUNDARY-
TB_L_LINE_LOUT Yellow Continuous 0.25
NON PLOT
MAINTENANCE EDGE PAVING
TB_L_LINE_MOUT White Continuous 0.25
OUT_NON PLOT
TB_L_LINE_NOZZ 43 Continuous 0.35 WATER NOZZLE
TB_L_LINE_PABA 221 Continuous 0.35 ALL TYPE OF PAVING BANDS
TB_L_LINE_PLAR 150 Continuous 0.35 CHILDERENS PLAY AREA BOUNDARY
LINE BETWEEN PAVING AND
TB_L_LINE_PLED 100 Continuous 0.35
SOFTSCAPE

Page 108 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TB_L_LINE_PLEQ 8 Continuous 0.20 PLAY EQUIPMENT
TB_L_LINE_PLSE 121 Continuous 0.35 LINE BETWEEN PLANT SPECIES
TB_L_LINE_RAWA 32 Continuous 0.35 RAISED WALL OUTER LINE ON PLAN
TB_L_LINE_REFE Cyan HIDDEN 0.50 REFERENCE CALLOUT LINE
TB_L_LINE_ROBA 160 FENCELINE 0.35 ROAD BARRIER
TB_L_LINE_ROBO Red 1
Continuous 0.10 ROCK BOULDERS
TB_L_LINE_SOFT 252 Continuous 0.15 SOFTSCAPE AREA
TB_L_LINE_STEP Magen Continuous 0.35 STEPS LINE IN PLAN
TB_L_LINE_STON ta
Magen Continuous 0.35 STONE LINE WORKS IN SECTIONS
TB_L_LINE_TABL ta
210 Continuous 0.35 TACTILE LINE WORKS
TB_L_LINE_THIC Blue Continuous 0.70 ALL THICK LINE WORKS
TB_L_LINE_THIN 43 Continuous 0.35 ALL THIN LINE WORKS
THE LINE BETWEEN WATER AND
TB_L_LINE_WAED 171 Continuous 0.35
PAVING
TB_L_LINE_WATA 8 HIDDEN2 0.20 WATER TANK LINE WORKS
TB_L_LINE_WOUT White Continuous 0.25 WATER HATCH OUTLINE
TB_L_
Red Continuous 0.10 LANDSCAPE MAINTENANCE EDGE
MAINTENANCE
TB_L_MARKER
EDGE 9 Continuous 0.15 ROAD MARKERS AND SIGN MARKERS

TB_L_NATURAL 23 Continuous 0.35 NATURAL SOIL


SOIL TOWN BEAUTIFICATION (LANDSCAPE)
TB_L_NERIUM 20 Continuous 0.35
NERIUM TREES
TB_L_O-PALM Yellow Continuous 0.25 ORNAMENTAL PALMS
TB_L_OPEN90 Green Continuous 0.35 LEADER LINE
TB_L_PALM Yellow Continuous 0.25 PALM TREE
OUTLINE
TB_L_PALMS 90 Continuous 0.35 PALMS, COCAS, WASHINGTONIAN

Page 109 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TB_L_PATH Red Continuous 0.10 FOOT PATH
TB_L_PAV_TYPE White Continuous 0.25 PAVING TYPES
TB_L_PE_TAG Yellow Continuous 0.25 TAGGING FOR ALL PLAY EQUIPMENTS
PLANT STEM FOR LOCATING SHERBS
TB_L_PLANT STEM Green Continuous 0.35
ETC AS SPECIMEN
PLANTING TYPE A WITH GRAVEL
TB_L_PLANTING A 82 Continuous 0.35
MULCH
PLANTING TYPE B WITH GRAVEL
TB_L_PLANTING B 11 Continuous 0.35
MULCH
PLANTING TYPE C WITH GRAVEL
TB_L_PLANTING C 82 Continuous 0.35
MULCH
PLANTING TYPE D WITH GRAVEL
TB_L_PLANTING D 82 Continuous 0.25
MULCH
PLANTING TYPE E WITH GRAVEL
TB_L_PLANTING E 11 Continuous 0.35
MULCH
TB_L_PLANTING
Yellow Continuous 0.25 EDGE OF PLANTING BED
EDGE
PLANTING TYPE F WITH GRAVEL
TB_L_PLANTING F 101 Continuous 0.35
MULCH
PLANTING TYPE G WITH GRAVEL
TB_L_PLANTING G 82 Continuous 0.35
MULCH
PLANTING TYPE H WITH GRAVEL
TB_L_PLANTING H 82 Continuous 0.35
MULCH
PLANTING TYPE I WITH GRAVEL
TB_L_PLANTING I 61 Continuous 0.35
MULCH
TB_L_PLAY_AREA 150 Continuous 0.35 CHILDREN PLAY AREA
TB_L_POT Red Continuous 0.10 LANDSCAPE POTS
TB_L_RECREATION 8 Continuous 0.20 SPORTS FIELD AND AREAS

Page 110 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Screen
Layer Name Linetype Line Description
Colour
weight
TB_L_REFERENCE Green HIDDEN 0.35 REFFERENCE LINE
TB_L_REFERENCE- REFERENCE BOX FOR SHOWING
Cyan HIDDEN 0.50
BOX ENLARGED DETAILS ETC
TB_L_ROCK 11 Continuous 0.35 LANDSCAPE ROCKS
TB_L_ROCK_BOUL Red Continuous 0.10
TB_L_ROCKOUT Cyan Continuous 0.50 ROCK OUTLINE
TB_L_ROOT_BAR Green Continuous 0.35 ROOT BARRIER
TB_L_RUBBER_SURFA 11 Continuous 0.35 RUBBER SURFACE
CE
TB_L_SALT_BAR White DASHED2 0.25 SALT BARRIER
TB_L_SAND 9 Continuous 0.15 SAND HATCH FOR PLAY AREAS
TB_L_SEASONAL 60 Continuous 0.35 SEASONAL FLOWERS
TB_L_SEAT Green Continuous 0.35 LANDSCAPE SEAT
TB_L_SECULENTS Green Continuous 0.35 SECULENTS
ALTERNANTHERA AMOENA
TB_L_SF_AAM_ALAM 72 Continuous 0.35
(SUMMER)
TB_L_SF_KS_KOSC 212 Continuous 0.35 KOCTRIA SCOPARIA
PETUNIA HYBRIDA PINK / WHITE
TB_L_SF_PH_PEHY 20 Continuous 0.35
(WINTER)
TB_L_SF_TE_TAER 41 Continuous 0.35 TAGETES ERECTA
TB_L_SF_VP_VEPE 213 Continuous 0.35 VERBINA PERUVIANA
TB_L_SF_VR_VIRO 220 Continuous 0.35 VINCA ROSEA
TB_L_SF_ZE_ZIEL 122 Continuous 0.35 ZINNIA ELEGANS
TB_L_SH_AEJ_AEJA 0,250,125 Continuous 0.35 AERVA JAVANICA
TB_L_SH_ANL_ANLE 241 Continuous 0.35 ANTIGONON LEPTOPUS
TB_L_SH_ARM_ ARTHROCNEMUM
86,138,114 Continuous 0.35
ARMA MACROSTACHYUM

Page 111 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Screen
Layer Name Linetype Line Description
Colour
weight

TB_L_SH_AW_ACWI 100 Continuous 0.35 ACALIFA WILKINSIANA


TB_L_SH_BG_BOGL 242 Continuous 0.35 BOUGAINVILLEA GLABRA
TB_L_SH_BT_BOTO 14 Continuous 0.35 BOUGAIN VILLEA TORCH GLOW
TB_L_SH_CB_CABI 52 Continuous 0.35 CASSIA BICAPSULARIS
TB_L_SH_CED_CEDI 116 Continuous 0.35 CETSTRUM DIURNUM
TB_L_SH_CI_CLIN 120 Continuous 0.35 CLERODENDRUM INERME
TB_L_SH_CIN_CAIN 219,164,0 Continuous 0.35 CANNA INDICA
TB_L_SH_CP_CAPU 91 Continuous 0.35 CAESALPINIA PULCHERRIMA
CARISSA PROSTRATA NATAL
TB_L_SH_CPN_CAPR 189,240,61 Continuous 0.35
PALM
TB_L_SH_CPR_CAPR 38,181,46 Continuous 0.35 CALOTROPIS PROCERA
TB_L_SH_GS_GESE 45 Continuous 0.35 GELSEMIUM SEMPERVIRENS
TB_L_SH_HAA_HAAR 116,118,35 Continuous 0.35 HAMMADA ARTICULATA
TB_L_SH_HAS_HAST 80,175,91 Continuous 0.35 HALOCNEMUM STROBILACEM
TB_L_SH_IC_IXCH 255,133,13 Continuous 0.35 IXORA CHENESIS
TB_L_SH_JI_JAIN 3
160 Continuous 0.35 JATROPHA INTEGERRIMA
JASMINUM OFFICINALIS
TB_L_SH_JO_JAOF 105 Continuous 0.35
GRANDIFLORUM
TB_L_SH_LF_LEFR 136 Continuous 0.35 LEOCOFFILUM FRUTESSEN
TB_L_SH_LI_LAIN 120 Continuous 0.35 LAGERSTROEMIA INDICA

TB_L_SH_LYS_LYSH 145,164,61 Continuous 0.35 LYCIUM SHAWII

TB_L_SH_NOP_NEPI 210 Continuous 0.35 NERIUM OLEANDER PINK


TB_L_SH_NOR_NERE 240 Continuous 0.35 NERIUM OLEANDER RED
TB_L_SH_SI_SEIT 199,201,74 Continuous 0.35 SENNA ITALICA
TB_L_SH_SUV_SUVE 164,100,61 Continuous 0.35 SUAEDA VERMICULATA
TB_L_SH_TC_TECA 146 Continuous 0.35 TECOMARIA CAPENSIS

Page 112 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Layer Name Screen Colour Linetype Line Description

weight

TRACHELOSPERMUM
TB_L_SH_TJ_TRJA 196,191,196 Continuous 0.15
JASMINIDES
TB_L_SH_TS_TEST 245,226,15 Continuous 0.25 TECOMA STANS
TB_L_SH_TSM_TRSP 41,219,168 Continuous 0.35 TRADESCANTIA SPATHACEA
TB_L_SH_VA_VIAG 143 Continuous 0.35 VITEX AGNUS CASTUS
TB_L_SHAD_ BEIG 221,194,131 Continuous 0.15 BEIGE COLOUR
TB_L_SHAD_250 250 Continuous 0.15 COLOUR NO-250
TB_L_SHAD_251 251 Continuous 0.15 COLOUR NO-251
TB_L_SHAD_252 252 Continuous 0.15 COLOUR NO-252
TB_L_SHAD_253 253 Continuous 0.15 COLOUR NO-253
TB_L_SHAD_254 254 Continuous 0.15 COLOUR NO-254
TB_L_SHAD_255 255 Continuous 0.15 COLOUR NO-255
TB_L_SHAD_BIKE 166,238,183 Continuous 0.35 BIKE LANE PAVING HATCH
TB_L_SHAD_BUST 252 Continuous 0.15 BUS STOP SHADE
TB_L_SHAD_DABR 230,160,160 Continuous 0.35 DARK BROWN COLOUR
TB_L_SHAD_DAGR 190,190,190 Continuous 0.15 DARK GREY COLOUR
TB_L_SHAD_LIBE 236,222,201 Continuous 0.15 LIGHT BEIGE COLOUR
TB_L_SHAD_LIGR 211,211,211 Continuous 0.15 LIGHT GREY COLOUR
TB_L_SHAD_WATE 151 Continuous 0.35 WATER SHADE
TB_L_SHAD_WHIT 245,245,220 Continuous 0.25 WHITE COLOUR

TB_L_SHADE 252 252 Continuous 0.15 SHADE 252

TB_L_SHADE 253 253 Continuous 0.15 SHADE 253

TB_L_SHADE 254 254 Continuous 0.15 SHADE 254

CLOTH, WOOD, CONCRETE


TB_L_SHADED_AREA 153 Continuous 0.35
SHADES

Page 113 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Layer Name Screen Colour Linetype Line Description

weight
SHRUBS LARGE AND SMALL,
TB_L_SHRUBS Red Continuous 0.10
VINES
TB_L_SIKKA_TYPE White Continuous 0.25 TAGGING FOR SIKKA TYPES
TB_L_SITE_ARWO 210 Continuous 0.35 ART WORK SITE FURNITURE
TB_L_SITE_BENC 210 Continuous 0.35 ALL TYPE OF BENCHES
TB_L_SITE_BENC2 210 Continuous 0.35 TYPE2 BENCHES
TB_L_SITE_BOCR 20 Continuous 0.35 CRASH BOLLARDS
TB_L_SITE_BOLL Magenta Continuous 0.35 COMMON BOLLARDS
TB_L_SITE_BOST Cyan Continuous 0.50 STANDARD BOLLARDS
TB_L_SITE_DRFO 120 Continuous 0.35 DRINKING FOUNTAIN
TB_L_SITE_HARA 41 Continuous 0.35 ALL TYPES OF HAND RAILS
TB_L_SITE_LIBI 210 Continuous 0.35 ALL TYPES OF LITTER BINS
TB_L_SITE_LIBI2 70 Continuous 0.35 LITTER BIN TYPE 2
TB_L_SITE_LITT_BIN 210 Continuous 0.35
TB_L_SITE_MEFE Blue FENCELINE 0.70 MEDIAN FENCE
TB_L_SITE_MIPO 120 1
Continuous 0.35 MISTING POLE
TB_L_SITE_PLEQ 8 Continuous 0.20 PLAY EQUIPMENTS
TB_L_SITE_SESC 120 Continuous 0.35 SCULPTURAL SEATING
TB_L_SITE_SHST 12 Continuous 0.35 SHADE STRUCTURE SITE
TB_L_SITE_SHST2 10 Continuous 0.60 FURNITURE
SHADE STRUCTURE TYPE 2
TB_L_SITE_STRU White Continuous 0.25 HARD STRUCTURE IN SECTIONS
TB_L_SITE_TOWE 12 Continuous 0.35 SITE FURNITURE TOWER

TB_L_SITE_TRGR 251 Continuous 0.15 ALL TYPE OF TREE GRATES

TB_L_SMALL TOTEM Cyan Continuous 0.50 LANDSCAPE ELEMENT


TB_L_SPOT_HEBL Red Continuous 0.10 SPOT HEIGHT LEVEL BLOCK

Page 114 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Layer Name Screen Colour Linetype Line Description

weight
TB_L_SPOT_HETE Yellow Continuous 0.25 SPOT HEIGHT LEVEL TEXT
TB_L_STEEL Red Continuous 0.10 STEEL EDGES
TB_L_STEPS Yellow Continuous 0.25 LANDSCAPE STEPS

TB_L_STONE Magenta Continuous 0.35 ALL STONE SECTION AND PLAN

TB_L_SU_AAG_AGSI 171,190,121 Continuous 0.35 AGAVE SISALANA


TB_L_SU_AFT_AGFO 0,117,27 Continuous 0.35 AGAVE FILAMENTOSA
TB_L_SU_AGA_AGAT 0,112,26 Continuous 0.35 AGAVE ATTENUATA
TB_L_SU_AGC_AGCO 227,254,180 Continuous 0.35 AGAVE COLORATA
TB_L_SU_AGM_AGMA 91 Continuous 0.35 AGAVE MACROCANTHA
TB_L_SU_AGP_AGPA 143 Continuous 0.35 AGAVE PARRYI
TB_L_SU_ALA_ALAR 34 Continuous 0.35 ALOE ARBORESCENS
TB_L_SU_ALV_ALVE 160 Continuous 0.35 ALOE VERA
AGAVE AMERICANA
TB_L_SU_AM_AGME 0,153,0 Continuous 0.35
MEDIOPICTA
TB_L_SU_AO_ADOB 255,31,199 Continuous 0.35 ADENUM OBESUM
TB_L_SU_AVR_AGVI 240 Continuous 0.35 AGAVE VICTORIA REGINAE
TB_L_SU_CNC_CEPE 50,143,126 Continuous 0.35 CEREUS PERUVIANIS
TB_L_SU_EBS_EUBA 122,250,148 Continuous 0.35 EUPHORBIA BALSAMIFERA

TB_L_SU_EGB_ECGR 200,197,50 Continuous 0.35 ECHINOCACTUS GRUSSONII

TB_L_SU_EM_EUMI 210 Continuous 0.35 EUPHORBIA MILII


TB_L_SU_EMS_EULA 159,208,184 Continuous 0.15 EUPHORBIA LACTEA

TB_L_SU_FMH_FUFO 165,155,44 Continuous 0.35 FURCRAEA FOETIDA

TB_L_SU_ST_SATR 92 Continuous 0.35 SANSEVIERIA TRIFASCIATA


TB_L_SU_YE_YUEL 146 Continuous 0.35 YUCCA ELEPHANTIPS

Page 115 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Layer Name Screen Colour Linetype Description
Line weight
TB_L_SU_YF_YUFI 142 Continuous 0.35 YUCCA FILAMENTOSA
TB_L_SU_YSB_YUAL 28,130,130 Continuous 0.35 YUCCA ALOFOLIA
TB_L_SU_YSD_YUGL 17,75,75 Continuous 0.35 YUCCA GLORIOSA
TB_L_THICK 10 Continuous 0.60 THICK OUTLINES
TB_L_THIN 11 Continuous 0.35 THIN LINES

TB_L_TIMBER Yellow Continuous 0.25 TIMBER SECTIONS IN DETAILS

TB_L_TOTEM Cyan Continuous 0.50 LANDSCAPE ARCHITECTURE


TB_L_TREENAMES Yellow Continuous 0.25 TAGGING FOR TREE SPECIES
TB_L_TREE_DECI Green Continuous 0.35 DECIDEOS TREES
ALL TYPE OF LARGE EVER
TB_L_TREE_LAEV Green Continuous 0.35
GREEN
ALL TYPE OF MEDIUM
TB_L_TREE_MEDE Green Continuous 0.35
DECEDIOUS TREES
ALL TYPE OF MEDIUM EVER
TB_L_TREE_MEEV Green Continuous 0.35
GREEN TREES
TB_L_TREE_PALM Green Continuous 0.35 PALMS TREES
TB_L_TREE_SHADE 252 Continuous 0.15 TREE SHADE INSIDE BLOCKS
TB_L_TREE_SMAL Green Continuous 0.35 SMALL TREES
TB_L_TREE_SUCC Green Continuous 0.35 SUCCULENTS
CENTER LINE (STEM) OF A
TB_L_TREE-CL 8 CENTER2 0.20
TREE
TB_L_TREES Green Continuous 0.35 TREES LARGE AND SMALL
ALL TYPE OF TEXT
TB_L_TXT Yellow Continuous 0.25
ANNOTATIONS
TB_L_VEGETATION 82 Continuous 0.35 VEGETATION/PLANT
TB_L_VI_ANL_ANLE 241 Continuous 0.35 ANTIGONON LEPTOPUS
TB_L_VI_CI_CLIN 120 Continuous 0.35 CLERODENDRUM INERME

Page 116 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – LANDSCAPING LAYERS (Continuation...)


