High quality soy oil for


delicious dishes
Quality assurance with the
optical sensor OUSAF21

For quality assurance, the soybean oil has to be filtered in an elaborate process, which incurs
high costs.

Benefits at a glance: The quality of soy oil is determined chlorophyll concentration is outside
by its color. The coloration is the permissible range or other limit
• Reliable quality assurance different when undesirable values are exceeded. In this case, the
by measuring the optical substances such as chlorophyll or soy oil can be returned to previous
color concentration other substances are present. To process stages for reprocessing.
avoid contamination and to achieve Another challenge, besides the costly
• Optimized clay consumption the best quality, a special filtration filtering process, are process pressure
which can result in high savings and absorption process is used, and temperature conditions, which
on the filter material which needs to be monitored for must be considered and observed at all
optimal results. In order to reduce times during the process. Normally
• The investment pays off within a operating costs, as little filtration the temperature is around 80°C and
very short time due to the ideal material as possible should be used, the pressure amounts 2 bar (g).
dosage of the filter material while still ensuring efficient
filtration. Our Solution
Endress+Hauser supports operators to
Customer challenge ensure the product quality of the soy
During the clarification process of soy oil and the profitability of the
oil, a special, expensive clay is used to operation. In addition to the Liquiline
bind the undesirable substances, such CM44P transmitter, the optical sensor
as chlorophyll. The dosage of this clay OUSAF21 is installed in the plant to
is proportional to the chlorophyll measure the concentration. First of all,
concentration. With the help of online the correct correlation between the
monitoring a more precise and measured value of the OUSAF21 in
economical dosing system for the clay AU and the chlorophyll concentration
is possible. needs to be identified. Therefore,
It also allows to react quickly in case of several laboratory samples are
unforeseen events. For example, if the evaluated. Once the correct correlation
is found, the sensor helps to improve clay is very expensive and accounts for Components 
the process. On the one hand, the about 70% of the operating costs, The Endress+Hauser solution includes
sensor serves as a quality barrier if the even the smallest improvements can the following components:
oil does not meet the corresponding lead to enormous savings. Thanks to • Optical sensor for the measurement
specifications. Consequently, the oil Endress+Hauser’s automation of low color concentrations
can be reprocessed to achieve the solution, manual sampling is no OUSAF21-
required quality standard. longer necessary. This had previously Y0C0D1D3C4A1A,Y=71306716
On the other hand, OUSAF21 controls caused inconsistencies and prevented • Cable set CUK80-4E15A
a control circuit for the precise dosage the fast adjustment of the clay dosage. • Multichannel transmitter
of the clay that removes the impurities These savings succeed regardless of Liquiline CM44P-
from the soybean oil. This optimizes the fluctuating quality of soybeans due AAFIHP1M01A1F010BAAA
both process time and costs. to climatic conditions, which also
affects the clay dosage.
Results and benefits
Operators benefit above all from the
optimized dosage of the clay. As the

Color sensor OUSAF21 for low color concentrations