Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Project 1

31.12.2020

Operator
Telephone
Fax
e-Mail

QP client 1 typical / Summary

Height of Room: 3.000 m, Mounting Height: 3.055 m, Light loss factor: Values in Lux, Scale 1:40
0.80

Surface  [%] Eav [lx] Emin [lx] Emax [lx] u0


Workplane / 685 459 833 0.670
Floor 20 525 388 607 0.738
Ceiling 80 188 144 222 0.767
Walls (4) 50 402 189 695 /

Workplane:
Height: 0.760 m
Grid: 32 x 32 Points
Boundary Zone: 0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.650, Ceiling / Working Plane: 0.274.

Luminaire Parts List

No. Pieces Designation (Correction Factor)  (Luminaire) [lm]  (Lamps) [lm] P [W]
Thorn 92920058 OP2 3800-840 CKIT+ MPT
1 4 3800 3800 29.9
E3 Q600 [STD] (1.000)
Total: 15200 Total: 15200 119.6

Specific connected load: 12.07 W/m² = 1.76 W/m²/100 lx (Ground area: 9.91 m²)