Plotted
Layer Name Screen Colour Linetype Description
Line weight
TB_L_VI_CPR_CAPR 38,181,46 Continuous 0.35 CALOTROPIS PROCERA
TB_L_VI_LPY_LEPY 101,154,66 Continuous 0.35 LEPTADENIA PYROTECHNICA
TB_L_VI_MCA_MUC 148,71,121 Continuous 0.35 MUHLENBERGIA CAPILIARIES
A TOWN BEAUTIFICATION
TB_L_VINCA 96 Continuous 0.35
(LANDSCAPE) VINCA TREES
TB_L_VP White Continuous 0.25 VIEWPORT LINE
TB_L_WALKWAY Red Continuous 0.10 WALKWAY
TB_L_WALL Cyan Continuous 0.50 LANDSCAPE WALLS
2ND TYPE OF LANDSCAPE
TB_L_WALL1 Cyan Continuous 0.50
WALLS
TB_L_WATER_COOL 33 Continuous 0.35 WATER FOUNTAIN COOLER
ER WATER PROOFING ALL
TB_L_WATER PROOF 9 HIDDEN 0.15
STRICTURE
TB_L_WATER-EDGE Green Continuous 0.35 TREES LARGE AND SMALL

A.5.2 Town Beautification – Irrigation Layers

TOWN BEAUTIFICATION – IRRIGATION LAYERS


Plotted
Layer Name Screen Colour Linetype Description
Line weight
TB_I_100MM-PIPE Red DASHDOTX2 0.10 PIPELINE
TB_I_150MM-PIPE Red DASHED 0.10 PIPELINE
TB_I_200MM-PIPE Red DASHED 0.10 PIPELINE
TB_I_32MM-PIPE Cyan DASHDOT 0.50 PIPELINE

Page 117 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – IRRIGATION LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TB_I_40MM-PIPE Magenta Continuous 0.35 PIPELINE

TB_I_50MM-PIPE Blue DASHDOTX2 0.70 PIPELINE

TB_I_75MM-PIPE Green DASHDOTX2 0.35 PIPELINE


IRRIGATION ISOLATION VALVES,
TB_I_BLOCKS Green Continuous 0.35
AIR VALVES
FOR ALL BUBBLERS OF DIFFERENT
TB_I_BUBBLER 170 Continuous 0.35
TYPES WITH LATERAL LINES
TB_I_BUBBLER_ 1.5 INCH DIA UPVC PIPE FOR
210 IRR_1.5INCH 0.35
1.5INCH BUBBLER
TB_I_BUBBLER_ 1 INCH DIA UPVC PIPE FOR
210 IRR_1INCH 0.35
1INCH BUBBLER
TB_I_BUBBLER_ 2 INCH DIA UPVC PIPE FOR
210 IRR_2INCH 0.35
2INCH BUBBLER
TB_I_BUBBLER_ 3 INCH DIA UPVC PIPE FOR
210 IRR_3INCH 0.35
3INCH BUBBLER
TB_I_CABLE TAG Cyan Continuous 0.50 SOLENIOD VALVE CABLE TAG

TB_I_CLIMBERS Yellow Continuous 0.25 CLIMBERS


ALL TYPES OF COMMUNICATION
TB_I_COM White Continuous 0.25
EQUIPMENTS AND CABLES
CENTRAL IRRIGATION CONTROL
TB_I_COM_CICS 250 Continuous 0.15
SYSTEM
TB_I_COM_RADIO 250 Continuous 0.15 HAND HELD RADIO

TB_I_COM_WEAT
250 Continuous 0.15 WEATHER STATION
_STAT
TB_I_COMM_ ALL TYPES OF COMMUNICATION
112 IRR_12AWG 0.35
CABL EQUIPMENTS AND CABLES
TB_I_CONDUIT Cyan DASHED 0.50 CABLE CONDUIT PIPELINE

Page 118 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – IRRIGATION LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
ALL CONTROL SYSTEM WIRES,
TB_I_CONTROL White Continuous 0.25
CONTROLLERS, ATTRIBUTES
TB_I_CONTROL_ ALL CONTROL SYSTEM WIRES,
230 HIDDEN 0.35
CONDUIT CONTROLLERS, ATTRIBUTES
TB_I_CONTROL_PBOX 120 Continuous 0.35 PULL BOX
TB_I_CONTROL_TAG Yellow Continuous 0.25 TAGS FOR CONDUITS
TB_I_CONTROLLER White Continuous 0.25 ALL TYPE OF CONTROLLERS
TB_I_CONTROLLER
Green Continuous 0.35 IRRIGATION CONTROLLER ZONE
ZONE
TB_I_CONTROLLER_
Yellow Continuous 0.25 CONTROLLER TAG
TAG
TB_I_DESERT 11 Continuous 0.35 DESERT OF ALL TYPES
TB_I_DISTRIBUTION_ IRRIGATION DISTRIBUTION
Yellow Continuous 0.25
CHAMBER CHAMBER
FOR ALL DRIP LINES OF DIFFERENT
TB_I_DRIP 210 Continuous 0.35
TYPE WITH LATERAL LINES
1.5 INCH uPVC LETERAL LINE
TB_I_DRIP_1.5INCH 11 IRR_1.5INCH 0.35
DRIP
TB_I_DRIP_1INCH 11 IRR_1INCH 0.35 1 INCH uPVC LETERAL LINE DRIP
TB_I_DRIP_2INCH 11 IRR_2INCH 0.35 2 INCH uPVC LETERAL LINE DRIP
TB_I_DRIP_3INCH 11 IRR_3INCH 0.35 3 INCH uPVC LETERAL LINE DRIP
TB_I_DUCT White Continuous 0.25 IRRIGATION DUCT
TB_I_ENDCAP Blue Continuous 0.70 IRRIGATION END CAP
TB_I_EX PLAM 9 HIDDEN 0.15 EXISTING PALM IN SITE
TB_I_EX PLAM
Green Continuous 0.35 EXISTING PALM REMOVED
REMOVED

Page 119 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – IRRIGATION LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TB_I_EX TREE 9 HIDDEN 0.15 EXISTING TREE IN SITE
TB_I_FILTERS White Continuous 0.25 ALL TYPES OF FILTERS
TB_I_FLOW_BALANCE White Continuous 0.25 FLOW BALANCE
FOR ALL HEDGES OF DIFFERENT
TB_I_HEDGES Green Continuous 0.35
TYPE WITH LATERAL LINES
TB_I_IRRIGATION_PIPE Cyan Continuous 0.50 IRRIGATION PIPE
TB_I_LEVELS Yellow Continuous 0.25 SITE LEVELS
SPRINKLER IRRIGATION LAWN
TB_I_LH Cyan Continuous 0.50
HEAD
TB_I_MAINLINE Magenta DASHDOT2 0.35 ALL MAINLINE TYPES AND SIZES
TB_I_MAINLINE_2INCH 170 IRR_2INCH 0.35 2 INCH DIA uPVC
TB_I_MAINLINE_3INCH 170 IRR_3INCH 0.35 3 INCH DIA uPVC
TB_I_MAINLINE_4INCH 170 IRR_4INCH 0.35 4 INCH DIA uPVC
TB_I_MAST_VAL_TAG Yellow Continuous 0.25 MASTER VALVE FLOW TAG
TB_I_NOZZLE Green Continuous 0.35 SPRAY & SPRINKLER HEADS
TB_I_PALM RETAINED Red Continuous 0.10 EXISTING PALM TO BE RETAINED
IRRIGATION PVC-PE
TB_I_PE Green Continuous 0.35
CONNECTION
LOCATION OF BOOSTER PUMP
TB_I_PS White Continuous 0.25
STATION
TB_I_PULLBOX Cyan Continuous 0.50 IRRIGATION PULL BOXES
TB_I_RADIUS OF SPRAY & SPRINKLER RADIUS OF
251 Continuous 0.15
THROW THROW
TB_I_RAIN_SENSOR White Continuous 0.25 RAIN SENSOR
IRRIGATION REMOTE CONTROL
TB_I_RCVALVE Green Continuous 0.35
VALVE

Page 120 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – IRRIGATION LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TB_I_RCVALVE_BUBB 210 Continuous 0.35 SOLENOID VALVE FOR BUBBLER
TB_I_RCVALVE_DRIP 11 Continuous 0.35 SOLENOID VALVE FOR DRIP
TB_I_RCVALVE_ROTOR 70 Continuous 0.35 SOLENOID VALVE FOR ROTOR
SOLENOID VALVE FOR
TB_I_RCVALVE_SPRY 70 Continuous 0.35
SPRAYERS
TB_I_RCVALVE_TAG_ SOLENOID VALVE TAG FOR
Yellow Continuous 0.25
BUBB BUBBLER
TB_I_RCVALVE_TAG_
Yellow Continuous 0.25 SOLENOID VALVE TAG FOR DRIP
DRIP
TB_I_RCVALVE_TAG_ SOLENOID VALVE TAG FOR
Yellow Continuous 0.25
ROTOR ROTOR
TB_I_RCVALVE_TAG_ SOLENOID VALVE TAG FOR
Yellow Continuous 0.25
SPRY SPRAYERS
BLOCK FOR ALL ROTOR OF
TB_I_ROTOR Green Continuous 0.35 DIFFERENT TYPES WITH LATERAL
LINES
IRR_1.5INC 1.5 INCH uPVC LATERAL LINE
TB_I_ROTOR_1.5INCH 70 0.35
H ROTOR
1 INCH uPVC LATERAL LINE
TB_I_ROTOR_1INCH 70 IRR_1INCH 0.35
ROTOR
2 INCH uPVC LATERAL LINE
TB_I_ROTOR_2INCH 70 IRR_2INCH 0.35
ROTOR
3 INCH uPVC LATERAL LINE
TB_I_ROTOR_3INCH 70 IRR_3INCH 0.35
ROTOR
TB_I_SENSOR White Continuous 0.25 ALL TYPES OF SENSORS

FOR ALL SHRUBS OF DIFFERENT


TB_I_SHRUBS 94 Continuous 0.35
TYPE WITH LATERAL LINES

Page 121 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

TOWN BEAUTIFICATION – IRRIGATION LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
TB_I_SLEEVES Magenta Continuous 0.35 ALL SLEEVES TYPES AND SIZES
FOR ALL SPRAYERS OF
TB_I_SPRAYER Green Continuous 0.35 DIFFERENT TYPES WITH
LATERAL LINES
TB_I_SPRAYER_ 1.5 INCH uPVC LETERAL LINE
70 IRR_1.5INCH 0.35
1.5INCH SPRAYER
TB_I_SPRAYER_ 1 INCH uPVC LETERAL LINE
70 IRR_1INCH 0.35
1INCH SPRAYER
TB_I_SPRAYER_ 2 INCH uPVC LETERAL LINE
70 IRR_2INCH 0.35
2INCH SPRAYER
TB_I_SPRAYER_ 3 INCH uPVC LETERAL LINE
70 IRR_3INCH 0.35
3INCH SPRAYER
TB_I_SPRINKLER_PIPE Yellow HIDDEN2 0.25 SPRINKLER IRRIGATION PIPE
TB_I_TAKE OFF IRRIGATION MAINLINE
Green Continuous 0.35
POINT TAKEOFF POINT
TB_I_TEXT Green Continuous 0.35 IRRIGATION TEXT
TB_I_TREE REMOVED Green Continuous 0.35 EXISTING TREE REMOVED
TB_I_TREE RETAINED Red Continuous 0.10 EXISTING TREE TO BE RETAINED
SPRINKLER, DRIP & BUBBLER
TB_I_VALVE Green Continuous 0.35
VALVES
TB_I_VALVE SOLENOID VALVE COVERAGE
Green Continuous 0.35
BOUNDARY BOUNDARY
TB_I_VALVE TAG Green Continuous 0.35 SOLENOID VALVE TAG
TB_I_VALVE_ZONE 130 ( Phantom ) 0.35 SOLENOID VALVE ZONE
TB_I_VALVE_ZONE_ SOLENOID VALVE ZONE
Yellow Continuous 0.25
NUM NUMBER
ALL VALVES QCV, MASTER
TB_I_VALVES White Continuous 0.25
CONTROL, GATE AND VALVE
CHAMBERS

Page 122 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

A.6 UTILITIES LAYERS

A.6.1 Electricity

PROPOSED COMMERCIAL LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICE FIXTURES


SVC_PR_BANK 30 Continuous 0.35
(COMMERCIAL) : ATM AND SIMILAR
PROPOSED
FEATURES SERVICE FIXTURES
SVC_PR_BBDL 30 Continuous 0.35
(COMMERCIAL) : BILLBOARD
PROPOSED SERVICE FIXTURES
SVC_PR_OTHR White Continuous 0.25
(COMMERCIAL) : OTHER FEATURES
PROPOSED SERVICE FIXTURES
SVC_PR_POLE White Continuous 0.25
(COMMERCIAL) : POST / POLE
PROPOSED SERVICE FIXTURES
SVC_PR_SBDL White Continuous 0.25
(COMMERCIAL) : SIGNBOARD
PROPOSED SERVICE FIXTURES
SVC_PR_TEXT White Continuous 0.25
(COMMERCIAL) : ANNOTATION / TEXT

PROPOSED ELECTRICITY LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

ELE PROPOSED SERVICES FIXTURES


SVE_PR_ABDL 20 0.35
ABANDONED (ELECTRICITY) : ABANDONED LINE
SVE_PR_ PROPOSED SERVICES FIXTURES
20 Continuous 0.35
CONDUIT (ELECTRICITY) : ELECTRICITY CONDUIT
PROPOSED SERVICES FIXTURES
SVE_PR_DUCT 10 Continuous 0.60
(ELECTRICITY) : ELECTRICITY DUCT
SVE_PR_ERTH PROPOSED SERVICES FIXTURES
8 Continuous 0.20
_PIT (ELECTRICITY) : EARTH PIT
SVE_PR_FT_ PROPOSED SERVICES FIXTURES
30 Continuous 0.35
TEE (ELECTRICITY) : ELECTRICAL FITTING
TEE

Page 123 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED ELECTRICITY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES


SVE_PR_MHLL WHITE Continuous 0.25
(ELECTRICITY) : UTILITY/MANHOLE
PROPOSED SERVICES FIXTURES
SVE_PR_MNHL WHITE Continuous 0.25
(ELECTRICITY) : MANHOLE
PROPOSED SERVICES FIXTURES
SVE_PR_MRKR WHITE Continuous 0.25
(ELECTRICITY) : MARKER
PROPOSED SERVICES FIXTURES
ELE OVERHEAD
SVE_PR_OH_EHV 20 0.35 (ELECTRICITY) : EXTRA HIGH
EHV
VOLTAGE - OVERHEAD LINES
PROPOSED SERVICES FIXTURES
ELE OVERHEAD
SVE_PR_OH_HV 20 0.35 (ELECTRICITY) : HIGH VOLTAGE -
HV
OVERHEAD LINES
PROPOSED SERVICES FIXTURES
ELE OVERHEAD
SVE_PR_OH_LV 20 0.35 (ELECTRICITY) : EXTRA LOW
LV
VOLTAGE - OVERHEAD LINES
PROPOSED SERVICES FIXTURES
ELE OVERHEAD
SVE_PR_OH_MV 20 0.35 (ELECTRICITY) : MEDIUM VOLTAGE -
MV
OVERHEAD LINES
PROPOSED SERVICES FIXTURES
SVE_PR_OTHR WHITE Continuous 0.25
(ELECTRICITY) : OTHER
PROPOSED SERVICES FIXTURES
ELE PILOT
SVE_PR_PLT_CBL WHITE 0.25 (ELECTRICITY) : ELECTRICAL PILOT
CABLE
CABLE
ELE PILOT PROPOSED SERVICES FIXTURES
SVE_PR_PLT_CBL
20 CABLE 0.35 (ELECTRICITY) : ABANDONED
_ABDL
ABANDONED ELECTRICAL PILOT CABLE
PROPOSED SERVICES FIXTURES
SVE_PR_POLE WHITE Continuous 0.25
(ELECTRICITY) : POST/POLE

Page 124 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED ELECTRICITY LAYERS (Continuation...)


Plotted
Screen
Layer Name Linetype Line Description
Colour
weight

PROPOSED SERVICES FIXTURES


SVE_PR_PYLN WHITE Continuous 0.25
(ELECTRICITY) : PYLON
PROPOSED SERVICES FIXTURES
SVE_PR_SBOX WHITE Continuous 0.25
(ELECTRICITY) : SERVICE BOX
PROPOSED SERVICES FIXTURES
SVE_PR_SJNT GREEN Continuous 0.35 (ELECTRICITY) : ELECTRICAL
STRAIGHT JOINT
PROPOSED SERVICES FIXTURES
SVE_PR_SSTL YELLOW Continuous 0.25
(ELECTRICITY) : SUBSTATION
PROPOSED SERVICES FIXTURES
SVE_PR_TEXT WHITE Continuous 0.25
(ELECTRICITY) : ANNOTATION / TEXT
PROPOSED SERVICES FIXTURES
SVE_PR_TOWER 40 Continuous 0.35
(ELECTRICITY) : ELECTRICITY TOWER
PROPOSED SERVICES FIXTURES
SVE_PR_TRANSF CYAN Continuous 0.50
(ELECTRICITY) : TRANSFORMER
PROPOSED SERVICES FIXTURES
SVE_PR_UG_ ELE UNDERGROUND
20 0.35 (ELECTRICITY) : EXTRA HIGH
EHV EHV
VOLTAGE - UNDERGROUND LINES
PROPOSED SERVICES FIXTURES
ELE UNDERGROUND
SVE_PR_UG_HV 20 0.35 (ELECTRICITY) : HIGH VOLTAGE -
HV
UNDERGROUND LINES
PROPOSED SERVICES FIXTURES
ELE UNDERGROUND
SVE_PR_UG_LV 20 0.35 (ELECTRICITY) : LOW VOLTAGE -
LV
UNDERGROUND LINES
PROPOSED SERVICES FIXTURES
ELE UNDERGROUND
SVE_PR_UG_MV 20 0.35 (ELECTRICITY) : MEDIUM VOLTAGE -
MV
UNDERGROUND LINES

Page 125 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED OIL & GAS LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES (OIL


SVO_PR_BNDL 171 Continuous 0.35
AND GAS) : BUND
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_DUCT 241 Continuous 0.35
AND GAS) : OIL / GAS DUCT
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_GAS 90 GAS PIPE 0.35
AND GAS) : GAS PIPE LINE
SVO_PR_GAS_ GAS PIPE PROPOSED SERVICES FIXTURES (OIL
90 0.35
ABDL ABANDONED AND GAS) : ABANDONED GAS PIPE LINE
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_GVLV 171 Continuous 0.35
AND GAS) : GAS VALVE
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_MNHL 171 Continuous 0.35
AND GAS) : MANHOLE
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_MRKR 171 Continuous 0.35
AND GAS) : MARKER
SVO_PR_OIL_ OIL PIPE PROPOSED SERVICES FIXTURES (OIL
46 0.35
ABDL ABANDONED AND GAS) : ABANDONED OIL PIPE LINE
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_OTHR 171 Continuous 0.35
AND GAS) : OTHER
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_PIPE 46 OIL PIPE 0.35
AND GAS) : PIPE LINE
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_POLE 171 Continuous 0.35
AND GAS) : POST / POLE
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_PUMP 171 Continuous 0.35
AND GAS) : PUMP
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_SBOX 171 Continuous 0.35
AND GAS) : SERVICE BOX
PROPOSED SERVICES FIXTURES (OIL
SVO_PR_TANK 171 Continuous 0.35
AND GAS) : TANK

Page 126 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED ELECTRICITY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES (OIL


SVO_PR_TEXT WHITE Continuous 0.25
AND GAS) : ANNOTATION / TEXT

PROPOSED TELECOM LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES


SVT_PR_ACCOR 20 DASHED2 0.35
(TELECOMS) : AERIAL CABLE CORRIDOR
PROPOSED SERVICES FIXTURES (QTEL /
SVT_PR_ARFL 30 QAF 0.35
TELECOMS) : QATAR ARMED FORCE LINE
PROPOSED SERVICES FIXTURES
SVT_PR_ARFL_ QAF
30 0.35 (TELECOMS) : ABANDONED QATAR
ABDL ABANDONED
ARMED FORCE LINE
PROPOSED SERVICES FIXTURES
SVT_PR_BCCOR 30 Continuous 0.35
(TELECOMS) :BURRIED CABLE CORRIDOR
PROPOSED SERVICES FIXTURES
SVT_PR_BOOT 30 Continuous 0.35
(TELECOMS) : TELEPHONE BOOTH
PROPOSED SERVICES FIXTURES
SVT_PR_CABNT 30 Continuous 0.35
(TELECOMS) : CABINET
PROPOSED SERVICES FIXTURES
SVT_PR_COMMS 30 COMMS 0.35 (TELECOMS) : COMMUNICATION LINE
(GENERAL)
PROPOSED SERVICES FIXTURES
SVT_PR_COMMS COMMS
30 0.35 (TELECOMS) : ABANDONED
_ABDL ABANDONED
COMMUNICATION LINE (GENERAL)

Page 127 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TELECOM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES


SVT_PR_DIST_PT 30 Continuous 0.35
(TELECOMS) : DISTRIBUTION POINT
PROPOSED SERVICES FIXTURES
SVT_PR_OTHR 30 Continuous 0.35
(TELECOMS) : OTHER
PROPOSED SERVICES FIXTURES
SVT_PR_DUCT_D54 10 Continuous 0.60
(TELECOMS) : DUCT TYPE D54
PROPOSED SERVICES FIXTURES
SVT_PR_DUCT_D54-
160 DASHDOT2 0.35 (TELECOMS) : DUCT TYPE D54 - 4
4 WAY
DUCT WAYS
PROPOSED SERVICES FIXTURES
SVT_PR_DUCT_D54-
200 DASHDOT2 0.35 (TELECOMS) : DUCT TYPE D54 - 6
6 WAY
DUCT WAYS
PROPOSED SERVICES FIXTURES
SVT_PR_DUCT_D54-
240 DASHDOT2 0.35 (TELECOMS) : DUCT TYPE D54 - 9
9 WAY
DUCT WAYS
PROPOSED SERVICES FIXTURES
SVT_PR_DUCT_D54-
240 Continuous 0.35 (TELECOMS) : DUCT TYPE D54 -
RC
REINFORCED CONCRETE DUCTS
PROPOSED SERVICES FIXTURES
SVT_PR_DUCT_D56 30 Continuous 0.35 (TELECOMS) : DUCT TYPE D56 - FOR
DISTRIBUTION CONNECTION
PROPOSED SERVICES FIXTURES
SVT_PR_DUCT_D56-
160 DASHDOT2 0.35 (TELECOMS) : DUCT TYPE D56 - 4
4 WAY
DUCT WAYS
PROPOSED SERVICES FIXTURES
SVT_PR_ENDCAP 30 Continuous 0.35
(TELECOMS) : ENDCAP

Page 128 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TELECOM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES (TELECOMS) :


SVT_PR_EXCH 30 Continuous 0.35 CENTRAL OFFICE (RLU OR EXCHANGE
BUILDING)
SVT_PR_JBOX PROPOSED SERVICES FIXTURES (TELECOMS) :
40 Continuous 0.35
_JRC12 JUNCTION BOX CHAMBER TYPE JRC12

SVT_PR_JBOX PROPOSED SERVICES FIXTURES (TELECOMS) :


240 Continuous 0.35
_JRC14 JUNCTION BOX CHAMBER TYPE JRC14

PROPOSED SERVICES FIXTURES (TELECOMS) :


SVT_PR_JBOX
190 Continuous 0.35 JUNCTION BOX CHAMBER TYPE JRC14-WITH
_JRC14-E
EXTRA DEPTH
SVT_PR_JBOX PROPOSED SERVICES FIXTURES (TELECOMS) :
Green Continuous 0.35
_JRC2 JUNCTION BOX CHAMBER TYPE JRC2
SVT_PR_JBOX PROPOSED SERVICES FIXTURES (TELECOMS) :
190 Continuous 0.35
_JRC4 JUNCTION BOX CHAMBER TYPE JRC4
SVT_PR_MH_ PROPOSED SERVICES FIXTURES (TELECOMS) :
190 Continuous 0.35
MRT2 MANHOLE TYPE MRT2
SVT_PR_MH_ PROPOSED SERVICES FIXTURES (TELECOMS) :
150 Continuous 0.35
MRT2-E MANHOLE TYPE MRT2 - EXTRA DEPTH
SVT_PR_MH_ PROPOSED SERVICES FIXTURES (TELECOMS) :
40 Continuous 0.35
MRT4 MANHOLE TYPE MRT4
SVT_PR_MH_ PROPOSED SERVICES FIXTURES (TELECOMS) :
180 Continuous 0.35
MRT4-E MANHOLE TYPE MRT4 - EXTRA DEPTH
SVT_PR_MH_ PROPOSED SERVICES FIXTURES (TELECOMS) :
240 Continuous 0.35
MRT9 MANHOLE TYPE MRT9

SVT_PR_MH_ PROPOSED SERVICES FIXTURES (TELECOMS) :


20 Continuous 0.35
MRT9-E MANHOLE TYPE MRT9 - EXTRA DEPTH

Page 129 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TELECOM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES


