NonTendered Elevation

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

THIS DRAWING WITH ITS DESIGN IS THE PROPERTY OF N


ARCHITECTS' STUDIO AND IS MERELY LOANED TO THE
+10350 mm LVL
HEAD ROOM ROOF LVL BORROWER / CLIENT UPON AGREEMENT THAT THEY WILL NOT
W E
BE REPRODUCE / SCANNED / EXHIBITED UNLESS PERMITTED

1.500
BY ARCHITECTS' STUDIO IN WRITTEN TO THE BORROWER / S
CLIENT .

+8850 mm LVL
PARAPET LVL
1.050

1.050
LVL +600
LVL +600 LVL +600 LVL +600 LVL +600
+7800 mm LVL
TERRACE FLOOR LVL
GENERAL NOTES:
1.500

LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL
LVL 1. ALL DIMENSIONS ARE IN
+450 +00 +450 +00 +450 +00 +450 +450 +00 +450 +00 +450 +00 +450 +450 +00 +450 +00 +00 +450 +450 +00 +450 +00 +450 +00 +450 +00 +450 +00 +450
+450
+6300 mm LVL MILLIMETERS UNLESS MENTIONED.
3.600

1ST FLOOR LINTEL LVL


2. DRAWINGS SHALL NOT BE
1.350
10.350

MEASURES, FOLLOW WRITTEN


+4950 mm LVL DIMENSIONS.
0.750

1ST FLOOR SILL LVL


3. ANY DISCREPANCY IN THE
+4200 mm LVL
1ST FLOOR LVL DRAWING OR ANY OTHER
LVL +5000 DRAWINGS RELATED TO THIS
1.500
DWG NO :

LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL DRAWING SHALL BE BROUGHT TO
+2700 mm LVL
+450 +450 +450 +450 +450 +450 +450 +450 +450 +450 +450 +450 +450 THE NOTICE OF THE ARCHITECTS
3.600

GF LINTEL LVL
ONE WEEK PRIOR TO EXECUTION
1.350

OF WORK AT SITE.
+1350 mm LVL
4. ALL STRUCTURAL MEMBERS LIKE
0.750

GF SILL LVL
BEAMS, COLUMNS ETC. SHALL BE
+600 mm LVL PROVIDED AS PER STRUCTURAL
PLINTH LVL
0.600 DRAWINGS AND DETAILS.
+00 mm LVL
FG LVL 5. ALL WALLS ARE 250 MM THICK
UNLESS SPECIFIED.
6. PLINTH LEVEL SHOULD BE FIXED
FRONT SIDE ELEVATION JUDICIOUSLY CONSIDERING THE
SITE CONTOUR , ROAD FORMATION
& DRAINAGE , ETC

SPECIFICATIONS
C +10350 mm LVL
HEAD ROOM ROOF LVL
1.500

1. THE FLOORS OF ALL ROOMS (EXCEPT


+8850 mm LVL TOILET) SHALL BE FINISHED WITH
PARAPET LVL
KOTA STONE OF GOOD QUALITY OVER
1.050

1.050

LVL +600 LVL LVL +600 LVL +600


M-10 CEMENT CONCRETE
+00
+7800 mm LVL
TERRACE FLOOR LVL
2. THE FLOORS OF TOILETS SHALL BE
LVL LVL FINISHED WITH ANTISKID CERAMIC
1.500

+00 +00 LVL LVL LVL LVL LVL LVL LVL AND DADO UPTO 2.0 MTR. HT. WITH
LVL LVL LVL LVL LVL LVL LVL LVL
+00 +00 +00 +00 +00 LVL +00 +00 GLAZED TILES.
+450 +450 +450 +450 +450 +450 +450 +450
+6300 mm LVL
LVL LVL 3. THE VENTILATORS SHALL BE
3.600

1ST FLOOR LINTEL LVL +450


+450 +450 ALUMINUM FRAMED WITH GLAZING
1.350

4. STAIRCASE RAILINGS SHALL BE OF


10.350

STAINLESS STEEL OF APPROVED


+4950 mm LVL
0.750

1ST FLOOR SILL LVL PATTERN & DESIGN


5. THE EXTERNAL SURFACE SHALL BE
D +4200 mm LVL
1ST FLOOR LVL FINISHED WITH WEATHER COAT OF
APPROVED SHADE
1.500

LVL LVL LVL LVL LVL LVL LVL LVL 6. THE INTERNAL SURFACE SHALL BE
+450 +450 +450 +450 +450 +450 +450 +450 FINISHED WITH DISTEMPER OF
+2700 mm LVL
3.600

