Footing For PS
DIMENSIONS mm
BASE COLUMN
L = 1000 h = 315
B = 900 b = 315
depth H = 200
ex = 342.5 ey = 0
v yy
BEARING PRESSURES kN/m² characteristic
punching
CORNER 1 2 3 4
no wind 0.0 46.1 0.0 46.1 0% 25% 50% 75% 100%
with wind 0.0 46.1 0.0 46.1 Efficiency
YY MOMENTS
from top m 0.608 0.293 3.11.2.2
from btm m 0.293 0.608 3.11.2.2
to zero press m 1.058 1.058 1.058 1.058 1.058 1.058
local press kN/m 26.28 26.28 22.43 22.43 20.05 20.05
M1 kNm 1.1 1.1 1.0 1.0 0.9 0.9
M2 kNm 4.9 4.9 4.2 4.2 3.7 3.7
choose M kNm 0.8 0.8 0.7 0.7 0.7 0.7
Design Myy kNm 0.8
YY SHEARS @ d from col face
from top m 0.728 0.173 3.4.5.10
from btm m 0.173 0.728 3.4.5.8
to zero press m 1.178 1.178 1.178 1.178 1.178 1.178
local press kN/m 26.28 26.28 22.43 22.43 20.05 20.05
V1 kN 4.5 4.5 3.9 3.9 3.5 3.5
V2 kN 15.5 15.5 13.2 13.2 11.8 11.8
choose V kN 3.4 3.4 2.9 2.9 2.6 2.6
Design Vyy kN 3.4
@ 2d from col face
from top m 0.848 0.053 3.4.5.10
from btm m 0.053 0.848 3.4.5.8
to zero press m 1.298 1.298 1.298 1.298 1.298 1.298
local press kN/m 26.28 26.28 22.43 22.43 20.05 20.05
V1 kN 1.4 1.4 1.2 1.2 1.1 1.1
V2 kN 17.0 17.0 14.5 14.5 13.0 13.0
choose V kN 1.0 1.0 0.9 0.9 0.8 0.8
Design Vyy kN 1.0
PUNCHING SHEAR
d ave mm Err:520 .5 x d ave Err:520 130
L R B T 195
to edges mm 842.5 157.5 450 450 Err:520
to 1.5d per mm Err:520 Err:520 Err:520 Err:520 Err:520
standard perimeter? Y,N Err:520 Err:520 Err:520 Err:520 Err:520 352.5 157.5
U mm Err:520 Err:520 Err:520 Err:520 352.5 352.5
within base? Y,N Err:520 Err:520 Err:520 Err:520 Err:520 Err:520 1 0 1 1
perimeter falls Err:520
U crit mm Err:520 1920
Area m² Err:520 0.360
As prov % Err:520
vc N/mm² Err:520
1.4G+1.6Q 1.2(G+Q+W) 1.0G+1.4W
N kN 23.6 20.2 18.0
v max N/mm² Err:520 Err:520 Err:520 Err:520 Err:520 Err:520 0 0 0
ave press kN/m² 22.64 19.37 17.54
V kN Err:520 Err:520 Err:520 15.5 13.2 11.7
v N/mm² Err:520 Err:520 Err:520 Err:520 Err:520 Err:520 0.0621 0.0530 0.0470
Project Proposed Addition of Filling Shed
Location FOOTING Made by Job No
PAD FOUNDATION DESIGN to BS 8110:1997 Single column base Date 8-Jan-99
Originated from RCC81.xls on CD © 1999 BCA for RCC sheet 3 of 3
DIMENSIONS mm
BASE COLUMN 1 (rhs) COLUMN 2 (lhs)
L = 3000 h1 = 300 h2 = 300
B = 3000 b1 = 300 b2 = 300
depth H = 750
Sex = 300 ex1 = 150 ex2 = 150
Sey = 1000 ey1 = 500 ey2 = 500
STATUS Err:520
PLOT (to scale)
BEARING PRESSURES kN/m² characteristic
CORNER 1 2 3 4 Grnd Brg Pressure 92.7%
no wind 104.5 104.5 104.5 104.5 Bending fsx
with wind 144.8 144.8 114.2 114.2
(As/Asprov) fsy
REINFORCEMENT Shear v xx
Btm Mxx - 405.0 kNm Myy - 251.7
v yy
b = 3000 mm b = 3000
d = Err:520 mm d = Err:520 punching
As = Err:520 mm² As = Err:520 0% 133%
Err:520 Err:520 Efficiency'
As prov = Err:520 mm² As prov = Err:520
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Err:520 Err:520 0
Top Mxx + 0.0 kNm Myy + Err:520 -100
d = Err:520 mm d = Err:520
-200
As = Err:520 mm² As = Err:520
-300
Err:520 Err:520
-400
As prov = Err:520 mm² As prov = Err:520
Err:520 Err:520 -500 Moment Columns Zero axis
COLUMN 2 L R B T
to edges mm 1350 1650 1000 2000 Err:520
to 1.5d per mm Err:520 Err:520 Err:520 Err:520 Err:520