SVT_PR_MNHL 30 Continuous 0.35
(TELECOMS) : MANHOLE
PROPOSED SERVICES FIXTURES
SVT_PR_MRKR 30 Continuous 0.35
(TELECOMS) : SERVICE MARKER
PROPOSED SERVICES FIXTURES
TEL OVERHEAD
SVT_PR_OHLN 20 0.35 (TELECOMS) : TELECOM
LINE
OVERHEAD LINE
PROPOSED SERVICES FIXTURES
SVT_PR_OHLN_ TEL OVERHEAD
20 0.35 (TELECOMS) : ABANDONED
ABDL LINE ABANDONED
TELECOM OVERHEAD LINE
PROPOSED SERVICES FIXTURES
SVT_PR_OTHR 30 Continuous 0.35
(TELECOMS) : OTHER
PROPOSED SERVICES FIXTURES
SVT_PR_POLE 30 Continuous 0.35
(TELECOMS) : POST / POLE
PROPOSED SERVICES FIXTURES
SVT_PR_QNBN 30 QNB 0.35 (TELECOMS) : QATAR NATIONAL
BROADBAND LINE
PROPOSED SERVICES FIXTURES
SVT_PR_QNBN_
30 QNB ABANDONED 0.35 (TELECOMS) : ABANDONED
ABDL
QATAR NATIONAL BROADBAND
PROPOSED
LINE SERVICES FIXTURES
SVT_PR_QTL 30 OOR 0.35
(TELECOMS) : OOREDOO LINE
PROPOSED SERVICES FIXTURES
SVT_PR_QTL_
30 OOR ABANDONED 0.35 (TELECOMS) : ABANDONED
ABDL
OOREDOO LINE
PROPOSED SERVICES FIXTURES
SVT_PR_SBOX 30 Continuous 0.35
(TELECOMS) : SERVICE BOX

Page 130 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TELECOM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES


SVT_PR_SCCOR 30 Continuous 0.35 (TELECOMS) : SURFACE CABLE
CORRIDOR
PROPOSED SERVICES FIXTURES
SVT_PR_SSD 30 SSD 0.35 (TELECOMS) : SECURITY SYSTEMS
DEPARTMENT LINE
PROPOSED SERVICES FIXTURES
SVT_PR_SSD_ SSD
30 0.35 (TELECOMS) : ABANDONED
ABDL ABANDONED
SECURITY SYSTEMS DEPARTMENT
PROPOSED
LINE SERVICES FIXTURES
SVT_PR_SSTA 30 Continuous 0.35
(TELECOMS) : SUBSTATION
PROPOSED SERVICES FIXTURES
SVT_PR_TEXT YELLOW Continuous 0.25
(TELECOMS) : ANNOTATION / TEXT
PROPOSED SERVICES FIXTURES
SVT_PR_TOWR 30 Continuous 0.35
(TELECOMS) : TOWER
PROPOSED SERVICES FIXTURES
SVT_PR_TRAN_
10 DASHDOT 0.60 (TELECOMS) : TRANSMISSION
NTWK
NETWORK
SVT_PR_TRAN_ PROPOSED SERVICES FIXTURES
30 Continuous 0.35
PT (TELECOMS) : TRANSMISSION POINT
PROPOSED SERVICES FIXTURES
SVT_PR_UDCOR 30 Continuous 0.35 (TELECOMS) : UNDER GROUND
DUCT CORRIDOR
PROPOSED SERVICES FIXTURES
SVT_PR_UGLN 30 Continuous 0.35
(TELECOMS) : UNDER GROUND LINE
PROPOSED SERVICES FIXTURES
SVT_PR_VOD 30 VOD 0.35
(TELECOMS) : VODAFONE LINE

Page 131 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED TELECOM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES


SVT_PR_VOD_ VOD
30 0.35 (TELECOMS) : ABANDONED
ABDL ABANDONED
VODAFONE LINE

PROPOSED WATER LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

WATER PROPOSED SERVICES FIXTURES


SVW_PR_ABDL 142 0.35
ABANDONED (WATER) : ABANDONED WATER LINE
PROPOSED SERVICES FIXTURES
SVW_PR_BNDL 130 Continuous 0.35
(WATER) : BUND
PROPOSED SERVICES FIXTURES
SVW_PR_CLR_ PT 200 Continuous 0.35
(WATER) : CHLORINATION POINT
PROPOSED SERVICES FIXTURES
SVW_PR_CPRT 200 Continuous 0.35
(WATER) : CASING PROTECTION
SVW_PR_ PROPOSED SERVICES FIXTURES
142 CHILLED WATER 0.35
CWMAIN (WATER) : CHILLED WATER MAIN
SVW_PR_ CHILLED WATER PROPOSED SERVICES FIXTURES
142 0.35
CWMAIN_ABDL ABANDONED (WATER) : ABANDONED CHILLED
PROPOSED SERVICES FIXTURES
WATER MAIN
SVW_PR_DRKL 130 Continuous 0.35
(WATER) : DRINKING AREA
PROPOSED SERVICES FIXTURES
SVW_PR_DUCT 30 Continuous 0.35
(WATER) : DUCT
SVW_PR_FT_ PROPOSED SERVICES FIXTURES
150 Continuous 0.35
ADPTR (WATER) : FITTING ADAPTER

Page 132 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED WATER LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES


SVW_PR_FT_ BEND 150 Continuous 0.35
(WATER) : FITTING BEND

SVW_PR_FT_ PROPOSED SERVICES FIXTURES


150 Continuous 0.35
ENDCAP (WATER) : FITTING ENDCAP

PROPOSED SERVICES FIXTURES


SVW_PR_FT_ RDCR 150 Continuous 0.35
(WATER) : FITTING REDUCER
PROPOSED SERVICES FIXTURES
SVW_PR_FT_ TEE 150 Continuous 0.35
(WATER) : FITTING TEE
PROPOSED SERVICES FIXTURES
SVW_PR_GCHNL 200 Continuous 0.35
(WATER) : GRAVITY CHANNEL
PROPOSED SERVICES FIXTURES
SVW_PR_GPIPE 200 Continuous 0.35
(WATER) : GRAVITY PIPE
PROPOSED SERVICES FIXTURES
SVW_PR_HYDR 200 Continuous 0.35
(WATER) : HYDRANT
PROPOSED SERVICES FIXTURES
SVW_PR_METER 200 Continuous 0.35
(WATER) : METER
PROPOSED SERVICES FIXTURES
SVW_PR_MNHL 170 Continuous 0.35
(WATER) : MANHOLE
PROPOSED SERVICES FIXTURES
SVW_PR_MRKR 130 Continuous 0.35
(WATER) : MARKER
PROPOSED SERVICES FIXTURES
SVW_PR_PUMP 200 Continuous 0.35
(WATER) : PUMP
PROPOSED SERVICES FIXTURES
SVW_PR_SCOCK 200 Continuous 0.35
(WATER) : STOPCOCK
PROPOSED SERVICES FIXTURES
SVW_PR_SCSR 200 Continuous 0.35
(WATER) : SCADA SENSOR
PROPOSED SERVICES FIXTURES
SVW_PR_SMETER 200 Continuous 0.35
(WATER) : SERVICE METER

Page 133 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED WATER LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

PROPOSED SERVICES FIXTURES


SVW_PR_SPIPE 200 Continuous 0.35
(WATER) : SERVICE PIPE

PROPOSED SERVICES FIXTURES


SVW_PR_STRG_PT 200 Continuous 0.35
(WATER) : STORAGE POINT

PROPOSED SERVICES FIXTURES


SVW_PR_TANK 230 Continuous 0.35
(WATER) : TANK
SVW_PR_TANK_FIL_ PROPOSED SERVICES FIXTURES
200 Continuous 0.35
PT (WATER) : TANKER FILLING POINT
PROPOSED SERVICES FIXTURES
SVW_PR_TEXT White Continuous 0.25
(WATER) : ANNOTATION / TEXT
PROPOSED SERVICES FIXTURES
(WATER) : WATER SLUICE VALVE,
SVW_PR_VALV 160 Continuous 0.35 AIR VALVE, FLOW CONTROL VALVE,
SERVICE VALVE, SYSTEM VALVE,
VALVE
PROPOSED SERVICES FIXTURES
SVW_PR_WELL 200 Continuous 0.35
(WATER) : WELL
PROPOSED SERVICES FIXTURES
SVW_PR_WFAC 200 Continuous 0.35
(WATER) : WATER FACILITY
PROPOSED SERVICES FIXTURES
SVW_PR_WMAIN 142 WATER 0.35
(WATER) : WATER MAIN
PROPOSED SERVICES FIXTURES
SVW_PR_WSCON 200 Continuous 0.35 (WATER) : WATER SERVICE
CONNECTION

Page 134 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

A.6.2 On-going Works

ONGOING WORKS LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

WRK_CONL WHITE Continuous 0.25 ON-GOING CONSTRUCTION WORKS

WRK_EXVL WHITE Continuous 0.25 EXCAVATION WORKS

WRK_FILL WHITE Continuous 0.25 FILLING MATERIAL LIMITS

ON-GOING WORKS : ANNOTATION /


WRK_TEXT WHITE Continuous 0.25
TEXT

EXISTING COMMERCIAL LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SERVICE FIXTURES


SVC_EX_BANK 253 Continuous 0.15
(COMMERCIAL) : ATM AND SIMILAR
EXISTING
FEATURESSERVICE FIXTURES
SVC_EX_BBDL 253 Continuous 0.15
(COMMERCIAL) : BILLBOARD
EXISTING SERVICE FIXTURES
SVC_EX_OTHR 253 Continuous 0.15
(COMMERCIAL) : OTHER FEATURES
EXISTING SERVICE FIXTURES
SVC_EX_POLE 253 Continuous 0.15
(COMMERCIAL) : POST / POLE
EXISTING SERVICE FIXTURES
SVC_EX_SBDL 253 Continuous 0.15
(COMMERCIAL) : SIGNBOARD
EXISTING SERVICE FIXTURES
SVC_EX_TEXT 253 Continuous 0.15
(COMMERCIAL) : ANNOTATION / TEXT

Page 135 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING ELECTRICITY LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

ELE EXISTING SERVICES FIXTURES


SVE_EX_ABDL 253 0.15
ABANDONED (ELECTRICITY) : ABANDONED LINE
SVE_EX_ EXISTING SERVICES FIXTURES
253 Continuous 0.15
CONDUIT (ELECTRICITY) : ELECTRICITY CONDUIT
EXISTING SERVICES FIXTURES
SVE_EX_DUCT 253 Continuous 0.15
(ELECTRICITY) : ELECTRICITY DUCT
EXISTING SERVICES FIXTURES
SVE_EX_ERTH_PIT 253 Continuous 0.15
(ELECTRICITY) : EARTH PIT
EXISTING SERVICES FIXTURES
SVE_EX_FT_ TEE 253 Continuous 0.15
(ELECTRICITY) : ELECTRICAL FITTING
EXISTING
TEE SERVICES FIXTURES
SVE_EX_MHLL 253 Continuous 0.15
(ELECTRICITY) : UTILITY/MANHOLE
EXISTING SERVICES FIXTURES
SVE_EX_MNHL 253 Continuous 0.15
(ELECTRICITY) : MANHOLE
EXISTING SERVICES FIXTURES
SVE_EX_MRKR 253 Continuous 0.15
(ELECTRICITY) : MARKER
ELE EXISTING SERVICES FIXTURES
SVE_EX_OH_EHV 253 OVERHEAD 0.15 (ELECTRICITY) : EXTRA HIGH VOLTAGE
EHV - OVERHEAD LINES
ELE EXISTING SERVICES FIXTURES
SVE_EX_OH_HV 253 OVERHEAD 0.15 (ELECTRICITY) : HIGH VOLTAGE -
HV OVERHEAD LINES
EXISTING SERVICES FIXTURES
ELE
SVE_EX_OH_LV 253 0.15 (ELECTRICITY) : EXTRA LOW VOLTAGE
OVERHEAD LV
- OVERHEAD LINES
ELE EXISTING SERVICES FIXTURES
SVE_EX_OH_MV 253 OVERHEAD 0.15 (ELECTRICITY) : MEDIUM VOLTAGE -
MV OVERHEAD LINES

Page 136 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING ELECTRICITY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SERVICES FIXTURES


SVE_EX_OTHR 253 Continuous 0.15
(ELECTRICITY) : OTHER
EXISTING SERVICES FIXTURES
ELE PILOT
SVE_EX_PLT_CBL 253 0.15 (ELECTRICITY) : ELECTRICAL PILOT
CABLE
CABLE
ELE PILOT EXISTING SERVICES FIXTURES
SVE_EX_PLT_CBL_
253 CABLE 0.15 (ELECTRICITY) : ABANDONED
ABDL
ABANDONED ELECTRICAL PILOT CABLE
EXISTING SERVICES FIXTURES
SVE_EX_POLE 253 Continuous 0.15
(ELECTRICITY) : POST/POLE
EXISTING SERVICES FIXTURES
SVE_EX_PYLN 253 Continuous 0.15
(ELECTRICITY) : PYLON
EXISTING SERVICES FIXTURES
SVE_EX_SBOX 253 Continuous 0.15
(ELECTRICITY) : SERVICE BOX
EXISTING SERVICES FIXTURES
SVE_EX_SJNT 253 Continuous 0.15 (ELECTRICITY) : ELECTRICAL
STRAIGHT JOINT
EXISTING SERVICES FIXTURES
SVE_EX_SSTL 253 Continuous 0.15
(ELECTRICITY) : SUBSTATION
EXISTING SERVICES FIXTURES
SVE_EX_TEXT 253 Continuous 0.15
(ELECTRICITY) : ANNOTATION / TEXT
EXISTING SERVICES FIXTURES
SVE_EX_TOWER 253 Continuous 0.15
(ELECTRICITY) : ELECTRICITY TOWER
EXISTING SERVICES FIXTURES
SVE_EX_TRANSF 253 Continuous 0.15
(ELECTRICITY) : TRANSFORMER
ELE EXISTING SERVICES FIXTURES
SVE_EX_UG_ EHV 253 UNDERGROUND 0.15 (ELECTRICITY) : EXTRA HIGH
EHV VOLTAGE - UNDERGROUND LINES

Page 137 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING ELECTRICITY LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SERVICES FIXTURES


ELE UNDERGROUND
SVE_EX_UG_HV 253 0.15 (ELECTRICITY) : HIGH VOLTAGE -
HV
UNDERGROUND LINES
EXISTING SERVICES FIXTURES
ELE UNDERGROUND
SVE_EX_UG_LV 253 0.15 (ELECTRICITY) : LOW VOLTAGE -
LV
UNDERGROUND LINES
EXISTING SERVICES FIXTURES
ELE UNDERGROUND
SVE_EX_UG_MV 253 0.15 (ELECTRICITY) : MEDIUM
MV
VOLTAGE - UNDERGROUND LINES

EXISTING OIL & GAS LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SERVICES FIXTURES (OIL AND


SVO_EX_BNDL 253 Continuous 0.15
GAS) : BUND
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_DUCT 253 Continuous 0.15
GAS) : OIL / GAS DUCT
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_GAS 253 GAS PIPE 0.15
GAS) : GAS PIPE LINE
SVO_EX_GAS_ GAS PIPE EXISTING SERVICES FIXTURES (OIL AND
253 0.15
ABDL ABANDONED GAS) : ABANDONED GAS PIPE LINE
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_GVLV 253 Continuous 0.15
GAS) : GAS VALVE
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_MNHL 253 Continuous 0.15
GAS) : MANHOLE
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_MRKR 253 Continuous 0.15
GAS) : MARKER

Page 138 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING OIL & GAS LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

SVO_EX_OIL_ OIL PIPE EXISTING SERVICES FIXTURES (OIL AND


253 0.15
ABDL ABANDONED GAS) : ABANDONED OIL PIPE LINE
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_OTHR 253 Continuous 0.15
GAS) : OTHER
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_PIPE 253 OIL PIPE 0.15
GAS) : PIPE LINE
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_POLE 253 Continuous 0.15
GAS) : POST / POLE
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_PUMP 253 Continuous 0.15
GAS) : PUMP
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_SBOX 253 Continuous 0.15
GAS) : SERVICE BOX
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_TANK 253 Continuous 0.15
GAS) : TANK
EXISTING SERVICES FIXTURES (OIL AND
SVO_EX_TEXT 253 Continuous 0.15
GAS) : ANNOTATION / TEXT

EXISTING TELECOMMUNICATIONS LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SERVICES FIXTURES


SVT_EX_ACCOR 253 DASHED2 0.15
(TELECOMS) : AERIAL CABLE CORRIDOR
EXISTING SERVICES FIXTURES (QTEL /
SVT_EX_ARFL 253 QAF 0.15
TELECOMS) : QATAR ARMED FORCE LINE
EXISTING SERVICES FIXTURES
SVT_EX_ARFL_ QAF
253 0.15 (TELECOMS) : ABANDONED QATAR
ABDL ABANDONED
ARMED FORCE LINE

Page 139 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TELECOMMUNICATIONS LAYERS (Continuation...)


Plotted
Screen
Layer Name Linetype Line Description
Colour
weight

EXISTING SERVICES FIXTURES


SVT_EX_ARFL_ QAF
253 0.15 (TELECOMS) : ABANDONED QATAR
ABDL ABANDONED
ARMED FORCE LINE
EXISTING SERVICES FIXTURES
SVT_EX_BCCOR 253 Continuous 0.15
(TELECOMS) :BURRIED CABLE CORRIDOR
EXISTING SERVICES FIXTURES
SVT_EX_BOOT 253 Continuous 0.15
(TELECOMS) : TELEPHONE BOOTH
EXISTING SERVICES FIXTURES
SVT_EX_CABNT 253 Continuous 0.15
(TELECOMS) : CABINET
EXISTING SERVICES FIXTURES
SVT_EX_COMMS 253 COMMS 0.15 (TELECOMS) : COMMUNICATION LINE
(GENERAL)
EXISTING SERVICES FIXTURES
SVT_EX_COMMS COMMS
253 0.15 (TELECOMS) : ABANDONED
_ABDL ABANDONED
COMMUNICATION LINE (GENERAL)
EXISTING SERVICES FIXTURES
SVT_EX_DIST_PT 253 Continuous 0.15
(TELECOMS) : DISTRIBUTION POINT
EXISTING SERVICES FIXTURES
SVT_EX_OTHR 253 Continuous 0.15
(TELECOMS) : OTHER
SVT_EX_DUCT_ EXISTING SERVICES FIXTURES
253 Continuous 0.15
D54 (TELECOMS) : DUCT TYPE D54
EXISTING SERVICES FIXTURES
SVT_EX_DUCT_
253 DASHDOT2 0.15 (TELECOMS) : DUCT TYPE D54 - 4 DUCT
D54-4 WAY
WAYS
EXISTING SERVICES FIXTURES
SVT_EX_DUCT_D
253 DASHDOT2 0.15 (TELECOMS) : DUCT TYPE D54 - 6 DUCT
54-6 WAY
WAYS

Page 140 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TELECOMMUNICATIONS LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

SVT_EX_DUCT_ EXISTING SERVICES FIXTURES (TELECOMS) :


253 DASHDOT2 0.15
D54- 9 WAY DUCT TYPE D54 - 9 DUCT WAYS
EXISTING SERVICES FIXTURES (TELECOMS) :
SVT_EX_DUCT_
253 Continuous 0.15 DUCT TYPE D54 - REINFORCED CONCRETE
D54-RC
DUCTS
EXISTING SERVICES FIXTURES (TELECOMS) :
SVT_EX_DUCT_
253 Continuous 0.15 DUCT TYPE D56 - FOR DISTRIBUTION
D56
CONNECTION
SVT_EX_DUCT_ EXISTING SERVICES FIXTURES (TELECOMS) :
253 DASHDOT2 0.15
D56-4 WAY DUCT TYPE D56 - 4 DUCT WAYS

SVT_EX_ EXISTING SERVICES FIXTURES (TELECOMS) :


253 Continuous 0.15
ENDCAP ENDCAP
EXISTING SERVICES FIXTURES (TELECOMS) :
SVT_EX_EXCH 253 Continuous 0.15 CENTRAL OFFICE (RLU OR EXCHANGE
BUILDING)
SVT_EX_JBOX_ EXISTING SERVICES FIXTURES (TELECOMS) :
253 Continuous 0.15
JRC12 JUNCTION BOX CHAMBER TYPE JRC12

SVT_EX_JBOX_ EXISTING SERVICES FIXTURES (TELECOMS) :


253 Continuous 0.15
JRC14 JUNCTION BOX CHAMBER TYPE JRC14

EXISTING SERVICES FIXTURES (TELECOMS) :


SVT_EX_JBOX_
253 Continuous 0.15 JUNCTION BOX CHAMBER TYPE JRC14-WITH
JRC14-E
EXTRA DEPTH
SVT_EX_JBOX_ EXISTING SERVICES FIXTURES (TELECOMS) :
253 Continuous 0.15
JRC2 JUNCTION BOX CHAMBER TYPE JRC2
SVT_EX_JBOX_ EXISTING SERVICES FIXTURES (TELECOMS) :
253 Continuous 0.15
JRC4 JUNCTION BOX CHAMBER TYPE JRC4

Page 141 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TELECOMMUNICATIONS LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

SVT_EX_MH_ EXISTING SERVICES FIXTURES (TELECOMS)


253 Continuous 0.15
MRT2 : MANHOLE TYPE MRT2
SVT_EX_MH_ EXISTING SERVICES FIXTURES (TELECOMS)
253 Continuous 0.15
MRT2-E : MANHOLE TYPE MRT2 - EXTRA DEPTH
SVT_EX_MH_ EXISTING SERVICES FIXTURES (TELECOMS)
253 Continuous 0.15
MRT4 : MANHOLE TYPE MRT4
SVT_EX_MH_ EXISTING SERVICES FIXTURES (TELECOMS)
253 Continuous 0.15
MRT4-E : MANHOLE TYPE MRT4 - EXTRA DEPTH
SVT_EX_MH_ EXISTING SERVICES FIXTURES (TELECOMS)
253 Continuous 0.15
MRT9 : MANHOLE TYPE MRT9

SVT_EX_MH_ EXISTING SERVICES FIXTURES (TELECOMS)


253 Continuous 0.15
MRT9-E : MANHOLE TYPE MRT9 - EXTRA DEPTH

EXISTING SERVICES FIXTURES (TELECOMS)


