Download as pdf or txt
Download as pdf or txt
You are on page 1of 84

Issue No.

: FSN140019
MARINE Issue Date : DEC. 25, 2014

Person in-charge :
K. Shiraiwa, Manager & Group Leader
Navigation & Fishing Electronics Group
Engineering Department
Marine Electronics Division

Service News
Information X Request for work

1 Subject : Request for modifying JMR-9200/7200series RADAR, JAN-9201/7201 ECDIS, and JAN-
9202/7202 CONNING
2 Product name : RADAR, ECDIS, and CONNING
3 Model number : JMR-9200/7200series RADAR, JAN-9201/7201 ECDIS, and JAN-9202/7202 CONNING
4 Details
4.1 General
The upgrade of JMR-9200/7200 series RADAR, JAN-9201/7201 ECDIS, and JAN-9202/7202 CONNING is needed to
the latest hardware and software.
4.2 Information
Since equipment specifications differ for every ship, please carried out the following work based on a direction from
Marine Service Dept:
a. The check of the terminal modification mistake in SLC
b. The wiring check of the cable between ISW-RIF
c NDC-1590
c. NDC 1590 CCU hardware modification
d. NCE-5605 TOPU hardware modification
e. NBD-913 PSU hardware modification
f. CCK-1061 Keyboard module hardware modification
g. NDC-1590 Firmware update   V01.05
h. NCE-5605 Firmware update   V01.04
i. SLC MAC Address update
j. SLC software update   V01.00.089
k. MFD application software update   V01.00.523
l. PM label attachment
m. RPS image renewal
n. Initialization of RADAR signal processing setting and TT setting

Note: Download the software for the above items g, h, i, j, k, and n from the homepage of Marine Service Dept. When
the equipment does not installed the latest software version, please update to the latest version.
5 Attached documents  a and b. Correct Terminal information of JB.pdf [7ZPNA4510]
 c. Replacing the CCU.pdf [7ZPNA4511]
 d. Replacing the TOPU.pdf [7ZPNA4512]
 e. Replacing the PSU.pdf [7ZPNA4513]
 f. Replacing the Keyboard Module.pdf [7ZPNA4514]
 g. Updating software of the CCU Firmware.pdf [7ZPNA4515]
 h. Updating software of the TOPU Firmware.pdf [7ZPNA4516]
 i. SLC_MacSettingManual.pdf [7ZPNA4517]
 j. Updating software of the SLC.pdf [7ZPNA4518]
 k. Updating software of the MFD Application.pdf [7ZPNA4519]
 l. PMLABEL.pdf [7ZPNA4520]
 m. JAN-5203_RPS_Software_Updating_Procedure.pdf [7ZPNA4521]
n. Initializing signal process and TT setting.pdf [7ZPNA4522]
6 Related Service-news and/or Technical Information : None
7 Issue schedule for Technical Information : None
DC24V *1)D2
J8100
1 24V+
J8104
LAN1
J8111
*1)LAN
To JRC LAN Main HUB
7ZPNA4510
9.6W
2 24V GND 1 RX3A LAN2 To JRC LAN Sub HUB
J8102 2 RX3B J8108 *1)LAN
3 TX3A
OUT1 1
1 4 TX3B
RET1 2
2 5 RX4A
OUT2 3
3 6 RX4B
RET2 4
4 RX9A 7 TX4A
OUT3 5
5 RX9B 8 TX4B
RET3 6
6 RX9C
J8103 OUT4 7
J8101 RET4 8
1 RX5A
OUT5
1 2 RX5B
RET5
Wrong Terminal number & Name 2 3 TX5A
OUT6
3 4 TX5B
RET6
4 A 5 RX6A
OUT7
5 B 6 RX6B
RET7
6 C 7 TX6A
OUT8
J8105 8 TX6B
RET8
J8106
1 RX1A J8107
2 RX1B 1 RX7A
IN1 1
3 TX1A 2 RX7B
GND 2
4 TX1B 3 TX7A
IN2 3
5 RX2A 4 TX7B
GND 4
6 RX2B 5 RX8A
IN3 5
7 TX2A 6 RX8B
GND 6
8 TX2B 7 TX8A
IN4 7
8 TX8B
GND 8

Correct Terminal number & Name

CMH-2370
Serial LAN Interface Circuit
TB801 J8115 (No.x xxx SLC)
Wrong information is describe in 1st edition installation
drawing & installation manual. TB841 J842
SCANNER J832
Confirm correct Terminal number & Name 1
CQD-2273
1)*RG-10UY(MAX*2)H-2695110056
400m)
AN1+ RADAR Interface Circuit VD_IN+ 1
1 To No.1 RADAR
2 AN1- (No.1 RIF) VD_IN- 2
JRC No.1 RADARJRC No.1 RADAR Supply
Supply Scanner Unit
3 AN2+ TRG_IN+ 3
2
4 AN2- TRG_IN- 4
5 AN3+ BP_IN+ 5
3
6 AN3- BP_IN- 6
7 AN4+ BZ_IN+ 7
4
8 AN4- BZ_IN- 8 ORN
MTR+
CMJ-560 MTR-
WHT

Analog Option
Circuit (AOC) MTRG
J835 N.C.
DC_OUT+ RED
GIF_RIF BLU
DC_OUT-
CMJ-554 J821
Gyro Interface SLC_GIF TB838
Circuit
(GIF) J822 1 YEL
GRN Cable color of RIF ISW cable
RIF_GIF 2
J823 J834
J837 ISW_IN To NQE-3141-4A
2 *2)2695111153(10m)
1 1_R1 AC_SC_IN VD+ 1
2 2_S2 VD- 2 Inter Switch Unit
RED
3 3_S2 J839 TRG+ 3
4 S3 DC_SC_IN TRG- 4 PUR
5 5_R2 BP+ 5 There is no information of cable color
6 N.C. J831 BP- 6 CLR
7 P+ RIF BZ+ 7
8 P- BZ- 8 WHT-
MTR+ YEL

MTR- WHT-
*2) CML-836-ACF:W852 (5m) MTRG WHT
To No.1RADAR POWER_OUT
ORN
Power Supply Unit(PSU) POWER_OUTE
BLK
NBD-913 PWR_IN
PINK