GF LINTEL LVL APPROVED SHADE WITH WALL PUTTY


1.350

7. CONCEALED WIRING WITH P.V.C.


PIPES SHALL BE PROVIDED BOTH FOR
+1350 mm LVL ELECTRICAL & P.H. WORKS
0.750

GF SILL LVL
8. FOUNDATION SHOULD BE PROVIDED
+600 mm LVL AS PER SOIL CONDITION
PLINTH LVL
9. G.I. PRESSED ,G.I. DOOR ASSEMBLY
0.600
WITH POLYMER POWDER COATED &
UPVC WINDOW
10. FOR SALINE AREAS -DOORS &
REAR SIDE ELEVATION WINDOWS OF POWDER COATED
ALUMINUM FRAME WITH 12MM
E PRE-LAMINATED PARTICLE BOAR
11. ENERGY SAVING UTILITIES SHOULD BE
PROVIDED
+10350 mm LVL 12. MINIMUM 6.0 MTR. OPEN SPACE
HEAD ROOM ROOF LVL
SHOULD BE PROVIDED AROUND THE
1.500

BUILDING FOR MOVEMENT OF FIRE


BRIGADE VEHICLE.
+8850 mm LVL
PARAPET LVL
1.050

1.050

LVL +600 LVL +600


+7800 mm LVL
TERRACE FLOOR LVL
1.500

LVL LVL LVL LVL LVL LVL LVL LVL LVL LVL
+00 +00 +00 +00 LVL
+450 +450 +450 +00 +450 +450
+6300 mm LVL +450 NOTES:
3.600

1ST FLOOR LINTEL LVL

THE DRAWINGS IS COMPILED


1.350

F
10.350

+4950 mm LVL ACCORDING TO CBSE & NATIONAL


0.750

1ST FLOOR SILL LVL

+4200 mm LVL
BUILDING CODE 2016
1ST FLOOR LVL
1.500

LVL LVL LVL LVL


+2700 mm LVL
+450 +450 +450 +450
3.600

GF LINTEL LVL
1.350

CLIENT :
+1350 mm LVL
PROPOSED MODEL SCHOOL BUILDING OF
0.750

GF SILL LVL

+600 mm LVL
PLINTH LVL
"ODISHA ADARSHA VIDYALAYA"
+00 mm LVL 0.600 SCHOOL & MASS EDUCATION ,GOVT. OF ODISHA
FG LVL

G ARCHITECTS :
RIGHT SIDE ELEVATION
ARCHITECTS ENGINEERS PLANNERS INTERIOR DESIGNERS

E/47, INFOCITY, BHUBANESWAR, ODISHA


+10350 mm LVL
HEAD ROOM ROOF LVL
1.500

DESIGNATION DEALT BY CHECKED BY DATE SIGN

ARCHITECT SWAGATIKA
+8850 mm LVL
PARAPET LVL STRUCTURAL ENG NILAKANTHA
LVL
1.050

1.050

ELECTRICAL ENG SUSHIL


+00
+7800 mm LVL
TERRACE FLOOR LVL
APPROVED PH ENG HUSSAIN
INTERIORS KISHAN
1.500

LVL LVL LVL LVL LVL LVL LVL LVL PROJECT :


+450 +450 +450 +450 +450 +450 +450 +450
H +6300 mm LVL
3.600

1ST FLOOR LINTEL LVL


CHIEF ENGINEER (Buildings) ,WORKS DEPTT. PROPOSED MODEL SCHOOL BUILDING
1.350

LVL
10.350

+00
+4950 mm LVL DEALTH CHECKED REMARK
NO DATE DESCRIPTION FOR REV
0.750

1ST FLOOR SILL LVL BY BY

5 -
+4200 mm LVL
1ST FLOOR LVL
4
1.500

3 -
LVL LVL LVL
+2700 mm LVL
+450 +450 +450 STATE PROJECT DIRECTOR PRINCIPAL SECRETARY ADVISER -cum -WORKING PRESIDENT 2 -

-
3.600

1
GF LINTEL LVL
OAVS School & Mass Education,Odisha OAVS
*
SCHEMATIC TENDER GFC AS BUILD
1.350

DRAWING DRAWING DRAWING DRAWING


DRAWING TITLE : STAMP
+1350 mm LVL
0.750

GF SILL LVL

+600 mm LVL Checked by: Er.B.K.Biswal Checked by: Er.J.Das ELEVATION


PLINTH LVL
I +00 mm LVL 0.600 Technical Consultant , OAVS Asst. Engineer , OAVS SIGNATURE
FG LVL

REV
R0
DATE : SCALE : 1:150
LEFT SIDE ELEVATION NO PROJ NO : SHEET NO : 4
DWG
NO : OAVS/02/2020/4
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17