SVT_EX_MNHL 253 Continuous 0.15
: MANHOLE
EXISTING SERVICES FIXTURES (TELECOMS)
SVT_EX_MRKR 253 Continuous 0.15
: SERVICE MARKER
TEL OVERHEAD EXISTING SERVICES FIXTURES (TELECOMS)
SVT_EX_OHLN 253 0.15
LINE : TELECOM OVERHEAD LINE
TEL OVERHEAD
SVT_EX_OHLN_ EXISTING SERVICES FIXTURES (TELECOMS)
253 LINE 0.15
ABDL : ABANDONED TELECOM OVERHEAD LINE
ABANDONED
EXISTING SERVICES FIXTURES (TELECOMS)
SVT_EX_OTHR 253 Continuous 0.15
: OTHER
EXISTING SERVICES FIXTURES (TELECOMS)
SVT_EX_POLE 253 Continuous 0.15
: POST / POLE

Page 142 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TELECOMMUNICATIONS LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SERVICES FIXTURES


SVT_EX_QNBN 253 QNB 0.15 (TELECOMS) : QATAR NATIONAL
BROADBAND LINE
EXISTING SERVICES FIXTURES
SVT_EX_QNBN_ QNB
253 0.15 (TELECOMS) : ABANDONED QATAR
ABDL ABANDONED
NATIONAL BROADBAND LINE
EXISTING SERVICES FIXTURES
SVT_EX_QTL 253 OOR 0.15
(TELECOMS) : OOREDOO LINE
EXISTING SERVICES FIXTURES
SVT_EX_QTL_ OOR
253 0.15 (TELECOMS) : ABANDONED
ABDL ABANDONED
OOREDOO LINE
EXISTING SERVICES FIXTURES
SVT_EX_SBOX 253 Continuous 0.15
(TELECOMS) : SERVICE BOX
EXISTING SERVICES FIXTURES
SVT_EX_SCCOR 253 Continuous 0.15 (TELECOMS) : SURFACE CABLE
CORRIDOR
EXISTING SERVICES FIXTURES
SVT_EX_SSD 253 SSD 0.15 (TELECOMS) : SECURITY SYSTEMS
DEPARTMENT LINE
EXISTING SERVICES FIXTURES
SVT_EX_SSD_ SSD
253 0.15 (TELECOMS) : ABANDONED
ABDL ABANDONED
SECURITY SYSTEMS DEPARTMENT
EXISTING
LINE SERVICES FIXTURES
SVT_EX_SSTA 253 Continuous 0.15
(TELECOMS) : SUBSTATION
EXISTING SERVICES FIXTURES
SVT_EX_TEXT 253 Continuous 0.15
(TELECOMS) : ANNOTATION / TEXT
EXISTING SERVICES FIXTURES
SVT_EX_TOWR 253 Continuous 0.15
(TELECOMS) : TOWER

Page 143 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING TELECOMMUNICATIONS LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SERVICES FIXTURES


SVT_EX_TRAN_
253 DASHDOT 0.15 (TELECOMS) : TRANSMISSION
NTWK
NETWORK
EXISTING SERVICES FIXTURES
SVT_EX_TRAN_ PT 253 Continuous 0.15
(TELECOMS) : TRANSMISSION POINT
EXISTING SERVICES FIXTURES
SVT_EX_UDCOR 253 Continuous 0.15 (TELECOMS) : UNDER GROUND
DUCT CORRIDOR
EXISTING SERVICES FIXTURES
SVT_EX_UGLN 253 Continuous 0.15
(TELECOMS) : UNDER GROUND LINE
EXISTING SERVICES FIXTURES
SVT_EX_VOD 253 VOD 0.15
(TELECOMS) : VODAFONE LINE
EXISTING SERVICES FIXTURES
SVT_EX_VOD_ VOD
253 0.15 (TELECOMS) : ABANDONED
ABDL ABANDONED
VODAFONE LINE

EXISTING WATER LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

WATER EXISTING SERVICES FIXTURES


SVW_EX_ABDL 253 0.15
ABANDONED (WATER) : ABANDONED WATER LINE
EXISTING SERVICES FIXTURES
SVW_EX_BNDL 253 Continuous 0.15
(WATER) : BUND
EXISTING SERVICES FIXTURES
SVW_EX_CLR_ PT 253 Continuous 0.15
(WATER) : CHLORINATION POINT

Page 144 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING WATER LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SERVICES FIXTURES


SVW_EX_CPRT 253 Continuous 0.15
(WATER) : CASING PROTECTION
SVW_EX_ EXISTING SERVICES FIXTURES
253 CHILLED WATER 0.15
CWMAIN (WATER) : CHILLED WATER MAIN
SVW_EX_ CHILLED WATER EXISTING SERVICES FIXTURES
253 0.15
CWMAIN_ABDL ABANDONED (WATER) : ABANDONED CHILLED
EXISTING SERVICES FIXTURES
WATER MAIN
SVW_EX_DRKL 253 Continuous 0.15
(WATER) : DRINKING AREA
EXISTING SERVICES FIXTURES
SVW_EX_DUCT 253 Continuous 0.15
(WATER) : DUCT
SVW_EX_FT_ EXISTING SERVICES FIXTURES
253 Continuous 0.15
ADPTR (WATER) : FITTING ADAPTER
SVW_EX_FT_ EXISTING SERVICES FIXTURES
253 Continuous 0.15
BEND (WATER) : FITTING BEND

SVW_EX_FT_ EXISTING SERVICES FIXTURES


253 Continuous 0.15
ENDCAP (WATER) : FITTING ENDCAP
SVW_EX_FT_ EXISTING SERVICES FIXTURES
253 Continuous 0.15
RDCR (WATER) : FITTING REDUCER

EXISTING SERVICES FIXTURES


SVW_EX_FT_ TEE 253 Continuous 0.15
(WATER) : FITTING TEE
EXISTING SERVICES FIXTURES
SVW_EX_GCHNL 253 Continuous 0.15
(WATER) : GRAVITY CHANNEL
EXISTING SERVICES FIXTURES
SVW_EX_GPIPE 253 Continuous 0.15
(WATER) : GRAVITY PIPE
EXISTING SERVICES FIXTURES
SVW_EX_HYDR 253 Continuous 0.15
(WATER) : HYDRANT
EXISTING SERVICES FIXTURES
SVW_EX_METER 253 Continuous 0.15
(WATER) : METER

Page 145 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING WATER LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING SERVICES FIXTURES


SVW_EX_MNHL 253 Continuous 0.15
(WATER) : MANHOLE
EXISTING SERVICES FIXTURES
SVW_EX_MRKR 253 Continuous 0.15
(WATER) : MARKER
EXISTING SERVICES FIXTURES
SVW_EX_PUMP 253 Continuous 0.15
(WATER) : PUMP
EXISTING SERVICES FIXTURES
SVW_EX_SCOCK 253 Continuous 0.15
(WATER) : STOPCOCK
EXISTING SERVICES FIXTURES
SVW_EX_SCSR 253 Continuous 0.15
(WATER) : SCADA SENSOR
EXISTING SERVICES FIXTURES
SVW_EX_SMETER 200 Continuous 0.15
(WATER) : SERVICE METER
EXISTING SERVICES FIXTURES
SVW_EX_SPIPE 253 Continuous 0.15
(WATER) : SERVICE PIPE

EXISTING SERVICES FIXTURES


SVW_EX_STRG_PT 253 Continuous 0.15
(WATER) : STORAGE POINT
EXISTING SERVICES FIXTURES
SVW_EX_TANK 253 Continuous 0.15
(WATER) : TANK

SVW_EX_TANK_ EXISTING SERVICES FIXTURES


253 Continuous 0.15
FIL_PT (WATER) : TANKER FILLING POINT
EXISTING SERVICES FIXTURES
SVW_EX_TEXT 253 Continuous 0.15
(WATER) : ANNOTATION / TEXT
EXISTING SERVICES FIXTURES
(WATER) : WATER SLUICE VALVE,
SVW_EX_VALV 253 Continuous 0.15 AIR VALVE, FLOW CONTROL
VALVE, SERVICE VALVE, SYSTEM
VALVE, VALVE

Page 146 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING WATER LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
EXISTING SERVICES FIXTURES
SVW_EX_WELL 253 Continuous 0.15
(WATER) : WELL
EXISTING SERVICES FIXTURES
SVW_EX_WFAC 253 Continuous 0.15
(WATER) : WATER FACILITY
EXISTING SERVICES FIXTURES
SVW_EX_WMAIN 253 WATER 0.15
(WATER) : WATER MAIN
EXISTING SERVICES FIXTURES
SVW_EX_WSCON 253 Continuous 0.15 (WATER) : WATER SERVICE
CONNECTION

A.7 UTILITY CORRIDOR LAYERS

UTILITY CORRIDOR LAYERS


Plotted Line
Layer Name Screen Colour Linetype Description
weight

GIS_UC_
199,255,255 Continuous 0.35 CHILLED WATER
CHILLED_WATER
DOHA SURVEILLANCE SECURITY
GIS_UC_DSSS 255,255,209 Continuous 0.35
SYSTEM
GIS_UC_
255,51,51 Continuous 0.35 ELECTRICITY (DISTRIBUTION)
ELECTRICITY_D
GIS_UC_
255,51,51 Continuous 0.35 ELECTRICITY (TRANSMISSION)
ELECTRICITY_T
GIS_UC_GAS 255,255,36 Continuous 0.35 GAS
ICT (INFORMATION AND
GIS_UC_ICT 189,248,160 Continuous 0.35
COMMUNICATION TECHNOLOGY)

ITS (INTELLIGENT TRANSPORT


GIS_UC_L_ITS 255,204,204 Continuous 0.35
SYSTEMS)

Page 147 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

UTILITY CORRIDOR LAYERS (Continuation...)

Plotted
Layer Name Screen Colour Linetype Line Description

weight
GIS_UC_SEWERAGE 128,96,0 Continuous 0.35 SEWERAGE

GIS_UC_SEWERAGE_FM 255,232,163 Continuous 0.35 SEWERAGE (FORCE MAIN)

GIS_UC_SOLID_WASTE_
237,221,254 Continuous 0.35 SOLID WASTE DISPOSAL
DISPOSAL
GIS_UC_SURFACE_WATER 214,161,0 Continuous 0.35 SURFACE WATER
GIS_UC_TELECOM 148,255,148 Continuous 0.35 TELECOMMUNICATIONS

TELECOMMUNICATIONS
GIS_UC_TELECOM_QAF 189,248,100 Continuous 0.35 QAF (QATAR ARMED
FORCES)

TSE (TREATED SEWAGE


GIS_UC_TSE 235,96,201 Continuous 0.35
EFFLUENT)

GIS_UC_WATER 185,185,254 Continuous 0.35 WATER

A.8 INTELLIGENT TRANSPORTATION SYSTEM - (ITS)

PROPOSED INTELLIGENT TRANSPORTATION SYSTEM LAYERS


Plotted
Layer Name Screen Colour Linetype Description
Line weight

ITS_PR_12- 12 DROP SMFO CABLE


MAGENTA HIDDEN 0.30
DROP_FIBER_ROUTE (PATHING DETAILS)

ITS_PR_1WAY-DUCT CYAN DIVIDE 0.40 PROPOSED DUCT 1WAY

ITS_PR_2WAY-DUCT 235,0,235 Continuous 0.35 PROPOSED DUCT 2WAY

ITS_PR_4WAY-DUCT 0,189,189 DASHDOTX2 0.35 PROPOSED DUCT 4WAY

Page 148 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED INTELLIGENT TRANSPORTATION SYSTEM LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

ITS_PR_6WAY-DUCT 224,6,12 DASHED 0.35 PROPOSED DUCT 6WAY


6
ITS_PR_8WAY-DUCT CYAN PHANTOM 0.40 PROPOSED DUCT 8WAY

ITS_PR_ALRM_A WHITE Continuous 0.25 PROPOSED AUDIBLE ALARM

PROPOSED AUDIO VISUAL


ITS_PR_ALRM_AV WHITE Continuous 0.25
ALARM

ITS_PR_ANTENNA RED Continuous 0.25 PROPOSED 3G/4G ANTENNA

ITS_PR_AP_DEV GREEN Continuous 0.25 PROPOSED ACCESS POINT

PROPOSED AIR QUALITY


ITS_PR_AQM_AS GREEN Continuous 0.30
MONITOR
PROPOSED BLUETOOTH
ITS_PR_BLUTH_DEV WHITE Continuous 0.25
ASSEMBLY
PROPOSED AUTOMATIC
ITS_PR_CCTV_AID RED Continuous 0.35
INCIDENT DETECTION
PROPOSED BOX JUNCTION
ITS_PR_CCTV_BJC RED Continuous 0.25
ENFORCEMENT CAMERA
PROPOSED FISH EYE LENS
ITS_PR_CCTV_FEL CYAN Continuous 0.25
CAMERA

ITS_PR_CCTV_FIXD RED Continuous 0.35 PROPOSED FIXED CCTV

PROPOSED LICENSE PLATE


ITS_PR_CCTV_LPR BLUE Continuous 0.35
READER
PROPOSED PAN TILT ZOOM
ITS_PR_CCTV_PTZ BLUE Continuous 0.35
CCTV CAMERA
ITS_PR_CHBR_DRA RED Continuous 0.20 PROPOSED DRAW CHAMBER
W
ITS_PR_CHBR_ITS YELLOW Continuous 0.20 PROPOSED ITS CHAMBER

Page 149 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED INTELLIGENT TRANSPORTATION SYSTEM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
ITS_PR_CHBR_JB WHITE Continuous DEFAULT PROPOSED JUNCTION BOX

ITS_PR_CHBR_SPL RED Continuous 0.20 PROPOSED SPLICE CHAMBER


ITS_PR_COMMS_ PROPOSED COPPER/NETWORK
92 Continuous 0.00
EQUIPMENT CONNECTION (PATHING DETAILS)
ITS_PR_COMMS- PROPOSED COMMUNICATION
WHITE Continuous 0.30
HUB HUB
PROPOSED DATA COLLECATION
ITS_PR_DATA-LOOP 62 Continuous 0.25
LOOP
PROPOSED DATA CABLE -
ITS_PR_DC-PRI GREEN Continuous 0.35
PRIMARY
PROPOSED DATA CABLE -
ITS_PR_DC-SEC WHITE Continuous 0.25
SECONDARY
ITS_PR_DC-TXT WHITE Continuous 0.25 PROPOSED DATA CABLE - TEXT
PROPOSED CENTER MOUNTED
ITS_PR_DMS RED Continuous 0.25
DYNAMIC MESSAGE SIGN

ITS_PR_DUCT_FO CYAN PHANTOM 0.40 PROPOSED FIBRE DUCTING

ITS_PR_DZON WHITE Continuous DEFAULT PROPOSED DETECTION ZONE

PROPOSED GROUND MOUNTED


ITS_PR_ENCL_
RED Continuous DEFAULT DOUBLE WIDTH ENCLOSURE
GME_DOUBLE
(WAN & ITS)
ITS_PR_ENCL_ PROPOSED GROUND MOUNTED
GREEN Continuous 0.30
GME_SINGLE_ITS SINGLE WIDTH ENCLOSURE (ITS)
ITS_PR_ENCL_GME PROPOSED GROUND MOUNTED
GREEN Continuous 0.30
_SINGLE_WAN SINGLE WIDTH ENCLOSURE (WAN)

PROPOSED POLE MOUNTED


ITS_PR_ENCL_ PME GREEN Continuous 0.30
ENCLOSURE

Page 150 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED INTELLIGENT TRANSPORTATION SYSTEM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
ITS_PR_ENCL_SML RED Continuous 0.30 PROPOSED SMALL ENCLOSURE
PROPOSED WALL MOUNTED ITS
ITS_PR_ENCL_WALL GREEN Continuous 0.30
ENCLOSURE

PROPOSED EMERGENCY
ITS_PR_ERT GREEN Continuous 0.35
ROADWAY TELEPHONE

ITS_PR_EXTRA_ PROPOSED SPARE/OTHER


92 PHANTOM2 0.30
DUCTING_ROUTE DUCTING (PATHING DETAILS)
PROPOSED FLASHING AMBER
ITS_PR_FAWL WHITE Continuous 0.25
WARNING LIGHT
ITS_PR_FEDR_PLR RED Continuous 0.25 PROPOSED FEEDER PILLAR

ITS_PR_FIBER- PROPOSED 96 LAN FIBRE


CYAN Continuous DEFAULT
96_LAN (SPLICING DETAILS)

ITS_PR_FIBER- PROPOSED 96 WAN FIBRE


251 Continuous DEFAULT
96_WAN (SPLICING DETAILS)

ITS_PR_FIBRE- PROPOSED 12 DROP FIBRE


BLUE Continuous 0.70
12_DROP (SPLICING DETAILS)
PROPOSED INSTRUMENT
ITS_PR_INST-SYM WHITE Continuous 0.25
SYMBOLS/LINEWORKS
ITS_PR_LAN_FIBRE_ ACAD_ PROPOSED LAN FIBRE PATH
140 0.30
ROUTE ISO05W100 (PATHING DETAILS)

ITS_PR_LCS GREEN Continuous 0.25 PROPOSED LANE CONTROL SIGN

ITS_PR_MAGN_DEV WHITE Continuous 0.25 PROPOSED MAGNETOMETER

PROPOSED OVER HEIGHT


ITS_PR_OVDS_AS WHITE Continuous 0.25
DETECTOR ASSEMBLY

PROPOSED PARKING
ITS_PR_PMS RED Continuous 0.25
MANAGEMENT SIGN

Page 151 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED INTELLIGENT TRANSPORTATION SYSTEM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
ITS_PR_POLE_15M GREEN Continuous 0.25 PROPOSED METAL POLE 15M
ITS_PR_POLE_6M GREEN Continuous 0.25 PROPOSED METAL POLE 6M

ITS_PR_REP_DEV GREEN Continuous 0.30 PROPOSED REPEATER UNIT

PROPOSED ROAD WEATHER


ITS_PR_RWIS_AS GREEN Continuous 0.30
INFORMATION SYSTEM

PROPOSED SMALL DYNAMIC


ITS_PR_SDMS RED Continuous 0.25
MESSAGE SIGN (POST MOUNTED)

ITS_PR_TRANS WHITE Continuous 0.25 PROPOSED TRANSFORMER


PROPOSED CANTILEVER POST
ITS_PR_TRUSS_CA RED Continuous 0.30
(SMALL)

PROPOSED SIZED FOR FULL SPAN


ITS_PR_TRUSS_FUL RED Continuous 0.30
TRUSS, MID SPAN TRUSS

PROPOSED VEHICLE ACTIVATED


ITS_PR_VAS RED Continuous 0.25
SIGN
ITS_PR_WAN_FIBRE_ ACAD_ISO10 PROPOSED WAN FIBRE PATH
RED 0.30
ROUTE W100 (PATHING DETAILS)
PROPOSED WEIGH IN MOTION
ITS_PR_WIM_LOOP BLUE Continuous 0.35
SYSTEM

EXISTING INTELLIGENT TRANSPORTATION SYSTEM LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

ITS_EX_1WAY-DUCT 253 DIVIDE 0.35 EXISTING DUCT 1WAY

ITS_EX_2WAY-DUCT 253 Continuous 0.35 EXISTING DUCT 2WAY

Page 152 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING INTELLIGENT TRANSPORTATION SYSTEM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

ITS_EX_4WAY-DUCT 253 DASHDOTX2 0.35 EXISTING DUCT 4WAY

ITS_EX_6WAY-DUCT 253 DASHED 0.35 EXISTING DUCT 6WAY

ITS_EX_8WAY-DUCT 253 PHANTOM 0.35 EXISTING DUCT 8WAY

ITS_EX_ALRM_A 253 HIDDEN 0.10 EXISTING AUDIBLE ALARM

EXISTING AUDIO VISUAL


ITS_EX_ALRM_AV 253 HIDDEN 0.10
ALARM
ITS_EX_ANTENNA 253 Continuous DEFAULT EXISTING 3G/4G ANTENNA

ITS_EX_AP_DEV 253 HIDDEN 0.10 EXISTING ACCESS POINT

EXISTING AIR QUALITY


ITS_EX_AQM_AS 253 HIDDEN 0.10
MONITOR
EXISTING BLUETOOTH
ITS_EX_BLUTH_DEV 253 HIDDEN 0.10
ASSEMBLY
EXISTING AUTOMATIC
ITS_EX_CCTV_AID 253 HIDDEN 0.10
INCIDENT DETECTION
EXISTING BOX JUNCTION
ITS_EX_CCTV_BJC 253 HIDDEN 0.10
ENFORCEMENT CAMERA
EXISTING FISH EYE LENS
ITS_EX_CCTV_FEL 253 HIDDEN 0.10
CAMERA
ITS_EX_CCTV_FIXD 253 HIDDEN 0.10 EXISTING FIXED CCTV

EXISTING LICENSE PLATE


ITS_EX_CCTV_LPR 253 HIDDEN 0.10
READER
EXISTING PAN TILT ZOOM
ITS_EX_CCTV_PTZ 253 HIDDEN 0.10
CCTV CAMERA
ITS_EX_CHBR_DRAW 253 HIDDEN 0.10 EXISTING DRAW CHAMBER

Page 153 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING INTELLIGENT TRANSPORTATION SYSTEM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

ITS_EX_CHBR_ITS 253 HIDDEN 0.10 EXISTING ITS CHAMBER

ITS_EX_CHBR_JB 253 HIDDEN 0.10 EXISTING JUNCTION BOX

ITS_EX_CHBR_SPL 253 HIDDEN 0.10 EXISTING SPLICE CHAMBER

ITS_EX_COMMS-HUB 253 Continuous 0.30 EXISTING COMMUNICATION HUB

EXISTING DATA COLLECATION


ITS_EX_DATA-LOOP 253 Continuous 0.25
LOOP
ITS_EX_DC-PRI 253 Continuous 0.35 EXISTING DATA CABLE - PRIMARY

EXISTING DATA CABLE -


ITS_EX_DC-SEC 253 Continuous 0.25
SECONDARY
ITS_EX_DC-TXT 253 Continuous 0.25 EXISTING DATA CABLE - TEXT