standard perimeter? Y,N Err:520 Err:520 Err:520 Err:520 Err:520
U mm Err:520 Err:520 Err:520 Err:520
within base? Y,N Err:520 Err:520 Err:520 Err:520 Err:520 Err:520
perimeter falls Err:520
U crit mm Err:520
Area m² Err:520
1.4G+1.6Q 1.2(G+Q+W) 1.0G+1.4W
N kN 675.0 675.0 382.5
v max N/mm² Err:520 Err:520 Err:520 Err:520 Err:520 Err:520
ave press kN/m² 175.20 168.54 99.44
V kN Err:520 Err:520 Err:520
v N/mm² Err:520 Err:520 Err:520 Err:520 Err:520 Err:520 Err:520
COMBINED L R B T
to edges mm 1350 1350 1000 1000 Err:520
to 1.5d per mm Err:520 Err:520 Err:520 Err:520 Err:520
standard perimeter? Y,N Err:520 Err:520 Err:520 Err:520 Err:520
U mm Err:520 Err:520 Err:520 Err:520
within base? Y,N Err:520 Err:520 Err:520 Err:520 Err:520 Err:520
perimeter falls Err:520
U crit mm Err:520
Area m² Err:520
1.4G+1.6Q 1.2(G+Q+W) 1.0G+1.4W
N kN 1576.8 1544.4 927.0
ave press kN/m² 175.20 171.60 103.00
V kN Err:520 Err:520 Err:520
v N/mm² Err:520 Err:520 Err:520 Err:520 Err:520 Err:520 Err:520
For Graphs
For Graphs
2L c/l 2R 1L 1R
1.200 1.350 1.500 1.500 1.800 1.7 diff col M
-324.0 -364.5 -405.0 -405.0 -324.0 1L 1R 0.120 0.0 Right
1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.800 1.920 2.040 2.160 2.280 2.400 2.520 2.640 2.760 2.880 3.000
525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6
506.3 506.3 506.3 506.3 506.3 506.3 829.4 936.4 1049.8 1169.6 1296.0 1428.8 1568.2 1714.0 1866.2 0.0
101.3 101.3 101.3 101.3 101.3 101.3 567.0 729.0 891.0 1053.0 1215.0 1377.0 1539.0 1701.0 1863.0 0.0
-405.0 -405.0 -405.0 -405.0 -405.0 -405.0 -405.0 -324.0 -262.4 -207.4 -158.8 -116.6 -81.0 -51.8 -29.2 -13.0 -3.2 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
2L c/l 2R 1L 1R
0.850 1.000 1.150 1.850 2.150 2.0 diff col M
-162.6 -179.4 -196.3 -196.3 -162.6 1L 1R 0.085 0.0 Right
1.430 1.500 1.570 1.640 1.710 1.780 1.850 2.150 2.235 2.320 2.405 2.490 2.575 2.660 2.745 2.830 2.915 3.000
525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6 525.6
460.1 506.3 554.6 605.2 657.9 712.9 1123.9 1211.0 1301.4 1395.0 1491.9 1592.0 1695.4 1802.0 1911.9 0.0
290.3 337.5 384.8 432.0 479.3 526.5 992.3 1107.0 1221.8 1336.5 1451.3 1566.0 1680.8 1795.5 1910.3 0.0
-169.9 -168.8 -169.9 -173.2 -178.7 -186.4 -196.3 -162.6 -131.7 -104.0 -79.7 -58.5 -40.6 -26.0 -14.6 -6.5 -1.6 0.0
Single
Double
Disclaimer
All advice or information from the British Cement Association and/or Reinforced Concrete
Council is intended for those who will evaluate the significance and limitations of its contents
and take responsibility for its use and application. No liability (including that for negligence)
for any loss resulting from such advice or information is accepted by the BCA, RCC or their
subcontractors, suppliers or advisors. Users should note that all BCA software and publications
are subject to revision from time to time and should therefore ensure that they are in possession
of the latest version.
This spreadsheet should be used in compliance with the accompanying publication 'Spreadsheets
for concrete design to BS 8110 & EC2' available from British Cement Association, Telford
Avenue, Crowthorne, Berkshire RG45 6YS.
Status of spreadsheet
Public release version.