Netsure™: Itm With Esure™ Technology Row-Based, Scalable 48V DC Ups
Netsure™: Itm With Esure™ Technology Row-Based, Scalable 48V DC Ups
ITM
With eSure™ Technology
Row-based, Scalable 48V DC UPS
NetSure™ ITM
2
Unmatched Availability
LOWER TOTAL COST
Central to a data center’s strength is its overall uptime. To maintain business continuity, OF OWNERSHIP
power systems must exhibit high availability and easily scale for increasing capacity.
NetSure rectifiers or power conversion units (PCUs) are the heart of the NetSure ITM DC power is often associated with
DC UPS. Each DC UPS module includes twelve independent 5.8kW PCUs. These PCUs telecommunications where it has
are globally renowned with over 2 million units deployed, offering unmatched reliability delivered extremely high reliability for
decades. Since DC power is both
with less than 0.5% return rate (200 years MTBF). The NetSure ITM provides many
provided by backup power sources
robust features to create a highly redundant package that minimizes single points and consumed by electronic
of failure. equipment, a DC power architecture
minimizes conversion stages from grid
Proven power conversion topology Resilient design to chip, thus enabling higher overall
efficiency with increased availability.
yyEach PCU delivers conditioned, yySystem bus charges batteries and
isolated power to a common distributes power directly to the yy Factory integrated system for
fast and easy site installation
distribution bus server rack without additional
switching or conversions yy Service or expansion can be
yyPCUs function in parallel for seamless
performed while the DC UPS
redundancy without switching yy65k AIC withstand rating on AC is in operation, reducing
input breaker(s) maintenance costs
yyUnits are hot swappable in the field
without system adjustment; minimum yyController outage does not interrupt yy Compact footprint with built-in
field repair time (MTTR) increases power delivery to the critical load batteries and distribution,
overall uptime and is field replaceable without minimizes required floor space
system outage
Redundant configuration yy Designed for scalable growth to
Battery monitoring technology postpone additional capex until
yyRedundancy can be achieved both from Albér
capacity is needed
within a DC UPS module by PCU
yy Energy Optimization Mode
(N+x), and by complete system (2N) yyDetects failing battery cells before Intelligent Power Matching
they affect the critical load [Figure 1]
yyInternal power distribution through
(22) branch circuit breakers allows yyChecks each cell and associated yy
Achieves near-peak UPS
redundant A+B power paths to connections via a proactive, patented efficiency down to 5% system
each rack resistance test to reliably predict load by optimizing individual
battery performance PCU performance, greatly
yyBattery backup via three parallel reducing energy costs over
battery strings yyProvides early warning of cell time in real world conditions
problems without frequent discharge
yyOptional dual AC inputs allow tests or battery degradation; minimum yy
Matches delivered power from
upstream switchgear maintenance technician visits with maximum run
the UPS to real-time demand,
without system outage keeping a minimum of PCUs
time protection active and putting the rest
on standby
yySystem controller stores raw data
accessible via webpage or external yy
Balances the run time of each
monitoring system PCU by rotating the active and
standby units
yy
Maintains the ability to
respond quickly to changing
load conditions
3
NetSure™ ITM
4
The NetSure™ ITM easily compliments existing AC power systems, whether you are planning a
new facility or expanding an existing data center.
Ideal Applications for Reliable, Figure 3: NetSure™ ITM Row-Based Installation Examples
Scalable 48V DC Power:
yyNew and expanding small to medium
data centers
5
NetSure™ ITM
eSure™ High-Efficiency Power Conversion Unit NetSure System Controller ACU+ Excellence EB4 VRLA Battery
6
1. AC input wiring (top or bottom) 1 8
2. Power Conversion Unit (12 x 5833W)
3. ACU+ controller
2
4. 480V AC input breaker
5. AC connection point
9
6. Battery fuses
3
7. 48V DC output distribution –
22x100-200A breakers (shown); 4 6
2x500A + 4x200A fuses (optional)
5
8. Battery cooling fans
1
NetSure™ ITM Front View (bottom-cabled NetSure™ ITM Rear View (rear cover removed)
SiteWeb™ BRC with Albér® version shown with front covers removed)
Technology
Figure 4: NetSure™ ITM Internal Schematic
Industry leading battery monitoring
technology from Albér provides detailed A B A B A B A B
information and alarms regarding the
battery backup condition that will 1 13 25 37
minimize site visits and maintenance. The
AC AC AC AC
functionality of the SiteWeb™ BRC is DC DC DC DC
integrated with the system controller to
12 24 36 48
continuously monitor and test the battery
backup system at the cell or block level AC AC AC AC
DC DC DC DC
without affecting battery performance. It
measures cell internal resistance, intercell
resistance, cell voltages, battery current
and temperature. The information and
alarms can be viewed via a web browser (3 strings) (3 strings) (3 strings) (3 strings)
or connected to Liebert® SiteScan™ or
EnergyMaster™ Remote Supervision for
long term trending and analysis.