EXISTING CENTER MOUNTED


ITS_EX_DMS 253 HIDDEN 0.10
DYNAMIC MESSAGE SIGN
ITS_EX_DUCT_FO 253 PHANTOM 0.10 EXISTING FIBRE DUCTING

ITS_EX_DZON 253 HIDDEN 0.10 EXISTING MAGNETOMETER

EXISTING GROUND MOUNTED


ITS_EX_ENCL_GME_
253 HIDDEN 0.10 DOUBLE WIDTH ENCLOSURE (WAN
DOUBLE
& ITS)
ITS_EX_ENCL_GME_ EXISTING GROUND MOUNTED
253 HIDDEN 0.10
SINGLE_ITS SINGLE WIDTH ENCLOSURE (ITS)
ITS_EX_ENCL_GME_ EXISTING GROUND MOUNTED
253 HIDDEN 0.10
SINGLE_WAN SINGLE WIDTH ENCLOSURE (WAN)
EXISTING GROUND MOUNTED
ITS_EX_ENCL_GRD 253 HIDDEN 0.10
ENCLOSURE
EXISTING POLE MOUNTED
ITS_EX_ENCL_PME 253 HIDDEN 0.10
ENCLOSURE

Page 154 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING INTELLIGENT TRANSPORTATION SYSTEM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

ITS_EX_ENCL_SML 253 HIDDEN 0.10 EXISTING SMALL ENCLOSURE

EXISTING WALL MOUNTED ITS


ITS_EX_ENCL_WALL 253 HIDDEN 0.10
ENCLOSURE
EXISTING EMERGENCY ROADWAY
ITS_EX_ERT 253 HIDDEN 0.10
TELEPHONE
EXISTING FLASHING AMBER
ITS_EX_FAWL 253 HIDDEN 0.10
WARNING LIGHT
ITS_EX_FEDR_PLR 253 HIDDEN 0.10 EXISTING FEEDER PILLAR

EXISTING INSTRUMENT
ITS_EX_INST-SYM 253 Continuous 0.25
SYMBOLS/LINEWORKS

ITS_EX_LCS 253 HIDDEN 0.10 EXISTING LANE CONTROL SIGN

EXISTING BOX JUNCTION


ITS_EX_MAGN_DEV 253 HIDDEN 0.10
ENFORCEMENT CAMERA
EXISTING OVER HEIGHT DETECTOR
ITS_EX_OVDS_AS 253 HIDDEN 0.10
ASSEBLY
EXISTING PARKING MANAGEMENT
ITS_EX_PMS 253 HIDDEN 0.10
SIGN
ITS_EX_POLE_15m 253 HIDDEN 0.10 EXISTING METAL POLE 15m

ITS_EX_POLE_6m 253 HIDDEN 0.10 EXISTING METAL POLE 6m

ITS_EX_REP_DEV 253 HIDDEN 0.10 EXISTING REPEATER UNIT

EXISTING ROAD WEATHER


ITS_EX_RWIS_AS 253 HIDDEN 0.10
INFORMATION SYSTEM
EXISTING SMALL DYNAMIC
ITS_EX_SDMS 253 HIDDEN 0.10
MESSAGE SIGN (POST MOUNTED)
ITS_EX_TRANS 253 HIDDEN 0.10 EXISTING TRANSFORMER

Page 155 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING INTELLIGENT TRANSPORTATION SYSTEM LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

EXISTING CANTILEVER POST


ITS_EX_TRUSS_CA 253 HIDDEN 0.10
(SMALL)
EXISTING SIZED FOR FULL
ITS_EX_TRUSS_FUL 253 HIDDEN 0.10
SPAN TRUSS, MID SPAN TRUSS
EXISTING VEHICLE ACTIVATED
ITS_EX_VAS 253 HIDDEN 0.10
SIGN
EXISTING WEIGH IN MOTION
ITS_EX_WIM_LOOP 253 HIDDEN 0.10
SYSTEM

PROPOSED SCADA LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

SCA_PR_AP_DEV YELLOW Continuous 0.25 PROPOSED SCADA ACCESS POINT

PROPOSED SCADA AIR QUALITY


SCA_PR_AQM_DEV YELLOW Continuous 0.25
MONITOR

SCA_PR_CCTV YELLOW Continuous 0.25 PROPOSED SCADA FIXED CCTV

PROPOSED SCADA AUTOMATIC


SCA_PR_CCTV_AID YELLOW Continuous 0.25
INCIDENT DETECTION
SCA_PR_CHBR_ITS RED Continuous 0.10 PROPOSED SCADA CHAMBER
PROPOSED SCADA SPLICE
SCA_PR_CHBR_SPL RED Continuous 0.10
CHAMBER
PROPOSED SCADA SMALL
SCA_PR_ENCL_SML RED Continuous 0.10
ENCLOSURE
PROPOSED SCADA FLASHING
SCA_PR_FAWL WHITE Continuous 0.25
AMBER WARNING LIGHT

Page 156 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED SCADA LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight
PROPOSED SCADA LANE
SCA_PR_LCS GREEN Continuous 0.35
CONTROL SIGN
PROPOSED SCADA REPEATER
SCA_PR_REP_DEV YELLOW Continuous 0.25
UNIT
PROPOSED SCADA ROAD
SCA_PR_RWIS_AS YELLOW Continuous 0.25
WEATHER INFORMATION SYSTEM
PROPOSED SCADA SMALL
SCA_PR_SDMS GREEN Continuous 0.35
DYNAMIC MESSAGE SIGN
PROPOSED SCADA WEIGH IN
SCA_PR_WIM_LOOP GREEN Continuous 0.35
MOTION SYSTEM

EXISTING SCADA LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line weight

SCA_EX_AP_DEV 253 HIDDEN 0.10 EXISTING ACCESS POINT

SCA_EX_AQM_DEV 253 HIDDEN 0.10 EXISTING AIR QUALITY MONITOR

SCA_EX_CCTV 253 HIDDEN 0.10 EXISTING FIXED CCTV


EXISTING AUTOMATIC INCIDENT
SCA_EX_CCTV_AID 253 HIDDEN 0.10
DETECTION
SCA_EX_CHBR_ITS 253 HIDDEN 0.10 EXISTING CHAMBER

SCA_EX_CHBR_SPL 253 HIDDEN 0.10 EXISTING SPLICE CHAMBER

SCA_EX_ENCL_SML 253 HIDDEN 0.10 EXISTING SMALL ENCLOSURE

EXISTING FLASHING AMBER


SCA_EX_FAWL 253 HIDDEN 0.10
WARNING LIGHT

Page 157 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING SCADA LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line weight

SCA_EX_LCS 253 HIDDEN 0.10 EXISTING LANE CONTROL SIGN

SCA_EX_REP_DEV 253 HIDDEN 0.10 EXISTING REPEATER UNIT

EXISTING ROAD WEATHER


SCA_EX_RWIS_AS 253 HIDDEN 0.10
INFORMATION SYSTEM
EXISTING SMALL DYNAMIC
SCA_EX_SDMS 253 HIDDEN 0.10
MESSAGE SIGN
EXISTING WEIGH IN MOTION
SCA_EX_WIM_LOOP 253 HIDDEN 0.10
SYSTEM

PROPOSED STRUCTURAL LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_ABUTMENT_BARRIER10 RED CONTINUOUS 0.10 ABUTMENT BARRIER


S_PR_ABUTMENT_BARRIER10H RED HIDDEN 0.10 ABUTMENT BARRIER
S_PR_ABUTMENT_BARRIER25 WHITE CONTINUOUS 0.25 ABUTMENT BARRIER
S_PR_ABUTMENT_BARRIER25H WHITE HIDDEN 0.25 ABUTMENT BARRIER
S_PR_ABUTMENT_BARRIER35 GREEN CONTINUOUS 0.35 ABUTMENT BARRIER
S_PR_ABUTMENT_BARRIER50 CYAN CONTINUOUS 0.50 ABUTMENT BARRIER

S_PR_ABUTMENT_BEARING10 RED CONTINUOUS 0.10 ABUTMENT BEARING

S_PR_ABUTMENT_
RED HIDDEN 0.10 ABUTMENT BEARING
BEARING10H
S_PR_ABUTMENT_ ABUTMENT BEARING
RED CENTER 0.10
BEARINGSOL10C SET-OUT LINE

Page 158 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Plotted
Screen
Layer Name Linetype Line Description
Colour
Weight

S_PR_ABUTMENT_HATCH253 253 CONTINUOUS 0.15 ABUTMENT HATCH


S_PR_ABUTMENT_ ABUTMENT MORTAR
RED CONTINUOUS 0.10
MORTARPAD10 PAD
S_PR_ABUTMENT_PILE10C RED CENTER 0.10 ABUTMENT PILE
S_PR_ABUTMENT_PILE10H2 RED HIDDEN2 0.10 ABUTMENT PILE
S_PR_ABUTMENT_PILE25 WHITE CONTINUOUS 0.25 ABUTMENT PILE
S_PR_ABUTMENT_PILELINER10 RED CONTINUOUS 0.10 ABUTMENT PILE LINER
S_PR_ABUTMENT_PILELINER10H RED HIDDEN 0.10 ABUTMENT PILE LINER
S_PR_ABUTMENT_PILELINER25 WHITE CONTINUOUS 0.25 ABUTMENT PILE LINER
S_PR_ABUTMENT_PILELINER25H WHITE HIDDEN 0.25 ABUTMENT PILE LINER
S_PR_ABUTMENT_PILELINER35 GREEN CONTINUOUS 0.35 ABUTMENT PILE LINER
S_PR_ABUTMENT_PILELINER50 CYAN CONTINUOUS 0.50 ABUTMENT PILE LINER
ABUTMENT SET-OUT
S_PR_ABUTMENT_SOL10C RED CENTER 0.10
LINE
S_PR_ABUTMENT 10 RED CONTINUOUS 0.10 ABUTMENT
S_PR_ABUTMENT 10H RED HIDDEN 0.10 ABUTMENT
S_PR_ABUTMENT25 WHITE CONTINUOUS 0.25 ABUTMENT
S_PR_ABUTMENT25H WHITE HIDDEN 0.25 ABUTMENT
S_PR_ABUTMENT35 GREEN CONTINUOUS 0.35 ABUTMENT
S_PR_ABUTMENT50 CYAN CONTINUOUS 0.50 ABUTMENT
S_PR_ANCHOR10 RED CONTINUOUS 0.10 ANCHOR
S_PR_ANCHOR10C RED CENTER 0.10 ANCHOR
S_PR_ANCHOR10H RED HIDDEN 0.10 ANCHOR
S_PR_ANCHOR13C2 9 CENTER2 0.15 ANCHOR
S_PR_ANCHOR25 WHITE CONTINUOUS 0.25 ANCHOR

Page 159 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight
S_PR_ANCHOR25H WHITE HIDDEN 0.25 ANCHOR
S_PR_ANCHOR35 WHITE CONTINUOUS 0.25 ANCHOR
S_PR_ANCHOR50 RED CONTINUOUS 0.10 ANCHOR
S_PR_APPSL RED CONTINUOUS 0.10 APPROACH SLAB
S_PR_BARRIER 200 CONTINUOUS 0.35 BARRIER
S_PR_BARRIER_JOINT RED CONTINUOUS 0.10 BARRIER JOINT
S_PR_BARRIER10 RED CONTINUOUS 0.10 BARRIER
S_PR_BARRIER10H RED HIDDEN 0.10 BARRIER
S_PR_BARRIER25 WHITE CONTINUOUS 0.25 BARRIER
S_PR_BARRIER25H WHITE HIDDEN 0.25 BARRIER
S_PR_BARRIER35 GREEN CONTINUOUS 0.35 BARRIER
S_PR_BARRIER50 CYAN CONTINUOUS 0.50 BARRIER
S_PR_BASE10 RED CONTINUOUS 0.10 BASE
S_PR_BASE10H RED HIDDEN 0.10 BASE
S_PR_BASE25 WHITE CONTINUOUS 0.25 BASE
S_PR_BASE25H WHITE HIDDEN 0.25 BASE
S_PR_BASE35 GREEN CONTINUOUS 0.35 BASE
S_PR_BASE50 RED CONTINUOUS 0.10 BASE
S_PR_BATTER10 RED CONTINUOUS 0.10 BATTER
S_PR_BATTER10D RED DASHED 0.10 BATTER
S_PR_BATTER10H RED HIDDEN 0.10 BATTER
S_PR_BATTER25 WHITE CONTINUOUS 0.25 BATTER
S_PR_BATTER25H WHITE HIDDEN 0.25 BATTER
S_PR_BATTER35 GREEN CONTINUOUS 0.35 BATTER
S_PR_BATTER50 CYAN CONTINUOUS 0.50 BATTER

S_PR_BLINDING18 RED CONTINUOUS 0.18 BLINDING CONCRETE

Page 160 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_BOREHOLE25 WHITE CONTINUOUS 0.25 BOREHOLE


S_PR_BOREHOLE35 GREEN CONTINUOUS 0.35 BOREHOLE
S_PR_CAPPING-BEAM10 RED CONTINUOUS 0.10 CAPPING BEAM
S_PR_CAPPING-BEAM10H RED HIDDEN 0.10 CAPPING BEAM
S_PR_CAPPING-BEAM25 WHITE CONTINUOUS 0.25 CAPPING BEAM
S_PR_CAPPING-BEAM25H WHITE HIDDEN 0.25 CAPPING BEAM
S_PR_CAPPING-BEAM35 GREEN CONTINUOUS 0.35 CAPPING BEAM
S_PR_CAPPING-BEAM50 CYAN CONTINUOUS 0.50 CAPPING BEAM
S_PR_CAST-IN10 RED CONTINUOUS 0.10 CAST-IN
S_PR_CAST-IN10H RED HIDDEN 0.10 CAST-IN
S_PR_CAST-IN13C2 9 CENTER2 0.15 CAST-IN
S_PR_CAST-IN25 WHITE CONTINUOUS 0.25 CAST-IN
S_PR_CAST-IN25H WHITE HIDDEN 0.25 CAST-IN
S_PR_CAST-IN35 GREEN CONTINUOUS 0.35 CAST-IN
S_PR_CAST-IN50 CYAN CONTINUOUS 0.50 CAST-IN
S_PR_CJ1 RED CJ1 0.10 CONSTRUCTION JOINT
S_PR_CJ2 RED CJ2 0.10 CONSTRUCTION JOINT
S_PR_CLADDING10 RED CONTINUOUS 0.10 CLADDING
S_PR_CLADDING10H RED HIDDEN 0.10 CLADDING
S_PR_CLADDING25 WHITE CONTINUOUS 0.25 CLADDING
S_PR_COLUMN10 RED CONTINUOUS 0.10 COLUMN
S_PR_COLUMN10C RED CENTER 0.10 COLUMN
S_PR_COLUMN10H RED HIDDEN 0.10 COLUMN
S_PR_COLUMN25 WHITE CONTINUOUS 0.25 COLUMN
S_PR_COLUMN25H WHITE HIDDEN 0.25 COLUMN

Page 161 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_COLUMN35 GREEN CONTINUOUS 0.35 COLUMN


S_PR_COLUMN50 CYAN CONTINUOUS 0.50 COLUMN
S_PR_CONC10 RED CONTINUOUS 0.10 CONCRETE
S_PR_CONC10H RED HIDDEN 0.10 CONCRETE
S_PR_CONC18C RED CENTER 0.18 CONCRETE
S_PR_CONC25 WHITE CONTINUOUS 0.25 CONCRETE
S_PR_CONC25H WHITE HIDDEN 0.25 CONCRETE
S_PR_CONC35 GREEN CONTINUOUS 0.35 CONCRETE
S_PR_CONC50 CYAN CONTINUOUS 0.50 CONCRETE
S_PR_CONDUIT10 RED CONTINUOUS 0.10 CONDUIT
S_PR_CONDUIT10C RED CENTER 0.10 CONDUIT
S_PR_CONDUIT10H RED HIDDEN 0.10 CONDUIT
S_PR_CONDUIT13C2 9 CENTER2 0.15 CONDUIT
S_PR_CONDUIT25 WHITE CONTINUOUS 0.25 CONDUIT
S_PR_CONDUIT25H WHITE CONTINUOUS 0.25 CONDUIT
S_PR_CONDUIT35 GREEN CONTINUOUS 0.35 CONDUIT
S_PR_CONDUIT50 CYAN CONTINUOUS 0.50 CONDUIT
S_PR_CONTROL RED CENTER 0.10 CONTROL LINE
S_PR_COVERPLATE10 RED CONTINUOUS 0.10 COVERPLATE
S_PR_COVERPLATE10H RED HIDDEN 0.10 COVERPLATE
S_PR_COVERPLATE13C2 9 CENTER2 0.15 COVERPLATE
S_PR_COVERPLATE25 WHITE CONTINUOUS 0.25 COVERPLATE
S_PR_COVERPLATE25H WHITE HIDDEN 0.25 COVERPLATE
S_PR_COVERPLATE35 GREEN CONTINUOUS 0.35 COVERPLATE
S_PR_COVERPLATE50 CYAN CONTINUOUS 0.50 COVERPLATE

Page 162 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_DECK_CJ1 RED CJ1 0.10 DECK


S_PR_DECK_DIAPHRAGM10H RED HIDDEN 0.10 CONSTRUCTION
DECK DIAPHRAGM

S_PR_DECK_DIAPHRAGM25H WHITE HIDDEN 0.25 JOINT


DECK DIAPHRAGM

S_PR_DECK_SOFFIT10H RED HIDDEN 0.10 DECK SOFFIT


S_PR_DECK_SOFFIT25 WHITE CONTINUOUS 0.25 DECK SOFFIT
S_PR_DECK_SOFFIT35 GREEN CONTINUOUS 0.35 DECK SOFFIT
S_PR_DECK10 RED CONTINUOUS 0.10 DECK
S_PR_DECK10H RED HIDDEN 0.10 DECK
S_PR_DECK25 WHITE CONTINUOUS 0.25 DECK
S_PR_DECK25H WHITE HIDDEN 0.25 DECK
S_PR_DECK35 GREEN CONTINUOUS 0.35 DECK
S_PR_DECK50 CYAN CONTINUOUS 0.50 DECK
S_PR_DIAPHRAGM_WALL10 RED CONTINUOUS 0.10 DIAPHRAGM WALL
S_PR_DIAPHRAGM_WALL10H RED HIDDEN 0.10 DIAPHRAGM WALL
S_PR_DIAPHRAGM_WALL25 WHITE CONTINUOUS 0.25 DIAPHRAGM WALL
S_PR_DIAPHRAGM_WALL25H WHITE HIDDEN 0.25 DIAPHRAGM WALL
S_PR_DIAPHRAGM_WALL35 GREEN CONTINUOUS 0.35 DIAPHRAGM WALL
S_PR_DIAPHRAGM_WALL50 CYAN CONTINUOUS 0.50 DIAPHRAGM WALL
S_PR_DOWELBAR40 CYAN CONTINUOUS 0.50 DOWEL BARS
S_PR_DRAINAGE10 RED CONTINUOUS 0.10 DRAINAGE
S_PR_DRAINAGE10C RED CENTER 0.10 DRAINAGE
S_PR_DRAINAGE10H RED HIDDEN 0.10 DRAINAGE
S_PR_DRAINAGE13C2 9 CENTER2 0.15 DRAINAGE
S_PR_DRAINAGE25 WHITE CONTINUOUS 0.25 DRAINAGE
S_PR_DRAINAGE25H WHITE HIDDEN 0.25 DRAINAGE

Page 163 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_DRAINAGE35 GREEN CONTINUOUS 0.35 DRAINAGE


S_PR_DRAINAGE50 CYAN CONTINUOUS 0.50 DRAINAGE
S_PR_EXPANSIONJOINT10 RED CONTINUOUS 0.10 EXPANSION JOINT
S_PR_EXPANSIONJOINT10C RED CENTER 0.10 EXPANSION JOINT
S_PR_EXPANSIONJOINT10H RED HIDDEN 0.10 EXPANSION JOINT
S_PR_EXPANSIONJOINT13C2 9 CENTER2 0.15 EXPANSION JOINT
S_PR_EXPANSIONJOINT25 WHITE CONTINUOUS 0.25 EXPANSION JOINT
S_PR_EXPANSIONJOINT25H WHITE HIDDEN 0.25 EXPANSION JOINT
S_PR_EXPANSIONJOINT35 GREEN CONTINUOUS 0.35 EXPANSION JOINT
S_PR_EXPANSIONJOINT50 CYAN CONTINUOUS 0.50 EXPANSION JOINT
S_PR_FC RED CONTINUOUS 0.10 FIRE CABINET ON PLAN
S_PR_FIREBOARD CYAN HIDDEN 0.50 FIRE BOARD PROTECTION
S_PR_FLOOR10 RED CONTINUOUS 0.10 FLOOR
S_PR_FLOOR10H RED HIDDEN 0.10 FLOOR
S_PR_FLOOR25 WHITE CONTINUOUS 0.25 FLOOR
S_PR_FLOOR25H WHITE HIDDEN 0.25 FLOOR
S_PR_FLOOR35 GREEN CONTINUOUS 0.35 FLOOR
S_PR_FLOOR50 CYAN CONTINUOUS 0.50 FLOOR
S_PR_FOOTING10 RED CONTINUOUS 0.10 FOOTING
S_PR_FOOTING10H RED HIDDEN 0.10 FOOTING
S_PR_FOOTING25 WHITE CONTINUOUS 0.25 FOOTING
S_PR_FOOTING25H WHITE HIDDEN 0.25 FOOTING
S_PR_FOOTING35 GREEN CONTINUOUS 0.35 FOOTING
S_PR_FOOTING50 CYAN CONTINUOUS 0.50 FOOTING

S_PR_FSL RED CONTINUOUS 0.10 FINISHED SURFACE LEVEL

Page 164 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_GIRDER_SOFFIT10H RED HIDDEN 0.10 GIRDER SOFFIT


S_PR_GIRDER_SOFFIT25 WHITE CONTINUOUS 0.25 GIRDER SOFFIT
S_PR_GIRDER_SOFFIT25C WHITE CENTER 0.25 GIRDER SOFFIT
S_PR_GIRDER_TOP10C RED CENTER 0.10 GIRDER TOP
S_PR_GIRDER10 RED CONTINUOUS 0.10 GIRDER
S_PR_GIRDER10C RED CENTER 0.10 GIRDER
S_PR_GIRDER10H RED HIDDEN 0.10 GIRDER
S_PR_GIRDER25 WHITE CONTINUOUS 0.25 GIRDER
S_PR_GIRDER25H WHITE HIDDEN 0.25 GIRDER
S_PR_GIRDER35 GREEN CONTINUOUS 0.35 GIRDER
S_PR_GIRDER50 CYAN CONTINUOUS 0.50 GIRDER
S_PR_HATCH 250 CONTINUOUS 0.15 HATCH
S_PR_HATCH_SAND WHITE CONTINUOUS 0.25 SAND COLOUR

