Professional Documents
Culture Documents
FL-PP-RJ45... / FL CAT5... : Ethernet Patch Panel
FL-PP-RJ45... / FL CAT5... : Ethernet Patch Panel
FL-PP-RJ45... / FL CAT5... : Ethernet Patch Panel
Data sheet
104622_en_07 © PHOENIX CONTACT 2020-09-07
1 Description Features
– CAT5e
FL-PP-RJ45... / FL CAT5... patch panels provide the
transition from the field cabling to the cabling inside the – 8-pin assignment: 1:1
control cabinet. – 10/100/1000 Mbps
The patch panel is connected to the end device via the RJ45 – Mounting on a DIN rail
jack using a pre-assembled patch cable. Pre-assembled – Safe connection to ground potential
patch cables in different connection lengths from 0.24 m to – PoE-capable in accordance with IEEE 802.3bt, type 4
20 m are available for this. – FL-PP-RJ45/RJ45-B with extended temperature range
The field cabling is applied easily to spring, screw, or LSA -40 °C ... 85 °C
connection terminal blocks, depending on the version. The – Multiple options for securing field cables:
individual terminal blocks are clearly labeled for connection
– Spring connection terminal blocks
according to Ethernet standard TIA 568 A and B as well as
– Screw connection terminal blocks
PROFINET. There is no longer any need to spend time and
effort crimping an RJ45 connector to the field line. – LSA connection terminal blocks
– RJ45-RJ45 transition
– ATEX approval for the following patch panels:
– FL-PP-RJ45-SCC
– FL-PP-RJ45-SC
– FL-PP-RJ45/RJ45
– Shipbuilding approval according to DNV GL for the
following patch panels:
– FL-PP-RJ45-SCC
– FL-PP-RJ45-SC
– FL-PP-RJ45-LSA
– FL-PP-RJ45/RJ45
– FL CAT5 TERMINAL BOX
Make sure you always use the latest documentation. It can be downloaded at phoenixcontact.net/products.
This data sheet is valid for the products listed on the following page:
FL-PP-RJ45... / FL CAT5...
2 Table of contents
1 Description.................................................................................................................................. 1
2 Table of contents ......................................................................................................................................................... 2
3 Ordering data.............................................................................................................................. 3
3.1 Accessories.................................................................................................................................................... 3
3 Ordering data
Products Type Order No. Pcs./Pkt.
Patch panel, one RJ45 jack to 8 spring-cage connection ter- FL-PP-RJ45-SCC 2901642 1
minal blocks (1:1 assignment), CAT5e, 10/100/1000 Mbps,
DIN rail adapter, IP20, option of shield contacting to the DIN
rail via jumpers
Patch panel, one RJ45 jack to 8 screw connection terminal FL-PP-RJ45-SC 2901643 1
blocks (1:1 assignment), CAT5e, 10/100/1000 Mbps, DIN
rail adapter, IP20, option of shield contacting to the DIN rail
via jumpers
Patch panel, one RJ45 jack to 8 LSA connection terminal FL-PP-RJ45-LSA 2901645 1
blocks (1:1 assignment), CAT5e, 10/100/1000 Mbps, DIN
rail adapter, IP20, option of shield contacting to the DIN rail
via jumpers