PWR_INE
BRN Wrong information is describe in
To No.1RADAR *2) CML-836-ACF:W842 (5m) 1st edition installation drawing &
Central Control Unit(CCU) EX_OUT J836
ISW_OUT J833 installation manual.
NDC-1590 1 VD+
VD+ 1
1
2 VD-
3 TRG+
VD- 2 BLU Confirm cable color and ISW
TRG+ 3 cable connection.
4 TRG-
TRG- 4
5 BP+ YEL
BP+ 5
6 BP-
BP- 6
7 BZ+ GRN
BZ+ 7
8 BZ-
BZ- 8
GND WHT-
MTR+ BLU
N.C.
MTR-
NQE-1143 MTRG
WHT-
WHT

No.1 Junction Box (No.1 JB) FG

7. Interconnection Diagram of GRD-921 Bridge Interface(1/12)


NQE-3141-4A
Inter Switch Unit
To CQD-2273 No.1 RIF *2)2695111153(10m) TB911 TB915
1
1 VDIN 1 VDIN
RADAR Interface Circuit 2 VDINE 2 VDINE
BLU 3 TRIGIN 3 TRIGIN
4 TRIGINE 4 TRIGINE
YEL 5 BPIN 5 BPIN
6 BPINE 6 BPINE
GRN 7 BZIN 7 BZIN
8 BZINE 8 BZINE
WHT-BLU 9 MTRIN+ 9 MTRIN+
WHT-WHT 10 MTRIN- 10 MTRIN-
11 MTRINE 11 MTRINE
ORG 12 PWRIN 12 PWRIN
BLK 13 PWRINE 13 PWRINE
PNK 14 PWROUT 14 PWROUT
BRN 15 PWROUTE 15 PWROUTE
TB912 TB916
2
1 VDOUT 1 VDOUT
2 VDOUTE 2 VDOUTE
RED 3 TRIGOUT 3 TRIGOUT
4 TRIGOUTE 4 TRIGOUTE
PUR 5 BPOUT 5 BPOUT
6 BPOUTE 6 BPOUTE
CLR 7 BZOUT 7 BZOUT
8 BZOUTE 8 BZOUTE
WHT-YEL 9 MTROUT+ 9 MTROUT+
WHT-WHT 10 MTROUT- 10 MTROUT-
11 MTROUTE 11 MTROUTE

TB913 TB917
1 VDIN 1 VDIN
2 VDINE 2 VDINE
3 TRIGIN 3 TRIGIN
4 TRIGINE 4 TRIGINE
5 BPIN 5 BPIN
6 BPINE 6 BPINE
7 BZIN 7 BZIN
8 BZINE 8 BZINE
9 MTRIN+ 9 MTRIN+
10 MTRIN- 10 MTRIN-
11 MTRINE 11 MTRINE
12 PWRIN 12 PWRIN
13 PWRINE 13 PWRINE
14 PWROUT 14 PWROUT
15 PWROUTE 15 PWROUTE
TB914 TB918
1 VDOUT 1 VDOUT
2 VDOUTE 2 VDOUTE
3 TRIGOUT 3 TRIGOUT
4 TRIGOUTE 4 TRIGOUTE
5 BPOUT 5 BPOUT
6 BPOUTE 6 BPOUTE
7 BZOUT 7 BZOUT
8 BZOUTE 8 BZOUTE
9 MTROUT+ 9 MTROUT+
10 MTROUT- 10 MTROUT-
11 MTROUTE 11 MTROUTE

TB901
U
*1)D2 FG
SHIP’S MAIN V

D1 : 0.6/1 kV DPYC-1.5
D2 : 0.6/1 kV DPYC-2.5
D6 : 0.6/1 kV DPYC-6
TTYCSLA-1 :150/250 V TTYCSLA-1
TTYCSLA-1T :150/250 V TTYCSLA-1T
TTYCSLA-4 :150/250 V TTYCSLA-4
TTYCSLA-10 :150/250 V TTYCSLA-10
MPYC-2 :150/250 V MPYC-2
MPYC-4 :150/250 V MPYC-4 *1): Shipyard Supply
LAN :CAT-5e LAN Cable *2): JRC Supply

7. Interconnection Diagram of GRD-921 Bridge Interface(11/12)


7ZPNA4511

Replacing the CCU: NDC-1590

Discriminate replaced unit from delivered unit


Confirm CCU serial No..

Be sure to check the name plate and model before replacing the CCU. Check that the

nameplate of the pre-upgrading is the same as that of the replacement CCU.

Name Plate

[Required Tools]
The tools shown in the following table are required for replacement work.
Table Required Tools

No Name Size External Appearance

1 Flat head screwdriver 6 mm

2 Phillips screwdriver Size #2

Before conducting replacement work, turn OFF the circuit breaker for the power supply of the display

unit.

Do not lose the screws as they will be needed again.


7ZPNA4511

1 Remove the front cover of the display unit mount kit. (Flash Mount:Skip this
procedure)
Remove the screws that fasten the front cover of the display unit mount kit with a flat head screwdriver
and then take out the front cover.

2 Remove the Delivered CCU from the display unit mount kit. (Flash Mount:Skip this
procedure)
Remove all the cables being connected to the front of the CCU. Remove the screws (M5: 2 locations) of
the mounting plate that fasten the CCU, pull out the CCU together with the mounting plate, and then
remove it from the display unit mount kit.
7ZPNA4511

3 Remove Delivered CCU


Remove the screws (M4: 4 locations) of the mounting plate and pull out the CCU from the mounting plate.
After that, replace the CCU.

4 Replace the CCU


Reinstall the CCU into the display unit mount kit by repeating the same procedure in the reverse order.

Be careful not to forget to insert the cable connectors.

Cable Number(Display Mount/Flash Mount) Connector


W71/W72 J4101 DVI-MNU
W61/W62 J4201 USB-OPU
W51/W52 J4204 PSU-CONT
W53/W54 J4301 PWR-PSU

The following cables may be connected depending on the specification of a ship.


Cable Number(Display Mount/Flash Mount) Connector
W75/W76 J4118 USB_TP
W63 J4202 SER-OPU
Ethernet Cable J4117 LAN1
Ethernet Cable J4122 LAN2
W841/W842 J4203 RIF
7ZPNA4512

Replacing the TOPU: NCE-5605

Discriminate replaced unit from delivered unit


Confirm TOPU serial No..