S_PR_HATCH120 120 CONTINUOUS 0.35 SHADE 120


S_PR_HATCH251 251 CONTINUOUS 0.15 SHADE 251
S_PR_HATCH252 252 CONTINUOUS 0.15 SHADE 252
S_PR_HATCH253 253 CONTINUOUS 0.15 HATCH 253
S_PR_HATCH254 254 CONTINUOUS 0.15 SHADE 254
S_PR_HATCH255 255 CONTINUOUS 0.15 SHADE 255
S_PR_HATCH81 81 CONTINUOUS 0.35 SHADE 81
S_PR_HATCH253-BNDY 40 CONTINUOUS 0.35 HATCH BOUNDARY
S_PR_KERB RED CONTINUOUS 0.10 KERBS ON PLAN
S_PR_KERB10 RED CONTINUOUS 0.10 KERB
S_PR_KERB25 WHITE CONTINUOUS 0.25 KERB
S_PR_KERB35 GREEN CONTINUOUS 0.35 KERB

Page 165 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_KERB50 CYAN CONTINUOUS 0.50 KERB


S_PR_LAMP10 RED CONTINUOUS 0.10 LAMP
S_PR_LAMP10H RED HIDDEN 0.10 LAMP
S_PR_LAMP25 WHITE CONTINUOUS 0.25 LAMP
S_PR_LAMP25H WHITE HIDDEN 0.25 LAMP
S_PR_LAMP35 GREEN CONTINUOUS 0.35 LAMP
S_PR_LAMP50 CYAN CONTINUOUS 0.50 LAMP
S_PR_MATCHLINE BLUE CENTER 0.70 MATCHLINE
NORTHBOUND SLIP
S_PR_NB_SLIPRD 152 CONTINUOUS 0.35
ROAD PROFILE
S_PR_MISC25 WHITE CONTINUOUS 0.25 MISC
NATURAL GROUND
S_PR_NGL RED CONTINUOUS 0.10
LEVEL
S_PR_PANEL10 RED CONTINUOUS 0.10 PANEL
S_PR_PANEL10H RED HIDDEN 0.10 PANEL
S_PR_PANEL25 WHITE CONTINUOUS 0.25 PANEL
S_PR_PANEL35 GREEN CONTINUOUS 0.35 PANEL
S_PR_PANEL50 CYAN CONTINUOUS 0.50 PANEL
PARTIAL
S_PR_PCJ18 RED HIDDEN 0.18
CONTRACTION JOINT
S_PR_PIER_BEARING10 RED CONTINUOUS 0.10 PIER BEARING
S_PR_PIER_BEARING10H RED HIDDEN 0.10 PIER BEARING
PIER BEARING SET-
S_PR_PIER_BEARINGSOL10C RED CENTER 0.10
OUT LINE
S_PR_PIER_COLUMN10 RED CONTINUOUS 0.10 PIER COLUMN

Page 166 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_PIER_COLUMN10C RED CENTER 0.10 PIER COLUMN


S_PR_PIER_COLUMN10H RED HIDDEN 0.10 PIER COLUMN
S_PR_PIER_COLUMN25 WHITE CONTINUOUS 0.25 PIER COLUMN
S_PR_PIER_COLUMN25H WHITE HIDDEN 0.25 PIER COLUMN
S_PR_PIER_COLUMN35 GREEN CONTINUOUS 0.35 PIER COLUMN
S_PR_PIER_COLUMN50 CYAN CONTINUOUS 0.50 PIER COLUMN
S_PR_PIER_FOOTING25 WHITE CONTINUOUS 0.25 PIER FOOTING
S_PR_PIER_FOOTING35 GREEN CONTINUOUS 0.35 PIER FOOTING
S_PR_PIER_HATCH253 253 CONTINUOUS 0.15 PIER HATCH
S_PR_PIER_HEADSTOCK10 RED CONTINUOUS 0.10 PIER HEADSTOCK
S_PR_PIER_HEADSTOCK10H RED HIDDEN 0.10 PIER HEADSTOCK
S_PR_PIER_HEADSTOCK25 WHITE CONTINUOUS 0.25 PIER HEADSTOCK
S_PR_PIER_HEADSTOCK25H WHITE HIDDEN 0.25 PIER HEADSTOCK
S_PR_PIER_HEADSTOCK35 GREEN CONTINUOUS 0.35 PIER HEADSTOCK
S_PR_PIER_HEADSTOCK50 CYAN CONTINUOUS 0.50 PIER HEADSTOCK
S_PR_PIER_MORTARPAD10 RED CONTINUOUS 0.10 PIER MORTAR PAD
S_PR_PIER_PILE10C RED CENTER 0.10 PIER PILE
S_PR_PIER_PILE10H2 RED HIDDEN2 0.10 PIER PILE
S_PR_PIER_PILE25 WHITE CONTINUOUS 0.25 PIER PILE
S_PR_PIER_PILECAP10 RED CONTINUOUS 0.10 PIER PILECAP
S_PR_PIER_PILECAP10H RED HIDDEN 0.10 PIER PILECAP
S_PR_PIER_PILECAP25 WHITE CONTINUOUS 0.25 PIER PILECAP
S_PR_PIER_PILECAP25H WHITE HIDDEN 0.25 PIER PILECAP
S_PR_PIER_PILECAP35 GREEN CONTINUOUS 0.35 PIER PILECAP
S_PR_PIER_PILECAP50 CYAN CONTINUOUS 0.50 PIER PILECAP

Page 167 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_PIER_PILESOL10C RED CENTER 0.10 PIER PILE SETOUT LINE


S_PR_PIER_SOL10C RED CENTER 0.10 PIER SETOUT LINE
S_PR_PIER10 RED CONTINUOUS 0.10 PIER
S_PR_PIER10H RED HIDDEN 0.10 PIER
S_PR_PIER25 WHITE CONTINUOUS 0.25 PIER
S_PR_PIER25H WHITE HIDDEN 0.25 PIER
S_PR_PIER35 GREEN CONTINUOUS 0.35 PIER
S_PR_PIER50 CYAN CONTINUOUS 0.50 PIER
S_PR_RAIL_HD GREEN CONTINUOUS 0.35 RAIL
S_PR_RAIL10 RED CONTINUOUS 0.10 RAIL
S_PR_RAIL10C RED CENTER 0.10 RAIL
S_PR_RAIL10H RED HIDDEN 0.10 RAIL
S_PR_RAIL13C2 9 CENTER2 0.15 RAIL
S_PR_RAIL25 WHITE CONTINUOUS 0.25 RAIL
S_PR_RAIL35 GREEN CONTINUOUS 0.35 RAIL
S_PR_RAIL50 CYAN CONTINUOUS 0.50 RAIL
S_PR_RELIEVINGSLAB_ RELIEVING SLAB
RED CONTINUOUS 0.10
EXPANSIONJOINT10 EXPANSION JOINT
S_PR_REINFT18H RED HIDDEN 0.18 REINFORCEMENT HIDDEN

S_PR_REINFT50 CYAN CONTINUOUS 0.50 REINFORCEMENT

S_PR_RELIEVINGSLAB_ RELIEVING SLAB


9 CONTINUOUS 0.15
EXPANSIONJOINT13 EXPANSION JOINT

S_PR_RELIEVINGSLAB_ RELIEVING SLAB


WHITE CONTINUOUS 0.25
EXPANSIONJOINT25 EXPANSION JOINT

S_PR_RELIEVINGSLAB10 RED CONTINUOUS 0.10 RELIEVING SLAB

Page 168 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_RELIEVINGSLAB10H RED HIDDEN 0.10 RELIEVING SLAB


S_PR_RELIEVINGSLAB13H 9 HIDDEN 0.15 RELIEVING SLAB
S_PR_RELIEVINGSLAB25 WHITE CONTINUOUS 0.25 RELIEVING SLAB
S_PR_RELIEVINGSLAB25H WHITE HIDDEN 0.25 RELIEVING SLAB
S_PR_RELIEVINGSLAB35 GREEN CONTINUOUS 0.35 RELIEVING SLAB
S_PR_RELIEVINGSLAB50 CYAN CONTINUOUS 0.50 RELIEVING SLAB
S_PR_REO10 RED CONTINUOUS 0.10 REO
S_PR_REO10H RED HIDDEN 0.10 REO
S_PR_REO25 WHITE CONTINUOUS 0.25 REO
S_PR_REO252 252 CONTINUOUS 0.15 REO
S_PR_REO25H WHITE HIDDEN 0.25 REO
S_PR_REO35 GREEN CONTINUOUS 0.35 REO
S_PR_REO35H GREEN HIDDEN 0.35 REO
S_PR_REO50 CYAN CONTINUOUS 0.50 REO
S_PR_REO50H CYAN HIDDEN 0.50 REO
S_PR_REO70 BLUE CONTINUOUS 0.70 REO
S_PR_RETWALL 92 CONTINUOUS 0.35 RETAINING WALL
S_PR_RETWALL10 RED CONTINUOUS 0.10 RETAINING WALL
S_PR_RETWALL10H RED HIDDEN 0.10 RETAINING WALL
S_PR_RETWALL25 WHITE CONTINUOUS 0.25 RETAINING WALL
S_PR_RETWALL25H WHITE HIDDEN 0.25 RETAINING WALL
S_PR_RETWALL35 GREEN CONTINUOUS 0.35 RETAINING WALL
S_PR_RETWALL50 CYAN CONTINUOUS 0.50 RETAINING WALL
ROCK DISTINCTLY
S_PR_ROCK_ DW10PH RED PHANTOM 0.10
WEATHERED

Page 169 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_ROCK_
RED DASHDOT2 0.10 ROCK SLIGHTLY WEATHERED
SW10DD2
S_PR_ROCK_
RED PHANTOM 0.10 ROCK EXTREMELY WEATHERED
XW10DI
S_PR_ROOF10 RED CONTINUOUS 0.10 ROOF
S_PR_ROOF10H RED HIDDEN 0.10 ROOF
S_PR_ROOF25 WHITE CONTINUOUS 0.25 ROOF
S_PR_ROOF25H WHITE HIDDEN 0.25 ROOF
S_PR_ROOF35 GREEN CONTINUOUS 0.35 ROOF
S_PR_ROOF50 CYAN CONTINUOUS 0.50 ROOF
S_PR_RSS10 RED CONTINUOUS 0.10 REINFORCED SOIL STRUCTURE
S_PR_RSS10H RED HIDDEN 0.10 REINFORCED SOIL STRUCTURE
S_PR_RSS25 WHITE CONTINUOUS 0.25 REINFORCED SOIL STRUCTURE
S_PR_RSS35 GREEN CONTINUOUS 0.35 REINFORCED SOIL STRUCTURE
S_PR_RSS50 CYAN CONTINUOUS 0.50 REINFORCED SOIL STRUCTURE
SOUTHBOUND SLIP ROAD
S_PR_SB_SLIPRD 212 CONTINUOUS 0.35
PROFILE
S_PR_SC RED CONTINUOUS 0.10 SERVICE CORRIDOR
S_PR_SECTION 133 CONTINUOUS 0.35 SECTION
S_PR_SERVICES25 WHITE CONTINUOUS 0.25 SERVICES
S_PR_SERVICES25H WHITE HIDDEN 0.25 SERVICES
S_PR_SERVICES35 GREEN CONTINUOUS 0.35 SERVICES
S_PR_SERVICES50 CYAN CONTINUOUS 0.50 SERVICES
S_PR_SOP GREEN CONTINUOUS 0.35 SET-OUT POINT
S_PR_SPRAY_WP CYAN HIDDEN 0.50 WATER PROOFING LINE

Page 170 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight
S_PR_STAIR10H RED HIDDEN 0.10 STAIR
S_PR_STAIR25 WHITE CONTINUOUS 0.25 STAIR
S_PR_STAIR25H WHITE HIDDEN 0.25 STAIR
S_PR_STAIR35 GREEN CONTINUOUS 0.35 STAIR
S_PR_STAIR50 RED CONTINUOUS 0.10 STAIR
S_PR_STEEL10 RED CONTINUOUS 0.10 STEEL
S_PR_STEEL10C RED CENTER 0.10 STEEL
S_PR_STEEL10H RED HIDDEN 0.10 STEEL
S_PR_STEEL13C2 9 CENTER2 0.15 STEEL
S_PR_STEEL25 WHITE CONTINUOUS 0.25 STEEL
S_PR_STEEL25H WHITE HIDDEN 0.25 STEEL
S_PR_STEEL35 GREEN CONTINUOUS 0.35 STEEL
S_PR_STEEL50 CYAN CONTINUOUS 0.50 STEEL
S_PR_TAPERPLATE10 RED CONTINUOUS 0.10 TAPER PLATE
S_PR_TAPERPLATE10H RED HIDDEN 0.10 TAPER PLATE
S_PR_TAPERPLATE25 WHITE CONTINUOUS 0.25 TAPER PLATE
S_PR_TENDON10 RED CONTINUOUS 0.10 TENDON
S_PR_TENDON10C RED CENTER 0.10 TENDON
S_PR_TENDON10H RED HIDDEN 0.10 TENDON
S_PR_TENDON10H2 RED HIDDEN2 0.10 TENDON
S_PR_TENDON13C2 9 CENTER2 0.15 TENDON
S_PR_TENDON20 20 CONTINUOUS 0.35 TENDON
S_PR_TENDON25 WHITE CONTINUOUS 0.25 TENDON
S_PR_TENDON30 30 CONTINUOUS 0.35 TENDON
S_PR_TENDON35 GREEN CONTINUOUS 0.35 TENDON
S_PR_TENDON50 CYAN CONTINUOUS 0.50 TENDON

Page 171 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_TENDON90 90 CONTINUOUS 0.35 TENDON


S_PR_TENDON130 130 CONTINUOUS 0.35 TENDON
S_PR_TENDON170 170 CONTINUOUS 0.35 TENDON
S_PR_TENDON210 210 CONTINUOUS 0.35 TENDON
S_PR_WALL10 RED CONTINUOUS 0.10 WALL
S_PR_WALL10H RED HIDDEN 0.10 WALL
S_PR_WALL25 WHITE CONTINUOUS 0.25 WALL
S_PR_WALL25H WHITE HIDDEN 0.25 WALL
S_PR_WALL35 GREEN CONTINUOUS 0.35 WALL
S_PR_WALL50 CYAN CONTINUOUS 0.50 WALL
S_PR_WATER PROOF WHITE CONTINUOUS 0.25 WATER PROOF
S_PR_WATER PROOFH WHITE HIDDEN 0.25 WATER PROOF HIDDEN
CONSTRUCTION JOINT,PARTIAL
S_PR_WATER
CONSTRUCTION JOINT &
PROOF_CJ_PCJ_KCJ_W 251 DASHDOT2 0.15
KICKER CONSTRUCTION JOINT
TR_AR31
WATER BAR -AR 31
S_PR_WATER PROOF COMPARTMENT WATER BAR -
222 DASHDOT2 0.35
_COMPNT_WTR_AR31 AR 31
S_PR_WATER PROOF CRACK INDUCER INJECTION
251 CONTINUOUS 0.15
_CRAK_INDUCER_BOX BOX
S_PR_WATER PROOF
CRACK INDUCER INJECTION
_CRAK_INDUCER_FLO 30 CONTINUOUS 0.35
BOX FLOOR MOUNTED
OR_MONDBOX
S_PR_WATER PROOF
40 CONTINUOUS 0.35 RASCOR CRACK INDUCER
_CRAK_INDUCER
S_PR_WATER PROOF
246 CONTINUOUS 0.35 SIKA DILATEC E-220
_DILATEC

Page 172 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_WATER EXPANSION JOINT


44 CONTINUOUS 0.35
PROOF_EJ_WTR_DR32 WATER BAR - DR 32

S_PR_WATER PROOF_FUKO 10 CONTINUOUS 0.60 SIKA FUKO VT1

S_PR_WATER GEOTEXTILE
Cyan DIVIDE 0.50
PROOF_GEOTEXT SEPARATION LAYER
S_PR_WATER RASCOR INJECTION
224 FENCELINE1 0.35
PROOF_INDUCER_INJ_HOSE HOSE
S_PR_WATER INJECTION BOX FLOOR
30 CONTINUOUS 0.35
PROOF_INJ_BOX_FLR_MUND MOUNTED

S_PR_WATER
170 CONTINUOUS 0.35 INJECTION BOX
PROOF_INJ_BOX
S_PR_WATER FLANGE INJECTION
84 CONTINUOUS 0.35
PROOF_INJ_FLANGE_HOSE HOSE
S_PR_WATER
32 CONTINUOUS 0.35 INJECTION FLANGE
PROOF_INJ_FLANGE
SIKA FUKO VT1
S_PR_WATER
162 TRACKS 0.35 INJECTION HOSE
PROOF_INJ_HOSE
(CONNECTION HOSE)
S_PR_WATER
44 CONTINUOUS 0.35 INTERNAL WATER BAR
PROOF_INTRN_WTRBR
S_PR_WATER PVC WATERPROOFING
8 DASHED 0.20
PROOF_MEMBRNE MEMBRANE
S_PR_WATER WATER PROOFING
Cyan DASHDOT2 0.50
PROOF_PRO_BORD PROTECTION BOARD
S_PR_WATER
136 DASHDOT2 0.35 TERMINATION BAR
PROOF_TERMI_BAR

Page 173 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

PROPOSED STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_PR_WATER
183 CONTINUOUS 0.35 UPPER SIKA FUKO VT1
PROOF_UPPER_FUKO
S_PR_WIPEOUT 255 CONTINUOUS 0.15 WIPE OUT
S_PR_XCLIP 103 CONTINUOUS 0.35 XREF CLIP

EXISTING STRUCTURAL LAYERS


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_ABUTMENT_BARRIER10 RED CONTINUOUS 0.10 ABUTMENT BARRIER


S_EX_ABUTMENT_BARRIER10 RED HIDDEN 0.10 ABUTMENT BARRIER
H
S_EX_ABUTMENT_BARRIER25 WHITE CONTINUOUS 0.25 ABUTMENT BARRIER
S_EX_ABUTMENT_BARRIER25 WHITE HIDDEN 0.25 ABUTMENT BARRIER
H
S_EX_ABUTMENT_BARRIER35 GREEN CONTINUOUS 0.35 ABUTMENT BARRIER
S_EX_ABUTMENT_BARRIER50 CYAN CONTINUOUS 0.50 ABUTMENT BARRIER

S_EX_ABUTMENT_BEARING10 RED CONTINUOUS 0.10 ABUTMENT BEARING

S_EX_ABUTMENT_
RED HIDDEN 0.10 ABUTMENT BEARING
BEARING10H
S_EX_ABUTMENT_ ABUTMENT BEARING
RED CENTER 0.10
BEARINGSOL10C SET-OUT LINE

Page 174 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Plotted
Screen
Layer Name Linetype Line Description
Colour
Weight

S_EX_ABUTMENT_HATCH253 253 CONTINUOUS 0.15 ABUTMENT HATCH


S_EX_ABUTMENT_ ABUTMENT MORTAR
RED CONTINUOUS 0.10
MORTARPAD10 PAD
S_EX_ABUTMENT_PILE10C RED CENTER 0.10 ABUTMENT PILE
S_EX_ABUTMENT_PILE10H2 RED HIDDEN2 0.10 ABUTMENT PILE
S_EX_ABUTMENT_PILE25 WHITE CONTINUOUS 0.25 ABUTMENT PILE
S_EX_ABUTMENT_PILELINER10 RED CONTINUOUS 0.10 ABUTMENT PILE LINER
S_EX_ABUTMENT_PILELINER10H RED HIDDEN 0.10 ABUTMENT PILE LINER
S_EX_ABUTMENT_PILELINER25 WHITE CONTINUOUS 0.25 ABUTMENT PILE LINER
S_EX_ABUTMENT_PILELINER25H WHITE HIDDEN 0.25 ABUTMENT PILE LINER
S_EX_ABUTMENT_PILELINER35 GREEN CONTINUOUS 0.35 ABUTMENT PILE LINER
S_EX_ABUTMENT_PILELINER50 CYAN CONTINUOUS 0.50 ABUTMENT PILE LINER
ABUTMENT SET-OUT
S_EX_ABUTMENT_SOL10C RED CENTER 0.10
LINE
S_EX_ABUTMENT 10 RED CONTINUOUS 0.10 ABUTMENT
S_EX_ABUTMENT 10H RED HIDDEN 0.10 ABUTMENT
S_EX_ABUTMENT25 WHITE CONTINUOUS 0.25 ABUTMENT
S_EX_ABUTMENT25H WHITE HIDDEN 0.25 ABUTMENT
S_EX_ABUTMENT35 GREEN CONTINUOUS 0.35 ABUTMENT
S_EX_ABUTMENT50 CYAN CONTINUOUS 0.50 ABUTMENT
S_EX_ANCHOR10 RED CONTINUOUS 0.10 ANCHOR
S_EX_ANCHOR10C RED CENTER 0.10 ANCHOR
S_EX_ANCHOR10H RED HIDDEN 0.10 ANCHOR
S_EX_ANCHOR13C2 9 CENTER2 0.15 ANCHOR
S_EX_ANCHOR25 WHITE CONTINUOUS 0.25 ANCHOR

Page 175 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight
S_EX_ANCHOR25H WHITE HIDDEN 0.25 ANCHOR
S_EX_ANCHOR35 WHITE CONTINUOUS 0.25 ANCHOR
S_EX_ANCHOR50 RED CONTINUOUS 0.10 ANCHOR
S_EX_APPSL RED CONTINUOUS 0.10 APPROACH SLAB
S_EX_BARRIER 200 CONTINUOUS 0.35 BARRIER
S_EX_BARRIER_JOINT RED CONTINUOUS 0.10 BARRIER JOINT
S_EX_BARRIER10 RED CONTINUOUS 0.10 BARRIER
S_EX_BARRIER10H RED HIDDEN 0.10 BARRIER
S_EX_BARRIER25 WHITE CONTINUOUS 0.25 BARRIER
S_EX_BARRIER25H WHITE HIDDEN 0.25 BARRIER
S_EX_BARRIER35 GREEN CONTINUOUS 0.35 BARRIER
S_EX_BARRIER50 CYAN CONTINUOUS 0.50 BARRIER
S_EX_BASE10 RED CONTINUOUS 0.10 BASE
S_EX_BASE10H RED HIDDEN 0.10 BASE
S_EX_BASE25 WHITE CONTINUOUS 0.25 BASE
S_EX_BASE25H WHITE HIDDEN 0.25 BASE
S_EX_BASE35 GREEN CONTINUOUS 0.35 BASE
S_EX_BASE50 RED CONTINUOUS 0.10 BASE
S_EX_BATTER10 RED CONTINUOUS 0.10 BATTER
S_EX_BATTER10D RED DASHED 0.10 BATTER
S_EX_BATTER10H RED HIDDEN 0.10 BATTER
S_EX_BATTER25 WHITE CONTINUOUS 0.25 BATTER
S_EX_BATTER25H WHITE HIDDEN 0.25 BATTER
S_EX_BATTER35 GREEN CONTINUOUS 0.35 BATTER
S_EX_BATTER50 CYAN CONTINUOUS 0.50 BATTER