1 22 23 44 45 66 67 88
One-line diagram for a four DC UPS module system shown with circuit
SiteWeb BRC breaker output and dual AC input.
7
NetSure™ ITM
8
A Life Cycle of Expert Service and Support
Trust the service and support of your
NetSure™ ITM system to the experts at DEP
Vertiv™. Our services are offered by GN L
OY
I
DES
technical professionals who have, on
MENT
Critical
average, more than a decade of field Infrastructure
experience with DC and network Lifecycle
equipment. On the rare occasion that OP
service is required, our technicians can T I M I ZAT I ON
be at your site within hours and are
backed by an entire organization ready
to help resolve any issues. Periodic inspections identify problems power consuming equipment for
before they occur and maintain maximum maximum energy savings and provide
We offer a complete suite of services to
operating efficiency. This DC UPS service consistent network reliability through
optimize and maintain the operation of
plan provides a clear picture of system remote supervision routines that reduce
your NetSure ITM solution throughout
status and recommendations for maintenance costs.
its life cycle.
corrective steps to prevent future
Startup problems. Various scopes of work that Field Service
cover PCUs, batteries (including capacity On-site field engineers are available for
We know the risks that improper system testing), and DC distribution are available.
configuration can pose to your equipment scheduled equipment replacement,
and business. That’s why, even if a third- Available exclusively to Vertiv preventive emergency on-site technical
party has installed your system, you can maintenance customers, our secure troubleshooting or system field upgrades.
depend on us to perform site testing and customer website, FreedomCare, gives Training
verification. We will provide testing and you the capability to view and download
verification of the DC UPS, including service and maintenance visit reports. Courses, offered on-site or in our training
PCUs, batteries and control points, to center, provide knowledge in the
EnergyMaster™ Remote Supervision
ensure problems are identified before operation, control, troubleshooting and
they occur. EnergyMaster assessment and remote maintenance of the NetSure ITM.
supervision solutions provide an Design and Installation
Technical Support
integrated approach to managing the
Remote support provides an immediate energy and health of network We offer industry-leading experience and
interface with experienced technical infrastructures. Vertiv experts optimize resources to expertly design your DC UPS
experts 24 hours a day to help resolve and 48V DC distribution system. Our field
unexpected system incidents and installation team is available throughout
support you in operating and managing North America to provide local knowledge
your DC UPS. and quick response to project
requirements. Installation services offer a
Preventive Maintenance variety of options to ensure the project is
completed and tested as per agreed upon
Our preventive maintenance programs will
engineering specifications.
ensure your NetSure ITM runs at peak
system availability and establishes a
predictable maintenance budget
protected from costly emergency repairs.
9
NetSure™ ITM
10
eSure™ PCU (R48-6000Ne) – Technical Specificationsa
DC OUTPUT
Output Power 5833W maximum
Regulation Steady state output voltage remains within +/-0.25% for any combination of input voltage from 5% to 100% load
Wide Band Noise Does not exceed 250 mv peak-to-peak, or 100 mv rms per Telcordia GR-947-CORE
Psophometric Noise Does not exceed 1 mv from 10% to 100% load
PROTECTION
Current Limiting The output current is limited to 110 amps
Over Current Internal fuse
PHYSICAL CHARACTERISTICS
Mounting Plug-in installation, hot swappable
Dimensions (H x W x D) – in. (mm) 3.36 x 8.83 x 14.62 (85.5 x 224.5 x 371.5)
Weight – lb. (kg) 22 (10)
BATTERY BACK-UP TIME (MINUTES)
DC UPS Single module Two modules Three modules Four modules
Load 70kW 140kW 210kW 280kW
10kW 130 300 480 630
20kW 55 130 210 300
30kW 28 90 130 180
40kW 17 55 90 130
50kW 12 41 70 100 Peace of mind. It’s confidence
64kW 7 24 50 75 you’ve done everything possible
70kW 3 21 43 69
80kW 17 34 55
to assure system uptime. It’s
90kW 14 27 47 confidence the DC UPS you rely
100kW 12 22 40 on is operating at peak performance.
110kW 10 19 34
120kW 8 17 28
It’s confidence you’ve selected the
134kW 6 16 25 best partner available to sustain
140kW 3 14 22
your critical network infrastructure.
150kW 12 19
160kW 10 17
That is Vertiv™.
170kW 9 15
180kW 8 14
190kW 7 13
204kW 4 11
210kW 2 10
220kW 9
230kW 9
240kW 8
250kW 7
260kW 6
274kW 3
280kW 1
11