[Required Tools]
The tools shown in the following table are required for replacement work.
Table Required Tools

No Name Size External Appearance

1 Flat head screwdriver 6 mm

2 Phillips screwdriver Size #2

3 Diagonal pliers -

4 Cable-tie -

Before conducting replacement work, turn OFF the circuit breaker for the power supply of the display

unit.

Do not lose the screws as they will be needed again.

To prevent damage to the Unit during the replacement work, cut every cable-ties off before work.
7ZPNA4512

1 Remove the front cover of the display unit mount kit. (Flash Mount:Skip this
procedure)
Remove the screws that fasten the front cover of the display unit mount kit with a flat head screwdriver
and then take out the front cover.

2 Cut off every cable-tie that fastens the TOPU cable.


(Example for Stand-alone type is shown below.)
Cut off every cable-tie that fastens the TOPU cable (W61).

Before conducting Unit replacement work, always be sure that every


cable-tie that fastens the cable has been cut off.

Replacement work without above may lead Unit/cable breakage.


7ZPNA4512

3 Remove the screws of the TOPU.


Remove the two screw covers at the bottom right and left of the trackball. The screw covers can come off
by pushing them down inward. Remove the screws (M4: 2 locations) inside the screw covers that fasten
the TOPU.
7ZPNA4512

4 Change the TOPU.


Flip over the TOPU and remove the rear cable (W6: J601). J601 can be released by pulling it out while
holding down the center tab. If a keyboard operation unit (KOPU) is mounted, also remove the KOPU
cable (W64: J614). J614 can be released by pushing the both ends of the connector. Remove the TOPU
from the mounting frame and change it.
After replacing the TOPU, assemble to the original condition by repeating the same procedure in the
reverse order. Apply new cable-ties to the cables from where cable-ties were cut off. Please make sure to
tighten all the screws and connect all the cables back in place.

If you try to pull out the cable before pressing the center tab, the connector may become difficult
to be released.
In that case, push the connector itself to insertion direction once, and then pull it out while
holding down the center tab.
It will be difficult to pull out W6 without pushing tab enough, then
please reinsert W6 and try again.
7ZPNA4513

Replacing the PSU: NBD-913

Discriminate replaced unit from delivered unit


Confirm Blue mark labeled on NBD-913 unit and packing box.

AC and DC power supplies are connected to the PSU. Before replacement work,
be sure to turn OFF the applicable power circuit breaker. Not following this
instruction will cause electric shock and/or malfunction.

[Required Tools]
The tools shown in the following table are required for replacement work.
Table Required Tools
No. Name Size External Appearance
1 Flat head screwdriver 6 mm

2 Phillips screwdriver Size #2

Before conducting replacement work, turn OFF the circuit breaker for the power supply of the display

unit.

Do not lose the screws as they will be needed again.


7ZPNA4513

1 Remove the front cover of the display unit mount kit. (Flash Mount:Skip this
procedure)
Remove the screws that fasten the front cover of the display unit mount kit with a flat head screwdriver
and then take out the front cover.

2 Remove the Delivered PSU from the display unit mount kit. (Flash Mount:Skip this
procedure)
Remove all the connectors being connected to the front of the PSU. Loosen the two screws of the TB1
on the right and left of the front and remove it together with the wires. The J50 and the J51 can be
removed by pulling them out while holding down the tabs at the top center.
Remove the screws (M5: 2 locations) of the mounting plate that fasten the PSU, pull out the CCU
together with the mounting plate, and then remove it from the display unit mount kit.

To secure safety, turn OFF the main power circuit breakers of AC and DC power supplies before

replacement work.
7ZPNA4513

3 Remove Delivered PSU


Remove the screws (M4: 4 locations) of the mounting plate and pull out the PSU from the mounting plate.
After that, replace the PSU.

4 Replace the PSU


Reinstall the PSU into the display unit mount kit by repeating the same procedure in the reverse order.

Be careful not to forget to insert the cable connectors.

Cable Number(Display Mount/Flash Mount) Connector


W53/W54 J52 OUT
W51/W52 J53 CONT

The following cables may be connected depending on the specification of a ship.


Cable Number(Display Mount/Flash Mount) Connector
W851/W852 J50 AC OUT
W853/W854 J51 DC OUT
7ZPNA4514

Replacing the Keyboard Module: CCK-1061

Discriminate replaced unit from delivered unit


Confirm Keyboard Module Serial No.
Example S/N: Y1409880632016
Y14*********** is replaced unit serial No.

AC and DC power supplies are connected to the PSU. Before replacement work,
be sure to turn OFF the applicable power circuit breaker. Not following this
instruction will cause electric shock and/or malfunction.

[Required Tools]
The tools shown in the following table are required for replacement work.
Table Required Tools
No. Name Size Appearance
1 Phillips screwdriver Size #2

Before conducting replacement work, turn OFF the circuit breaker for the power supply of the display

unit.

Do not lose the screws as they will be needed again.


7ZPNA4514

1 Remove the screws of the KOPU.


Remove the four screw covers at the top and bottom of the KOPU. The screw covers can come off by
pushing them down inward. Remove the screws (M4: 4 locations) inside the screw covers that fasten the
TOPU.

2 Change the keyboard: CCK-1061.


Disconnect the FPC that connects between the operation circuit B and the keyboard: CCK-1061. FPC
can be released by sliding the actuator of J641 horizontally.
Remove the screws (M3: 13 locations) that fasten the CCK-1061 and change it.
After replacing the CCK-1061, assemble to the original condition by repeating the same procedure in
the reverse order. Please make sure to tighten all the screws and connect all the cables back in place.

When mounting the new keyboard, be careful so that the waterproof packing dos not get into the inside

of the keyboard.

Exercise caution when handling the FPC as it is very fragile.

When installing the FPC, be careful not to insert them slanted or bend them.
7ZPNA4514
7ZPNA4515

Updating software of the CCU Firmware


Note
When software update starts, the tasks that are active are automatically terminated.
Complete the necessary operation such as saving of settings prior to the start of update.

1 Required Item
The following item is required to update the CCU Firmware.
Table Required Item
No. Name Model Name
1 CD/DVD or USB memory containing CCU -
Firmware update Tool and data

When you want to use a USB flash memory to read or write a file, make sure in
advance that the USB flash memory is not affected by a computer virus. If the
display unit is infected with a virus, other equipment will also be infected, with
the result that a trouble will occur.

