Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

1tx_1550.

sor
01.03.2022 23:52:41
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 625
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 1.5 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.580, -5.856] dB; 5.372 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 0.629
ORL: 35.311

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -23.262
* R 0.00550 * -23.208 * *
1 R 0.12807 >6.000 -47.318 *4.913 0.629
1tx_1550.sor
01.03.2022 23:52:41
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 625
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 1.5 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.580, -5.856] dB; 5.372 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 0.629
ORL: 35.311

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -23.262
* R 0.00550 * -23.208 * *
1 R 0.12807 >6.000 -47.318 *4.913 0.629
2tx_1550.sor
02.03.2022 00:06:16
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 628
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 3.5 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.632, -5.104] dB; 5.453 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 2.153
ORL: 34.026

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -24.372
* R 0.00550 * -24.546 * *
1 R 0.07351 -0.410 -35.055 *26.124 1.510
* R 0.09148 * -34.620 * *
* R 0.09437 * -34.550 * *
* R 0.09694 * -34.488 * *
* R 0.09951 * -34.426 * *
* R 0.10207 * -34.363 * *
* R 0.10464 * -34.301 * *
* R 0.10721 * -34.239 * *
* R 0.10977 * -34.177 * *
2 R 0.12838 24.454 -36.930 *12.085 2.173
2tx_1550.sor
02.03.2022 00:06:16
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 628
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 3.5 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.632, -5.104] dB; 5.453 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 2.153
ORL: 34.026

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -24.372
* R 0.00550 * -24.546 * *
1 R 0.07351 -0.410 -35.055 *26.124 1.510
* R 0.09148 * -34.620 * *
* R 0.09437 * -34.550 * *
* R 0.09694 * -34.488 * *
* R 0.09951 * -34.426 * *
* R 0.10207 * -34.363 * *
* R 0.10464 * -34.301 * *
* R 0.10721 * -34.239 * *
* R 0.10977 * -34.177 * *
2 R 0.12838 24.454 -36.930 *12.085 2.173
3rx_1550.sor
02.03.2022 00:09:18
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 629
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 3.5 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.616, -5.899] dB; 5.372 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 0.026
ORL: 34.592

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -21.544
1 R 0.12871 24.407 -43.552 0.086 0.011
3tx_1550.sor
02.03.2022 00:12:19
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 630
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 3.5 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.648, -0.000] dB; 5.965 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 15.974
ORL: 61.216

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -47.512
1 R 0.12901 >6.000 -42.814 -9.919 -1.280
4rx_1550.sor
02.03.2022 00:14:36
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 631
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 1.0 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.628, -5.895] dB; 5.373 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: -0.783
ORL: 33.631

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -20.574
1 R 0.13031 >6.000 -66.041 -3.792 -0.494
4tx_1550.sor
02.03.2022 00:15:33
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 632
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 1.0 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.637, -5.898] dB; 5.374 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 0.022
ORL: 34.917

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -21.844
1 R 0.12741 >6.000 -65.630 *0.707 0.090
5tx_1550.sor
02.03.2022 00:19:03
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 634
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 1.0 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.639, -6.092] dB; 5.355 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 0.034
ORL: 35.866

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -22.776
1 R 0.12901 >6.000 -54.854 *2.215 0.286
5tx_1550.sor
02.03.2022 00:19:03
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 634
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 1.0 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.639, -6.092] dB; 5.355 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 0.034
ORL: 35.866

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -22.776
1 R 0.12901 >6.000 -54.854 *2.215 0.286
6rx_1550.sor
02.03.2022 00:20:53
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 635
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 1.0 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.630, -5.901] dB; 5.373 dB/div Averaging Time: 0:15
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 4.890
ORL: 26.448

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -22.164
1 R 0.12934 3.168 -23.969 *2.207 3.453
2 R 0.26088 19.666 -54.311 *12.216 5.060
6tx_1550.sor
02.03.2022 00:22:00
SunLite OTDR #93314
SM-1550
Cable ID:
Fiber ID: 636
Fiber Type: [G.652] conventional SM fiber
Originating Location:
Terminating Location:
Line Status: as-built condition
Trace Type: standard trace
Operator:
Comment:
Refractive Index: 1.46
Backscattering coef.: -80 dB
Acquisition range: 1.0 km
Distance Range: 1.0 km
First data point: -0.00283 km
Last data point: 0.49832 km
Sampling Resolution: 0.32 m
X: [-0.00283, 0.49832] km; 0.05012 km/div Pulse Width: 3 ns
Y: [-59.629, -5.900] dB; 5.373 dB/div Averaging Time: 0:14
Analysis parameters:
Event Loss Threshold: 0.020 dB
Reflectance Threshold: -65.000 dB
End of Fiber Threshold: 6.000 dB
End-to-end loss: 5.816
ORL: 28.101

# Distance, km Splice loss, dB Reflectance, dB OF loss, dB/km Cumulative loss, dB


0 R 0.00000 -21.973
1 R 0.12871 4.697 -26.808 *0.550 4.768
2 R 0.25928 18.999 -58.419 *6.621 5.632

You might also like