XQ1475 Methane Detector Replacement

(Applicable to Frerk Build Units only)

Main Parts Required


456-5076 Control Gp – Electronic
456-5077 Sensor

Tool
458-8181 Calibration Tool

482-0203 complete parts required including accessories

-Include the followings wires

151-4908 Wire #18 10Ft


136-5321 3 Wire shielded 25Ft
CAUTION:
•Review on-site safety requirement with your supervisor before starting any work
•Use appropriate personnel protection requirement before starting the work.
•Use suitable lock-out/tag-out procedure before starting the work.
XQ1475 Methane Detector Replacement
(Layout)

Calibration tool
458-8181
Note: Tool is enough to test 20 units Picture shows a unit
with a UMR option.
XQ1475 Methane Detector Replacement
(Schematic)

388-8777 EC03 page 22


XQ1475 Methane Detector Replacement
(New Wiring Schematic)

151-4908 wire #18 ( 10FT approx)

TB2-8

TB2-9 & 10 TB2-1

ELECTRONIC
SENSOR
WHITE TB1-WHT

BLACK TB1-BLK 136-5321 cable 3 wire shielded (4 FT approx)

RED TB1-RED

136-5321 cable 3 wire shielded (21 FT approx)


SENSOR
XQ1475 Methane Detector Replacement
(Calibration Instruction)

See Attached Detector Manual


Section 3.19 Page 31

Testing
After calibration place the unit in Local Mode.
1.) Place the calibration tool on the sensor.
2.) Watch the % methane gas increase in value.
At 10% , DEIF Controller will display Gas Detected – Shutdown
3.) Remove calibration tool.
4.) Reset shutdown signal
5.) XQ1475 is now ready for service
Supplemental Information
Actual Methane Detector as installed

Methane detector’s electronics shown installed inside the ISO gear.


Supplemental Information
Actual Methane detector sensor as installation

Methane detector’s sensor shown installed above the ceiling.

Note: Sensor can also be mounted using existing bracket and hardware.