VI - Safety Techniques: Definitions
VI - Safety Techniques: Definitions
In this chapter we discuss some of the more significant and common safety techniques and
introduce some of the vocabulary used by safety equipment manufacturers like Honeywell to
describe features and benefits of their products. The information provided is not intended to
replace, and must not be used to replace, our detailed instructions for use or operation.
Definitions
Electrosensitive protective equipment (ESPE) example, a main contactor, a magnetic clutch or an
An assembly of devices and/or components working electrically operated hydraulic valve. When fitted, a
together for protective tripping or presence sensing MSCE is normally controlled by the Secondary
purposes. As a minimum this comprises: Switching Device (SSD).
• a sensing function
Final Switching Device (FSD)
• a control/monitoring function
The component which, when signaled by the OSSD
• an output signal switching device (OSSD)
going to the OFF state, responds by interrupting the
Output signal switching device (OSSD) circuit connecting the machine control system to the
The component of the ESPE connected to the machine primary control system.
machine control system which, when the sensing
Secondary Switching Device (SSD)
function is actuated during normal operation,
A device which, in a lock-out situation, performs a
responds by going to the OFF state.
back up function by going to the OFF state, and
Machine primary control element (MPCE) initiating an appropriate machine control action -
The electrically powered element that directly e.g. de-energizing the machine secondary control
controls the normal operation of a machine in such a element (MSCE).
way that it is the last element (in time) to function
Normally Closed (NC) Contacts
when machine operation is initiated or arrested. This
Contacts which are closed in the “rest” (or un-
can be, for example, a main contactor, a magnetic
energized) state. External actuation forces them
clutch or an electrically operated hydraulic valve.
open, breaking the circuit.
Machine secondary control element (MSCE)
Normally Open (NO) Contacts
A machine control element, independent of the
Contacts which are open in the “rest” (or un-
primary control element(s), that is capable of
energized) state. External actuation forces them
removing the source of power from the prime mover
together, initiating the circuit.
of relevant hazardous parts. This can be, for
y
ESPE OSSDs
Diagram VI.1
START RESTART
INTERLOCK INTERLOCK
MUTE FSD
SSD
monitoring
MACHINE
FSDs
MAIN
POWER
MSCE MPCEs
○
• In negative mode a signal is generated only
○
○ Welded broken
on detection. Some internal fault could lead ○
contacts spring
○
module)
• In positive mode a signal is permanently
○
Welded broken
○
Diagram VI.2
Diagram VI.3
Diagram VI.4
4. Start/Restart Modes
• Automatic mode - turning the equipment on and off after any interruption and release
automatically resets it.
• Start and Restart Interlock - at start up and after any interruption and release, a manual reset
must be done, normally with a push-button.
Honeywell safety equipment can operate in either mode. An optional mode is offered on some of
our products:
• Start Interlock - where the system is only operational at power-up after an external push-button
has been activated. It starts again automatically after each interruption and release.
Introduction • Industrial Safety Products • 29
5. Redundancy 6. Self-checking