Abrams RugEye 47X Product Manual
LED Lightbar
Installation and
Operation Manual
Model# RE-47X
www.abramsmfg.com
844.9.ABRAMS
www.abramsmfg.com
info@abramsmfg.com
Table of Contents
Specifications .....................................................................................9
Troubleshooting.............................................................................. 10
Warranty .......................................................................................... 11
Warning
FAILURE TO INSTALL OR USE THIS PRODUCT ACCORDING TO MANUFACTURER’S RECOMMENDATIONS
MAY RESULT IN PROPERTY DAMAGE, SERIOUS INJURY, AND/OR DEATH.
Important
PLEASE READ ALL OF THE FOLLOWING INSPECT AND OPERATE THIS PRODUCT
INSTRUCTIONS BEFORE INSTALLING YOUR REGULARLY TO CONFIRM ITS PROPER
NEW ABRAMS PRODUCT. OPERATION AND MOUNTING CONDITION.
DO NOT USE A PRESSURE WASHER TO
PROPER INSTALLATION OF THIS PRODUCT CLEAN THIS PRODUCT.
REQUIRES THE INSTALLER TO HAVE A
GOOD UNDERSTANDING OF AUTOMOTIVE FOR THIS PRODUCT TO OPERATE
ELECTRONICS, SYSTEMS AND PROCEDURES. AT OPTIMUM EFFICIENCY, A GOOD
ELECTRICAL CONNECTION TO CHASSIS
THIS PRODUCT CONTAINS HIGH-INTENSITY GROUND MUST BE MADE. THE
LEDS. DO NOT STARE DIRECTLY INTO THESE RECOMMENDED PROCEDURE REQUIRES
LIGHTS. MOMENTARY BLINDNESS AND/OR THE PRODUCT GROUND WIRE TO BE
EYE DAMAGE COULD RESULT. CONNECTED DIRECTLY TO THE NEGATIVE (-)
BATTERY POST.
DO NOT INSTALL THIS PRODUCT OR ROUTE
ANY WIRES IN THE DEPLOYMENT AREA OF IT IS RECOMMENDED THAT THESE
YOUR AIR BAG. EQUIPMENT MOUNTED OR INSTRUCTIONS BE STORED IN A SAFE PLACE
LOCATED IN THE AIR BAG DEPLOYMENT AND REFERRED TO WHEN PERFORMING
AREA WILL DAMAGE OR REDUCE THE MAINTENANCE AND/OR REINSTALLATION
EFFECTIVENESS OF THE AIR BAG, OR OF THIS PRODUCT.
BECOME A PROJECTILE THAT COULD
CAUSE SERIOUS PERSONAL INJURY OR FAILURE TO FOLLOW THESE SAFETY
DEATH. REFER TO YOUR VEHICLE OWNER PRECAUTIONS AND INSTRUCTIONS COULD
MANUAL FOR THE AIR BAG DEPLOYMENT RESULT IN DAMAGE TO THE PRODUCT OR
AREA. THE USER/INSTALLER ASSUMES VEHICLE AND/OR SERIOUS INJURY TO YOU
FULL RESPONSIBILITY TO DETERMINE AND YOUR PASSENGERS!
PROPER MOUNTING LOCATION, BASED
ON PROVIDING ULTIMATE SAFETY TO ALL IF THIS PRODUCT USES A REMOTE DEVICE
PASSENGERS INSIDE THE VEHICLE. TO ACTIVATE OR CONTROL THIS PRODUCT,
MAKE SURE THAT THIS CONTROL IS
IF MOUNTING THIS PRODUCT REQUIRES LOCATED IN AN AREA THAT ALLOWS
DRILLING HOLES, THE INSTALLER MUST BE BOTH THE VEHICLE AND THE CONTROL
SURE THAT NO VEHICLE COMPONENTS OR TO BE OPERATED SAFELY IN ANY DRIVING
OTHER VITAL PARTS COULD BE DAMAGED CONDITION.
BY THE DRILLING PROCESS. CHECK BOTH
SIDES OF THE MOUNTING SURFACE BEFORE DO NOT ATTEMPT TO ACTIVATE OR
DRILLING BEGINS. ALSO DE-BURR ANY CONTROL THIS DEVICE IN A HAZARDOUS
HOLES AND REMOVE ANY METAL SHARDS DRIVING SITUATION.
OR REMNANTS. INSTALL GROMMETS INTO
ALL WIRE PASSAGE HOLES.