S_EX_BLINDING18 RED CONTINUOUS 0.18 BLINDING CONCRETE

Page 176 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_BOREHOLE25 WHITE CONTINUOUS 0.25 BOREHOLE


S_EX_BOREHOLE35 GREEN CONTINUOUS 0.35 BOREHOLE
S_EX_CAPPING-BEAM10 RED CONTINUOUS 0.10 CAPPING BEAM
S_EX_CAPPING-BEAM10H RED HIDDEN 0.10 CAPPING BEAM
S_EX_CAPPING-BEAM25 WHITE CONTINUOUS 0.25 CAPPING BEAM
S_EX_CAPPING-BEAM25H WHITE HIDDEN 0.25 CAPPING BEAM
S_EX_CAPPING-BEAM35 GREEN CONTINUOUS 0.35 CAPPING BEAM
S_EX_CAPPING-BEAM50 CYAN CONTINUOUS 0.50 CAPPING BEAM
S_EX_CAST-IN10 RED CONTINUOUS 0.10 CAST-IN
S_EX_CAST-IN10H RED HIDDEN 0.10 CAST-IN
S_EX_CAST-IN13C2 9 CENTER2 0.15 CAST-IN
S_EX_CAST-IN25 WHITE CONTINUOUS 0.25 CAST-IN
S_EX_CAST-IN25H WHITE HIDDEN 0.25 CAST-IN
S_EX_CAST-IN35 GREEN CONTINUOUS 0.35 CAST-IN
S_EX_CAST-IN50 CYAN CONTINUOUS 0.50 CAST-IN
S_EX_CJ1 RED CJ1 0.10 CONSTRUCTION JOINT
S_EX_CJ2 RED CJ2 0.10 CONSTRUCTION JOINT
S_EX_CLADDING10 RED CONTINUOUS 0.10 CLADDING
S_EX_CLADDING10H RED HIDDEN 0.10 CLADDING
S_EX_CLADDING25 WHITE CONTINUOUS 0.25 CLADDING
S_EX_COLUMN10 RED CONTINUOUS 0.10 COLUMN
S_EX_COLUMN10C RED CENTER 0.10 COLUMN
S_EX_COLUMN10H RED HIDDEN 0.10 COLUMN
S_EX_COLUMN25 WHITE CONTINUOUS 0.25 COLUMN
S_EX_COLUMN25H WHITE HIDDEN 0.25 COLUMN

Page 177 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_COLUMN35 GREEN CONTINUOUS 0.35 COLUMN


S_EX_COLUMN50 CYAN CONTINUOUS 0.50 COLUMN
S_EX_CONC10 RED CONTINUOUS 0.10 CONCRETE
S_EX_CONC10H RED HIDDEN 0.10 CONCRETE
S_EX_CONC18C RED CENTER 0.18 CONCRETE
S_EX_CONC25 WHITE CONTINUOUS 0.25 CONCRETE
S_EX_CONC25H WHITE HIDDEN 0.25 CONCRETE
S_EX_CONC35 GREEN CONTINUOUS 0.35 CONCRETE
S_EX_CONC50 CYAN CONTINUOUS 0.50 CONCRETE
S_EX_CONDUIT10 RED CONTINUOUS 0.10 CONDUIT
S_EX_CONDUIT10C RED CENTER 0.10 CONDUIT
S_EX_CONDUIT10H RED HIDDEN 0.10 CONDUIT
S_EX_CONDUIT13C2 9 CENTER2 0.15 CONDUIT
S_EX_CONDUIT25 WHITE CONTINUOUS 0.25 CONDUIT
S_EX_CONDUIT25H WHITE CONTINUOUS 0.25 CONDUIT
S_EX_CONDUIT35 GREEN CONTINUOUS 0.35 CONDUIT
S_EX_CONDUIT50 CYAN CONTINUOUS 0.50 CONDUIT
S_EX_CONTROL RED CENTER 0.10 CONTROL LINE
S_EX_COVERPLATE10 RED CONTINUOUS 0.10 COVERPLATE
S_EX_COVERPLATE10H RED HIDDEN 0.10 COVERPLATE
S_EX_COVERPLATE13C2 9 CENTER2 0.15 COVERPLATE
S_EX_COVERPLATE25 WHITE CONTINUOUS 0.25 COVERPLATE
S_EX_COVERPLATE25H WHITE HIDDEN 0.25 COVERPLATE
S_EX_COVERPLATE35 GREEN CONTINUOUS 0.35 COVERPLATE
S_EX_COVERPLATE50 CYAN CONTINUOUS 0.50 COVERPLATE

Page 178 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_DECK_CJ1 RED CJ1 0.10 DECK


S_EX_DECK_DIAPHRAGM10H RED HIDDEN 0.10 CONSTRUCTION
DECK DIAPHRAGM

S_EX_DECK_DIAPHRAGM25H WHITE HIDDEN 0.25 JOINT


DECK DIAPHRAGM

S_EX_DECK_SOFFIT10H RED HIDDEN 0.10 DECK SOFFIT


S_EX_DECK_SOFFIT25 WHITE CONTINUOUS 0.25 DECK SOFFIT
S_EX_DECK_SOFFIT35 GREEN CONTINUOUS 0.35 DECK SOFFIT
S_EX_DECK10 RED CONTINUOUS 0.10 DECK
S_EX_DECK10H RED HIDDEN 0.10 DECK
S_EX_DECK25 WHITE CONTINUOUS 0.25 DECK
S_EX_DECK25H WHITE HIDDEN 0.25 DECK
S_EX_DECK35 GREEN CONTINUOUS 0.35 DECK
S_EX_DECK50 CYAN CONTINUOUS 0.50 DECK
S_EX_DIAPHRAGM_WALL10 RED CONTINUOUS 0.10 DIAPHRAGM WALL
S_EX_DIAPHRAGM_WALL10H RED HIDDEN 0.10 DIAPHRAGM WALL
S_EX_DIAPHRAGM_WALL25 WHITE CONTINUOUS 0.25 DIAPHRAGM WALL
S_EX_DIAPHRAGM_WALL25H WHITE HIDDEN 0.25 DIAPHRAGM WALL
S_EX_DIAPHRAGM_WALL35 GREEN CONTINUOUS 0.35 DIAPHRAGM WALL
S_EX_DIAPHRAGM_WALL50 CYAN CONTINUOUS 0.50 DIAPHRAGM WALL
S_EX_DOWELBAR40 CYAN CONTINUOUS 0.50 DOWEL BARS
S_EX_DRAINAGE10 RED CONTINUOUS 0.10 DRAINAGE
S_EX_DRAINAGE10C RED CENTER 0.10 DRAINAGE
S_EX_DRAINAGE10H RED HIDDEN 0.10 DRAINAGE
S_EX_DRAINAGE13C2 9 CENTER2 0.15 DRAINAGE
S_EX_DRAINAGE25 WHITE CONTINUOUS 0.25 DRAINAGE
S_EX_DRAINAGE25H WHITE HIDDEN 0.25 DRAINAGE

Page 179 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_DRAINAGE35 GREEN CONTINUOUS 0.35 DRAINAGE


S_EX_DRAINAGE50 CYAN CONTINUOUS 0.50 DRAINAGE
S_EX_EXPANSIONJOINT10 RED CONTINUOUS 0.10 EXPANSION JOINT
S_EX_EXPANSIONJOINT10C RED CENTER 0.10 EXPANSION JOINT
S_EX_EXPANSIONJOINT10H RED HIDDEN 0.10 EXPANSION JOINT
S_EX_EXPANSIONJOINT13C2 9 CENTER2 0.15 EXPANSION JOINT
S_EX_EXPANSIONJOINT25 WHITE CONTINUOUS 0.25 EXPANSION JOINT
S_EX_EXPANSIONJOINT25H WHITE HIDDEN 0.25 EXPANSION JOINT
S_EX_EXPANSIONJOINT35 GREEN CONTINUOUS 0.35 EXPANSION JOINT
S_EX_EXPANSIONJOINT50 CYAN CONTINUOUS 0.50 EXPANSION JOINT
S_EX_FC RED CONTINUOUS 0.10 FIRE CABINET ON PLAN
S_EX_FIREBOARD CYAN HIDDEN 0.50 FIRE BOARD PROTECTION
S_EX_FLOOR10 RED CONTINUOUS 0.10 FLOOR
S_EX_FLOOR10H RED HIDDEN 0.10 FLOOR
S_EX_FLOOR25 WHITE CONTINUOUS 0.25 FLOOR
S_EX_FLOOR25H WHITE HIDDEN 0.25 FLOOR
S_EX_FLOOR35 GREEN CONTINUOUS 0.35 FLOOR
S_EX_FLOOR50 CYAN CONTINUOUS 0.50 FLOOR
S_EX_FOOTING10 RED CONTINUOUS 0.10 FOOTING
S_EX_FOOTING10H RED HIDDEN 0.10 FOOTING
S_EX_FOOTING25 WHITE CONTINUOUS 0.25 FOOTING
S_EX_FOOTING25H WHITE HIDDEN 0.25 FOOTING
S_EX_FOOTING35 GREEN CONTINUOUS 0.35 FOOTING
S_EX_FOOTING50 CYAN CONTINUOUS 0.50 FOOTING

S_EX_FSL RED CONTINUOUS 0.10 FINISHED SURFACE LEVEL

Page 180 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_GIRDER_SOFFIT10H RED HIDDEN 0.10 GIRDER SOFFIT


S_EX_GIRDER_SOFFIT25 WHITE CONTINUOUS 0.25 GIRDER SOFFIT
S_EX_GIRDER_SOFFIT25C WHITE CENTER 0.25 GIRDER SOFFIT
S_EX_GIRDER_TOP10C RED CENTER 0.10 GIRDER TOP
S_EX_GIRDER10 RED CONTINUOUS 0.10 GIRDER
S_EX_GIRDER10C RED CENTER 0.10 GIRDER
S_EX_GIRDER10H RED HIDDEN 0.10 GIRDER
S_EX_GIRDER25 WHITE CONTINUOUS 0.25 GIRDER
S_EX_GIRDER25H WHITE HIDDEN 0.25 GIRDER
S_EX_GIRDER35 GREEN CONTINUOUS 0.35 GIRDER
S_EX_GIRDER50 CYAN CONTINUOUS 0.50 GIRDER
S_EX_HATCH 250 CONTINUOUS 0.15 HATCH
S_EX_HATCH_SAND WHITE CONTINUOUS 0.25 SAND COLOUR

S_EX_HATCH120 120 CONTINUOUS 0.35 SHADE 120


S_EX_HATCH251 251 CONTINUOUS 0.15 SHADE 251
S_EX_HATCH252 252 CONTINUOUS 0.15 SHADE 252
S_EX_HATCH253 253 CONTINUOUS 0.15 HATCH 253
S_EX_HATCH254 254 CONTINUOUS 0.15 SHADE 254
S_EX_HATCH255 255 CONTINUOUS 0.15 SHADE 255
S_EX_HATCH81 81 CONTINUOUS 0.35 SHADE 81
S_EX_HATCH253-BNDY 40 CONTINUOUS 0.35 HATCH BOUNDARY
S_EX_KERB RED CONTINUOUS 0.10 KERBS ON PLAN
S_EX_KERB10 RED CONTINUOUS 0.10 KERB
S_EX_KERB25 WHITE CONTINUOUS 0.25 KERB
S_EX_KERB35 GREEN CONTINUOUS 0.35 KERB

Page 181 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_KERB50 CYAN CONTINUOUS 0.50 KERB


S_EX_LAMP10 RED CONTINUOUS 0.10 LAMP
S_EX_LAMP10H RED HIDDEN 0.10 LAMP
S_EX_LAMP25 WHITE CONTINUOUS 0.25 LAMP
S_EX_LAMP25H WHITE HIDDEN 0.25 LAMP
S_EX_LAMP35 GREEN CONTINUOUS 0.35 LAMP
S_EX_LAMP50 CYAN CONTINUOUS 0.50 LAMP
S_EX_MATCHLINE BLUE CENTER 0.70 MATCHLINE
NORTHBOUND SLIP
S_EX_NB_SLIPRD 152 CONTINUOUS 0.35
ROAD PROFILE
S_EX_MISC25 WHITE CONTINUOUS 0.25 MISC
NATURAL GROUND
S_EX_NGL RED CONTINUOUS 0.10
LEVEL
S_EX_PANEL10 RED CONTINUOUS 0.10 PANEL
S_EX_PANEL10H RED HIDDEN 0.10 PANEL
S_EX_PANEL25 WHITE CONTINUOUS 0.25 PANEL
S_EX_PANEL35 GREEN CONTINUOUS 0.35 PANEL
S_EX_PANEL50 CYAN CONTINUOUS 0.50 PANEL
PARTIAL
S_EX_PCJ18 RED HIDDEN 0.18
CONTRACTION JOINT
S_EX_PIER_BEARING10 RED CONTINUOUS 0.10 PIER BEARING
S_EX_PIER_BEARING10H RED HIDDEN 0.10 PIER BEARING
S_EX_PIER_BEARINGSOL10 PIER BEARING SET-
RED CENTER 0.10
C OUT LINE
S_EX_PIER_COLUMN10 RED CONTINUOUS 0.10 PIER COLUMN

Page 182 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_PIER_COLUMN10C RED CENTER 0.10 PIER COLUMN


S_EX_PIER_COLUMN10H RED HIDDEN 0.10 PIER COLUMN
S_EX_PIER_COLUMN25 WHITE CONTINUOUS 0.25 PIER COLUMN
S_EX_PIER_COLUMN25H WHITE HIDDEN 0.25 PIER COLUMN
S_EX_PIER_COLUMN35 GREEN CONTINUOUS 0.35 PIER COLUMN
S_EX_PIER_COLUMN50 CYAN CONTINUOUS 0.50 PIER COLUMN
S_EX_PIER_FOOTING25 WHITE CONTINUOUS 0.25 PIER FOOTING
S_EX_PIER_FOOTING35 GREEN CONTINUOUS 0.35 PIER FOOTING
S_EX_PIER_HATCH253 253 CONTINUOUS 0.15 PIER HATCH
S_EX_PIER_HEADSTOCK10 RED CONTINUOUS 0.10 PIER HEADSTOCK
S_EX_PIER_HEADSTOCK10H RED HIDDEN 0.10 PIER HEADSTOCK
S_EX_PIER_HEADSTOCK25 WHITE CONTINUOUS 0.25 PIER HEADSTOCK
S_EX_PIER_HEADSTOCK25H WHITE HIDDEN 0.25 PIER HEADSTOCK
S_EX_PIER_HEADSTOCK35 GREEN CONTINUOUS 0.35 PIER HEADSTOCK
S_EX_PIER_HEADSTOCK50 CYAN CONTINUOUS 0.50 PIER HEADSTOCK
S_EX_PIER_MORTARPAD10 RED CONTINUOUS 0.10 PIER MORTAR PAD
S_EX_PIER_PILE10C RED CENTER 0.10 PIER PILE
S_EX_PIER_PILE10H2 RED HIDDEN2 0.10 PIER PILE
S_EX_PIER_PILE25 WHITE CONTINUOUS 0.25 PIER PILE
S_EX_PIER_PILECAP10 RED CONTINUOUS 0.10 PIER PILECAP
S_EX_PIER_PILECAP10H RED HIDDEN 0.10 PIER PILECAP
S_EX_PIER_PILECAP25 WHITE CONTINUOUS 0.25 PIER PILECAP
S_EX_PIER_PILECAP25H WHITE HIDDEN 0.25 PIER PILECAP
S_EX_PIER_PILECAP35 GREEN CONTINUOUS 0.35 PIER PILECAP
S_EX_PIER_PILECAP50 CYAN CONTINUOUS 0.50 PIER PILECAP

Page 183 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_PIER_PILESOL10C RED CENTER 0.10 PIER PILE SETOUT LINE


S_EX_PIER_SOL10C RED CENTER 0.10 PIER SETOUT LINE
S_EX_PIER10 RED CONTINUOUS 0.10 PIER
S_EX_PIER10H RED HIDDEN 0.10 PIER
S_EX_PIER25 WHITE CONTINUOUS 0.25 PIER
S_EX_PIER25H WHITE HIDDEN 0.25 PIER
S_EX_PIER35 GREEN CONTINUOUS 0.35 PIER
S_EX_PIER50 CYAN CONTINUOUS 0.50 PIER
S_EX_RAIL_HD GREEN CONTINUOUS 0.35 RAIL
S_EX_RAIL10 RED CONTINUOUS 0.10 RAIL
S_EX_RAIL10C RED CENTER 0.10 RAIL
S_EX_RAIL10H RED HIDDEN 0.10 RAIL
S_EX_RAIL13C2 9 CENTER2 0.15 RAIL
S_EX_RAIL25 WHITE CONTINUOUS 0.25 RAIL
S_EX_RAIL35 GREEN CONTINUOUS 0.35 RAIL
S_EX_RAIL50 CYAN CONTINUOUS 0.50 RAIL
S_EX_RELIEVINGSLAB_ RELIEVING SLAB
RED CONTINUOUS 0.10
EXPANSIONJOINT10 EXPANSION JOINT
S_EX_REINFT18H RED HIDDEN 0.18 REINFORCEMENT HIDDEN

S_EX_REINFT50 CYAN CONTINUOUS 0.50 REINFORCEMENT

S_EX_RELIEVINGSLAB_ RELIEVING SLAB


9 CONTINUOUS 0.15
EXPANSIONJOINT13 EXPANSION JOINT

S_EX_RELIEVINGSLAB_ RELIEVING SLAB


WHITE CONTINUOUS 0.25
EXPANSIONJOINT25 EXPANSION JOINT

S_EX_RELIEVINGSLAB10 RED CONTINUOUS 0.10 RELIEVING SLAB

Page 184 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_RELIEVINGSLAB10H RED HIDDEN 0.10 RELIEVING SLAB


S_EX_RELIEVINGSLAB13H 9 HIDDEN 0.15 RELIEVING SLAB
S_EX_RELIEVINGSLAB25 WHITE CONTINUOUS 0.25 RELIEVING SLAB
S_EX_RELIEVINGSLAB25H WHITE HIDDEN 0.25 RELIEVING SLAB
S_EX_RELIEVINGSLAB35 GREEN CONTINUOUS 0.35 RELIEVING SLAB
S_EX_RELIEVINGSLAB50 CYAN CONTINUOUS 0.50 RELIEVING SLAB
S_EX_REO10 RED CONTINUOUS 0.10 REO
S_EX_REO10H RED HIDDEN 0.10 REO
S_EX_REO25 WHITE CONTINUOUS 0.25 REO
S_EX_REO252 252 CONTINUOUS 0.15 REO
S_EX_REO25H WHITE HIDDEN 0.25 REO
S_EX_REO35 GREEN CONTINUOUS 0.35 REO
S_EX_REO35H GREEN HIDDEN 0.35 REO
S_EX_REO50 CYAN CONTINUOUS 0.50 REO
S_EX_REO50H CYAN HIDDEN 0.50 REO
S_EX_REO70 BLUE CONTINUOUS 0.70 REO
S_EX_RETWALL 92 CONTINUOUS 0.35 RETAINING WALL
S_EX_RETWALL10 RED CONTINUOUS 0.10 RETAINING WALL
S_EX_RETWALL10H RED HIDDEN 0.10 RETAINING WALL
S_EX_RETWALL25 WHITE CONTINUOUS 0.25 RETAINING WALL
S_EX_RETWALL25H WHITE HIDDEN 0.25 RETAINING WALL
S_EX_RETWALL35 GREEN CONTINUOUS 0.35 RETAINING WALL
S_EX_RETWALL50 CYAN CONTINUOUS 0.50 RETAINING WALL
ROCK DISTINCTLY
S_EX_ROCK_ DW10PH RED PHANTOM 0.10
WEATHERED

Page 185 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_ROCK_
RED DASHDOT2 0.10 ROCK SLIGHTLY WEATHERED
SW10DD2
S_EX_ROCK_
RED PHANTOM 0.10 ROCK EXTREMELY WEATHERED
XW10DI
S_EX_ROOF10 RED CONTINUOUS 0.10 ROOF
S_EX_ROOF10H RED HIDDEN 0.10 ROOF
S_EX_ROOF25 WHITE CONTINUOUS 0.25 ROOF
S_EX_ROOF25H WHITE HIDDEN 0.25 ROOF
S_EX_ROOF35 GREEN CONTINUOUS 0.35 ROOF
S_EX_ROOF50 CYAN CONTINUOUS 0.50 ROOF
S_EX_RSS10 RED CONTINUOUS 0.10 REINFORCED SOIL STRUCTURE
S_EX_RSS10H RED HIDDEN 0.10 REINFORCED SOIL STRUCTURE
S_EX_RSS25 WHITE CONTINUOUS 0.25 REINFORCED SOIL STRUCTURE
S_EX_RSS35 GREEN CONTINUOUS 0.35 REINFORCED SOIL STRUCTURE
S_EX_RSS50 CYAN CONTINUOUS 0.50 REINFORCED SOIL STRUCTURE
SOUTHBOUND SLIP ROAD
S_EX_SB_SLIPRD 212 CONTINUOUS 0.35
PROFILE
S_EX_SC RED CONTINUOUS 0.10 SERVICE CORRIDOR
S_EX_SECTION 133 CONTINUOUS 0.35 SECTION
S_EX_SERVICES25 WHITE CONTINUOUS 0.25 SERVICES
S_EX_SERVICES25H WHITE HIDDEN 0.25 SERVICES
S_EX_SERVICES35 GREEN CONTINUOUS 0.35 SERVICES
S_EX_SERVICES50 CYAN CONTINUOUS 0.50 SERVICES
S_EX_SOP GREEN CONTINUOUS 0.35 SET-OUT POINT
S_EX_SPRAY_WP CYAN HIDDEN 0.50 WATER PROOFING LINE