Before removing the USB flash memory, check for the access lamp of the USB
flash memory and make sure that it is not being accessed.
If you remove the USB flash memory when it is accessed, data may be
destroyed and a trouble may occur.
7ZPNA4515

2 Applying the power and activating the maintenance tool


(1) Apply power to the indicator by using the PWR switch of the trackball operation unit. The
Task selection screen is displayed.

(2) Position the cursor on the Password window and left-click on it. The Password input
screen is displayed. Enter “1074”.
7ZPNA4515

3 Updating the CCU Firmware by using the remote update tool


(1) The maintenance tool is activated. Connect the USB memory containing the CCU
Firmware remote update tool to the USB port of the trackball operation unit.

(2) Select CompanionUpdate.exe and press OK. The remote update tool is activated.

(3) Check the COM port in the Step1 Setup Interface item.
Check that COM4:blzam Virtual Com Port is selected. Do not select any other COM port.
After checking, press the Open button.
7ZPNA4515

(4) Press the “Get Version” button in the Step2 Select Software item. Subsequently, select
COMPANION-APL (Ver.01.**) from the tab. (**: Software version)

(5) Press the “Browse…” button in the Step3 Select update file item. When the Explorer
screen is displayed, select the latest CMP software file (CMP_APL_***.img).

When the Software type and the update file do not match, an error occurs.
7ZPNA4515

(6) After the file is selected, the “Update” button is enabled in the Step4 Update item. Start
Update by pressing the button.

(7) When Update is finished normally, the Update completion window is displayed. When the
OK button is pressed, the remote update tool is terminated and processing returns to the
Task screen. When the restart confirmation screen is displayed, restart.

4 Confirming the updating version


After updating, confirm the firmware version in maintenance menu.
1 Click on the [Menu] button on the left toolbar.
The menu is displayed.

2 Click on the [Maintenance] - [System Information] button on the menu.


The [System Information] dialog box appears.
Click on the [Software] tab.
7ZPNA4515

3 The software information is displayed.

(1)

(2)

(3)

(1) [X] button


Click on this button to close the "System Information" dialog box.
(2) Software information

Item Displayed information


Jxx-xxxx Type and model name of the system
Application Version of the application software
Maintenance No. 8-digit maintenance number
TXRX Version of the software used for the radar transmitter-receiver
unit
* This information is displayed when the system is equipped
with the RADAR function.
TCS Version of the software used for TCS
* This information is displayed when the system is equipped
with the TCS function.
Presentation Library Edition of S52 Presentation Library
Displayed for ECDIS or RADAR (ENC chart display license
available) only
7ZPNA4515

(2)-1 Click on this list and code input dialog is displayed.


(2)-2 Input “0000” and additional software information is displayed.

(3) Confirm updating software version.


Carrire Board: V01.03 or later
7ZPNA4516

Updating software of the TOPU Firmware


Note
When software update starts, the tasks that are active are automatically terminated.
Complete the necessary operation such as saving of settings prior to the start of update.

1 Required Item
The following item is required to update the TOPU Firmware.
Table Required Item
No. Name Model Name
1 CD/DVD or USB memory containing TOPU -
Firmware update Tool and data

When you want to use a USB flash memory to read or write a file, make sure in
advance that the USB flash memory is not affected by a computer virus. If the
display unit is infected with a virus, other equipment will also be infected, with
the result that a trouble will occur.

Before removing the USB flash memory, check for the access lamp of the USB
flash memory and make sure that it is not being accessed.
If you remove the USB flash memory when it is accessed, data may be
destroyed and a trouble may occur.
7ZPNA4516

2 Supplying the power and activating the maintenance tool


(1) Supply the power to the indicator by using the PWR switch of the trackball operation unit.
The Task selection screen is displayed.

(2) Position the cursor on the Password window and left-click on it. The password input
screen is displayed. Enter “1074”.
7ZPNA4516

3 TOPU Firmware updating by using the remote update tool


(1) The maintenance tool is activated. Connect the USB memory containing the TOPU
Firmware remote update tool to the USB port.

Caution!!
Do not use the USB port of TOPU. Otherwise, the TOPU operation unit is reset during
updating, making update impossible. Use USB Port of CCU

(2) Select OperationUpdate.exe and press OK. The remote update tool is activated.
7ZPNA4516

(3) Check the COM port in the Step1 Setup Interface item.
Check that COM6:NCE-5605 Virtual COM Port is selected. Do not select any other COM
port. After checking, press the Open button.

(4) Press the “Get Version” button in the Step2 Select Software item. Subsequently, select
OPERATION-APL (Ver.V01.**) from the tab. (**: Software version)
7ZPNA4516

(5) Press the “Browse…” button in the Step3 Select update file item. When the Explorer
screen is displayed, select the latest TOPU CMP software file (OPU_APL_***.img).

When the Software type and the update file do not match, an error occurs.

(6) After the file is selected, the “Update” button is enabled in the Step4 Update item. Start
Update by pressing the button.
7ZPNA4516

(7) When Update is finished normally, the Update completion window is displayed. When the
OK button is pressed, the remote update tool is updated and processing returns to the Task
screen. When the restart confirmation screen is displayed, restart.

4 Confirming the updating version


After updating, confirm the firmware version in maintenance menu.
1 Click on the [Menu] button on the left toolbar.
The menu is displayed.

2 Click on the [Maintenance] - [System Information] button on the menu.


The [System Information] dialog box appears.
Click on the [Software] tab.

3 The software information is displayed.

(1)

(2)

(3)

(1) [X] button


Click on this button to close the "System Information" dialog box.
7ZPNA4516

(2) Software information

Item Displayed information


Jxx-xxxx Type and model name of the system
Application Version of the application software
Maintenance No. 8-digit maintenance number
TXRX Version of the software used for the radar transmitter-receiver
unit
* This information is displayed when the system is equipped
with the RADAR function.
TCS Version of the software used for TCS
* This information is displayed when the system is equipped
with the TCS function.
Presentation Library Edition of S52 Presentation Library
Displayed for ECDIS or RADAR (ENC chart display license
available) only

(2)-1 Click on this list and code input dialog is displayed.


(2)-2 Input “0000” and additional software information is displayed.

(3) Confirm updating software version.


USB Operation Unit: V01.03 or later
7ZPNA4517

October 31, 2014


Japan Radio Co., Ltd.
SLC MAC address setting manual
1 Preparation
(1) Copy all the “SlcAlcSetupMacro” folder of MAC setting tool to the root folder of the USB memory.
(2) Connect USB memory to the USB connector on the operation unit.
(3) Check the IP address of MFD has been set from installation menu.

