USB Protective Cover LCD Screen Key (Left) Key (Right) Battery Cover
USB Protective Cover LCD Screen Key (Left) Key (Right) Battery Cover
① pdf
Recording Options Multi-Use Certifications EN12830, CE, RoHS
Temperature Range -30°C to 70°C Validation Certificate Hardcopy ① ①
Open the data report in the newly created Temperature Accuracy ±0.5(-20°C/+40°C);±1.0(other range) PDF /ElitechLog Win or
removable disk of your computer and view the Software
Temperature Resolution 0.1°C Mac (latest version) ②
② data. You can also view the data by operating the
data management software. Data Storage Capacity 32,000 readings Report Generation Automatic PDF report ③ || ⑤
Connect the data logger
Note: Shelf Life/Battery 1 years1/CR2032 button cell Password Protection Optional on request ④
to a computer to set
|| Ⅰ Default setting:
configuration parameters Ⅰ Recording Interval 3 minutes(standard) Connection Interface USB 2.0, A-Type
Run time 30 days Start delay: 0 min
Log interval 2min Cyclic record: disabled
Startup Mode Button or software Alarm Configuration Optional, up to 5 points
Press and hold the left Trip ID 0000001 Temporary report: enable Stop Mode Button, software or stop when full With free Elitech Win or ① USB protective cover ④ Key (right)
Ⅱ
Reprogrammable
③ key for 5 seconds to Time zone UTC +0:00 Multi-start/stop: enabled MAC software
Protection Class IP67 ② LCD screen ⑤ Battery cover
Ⅲ
6 7 8