Page 186 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight
S_EX_STAIR10H RED HIDDEN 0.10 STAIR
S_EX_STAIR25 WHITE CONTINUOUS 0.25 STAIR
S_EX_STAIR25H WHITE HIDDEN 0.25 STAIR
S_EX_STAIR35 GREEN CONTINUOUS 0.35 STAIR
S_EX_STAIR50 RED CONTINUOUS 0.10 STAIR
S_EX_STEEL10 RED CONTINUOUS 0.10 STEEL
S_EX_STEEL10C RED CENTER 0.10 STEEL
S_EX_STEEL10H RED HIDDEN 0.10 STEEL
S_EX_STEEL13C2 9 CENTER2 0.15 STEEL
S_EX_STEEL25 WHITE CONTINUOUS 0.25 STEEL
S_EX_STEEL25H WHITE HIDDEN 0.25 STEEL
S_EX_STEEL35 GREEN CONTINUOUS 0.35 STEEL
S_EX_STEEL50 CYAN CONTINUOUS 0.50 STEEL
S_EX_TAPERPLATE10 RED CONTINUOUS 0.10 TAPER PLATE
S_EX_TAPERPLATE10H RED HIDDEN 0.10 TAPER PLATE
S_EX_TAPERPLATE25 WHITE CONTINUOUS 0.25 TAPER PLATE
S_EX_TENDON10 RED CONTINUOUS 0.10 TENDON
S_EX_TENDON10C RED CENTER 0.10 TENDON
S_EX_TENDON10H RED HIDDEN 0.10 TENDON
S_EX_TENDON10H2 RED HIDDEN2 0.10 TENDON
S_EX_TENDON13C2 9 CENTER2 0.15 TENDON
S_EX_TENDON20 20 CONTINUOUS 0.35 TENDON
S_EX_TENDON25 WHITE CONTINUOUS 0.25 TENDON
S_EX_TENDON30 30 CONTINUOUS 0.35 TENDON
S_EX_TENDON35 GREEN CONTINUOUS 0.35 TENDON
S_EX_TENDON50 CYAN CONTINUOUS 0.50 TENDON

Page 187 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_TENDON90 90 CONTINUOUS 0.35 TENDON


S_EX_TENDON130 130 CONTINUOUS 0.35 TENDON
S_EX_TENDON170 170 CONTINUOUS 0.35 TENDON
S_EX_TENDON210 210 CONTINUOUS 0.35 TENDON
S_EX_WALL10 RED CONTINUOUS 0.10 WALL
S_EX_WALL10H RED HIDDEN 0.10 WALL
S_EX_WALL25 WHITE CONTINUOUS 0.25 WALL
S_EX_WALL25H WHITE HIDDEN 0.25 WALL
S_EX_WALL35 GREEN CONTINUOUS 0.35 WALL
S_EX_WALL50 CYAN CONTINUOUS 0.50 WALL
S_EX_WATER PROOF WHITE CONTINUOUS 0.25 WATER PROOF
S_EX_WATER PROOFH WHITE HIDDEN 0.25 WATER PROOF HIDDEN
CONSTRUCTION JOINT,PARTIAL
S_EX_WATER
CONSTRUCTION JOINT &
PROOF_CJ_PCJ_KCJ_W 251 DASHDOT2 0.15
KICKER CONSTRUCTION JOINT
TR_AR31
WATER BAR -AR 31
S_EX_WATER PROOF COMPARTMENT WATER BAR -
222 DASHDOT2 0.35
_COMPNT_WTR_AR31 AR 31
S_EX_WATER PROOF CRACK INDUCER INJECTION
251 CONTINUOUS 0.15
_CRAK_INDUCER_BOX BOX
S_EX_WATER PROOF
CRACK INDUCER INJECTION
_CRAK_INDUCER_FLO 30 CONTINUOUS 0.35
BOX FLOOR MOUNTED
OR_MONDBOX
S_EX_WATER PROOF
40 CONTINUOUS 0.35 RASCOR CRACK INDUCER
_CRAK_INDUCER
S_EX_WATER PROOF
246 CONTINUOUS 0.35 SIKA DILATEC E-220
_DILATEC

Page 188 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_WATER EXPANSION JOINT


44 CONTINUOUS 0.35
PROOF_EJ_WTR_DR32 WATER BAR - DR 32

S_EX_WATER PROOF_FUKO 10 CONTINUOUS 0.60 SIKA FUKO VT1

S_EX_WATER GEOTEXTILE
Cyan DIVIDE 0.50
PROOF_GEOTEXT SEPARATION LAYER
S_EX_WATER RASCOR INJECTION
224 FENCELINE1 0.35
PROOF_INDUCER_INJ_HOSE HOSE
S_EX_WATER INJECTION BOX FLOOR
30 CONTINUOUS 0.35
PROOF_INJ_BOX_FLR_MUND MOUNTED

S_EX_WATER
170 CONTINUOUS 0.35 INJECTION BOX
PROOF_INJ_BOX
S_EX_WATER FLANGE INJECTION
84 CONTINUOUS 0.35
PROOF_INJ_FLANGE_HOSE HOSE
S_EX_WATER
32 CONTINUOUS 0.35 INJECTION FLANGE
PROOF_INJ_FLANGE
SIKA FUKO VT1
S_EX_WATER
162 TRACKS 0.35 INJECTION HOSE
PROOF_INJ_HOSE
(CONNECTION HOSE)
S_EX_WATER
44 CONTINUOUS 0.35 INTERNAL WATER BAR
PROOF_INTRN_WTRBR
S_EX_WATER PVC WATERPROOFING
8 DASHED 0.20
PROOF_MEMBRNE MEMBRANE
S_EX_WATER WATER PROOFING
Cyan DASHDOT2 0.50
PROOF_PRO_BORD PROTECTION BOARD
S_EX_WATER
136 DASHDOT2 0.35 TERMINATION BAR
PROOF_TERMI_BAR

Page 189 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

EXISTING STRUCTURAL LAYERS (Continuation...)


Screen Plotted
Layer Name Linetype Description
Colour Line Weight

S_EX_WATER
183 CONTINUOUS 0.35 UPPER SIKA FUKO VT1
PROOF_UPPER_FUKO
S_EX_WIPEOUT 255 CONTINUOUS 0.15 WIPE OUT
S_EX_XCLIP 103 CONTINUOUS 0.35 XREF CLIP

Page 190 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix B – USEFUL TABLES FOR AUTOCAD

Page 191 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Useful tables for AutoCAD

Table 1 - Model Space Zoom XP Factors (Metres)

Scale of Drawing Zoom XP Scale


1 : 1000 1
1 : 1250 0.8
1 : 2500 0.4
1 : 5000 0.2
1 : 10000 0.1
1 : 25000 0.04
1 : 50000 0.02
1 : 500 2
1 : 200 5
1 : 100 10
1 : 50 20
1 : 20 50
1 : 10 100
1:5 200
1:2 500
1:1 1000

Table 2 – Model Space Zoom XP Factors (Millimetres)

Scale of Drawing Zoom XP Scale


1 : 500 0.002
1 : 200 0.005
1 : 100 0.01
1 : 50 0.02
1 : 20 0.05
1 : 10 0.1
1:5 0.2
1:2 0.5
1:1 1

Page 192 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

All text on drawings are to be produced in upper case only, unless specifically requested not
to do so (e.g. presentation drawings). Text sizes are to be relative to the scale of the drawing
as follows:

Table 3 – Text relation to drawing size (Millimetres)

Drawing Size Titles Pen Size General Text & Pen Size
Notes

A0 5mm 0.5mm 2.5mm 0.25mm


A1 5mm 0.5mm 2.5mm 0.25mm
A2 5mm 0.5mm 2.5mm 0.25mm
A3 3.5mm 0.35mm 2.5mm 0.25mm
A4 3.5mm 0.35mm 2.5mm 0.25mm

Table 4 - Text Heights for use in Model Space (Millimetres)

Scale of Factor Text Height

Drawing (Multiply) 0.25 Pen 0.35 Pen 0.5 Pen

1 : 500 500 1250.00 1750.00 2500.00


1 : 200 200 500.00 700.00 1000.00
1 : 100 100 250.00 350.00 500.00
1 : 50 50 125.00 175.00 250.00
1 : 20 20 50.00 70.00 100.00
1 : 10 10 25.00 35.00 50.00
1:5 5 12.50 17.50 25.00
1:2 2 5.00 7.00 10.00
1:1 1 2.50 3.50 5.00

Page 193 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Table 5 - Text Heights for use in Model Space (Metres)

Scale of Factor Text Height

Drawing (Multiply) 0.25 Pen 0.35 Pen 0.5 Pen

1 : 1000 1.00 2.50 3.50 5.00


1 : 1250 1.25 3.125 4.375 6.25
1 : 2500 2.5 6.25 8.75 12.50
1 : 5000 5.00 12.50 17.50 25.00
1 : 10000 10.00 25.00 35.00 50.00
1 : 25000 25.00 62.50 87.50 125.00
1 : 50000 50.00 125.00 175.00 250.00
1 : 500 0.50 1.25 1.75 2.50
1 : 200 0.20 0.50 0.70 1.00
1 : 100 0.10 0.25 0.35 0.50
1 : 50 0.05 0.125 0.175 0.25
1 : 20 0.02 0.05 0.07 0.10
1 : 10 0.01 0.025 0.035 0.05
1:5 0.005 0.0125 0.175 0.025
1:2 0.002 0.005 0.007 0.010
1:1 0.001 0.0025 0.0035 0.005

Page 194 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix C – DRAWING TYPE AND


DRAWING NUMBER SERIES

Page 195 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Drawing Type and Drawing Number Series

Drawing Type Title Series Number

General Layouts and miscellaneous drawings 0000 - 0249


SK –
Geotechnical 0250 - 0499
Sketch Drawings *
Highways 0500 - 0999

Site Clearance 1000 - 1499


*Sketches generally will
Traffic 1500 - 1999
contain preliminary graphics
Street Lighting 2000 - 2499
to illustrate a single point
Fencing 2500 - 2999
and will be prepared with
the intent of a single use. Road Restraint 3000 - 3499

Sketches may be used to Earthworks 3500 - 3999

present a general design Grading 4000 - 4499

concept, or may be included Structures 4500 - 4999

with instruction for Utility Services Corridors 5000 - 5499

clarification in Surface Water 5500 - 5999


correspondence. The SK Foul Sewer 6000 - 6499
designation will not be used Treated Sewage Effluent 6500 - 6999
beyond this one-time use. If Potable Water 7000 - 7499
incorporated into a design Fire Water 7500 - 7999
drawing set the drawing Electricity 8000 - 8499
designation must progress to
Telecommunications/ 8500 - 8999
its discipline specific
Doha Surveillance Security System 9000 - 9249
designation/purpose as
Environmental 9250 - 9499
below.
Landscape 9500 - 9999

General Notes, Abbreviations & Legends,


DS - 0001 - 0999
Location Plan, General Key Plan, etc.
Doha Surveillance Security
Doha Surveillance Security System Layout &
System 1000 - 1999
Key Plan

Page 196 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix C continued...

Drawing Type Title Series Number

DS - .....

Doha Surveillance Security Standard & Miscellaneous Details 7000 - 7999

System .....

General Notes, Abbreviations & Legends,


0001 - 0999
Location Plan, General Key Plan, etc.
ED - Earthworks Layout & Key Plan 1000 - 1999

Earthworks ……

Standard & Miscellaneous Details 7000 - 7999


.....
General Notes, Abbreviations & Legends,
0001 - 0999
Location Plan, General Key Plan, etc.
High Voltage Layout & Key Plan 1000 - 1999
EL - Medium Voltage Layout & Key Plan 2000 - 2999
Electricity Low Voltage & Key Plan 3000 - 3999
…..
Standard & Miscellaneous Details 7000 - 7999
.....

General Notes, Abbreviations & Legends,


0001 - 0999
Location Plan, General Key Plan, etc.
Existing Site Features 1000 - 1999

Sensitive Receptors 2000 - 2999


EN -
Surveys & Investigations 3000 - 3999
Environmental
Monitoring Locations 4000 - 4999
……
Standard & Miscellaneous Details 7000 - 7999
.....

Page 197 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix C continued...

Drawing Type Title Series Number

General Notes, Abbreviations & Legends, Location plan,


0001 - 0999
General Key Plan, etc.

FE - Fencing Layout & Key Plan 1000 - 1999

Fencing .....

Standard & Miscellaneous Details 7000 - 7999

.....
General Notes, Abbreviations & Legends, Location Plan,
0001 - 0999
General Key Plan, etc.

Fire Water Network 1000 - 1999


FI-
Longitudinal Sections (Profiles) 2000 - 2999
Fire Water
.....

Standard & Miscellaneous Details 7000- 7999


.....

General Notes, Abbreviations & Legends, Location Plan,


0001 - 0999
General Key Plan, etc.

Proposed Foul Sewer Layout & Key Plan 1000 - 1999


FS -
Longitudinal Sections (Profiles) 2000 - 2999
Foul Sewer
.....

Standard & Miscellaneous Details 7000 - 7999


.....

GE - Drawing Lists 0001 - 0999


General .....

General Notes, Abbreviations & Legends, Location Plan,


0001 - 0999
GR - General Key Plan, etc.
Grading Existing Grading and Topographic Survey Layout Plan &
1000 - 1999
Key Plan

Page 198 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix C continued...

Drawing Type Title Series Number

Proposed Grading Layout & Key Plan 2000 - 2999

GR - …..
Grading Standard & Miscellaneous Details 7000 - 7999
.....

General Notes, Abbreviations & Legends, Location plan, General


0001 - 0999
Key Plan, etc.
GT -
.....
Geotechnical
Standard & Miscellaneous Details 7000- 7999
.....
General Notes, Abbreviations & Legends, Location plan, General
Key Plan; District, Zone & Municipality Boundaries; Road Corridor 0001 - 0999
etc.
Proposed Road Layout Plan 1000 - 1999

Setting Out Plan (Horizontal Alignment Plan) 2000 - 2999

Road Profiles 3000 - 3999


HW -
Proposed Right of Ways Plans & Proposed Gate Levels 4000 - 4999
Highways
Junction Layout Plan and Levels 5000 - 5999

Cross Sections (Detailed and Typical) 6000 - 6999

Visibility Approach, Swept Path Analysis, Pavement Types, Standard


7000 - 7999
& Miscellaneous Details

Road Signs & Markings 8000 - 8999

Pavement Layout and Details 9000 - 9999

General Notes, Abbreviations & Legends, Location Plan, General Key


IS - Intelligent 0001 - 0999
Plan, etc.
Traffic Systems
ITS Layout & Keyplan (General Arrangement) 1000 - 1999

Page 199 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix C continued...

Drawing Type Title Series Number

……
IS - Intelligent
Standard & Miscellaneous Details 7000 - 7999
Traffic Systems
……

General Notes, Abbreviations & Legends, Location Plan,


0001 - 0999
General Key Plan, etc.
Landscape Layout & Key Plan (General Arrangement) 1000 - 1999
Hardscape 2000 - 2999

LE - Softscape 3000 - 3999


Landscape Grading & Levels 4000 - 4999
Landscape Furniture & Lighting 5000 - 5999
Irrigation (Mainline, Drip & Spray) 6000 - 6999
Standard & Miscellaneous Details 7000 - 7999
.....

LP - Land Land Expropriation and Encroachment Plan 0001 - 0999


Expropriation and
.....
Encroachment Plan
General Notes, Abbreviations & Legends, Location Plan,
0001 - 0999
General Key Plan
Architectural 1000 - 1999
ME - Mechanical
Civil Under FW & SW
and Electrical
Electrical 2000 - 2999
Mechanical 3000 - 3999
Process - Process Flow Diagrams 4000 - 4999
Process and Instrumentation Diagrams 5000 - 5999

Page 200 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix C continued...

Drawing Type Title Series Number

ME - Mechanical Hydraulic Profiles 6000 - 6999


and Electrical Structural Under ST
General Notes, Abbreviations & Legends, Location Plan,
0001 - 0999
General Key Plan, etc.

OG – Oil & Gas Layout & Key Plan 1000 - 1999


OIL & GAS .....
Standard & Miscellaneous Details 7000- 7999
.....
General Notes, Abbreviations & Legends, Location Plan,
0000 - 0999
General Key Plan, etc.
Proposed Potable Water Layout & Key Plan 1000 - 1999
PW -
Longitudinal Sections (Profiles) 2000 - 2999
Potable Water
.....
Standard & Miscellaneous Details 7000- 7999
.....
General Notes, Abbreviations & Legends, Location Plan,
0001 - 0999
General Key Plan, etc.

RR – Road Restraint Systems 1000 - 1999


Road Restraint .....
Standard & Miscellaneous Details 7000 - 5999
.....

General Notes, Abbreviations & Legends, Location Plan,


SC - 0001 - 0999
General Key Plan, etc.
Site Clearance
Site Clearance Layout & Key Plan 1000 - 1999

Site Boundaries 2000 - 2999

Page 201 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix C continued...

Drawing Type Title Series Number

…..
SC -
Standard & Miscellaneous Details 7000 - 7999
Site Clearance
.....
SH -
Shop Drawings 0001 - 9999
Shop Drawings

General Notes, Abbreviations & Legends, Location Plan,


0001 - 0999
General Key Plan, etc.

Street Lighting Layout & Key Plan 1000 - 1999

SL - Street Lighting Typical Cross Sections 2000 - 2999


Street Lighting Electrical Work For Road Lighting and Traffic Signs 3000 - 3999

.....

Standard & Miscellaneous Details 7000 - 7999


.....

General Notes, Abbreviations & Legends, Location Plan,


0001 - 0999
General Key Plan, etc.

ST - Structures 1000 - 1999

Structures ……

Standard & Miscellaneous Details 7000 - 7999


.....
General Notes, Abbreviations & Legends, Location Plan,
0001 - 0999
General Key Plan, etc.
Proposed Surface Water Layout & Key Plan 1000 - 1999
SW -
Longitudinal Sections (Profiles) 2000 - 2999
Surface Water
.....
Standard & Miscellaneous Details 7000 - 7999
.....

Page 202 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix C continued...

Drawing Type Title Series Number

General Notes, Abbreviations & Legends, Location Plan,


0001 - 0999
General Key Plan, etc.

Telecom Layout & Key Plan 1000 - 1999


TE -
QAF 2000 - 2999
Telecommunications
.....

Standard & Miscellaneous Details 7000 - 7999


.....
General Notes, Abbreviations & Legends, Location Plan,
0001 - 0999
General Key Plan, etc.
Traffic Flow 1000 - 1999
Bus Route 2000 - 2999

TR - Traffic Signal 3000 - 3999


Traffic/ Transport Traffic Management Plan 4000 - 4999

Traffic Diversion Plan 5000 - 5999


Traffic Maintenance 6000 - 6999

Standard & Miscellaneous Details 7000 - 7999


.....

General Notes, Abbreviations & Legends, Location Plan,


0001 - 0999
General Key Plan, etc.

TS - Proposed TSE Layout & Key Plan 1000 - 1999

Treated Sewage Longitudinal Sections (Profiles) 2000 - 2999


Effluent .....
Standard & Miscellaneous Details 7000- 7999
.....

Page 203 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix C continued...

Drawing Type Title Series Number

General Notes, Abbreviations & Legends, Location Plan,


0001 - 0999
General Key Plan, etc.

UC - Combined Utilities 1000 - 1999

Utility Services Utility Cross Sections 2000 - 2999


Corridor .....

Standard & Miscellaneous Details 7000 - 7999

.....
General Notes, Abbreviations & Legends, Location Plan,
BP - 0001 - 9999
General Key Plan, etc.
Building Permit
.....

XS - Cross Sections

(For those projects

that cannot fit within


Cross Sections 0001 - 9999
the discipline specific

cross section sheet

range)

Page 204 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix D – CAD COMPLIANCE CHECK LIST

Page 205 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

CAD Compliance Checklist


Project Number: Package: Date:

Stage:
Concept Preliminary Detailed Tender Contract As-Built
(Select One)

PWA CAD Standards Manual Version Used ____________________

Item Check List Description Checked


The file naming convention follows the requirements in the CAD Standards
1 Standard Naming Convention
Manual.
Layer Standards (Name, CAD layer names follow the requirements of the CAD Standards Manual. Current
2
Colour, Linetype) drawing layer is set to “0” and it should be empty.

Blocks are not exploded and follow the standard symbology.


3 Symbols and Blocks Standard
Blocks are inserted on appropriate layers.

4 Texts & Attributes All text size, font, style conforms to the CAD Standards Manual.

Line types follow the CAD Standards Manual. All linetype settings are set to
X- References

5 Linetypes
Bylayer. LTSCALE and PSLTSCALE are set to 1.

Dimensions are associative and placed on their proper layer. Dimension styles are in
6 Dimensions
accordance with the scale of the drawing and are not exploded.

Layouts, general arrangements and detailed plans are properly geo-referenced and
7 Global Origin and Orientation
drawn at the required coordinate grid system.

8 Bylayer Features are set to “Bylayer” (Object’s layer, colors, linetype, etc.)

Features on Appropriate There are no stray drawing elements or features that belong on other layers. There
9
Layers are no invalid feature types in feature layers.

10 Block Placement Blocks are placed on lines end points.

Drawings are purged to remove all unused layers, linetypes, blocks, text styles, etc.,
11 Purge / Audit
and all other extraneous and unnecessary information and entities.

I affirm that the CAD data prepared:

1. Complies with the requirements of the above mentioned CAD Database Standards Manual and

appropriate revision as applicable on this project/stage.

2. Has been checked and verified in accordance with the checklist attached.

Signed for & on behalf of: Insert company name here

Name:
Company
Stamp:
Position:

Signature:

Page 206 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Appendix E – SAMPLE SPREADSHEET FOR PROPOSING NEW


CAD LAYERS

Page 207 of 208


PWA CAD STANDARDS MANUAL V 5.0
September 2017

Table 1: A sample justification spreadsheet

For approval of newly proposed CAD layers, a spreadsheet (as shown below) should be

submitted to PWA accompanied with proper justification and a sample drawing


referencing the proposed layers, linetypes and objects.

Page 208 of 208

You might also like