(4) Check the value of SLC rotary switch ( 0 – F ) for setting MAC address.
(5) Turn off the power of all SLC, and turn on the power of only SLC to set MAC address.

Figure 1. SLC board

Power switch

Rotary switch

1/8
7ZPNA4517

2 Setting of MAC address


(1) Enter 1074 in the password column of the task menu, and press [Enter] button.

(2) Select “ttpmacro.exe” in the USB memory, and press [OK] button.
Folder:SlcAlcSetupMacro

2/8
7ZPNA4517

(3) Selection screen of the macro file is displayed.

(4) Select “SetupMACAddress.ttl” in the USB memory, and press [OK] button.
Folder:SlcAlcSetupMacro/macro

3/8
7ZPNA4517

(5) Connect to SLC after starting the macro.

Select “Main LAN”, and press [OK] button.

Select SLC number from the value of SLC rotary switch, and press the [OK] button.
(For details of SLC number, refer to Table 1)

Table1. SLC number


Value of
SLC number
Rotary switch
0 Main SLC1 : 172.16.60.107
1 Main SLC2 : 172.16.60.108
2 Main SLC3 : 172.16.60.109
3 Main SLC4 : 172.16.60.110
4 Main SLC5 : 172.16.60.111
5 Main SLC6 : 172.16.60.112
6 Main SLC7 : 172.16.60.113
7 Main SLC8 : 172.16.60.114

4/8
7ZPNA4517

8 Main SLC9 : 172.16.60.115


9 Main SLC10 : 172.16.60.116
A Main SLC11 : 172.16.60.117
B Main SLC12 : 172.16.60.118
C Main ALC1 : 172.16.60.119
D Main ALC2 : 172.16.60.120
E Main ALC3 : 172.16.60.121
F Main ALC4 : 172.16.60.122

While connecting to the selected SLC, the following screen is displayed.


(Maximum connection time is about 30 seconds)

If the connection is successful, the following menu screen is displayed.

Table.2 Detail of menu item


Menu item Description
MAC Address Verification MAC address and bar code number of SLC can be checked.
MAC Address Automatic MAC address is automatically set from the bar code number
Setting of SLC.

MAC Address Manually


MAC address can be set manually. (Unused)
Setting
SLC/ALC Restart Restart of SLC/ALC. (Unused)
SLC/ALC Change Exchange of SLC/ALC.

5/8
7ZPNA4517

(6) Check the MAC address before setting.

Select the “MAC Address Verification” of the menu, and press [OK] button.

During communication, the following screen is displayed.


(Maximum communication time is about 30 seconds)

If reading of the bar code number and the MAC address is successful, the following screen is
displayed.

Confirm that the MAC address is in the below value, and go back to the menu by pressing [OK]
button.
When MAC address is different from the below value, setting of MAC address is not required.

MAC Address CH0 : 00-00-27-02-00-00


MAC Address CH1 : 00-00-27-02-01-00

6/8
7ZPNA4517

(7) Automatic setting of MAC address

Select the “MAC Address Automatic Setting” of the menu, and press [OK] button.

During setting, the following screen is displayed.


(Maximum setting time is about 60 seconds)

When the automatic setting of the MAC address is successful, the following screen is
displayed.

Confirm that the MAC address is in the below value, and go back to the menu by pressing [OK]
button.

MAC Address CH0 : 00-00-27-02-XX-XX (XX-XX is other than 00-00 value)


MAC Address CH1 : 00-00-27-02-XX-XX (XX-XX is other than 01-00 value)

7/8
7ZPNA4517

(8) Exchange of SLC for setting MAC address.

Turn off the power of all SLC, and turn on the power of only SLC to set MAC address.
Select the “SLC/ALC Change” of the menu, and press [OK] button.

After this, do same operation as described (5).


If you want to exit the macro, press the [Cancel] button.

8/8
7ZPNA4518

Updating software of the SLC: CMH-2370


Update the software of SLC/ALC that is installed in this ship to the latest version. Check the
following items before updating the version.

1 Required Item
The tools shown in the following table are required for replacement work.
Table Required Tools

No Name Size External Appearance

1 Flat head 6 mm
screwdriver

2 Phillips screwdriver Size #2

Do not lose the screws as they will be used again.

Note
When software update starts, the tasks that are active are automatically terminated.
Complete the necessary operation such as saving of settings prior to the start of update.

The following item is required to update the SLC software.


Table Required Item
No. Name Model Name
1 CD/DVD or USB memory containing SLC -
software update Tool and data

When you want to use a USB flash memory to read or write a file, make sure in
advance that the USB flash memory is not affected by a computer virus. If the
display unit is infected with a virus, other equipment will also be infected, with
the result that a trouble will occur.

Before removing the USB flash memory, check for the access lamp of the USB
flash memory and make sure that it is not being accessed.
If you remove the USB flash memory when it is accessed, data may be
destroyed and a trouble may occur.
7ZPNA4518

2 Prior confirmation
Confirm the following contents before the update.
(1) Number of SLCs/ALCs that are installed on this ship
Check the JB on this ship and check the number of SLCs/ALCs that are installed on this
ship.
Software updating must be carried out for all the SLCs/ALCs.
Open the cover (fixed by four screws) of each JB and check that SLC or ALC is installed.
7ZPNA4518

(2) Confirming the setting of SLC/ALC S3 rotary switch


Check the setting of S3 rotary switch of SLC/ALC. If there is an SLC with the same switch
setting in each of the MAIN network and SUB network, the software cannot be updated
correctly.
SLC/ALC S3 rotary switch

MAIN/SUB network identification seal LAN connector


SLC No. identification seal J8111: For Main
SLC/ALC identification seal J8112: For Sub

Main/Sub network setting

(3) Confirming network connection


By using the network connection from the indicator, update the SLC software.
Check the network connection in advance.
Check that the indicator, NQA-2443 Sensor LAN Unit (referred to as the Sensor LAN Unit
henceforth), and SLC/ALC are all turned on.
MAIN SLC: Check that CCU LAN1 –Sensor LAN unit for Main – SLC J8111 are connected
through the Ethernet Cable.
SUB SLC: Check that CCU LAN2 – Sensor LAN unit for Sub – SLC J8112 are connected
through the Ethernet cable.
7ZPNA4518

3 Supplying the power and activating the maintenance tool


Check that the indicator body, Sensor LAN Unit, and SLC are all turned on. For the indicator,
check also that the breaker of NBD-913D is turned ON.
Update can be performed from any indicator as long as it is connected to SLC through the
network.