Package Contents:
RugEye-X Series Lightbar
Abrams Control Box
Universal Mounting Bracket Kit IMPORTANT! PLEASE READ THROUGH ALL
12 FT Power Cable Harness PROVIDED INSTRUCTIONS AND ANY LISTED
WARNINGS IN REGARDS TO PRODUCT USE.
Product Installation Manual
10~30V
Installing Brackets
Use supplied mounting brackets to attach light bar to the vehicles visor.
Mount the Blitz X-Series Inner Bar using the brackets supplied and user supplied mounting screws.
CAUTION: Be certain that you have selected a mounting location that does not obstruct
the driver’s vision and allows safe operation of the vehicle. Check the chosen mounting
location to ensure that the vehicle’s structure and material is adequate to support the
weight of your light.
FOOT PAD
VEHICLE ROOF
STRAP FOAM
Mounting
Place the full light bar on the top of your vehicle and adjust the feet to fit your vehicle according to the zones speci-
fied by the vehicle manufacture.
Light Bars should be mounted a minimum of 12” - 34” from the radio antenna to aviod interference.
If do not know where to mount your bar, seek a professional installer for the installation of your light bar.
attach the gutter mount bracket or vehicle specific bracket to the light bar using the bolt and tighten the bold until
your light bar is secure.
If are using the universal gutter bracket and it does not fit your vehicle, you may need to purchase a vehicle specific
bracket.
Once the light bar is secure, drill the bracket to the vehicle’s gutter for a more secure hold.
Wiring
Lower the headliner before drilling by 6” to 8” to protect it from damage caused by drilling the cable access hole.
The light bar’s wire harness will require you to drill a 3/8” hole for the cable access when the connector is not at-
tached
Warning! do not drill through the roof support member which spans between the passenger and drivers side of the
vehicle. Adjust the location where the bar will be mounted to avoid contact with this support member.
Remove all ridges or sharp edges of the hole with a round file. Make sure to de-burr the edges of the hole.
You must use a 3/8” Grommet (User Supplied) into the cable access hold.
Once the cables are fully pulled through, use professional grade silicone to weatherproof the hole.
Route the full length of the cable down towards your switch panel through the base of the B-Piller taking a 90 degree
turn to enter the B-Pillar.
** If you require additional information and / or video and user guides,
please visit www.abramsmfg.com/support or call Abrams Customer Support 844.9 Abrams
1 0 0 0 0 0 0 0 0 0 0 Warning Flash
Traffic --
0 0 1 0 0 0 0 0 0 0 0
Center
0 0 1 – 0 0 0 0 0 0 0 Traffic -- Left
0 0 1 0 – 0 0 0 0 0 0 Traffic -- Right
0/1 0/1 0/1 0/1 0/1 – 0/1 0/1 0/1 0/1 0/1 Dim -- 15%
Cruise Mode
N/A N/A N/A N/A N/A N/A – N/A N/A N/A N/A
-- 15%
0 0 0 0 0 0 0 – 0 0 0 Alley -- ON
0 0 0 0 0 0 0 0 – 0 0 Alley -- Flash
Take Down
0 0 0 0 0 0 0 0 0 – 0
-- ON
Take Down --
0 0 0 0 0 0 0 0 0 0 –
Flash
Specifications
Model Number Ameesa Light Bar
Input Voltage 10 ~ 15VDC
Peak Input Current 20 Amax @12V
Flash Patterns 8 Group + 31 Pattern
Fuse 20A
Storage Temperature Range -40°C~ +50°C
Trouble Shooting
All Manufacture Defects are covered under the Abrams Warranty
accordingly. Warranty is void with disassembly or rewiring of any Abrams
Products or Improper Wiring or Installation. If you are unsure how to trouble
shoot your light bar for any reason or if the trouble shooting does not fix your
issue, call Customer Service immediately for assistance at 844-9-ABRAMS
Warranty
This product has tested and found to be operational at the time
of manufacture. Provided this product is installed and operated in
accordance with the manufacturer’s recommendations. Abrams
Guarantees this product for a period of 5 years from the day of
purchase or delivery, whichever is later. Units demonstrated to be
defective within the warranty period will be replaced. Improper
installation or use of inappropriate or inadequate wiring or circuit
protection causes the warranty to be void. Failure or Destruction of
the product resulting from abuse or unusual use and/or accidents
is not covered by this warranty. Abrams shall in no way be liable for
other damages including consequntial, indirect or or special damages
whether loss is due to negligence or breach of warranty. Abrams
makes no other express or implied warranty including, without
limitation, warranties of fitness or merchantability, with respect to
this product.