VRV Indoor Units

High Static Pressure Duct Type


FXMQ-P
Easy maintenance
High static pressure allows for flexible duct design.
• Inspection and cleaning is facilitated by separating
the inspection opening and the drain pan maintenance check hole.
Separate inspection opening

Design flexibility
Adjustable external static pressure Drain pan maintenance
check hole

• Using a DC fan motor, the external static pressure can be


controlled within a range of 50 Pa to 250 Pa.

Adjustable external static pressure

50 Pa 250 Pa • Heat exchanger, drain pan and fan deck can be easily
accessed and removed from bottom for maintenance.

Easy installation
“Airflow rate auto adjustment function” at field setting
(local setting by remote controller) Duct resistance at
designing system
rpm 1
*This function can only be set via wired remote controller. Actual duct
rpm 2 resistance Specifications
External static pressure (ESP)

Various adjustments are required MODEL FXMQ200PVM FXMQ250PVM


Field setting
without “airflow rate (Due to excess or deficiency of Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz

Indoor Units
Design Installation airflow) e.g. Duct re-construction,
auto adjustment function”
Motor replacement, Damper Btu/h 76,400 95,500
replacement, etc. Cooling capacity
rpm 7 System kW 22.4 28.0
operation Power consumption kW 0.55 *1 0.67 *1
Field setting Innovating
rpm 8 Casing Galvanised steel plate
Design Installation
with “airflow rate Function!
auto adjustment function” m3/min 74/61/50 84/71/58
Airflow rate (HH/H/L)
by remote controller cfm 2,612/2,153/1,765 2,965/2,506/2,047

Rated airflow Airflow External static pressure Pa 50-250 (150) *2 50-250 (150) *2
<Mechanism>
1. During field setting, power input of DC fan is detected. Sound level (HH/H/L) dB(A) 42/38/35 44/40/37
Notes: ”Airflow rate auto adjustment function” can be adjusted within ±10% of rated
2. External static pressure is estimated from power input of DC fan because PCB Dimensions (H × W × D) mm 470×1,490×1,100 470×1,490×1,100
airflow. (Refer to Engineering Data Book for details)
of FXMQ-P has table of external static pressure vs. power input of DC fan.
”Airflow rate auto adjustment function” should be used at field setting only. Machine weight kg 95 105
3. Actual duct resistance is calculated according to 1 and 2.
4. Fan speed is automatically adjusted to produce rated airflow. Liquid (Flare) 9.5
Piping
connections
Gas (Flange) mm 19.1 22.2
Drain BSP1”
Notes: Specifications are based on the following conditions;

Built-in pre-filter slot • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
• To cater for easy installation of filter at site, During actual operation, these values are normally somewhat higher as a result of ambient conditions.
*1: Power consumption values are based on conditions of rated external static pressure.
a filter rail is available at the return flange. *2: External static pressure can be modified using a remote controller that offers fifteen levels of control.
These values indicate the lowest and highest possible static pressures. The standard static pressure is 150 Pa.

149 150