(1) Turn on the power of the indicator by using the PWR switch of the trackball operation unit.
The Task selection screen is displayed.

Caution!!
When update SLC software, do not use task function, other task station need to set Task
select Screen.
7ZPNA4518

(2) Position the cursor on the Password window and left-click on it. The Password input
screen is displayed. Enter “1074”.

4 Updating SLC/ALC software by using the remote update tool


(1) The maintenance tool is activated. Connect the USB memory containing the SLC/ALC
remote update tool to the USB port of the trackball operation unit.

(2) Select SlcAlcUpdate.exe and press OK. The remote update tool is activated.

(3) Select a network in the Step1 Setup Interface item.


SLC that is connected to MAIN LAN: IEC61162-450 Network-MAIN:172.16.60.*
SLC that is connected to SUB LAN: IEC61162-450 Network-SUB:172.17.60.*
7ZPNA4518

(4) In Equipment of Step2 Select equipment, select the SLC for which software update is to
be performed. The IP address of the selected SLC is automatically input in Equipment IP. Do
not change the port.

Use the No.* seal of SLC as the numeric digits of SLC*. For instance, No.2 SLC=SCL2.

The following table shows the list of IP addresses of SLC/ALC for confirmation.
7ZPNA4518

S3 Operation
No. Main LAN Sub LAN
Position mode
0 SLC1 172.16.60.107 172.17.60.107
1 SLC2 172.16.60.108 172.17.60.108
2 SLC3 172.16.60.109 172.17.60.109
3 SLC4 172.16.60.110 172.17.60.110
4 SLC5 172.16.60.111 172.17.60.111
5 SLC6 172.16.60.112 172.17.60.112
SLC
6 SLC7 172.16.60.113 172.17.60.113
7 SLC8 172.16.60.114 172.17.60.114
8 SLC9 172.16.60.115 172.17.60.115
9 SLC10 172.16.60.116 172.17.60.116
A SLC11 172.16.60.117 172.17.60.117
B SLC12 172.16.60.119 172.17.60.118
C ALC1 172.16.60.118 172.17.60.119
D ALC2 172.16.60.120 172.17.60.120
ALC
E ALC3 172.16.60.121 172.17.60.121
F ALC4 172.16.60.122 172.17.60.122

(5) Press the “Get Version” button on the Step3 Select Software item. Subsequently, select
SLC/ALC-APL (Ver.01.00.**) from the tab. (**: Software version)
7ZPNA4518

(6) Press the “Browse…” button in the Step4 Select update file item. When the Explorer
screen is activated, select the latest SLC/ALC software file (SLC _APL_***.img).

When the software type and update file do not match, an error occurs.

(7) After the file is selected, the “Update” button is enabled in the Step5 Update item. Start
Update by pressing the button.
7ZPNA4518

(8) When Update is finished normally, the Update completion window is displayed. When the
OK button is pressed, the remote update tool is terminated and processing returns to the
Task screen. When the activation confirmation screen is displayed, restart.

5 Confirming the update version


After updating, confirm the SLC software version in maintenance menu.
1 Click on the [Menu] button on the left toolbar.
The menu is displayed.

2 Click on the [Maintenance] - [System Information] button on the menu.


The [System Information] dialog box appears.
Click on the [Software] tab.

3 The software information is displayed.

(1)

(2)

(3)

(1) [X] button


Click on this button to close the "System Information" dialog box.
7ZPNA4518

(2) Software information

Item Displayed information


Jxx-xxxx Type and model name of the system
Application Version of the application software
Maintenance No. 8-digit maintenance number
TXRX Version of the software used for the radar transmitter-receiver
unit
* This information is displayed when the system is equipped
with the RADAR function.
TCS Version of the software used for TCS
* This information is displayed when the system is equipped
with the TCS function.
Presentation Library Edition of S52 Presentation Library
Displayed for ECDIS or RADAR (ENC chart display license
available) only
(2)-1 Click on this list and code input dialog is displayed.
(2)-2 Input “0000” and additional software information is displayed.

(3) Confirm updating software version.


SLC: 01.00.088 or later
7ZPNA4519

Updating software of the MFD Application

Note
When software update starts, the tasks that are active are automatically terminated. Complete the
necessary operation such as saving of settings prior to the start of update.

1 Required Item
The following item is required to update the MFD software.
Table Required Item
No. Name Model Name
1 CD/DVD or USB memory containing software -
update data

When you want to use a USB flash memory to read or write a file, make sure in
advance that the USB flash memory is not affected by a computer virus. If the
display unit is infected with a virus, other equipment will also be infected, with the
result that a trouble will occur.

Before removing the USB flash memory, check for the access lamp of the USB flash
memory and make sure that it is not being accessed.
If you remove the USB flash memory when it is accessed, data may be destroyed and
a trouble may occur.
7ZPNA4519

2 Updating the MFD application software


(1)Set the CD/DVD or USB flash memory containing the update data.

(2)Click on the [Menu] button on the left toolbar.


The menu is displayed.

(3)Click on [Maintenance] - [Software Update] - [Software Update] on the menu.

The "Software Update" dialog box appears.

(4)Click on the [Software Update] button.

A file selection dialog box appears.


7ZPNA4519

(5)From the [Drive] combo box, select the drive you want to store updated data.

(6)From the file list, select the file MFD_Setup.exe.


MFD_xx.xx.xxxx.exe is displayed in [File name].

(7)Click on the [OK] button.


The update content confirmation dialog box appears.
7ZPNA4519

(8)Confirm the contents and click on [OK].


Installation of the update is started and the following message is displayed.

Wait for a while until the installation completes.

Note
This equipment may restart during installation.

When installation is completed, the following message is displayed.

(9)Turn off the power of this equipment.

(10)Restart this equipment.

