Sketch Plan: Cagayan de Oro Baikingon Misamis Oriental

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

N

TECHNICAL DESCRIPTIONS
LINES BEARINGS DISTANCES
LOT 1
SKETCH PLAN
1-2 14.58 M.
2-3 14.07 M. OF
3-4 20.49 M.
4-5 35.49 M. LOT 1 FROM LOT 10,PCS-10-002966 &
5-1 16.54 M. LOT 4561-C, CSD-10- 003605- D
AS PREPARED FOR
MINDANAO COOPERATIVES WATER SERVICE FEDERATION
SITUATED IN THE
BARRIO OF BAIKINGON
MUN./CITY OF CAGAYAN DE ORO
PROVINCE OF MISAMIS ORIENTAL
ISLAND OF MINDANAO
Containing an area of 543 SQ.M.
BEARINGS TRUE
SCALE 1: 1,500 mtrs.
This is to certify that this is true and correct plan of
LOT 1 FROM LOT 10, PCS- 10 -002966 & LOT 4561-C, CSD- 10- 003605- D,
____________________________________________________
PLOTTED HEREIN IN ACCORDANCE WITH THE RECORDS AND FILE FROM
____________________________________________________
DENR-10.
____________________________________________________
____________________________________________________
(Certified Correct).

________________________________
Geodetic Engineer

_________________________________
Registration Certificate No. & Date Issue

NOTE: This is issued thru the request of ___________________


_________________________________ for Reference not for
Registration purposes.

S
N

SKETCH PLAN
OF
LOT 1 FROM LOT 10,PCS-10-002966 &
LOT 4561-C, CSD-10- 003605- D
AS PREPARED FOR
MINDANAO COOPERATIVES WATER SERVICE FEDERATION
SITUATED IN THE
BARRIO OF BAIKINGON
MUN./CITY OF CAGAYAN DE ORO
PROVINCE OF MISAMIS ORIENTAL
ISLAND OF MINDANAO
Containing an area of 543 SQ.M.
BEARINGS TRUE
SCALE 1: 1,500 mtrs.
This is to certify that this is true and correct plan of
LOT 1 FROM LOT 10, PCS- 10 -002966 & LOT 4561-C, CSD- 10- 003605- D,
____________________________________________________
PLOTTED HEREIN IN ACCORDANCE WITH THE RECORDS AND FILE FROM
____________________________________________________
DENR-10.
____________________________________________________
____________________________________________________
(Certified Correct).

________________________________
Geodetic Engineer

_________________________________
Registration Certificate No. & Date Issue

NOTE: This is issued thru the request of ___________________


_________________________________ for Reference not for
Registration purposes.

S
14.00m

2.80m 2.80m 2.80m 2.80m 2.80m

2.80m

2.80m
GARDEN NET GARDEN NET GARDEN NET GARDEN NET

2.80m

2.80m
GARDEN NET GARDEN NET GARDEN NET GARDEN NET
2.80m

2.80m
GARDEN NET GARDEN NET GARDEN NET GARDEN NET GARDEN NET
16.80m

2.80m

2.80m
GARDEN NET

NURSERY GARDEN NET

22.40m
2.80m

2.80m
GARDEN NET GARDEN NET GARDEN NET GARDEN NET GARDEN NET
R
2.80m

2.80m
GARDEN NET GARDEN NET GARDEN NET GARDEN NET GARDEN NET
O
0.50m
1.50m

1.00m

2.80m
ELEV. + 0.10m
GARDEN NET GARDEN NET
A
2.62m

WAITING
AREA
ELEV. + 0.25m

W1

2.80m
GARDEN NET GARDEN NET
D1
2.33m

COOKING ROOM/
KITCHEN WITH
3.50m

STOVE
W1
OFFICE
D3

D3
D2
13.62m

1.30m

ELEV. D4
W3 + 0.20m
4.68m

D3 ACID RESISTANT
PREPARATION
TABLE
2.20m

STORAGE/
WEIGHING ROOM

ANTE-ROOM

D5

D5
4.00m

4.00m

W2
INCUBATION CULTURE W2

ROOM ROOM
1.03m

W2 W2

0.17m
1.03m 2.48m 2.48m 1.02m 2.80m 2.80m

14.00m

GR OUN D FLO OR PL AN
SCALE: 1:100MTS
PROPOSED FCOF TISSUE CULTURE
BAIKINGON, IPONAN, CDOC
JUNE 30, 2021

You might also like