Patch panel, two RJ45 jacks (1:1 assignment), CAT5e, FL-PP-RJ45/RJ45 2901646 1
10/100/1000 Mbps, DIN rail adapter, IP20, option of shield
contacting to the DIN rail via jumpers
Patch panel, narrow overall width, extended temperature FL-PP-RJ45/RJ45-B 2904933 1
range, two RJ45 jacks, 1:1 assignment, all-around shield,
CAT5, 10/100 Mbps, DIN rail adapter, IP20
Patch panel, one RJ45 jack to 4 screw connection terminal FL CAT5 TERMINAL BOX 2744610 1
blocks (assignment 1, 2, 3, 6), CAT5, 10/100 Mbps, DIN rail
adapter, IP20, shield contacting on DIN rail
3.1 Accessories
4 Technical data
Ethernet interface FL-PP-RJ45- FL-PP-RJ45- FL-PP-RJ45- FL-PP-RJ45/ FL-PP-RJ45/ FL CAT5
SCC SC LSA RJ45 RJ45-B TERMINAL
BOX
Connection Spring Screw LSA RJ45 RJ45 Screw
connection connection connection
Cable diameter [mm] 6 ... 10 6 ... 10 6 ... 10 - - 6 ... 10
Conductor cross
section [mm2]
Rigid 0.2 ... 1.5 0.14 ... 1.5 0.128...0.325 - - 0.14 ... 1.5
Flexible 0.2 ... 1.0 0.14 ... 1.0 0.128...0.325 - - 0.14 ... 1.0
AWG 24 ... 16 26 ... 16 26 ... 22 - - 26 ... 16
Pin assignment 1:1 1:1 1:1 1:1 1:1 1, 2, 3, 6
Connection RJ45 CAT5e RJ45 CAT5
Transmission rate 10/100/1000 Mbps 10/100 Mbps
Transmission length 100 m (including patch cables)
Cable impedance 100 Ω
Insertion cycles ≤ 2500
General data
Degree of protection IP20
Weight 45 g 55 g 55 g 39 g 33 g 39 g
Dimensions 29 x 90 x 53 29 x 90 x 53 29 x 90 x 53 29 x 90 x 53 22,5 x 78 x 44 25 x 90 x 52
W / H / D [mm]
Housing material PVC/PA
Current consumption <1 A
Ambient conditions
Ambient temperature
Operation -25 °C ... 70 °C -40 °C ... 85 °C -25 °C ... 70 °C
Assembly -10 °C ... 70 °C -40 °C ... 85 °C -10 °C ... 70 °C
Storage/transport -25 °C ... 85 °C -40 °C ... 85 °C -25 °C ... 85 °C
Max. permitted humidity 25 % ... 95 % (non-condensing)
(operation)
Vibration resistance 5g, 150 Hz, 2.5 h, in XYZ direction
according to
IEC 60068-2-6
Shock test according to 25g, 11 ms period, half-sine shock pulse
IEC 60068-2-27
4
1 2 3 6
2
1 YE 1 WH/GN 1 WH/OG
5 1
Ø
2 OG 2 GN 2 OG
4 5 7 8
6 3 WH 3 WH/OG 3 WH/GN
6 BU 6 OG 6 GN
4 BU 4 BU
5 WH/BU 5 WH/BU
7 WH/BN 7 WH/BN
3
8 BN 8 BN
1 2 3 6
4 5 7 8
Figure 3 Required stripping lengths
89,6
– a = 10 mm
– b = 40 mm
– c = 8 mm
4
1 2 1 YE 1 WH/GN 1 WH/OG
Ø
5 14 2 OG 2 GN 2 OG
25
6 37 3 WH 3 WH/OG 3 WH/GN
68
6 BU 6 OG 6 GN
4 BU 4 BU
5 WH/BU 5 WH/BU
7 WH/BN 7 WH/BN
3 8 BN 8 BN
– a = 10 mm
– b = 35 mm
– c = 5 mm
4
1
Ø
2 1 YE 1 WH/GN 1 WH/OG
5 14 2 OG 2 GN 2 OG
25
6 37 3 WH 3 WH/OG 3 WH/GN
68
6 BU 6 OG 6 GN
4 BU 4 BU
5 WH/BU 5 WH/BU
7 WH/BN 7 WH/BN
3 8 BN 8 BN
a b
– a = 10 mm
– b = 50 mm
9.2 Dimensions
59,8
29 52,3
89,6
1 YE 1 WH/GN 1 WH/OG
5 2 2 OG 2 OG
2 GN
4 3 WH 3 WH/OG 3 WH/GN
1 2 3 6
6 BU 6 OG 6 GN
59,8
24,5 52,3
– a = 10 mm
– b = 10 mm
89,6
– c = 5 mm
1
Ø
1
Ø
1
Ø
1
Ø
13 Circuit diagrams
RJ45
RJ45 1 1
1 2 1
3 2
6 3
6
4 8
8
5
7
8
14 Disposal
Figure 17 FL-PP-RJ45-SCC (2901642) Dispose of the patch panel separately from other
FL-PP-RJ45-SC (2901643) waste, i.e., via an appropriate collection site.
FL-PP-RJ45-LSA (2901645)
RJ45 RJ45
1 1
8 8
1MΩ 1nF
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
S S
104622_en_07 PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany 15 / 15
phoenixcontact.com