3 Confirming the updating version


Start MFD, and confirm that the software version number has been updated in the [Software] tab by
selecting [Maintenance] - [System Information].
7ZPNA4520

Performance Monitor Information Label


on CWA-246 (26" standalone console)

Stick the MPNN46786:


PERFORMANCE MONITOR
INFORMATION LABEL
on this place.
Performance Monitor Information Label
on CWA-245 (19" standalone console)

Stick the MPNN46786:


PERFORMANCE MONITOR
INFORMATION LABEL
on this place.
Performance Monitor Information Label
on NQE-1143 (For Flash Mount type)

Stick the MPNN46786:


PERFORMANCE MONITOR
INFORMATION LABEL
on this place.
7ZPNA4521

JAN-5203

Route Planning System (RPS)

Software Updating Procedure

Index

1. OVERVIEW ..................................................................................................................................... 2

2. ITEMS FOR UPDATING .................................................................................................................. 2

3. PROCEDURE FLOW FOR UPDATING. .......................................................................................... 3

STEP1:PREPARATION ......................................................................................................................... 4

STEP2:MAKING A BACKUP COPY OF INI-FILES ................................................................................ 4

STEP3:RESTORING AN OS DISK IMAGE FOR UPDATING................................................................. 7

STEP4:RESTORING INI FILES ............................................................................................................. 8

STEP5:CONFIRMATION OF RPS SOFTWARE VERSION AND STARTING UP ................................. 10

STEP6:CLONING OF OS DISK IMAGE AND STORAGE ON BOARD ................................................ 12


JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

1. Overview
This document is described about the procedure of software updating for JAN-5203.

2. Items for updating

Items Amount Note

Recovery Boot Disc V2.1 1 Recovery Boot Disc (V2.1) for NCM-860A or
NDC-2000-M2.

JAN-5203 Update Image 1 DVD Disc containing an OS (Operating Sysytem) Disk


Image for updating.

(Maintenance No. 01.00.519)

Tools for making a backup copy 1 Take these files as below via CD-ROM or USB Media.
of INI-files
1) MFD_IniBackupTool.exe

2) ConnectionNameSet_From_AdapterName.vbs

Keyboard 1 It is used for restoring and cloning an OS Disk image..

DVD-R Media(blank) 1 It is used for cloning an OS Disk image..

Oil paint pen 1 It is used for cloning an OS Disk image..

Software Updating Procedure 1 Printout this document and take this before on boarding.

2/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

3. Procedure flow for Updating.


Procedure flow for updating software is as below. Please make sure this flow before updating.

START

Step1:Preparation

Step1:
Step2: Making a backup copy of INI-files

Step3: Restoring an OS Disk Image for updating

Step4: Restoring INI files

Step5: Confirmation of RPS software version and starting up

Step6: Cloning of OS Disk Image and storage on board

END

3/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

Step1:Preparation
1) Remove the LAN cable from RPS.

2) Turn the power off and connect a keyboard to RPS

3) Confirm that the "HASP" and "eToken" are inserted on the RPS

Step2:Making a backup copy of INI-files


1) Turn the power ON.

Caution

Left-click [OK] button when the message as below appears.

Caution

Confirm that the Hard Disk Drive is not out of order when the message as below appears.

” The application cannot start because D drive is not recognized.

Turn off the power, and turn it on again.”

2) Insert the CD-ROM or USB Media that contains some tools for making a backup copy of INI-files to
RPS.

3) On the task menu, enter a password "1074", and left click [Enter] button .

4/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

4) On the ”Manitenance Tools Startup” dialog, select ” MFD_IniBackupTool.exe” and left click
[OK] button.

5) Left click ”Backup” button on the "MFD_IniBackupTool" dialog, and then

left click [OK] button on the "Confirmation message" dialog.

6) Left click [OK] button on the dialog as below.

5/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

7) Left click [Close] button on the dialog as below.

8) In order to get back to "Task Menu", left click [OK] button on the dialog as below.

6/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

Step3:Restoring an OS Disk Image for updating


1) Insert the "Recovery Boot Disk V2.1" to CD-ROM Drive and restart RPS.

2) When a "Remove Boot DVD" message popup dialog appears, remove the "Recovery Boot Disk
V2.1". Then, insert the " JAN-5203 Update Image".

3) When a flickering of LED lamp on DVD drive stops, left click [OK] button on the message dialog.

4) Remove " JAN-5203 Update Image" after restoring disk image.

(restoring procedure takes about 15 minutes)

5) Press the power button for a while in order to turn the power off.

7/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

Step4:Restoring INI files


1) Turn the RPS power ON.

2) Left click [OK] button when the message ”JRC license file not found.” appears.

3) Insert the CD-ROM or USB Media that contains some tools for making a backup copy of INI-files to
RPS.

4) On the task menu, enter a password "1074", and left click [Enter] button .

5) On the ”Manitenance Tools Startup” dialog, select ” MFD_IniBackupTool.exe” and left click
[OK] button.

6) Left click ”Restore” button on the "MFD_IniBackupTool" dialog, and then

left click [OK] button on the "Confirmation message" dialogs

7) Left click [OK] button on the dialog as below.

8) Left click [Close] button on the dialog as below.

8/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

9) In order to get back to "Task Menu", left click [OK] button on the dialog as below.

10) Left click [OK] button when the error message dialog of ”JRC license file not found.” appears.

11) Turn the RPS power OFF.

9/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

Step5:Confirmation of RPS software version and starting up


1) Connect the LAN cable to RPS.

2) Turn the RPS power ON.

3) Select ”Route Planning Route Monitoring (ECDIS)” on the Task Menu.

4) Select "Menu" > "Maintenance" > "System Information" > "Software Tab" in order.

Comfirm that the ”Maintenance No.” displayed on the screen is "01.00.519".

5) Select "Menu" > "Code Input" in order and enter a password "0009".

6) Select "Menu" > "Service" in order. (next to "Code Input" menu)

7) Select "Installation" menu in order to get the setting of "Common Setting Items (Setting of Sensors,
Setting of SerialPort, Ship's Parameter, e.t.c.)" from SLC.

10/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

8) Wait for a while when the message dialog of ”Now getting the setting data...” appears.

Caution

Click [OK] button when the popup dialog of ”SLC/ALC connection faild.” appears.

9) Left-click "x" button on the upper-right side in order to close the "Installation" dialog.

10) Confirm that the sensor data of "GPS", "GYRO", "LOG" is displayed.

11/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

Step6:Cloning of OS Disk Image and storage on board


1) Insert "Recovery Boot Disk V2.1" into the CD-ROM drive and restart RPS.

2) Remove "Recovery Boot Disk V2.1" when the popup message dialog of "Remove Boot DVD"
appears, then insert DVD-R Media(blank).

3) When a flickering of LED lamp on DVD drive stops, left click [OK] button on the message dialog.

4) Confirm that the message as below appears, then input as ”X:¥ghost32.exe”.

5) Left-click [OK] button on the dialog of ”Abort Symantec Ghost”.

12/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

6) Select "Local" > "Disk" > "To Image" in order.

7) Select "Drive 1" and left click [OK] button.

13/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

8) Select the drive [@CD-R1 TEAC DV-W28S-W DVD drive] at the "Look in:" pull-down menu.

Select the drive "@CD-R1 TEAC DV-W28S-W DVD drive".

Caution

Make sure to select the drive [@CD-R1 TEAC DV-W28S-W DVD drive]. If not selected ,
Recovery Image CD will not be created correctly.

9) Confirm that the selected file name is "[CDR00001.GHO]" then, left click [Save] button.

14/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

10) Left click [High] button.

11) Left click [No] button.

12) Left click [Yes] button.

13) Left click [Yes] button.

15/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

Creating image process starts. (Creating process takes about 15~30 minutes)

14) Left click [Continue] button when image creation completed.

15) Select [Quit] menu.

16/17
JAN-5203_RPS_Software_Updating_Procedure(2014.11.04).doc

16) Remove the "Recovry Image CD" from DVD drive when the creation of OS Image Disk is completed.
Then, turn the RPS power off.

17) Fill in the following content with Oil paint pen onto the surface of Recovery Image CD..

・Title: Recovery Imeage CD

・Device Name: RPS


Recovery Image CD
RPS JAN-5203
・Serial Number
KGxxxxx 2014/09/24

・Mode Namel: JAN-5203 NDC-1186-4XX

・Date

・Maintenance No. Maintenance No 01.00.519

Caution

When writing Device name, Model name…. etc to Recovery Boot CD, don’t use

ballpoint pen and don’t affix the sticker printed Device name, Model name…. etc.

Otherwise Recovery Image CD doesn’t behave correctly.

18) The equipments for JAN-5203 have no storage area in the system, please keep this manual and
software update CD importantly on the ship.

All of the procedure for updating has been completed at here.

17/17
7ZPNA4522

Initializing signal process and TT setting

Note
When Initialization starts, the tasks that are active are automatically terminated. Complete
the necessary operation such as saving of settings prior to the start of initialization.

1. Required Items
The following items are required for Initialization.
- RadarSettingInit.exe
- USB flash memory

When you want to use a USB flash memory to read or write a file, make sure in
advance that the USB flash memory is not affected by a computer virus. If the
display unit is infected with a virus, other equipment will also be infected, with
the result that a trouble will occur.

Before removing the USB flash memory, check for the access lamp of the USB
flash memory and make sure that it is not being accessed.
If you remove the USB flash memory when it is accessed, data may be
destroyed and a trouble may occur.

1
7ZPNA4522

2. Flowchart

2
7ZPNA4522

2.1 Step1: Taking a Note of MBS Settings


Take a note of MBS Settings.
After executing Initialization Tool, MBS Settings have possibility to be initialized.

(1) Left-click on Menu.

(2) Left-click on Code Input on Menu page 2 and Input 0009.

(3) Left-click on Menu.

3
7ZPNA4522

(4) Service is displayed on Menu page 2.


Left-click on Service.

(5) Left-click on Adjustment.

(6) Left-click on MBS.


Take a note of Initial Level and Area Offset setting.

(7) Close Adjustment.

4
7ZPNA4522

2.2 Step2: Executing Initialization Tool


After starting Maintenance tool, execute Initialization Tool.

(1) Plug the USB flash memory copied Initialization Tool into the USB port of the trackball
operation unit.

(2) Left-click on Menu.

(3) Left-click on Code Input on Menu page 2 and Input 9999.

5
7ZPNA4522

(4) Task Menu is displayed.


Left-click on Password window and Input 1074.

(5) Maintenance Tools Startup is started.

6
7ZPNA4522

(6) After selecting the drive plugged USB flash memory out of Drive pull-down menu,
left-click on the folder copied Initialization Tool out of the folder list window.
Left-click on RadarSettingInit.exe out of Name list window.

(7) Confirm displaying of RadarSettingInit.exe next to File Name.


Left-click on OK.

(8) Left-click on OK to execute Initialization Tool.

7
7ZPNA4522

(9) After initialization is complete, left-click on OK.

(10) After being displayed the MFD reboot message, left-click on OK.

2.3 Step3: MFD Reboot


Reboot MFD.

(1) Press the power button on the trackball operation unit to reboot MFD.

8
7ZPNA4522

2.4 Step4: Confirming MBS Settings


Confirm MBS Settings.
After executing Initialization Tool, MBS Settings have possibility to be initialized.
In case MBS settings are different from the recorded settings, input MBS Settings.

(1) Left-click on Menu.

(2) Left-click on Code Input on Menu page 2 and input 0009.

(3) Left-click on Menu.

(4) Service is displayed on Menu page 2.


Left-click on Service.

(5) Left-click on Adjustment.

(6) Left-click on MBS.


Confirm Initial Level and Area Offset setting.

(7) In case the confirmed Initial Level and Area Offset setting are the same as the recorded
settings, advance to 2.5 Step5: Confirming TT Settings.
In case those settings are different, advance to (8).

(8) In case the confirmed Initial Level and Area Offset setting are different from the
recorded settings, input the recorded settings.

9
7ZPNA4522

Left-click on Initial Level window and Input recorded Initial Level setting.

(9) Left-click on Area Offset window and Input recorded Area Offset setting.

2.5 Step5: Confirming TT Settings


Confirm TT settings.
In case the confirmed TT settings are different from the initial settings, initialize TT settings.

(1) Left-click on TT.


Confirm VD Level Mode(Manual), VD Level(Manual), VD Level(Auto) setting.
In case VD Level Mode(Manual) is Manual Threshold, VD Level(Manual) is 16, VD
Level(Auto) is 30, advance to (6).
Otherwise, advance to (2)

10
7ZPNA4522

(2) Select Manual Threshold out of the pull-down menu of VD Level Mode(Manual)
window.

(3) Left-click on VD Level(Manual) window and Input 16.

11
7ZPNA4522

(4) Left-click on VD Level(Auto) window and Input 30.

Initialization is finished.

12