Atul Ji First Roof (1) - P

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

41'-0"

BACKBONE STRUCTURAL
S-8 S-8
D-6"
CONSULTANTS

4'-0"
D-6"
24, KARNI NAGAR
4'-0"

13'-112" 13'-112"

JHOTWARA, JAIPUR
11'-712" 11'-712"

30 32 34 36 38
40 S-2
D-6"
10'-612"
28
42
ARCHITECTS :
S-2
16'-0"

16'-0"
D-6" 26
44

24
46
Ar. RISHABH GOEL
DEVISE
406, Krishna Enclave , Tonk Road,
4'-2"

Bapu Nagar, Jaipur


14'-9" AC SLEEVE +91-9116999996
AC SLEEVE

Email:- rishabhgoel432@gmail.com
S-1
D-6"
6'-712" 6'-412"

47'-1012"
4'-3" S-6 14'-9" 5'-3"
PROJECT DETAILS:
5'-3"

5'-3"
D-6"
8'-712"

8'-712"

ATUL SAHU
RESIDENCE
AC SLEEVE
61'-112"

GENERAL NOTES:-
20'-1012"

7'-712" 3'-3" 1. ALL DIMENSION ARE IN MM.


2. THIS DRAWING SHOULD BE READ IN CONJUNCTION
WITH RELEVANT ARCHITECTURAL AND SERVICE
S-5 DRAWING ANY DISCREPANCY SHOULD BE
D-6" IMMEDIATELY BROUGHT TO NOTICE.

REINFORCEMENT DETAILS
12'-9"

12'-9"

1. HIGH YIELD STRENGTH DEFORMED BARS MARKED


S-3
21'-712"

AS Ø WITH CHARACTERISTIC STRENGTH 500 N/MM2


D-6" CONFORMING TO IS 1786-1985, SHALL BE USED.
2. LAP SHALL BE STAGGERED SO THAT NO MORE THAN
AC SLEEVE
1/3 OF BARS SHALL BE LAPPED AT ANY SECTION

3. LAP LENGTH FOR HEIGH YIELD STRENGTH DEFORMED


14'-9"
BARS SHALL BE AS FOLLOW. WHERE Ø IS DIA OF BARS.
CONC.GRADE Ldt / LAP
M-20 57Ø
M-25 49Ø
AC SLEEVE M-30 46Ø
11'-712" 14'-9"
CONCRETE DETAILS
S-4
D-6" 1. GRADE OF CONCRETE SHALL BE M-30 CONFORMING
TO IS 456-2000 UNLESS OTHERWISE NOTED.
11'-712" 4'-112" 2. CLEAR COVER OF CONCRETE IN INCHES TO THE
MAIN REINFORCEMENT UNLESS SPECIFIED
13'-6"
12'-3"

OTHERWISE SHALL BE :-

11'-7" 4'-112" PRTICULAR BOTTOM TOP SIDES


S-7 FOOTING 2"(50MM.) 2"(50MM.) 2"(50MM.)
D-7" COLUMNS 1 1/2"(40MM.)
6'-9"

6'-9"

WALLS,FLOOR 1"(25MM.)
ON WATER FACE
13'-3"

SLAB & ROOF


SLAB OF 1 1/2"(40MM.)
WATER TANK. (ON ERTH SIDE)
WHERE APPLICABLE

NOTES:
11'-712" 14'-412" 11'-7" 4'-112" 1. GRADE OF CONCRETE SHALL BE M-25 FOR ALL FOOTINGS AND WALLS.
3'-0"

3'-0"

3'-0"

3'-0"

S-8 S-7 2. GRADE OF STEEL SHALL BE Fe-500 TMT.


(FROM PRIMARY PRODUCERS ONLY)
D-7" D-7" 3. GRADE OF CONCRETE SHALL BE M-30 FOR WATER TANK WALLS.

45'-1012"
MARK DATE DESCRIPTION

REVISION:

AREA -2495 sqft PROJECT NO.:

DRAWN BY: VIRENDRA

CHECKED BY: RAHUL

FILE LOCATION :

SHEET TITLE:

FIRST ROOF FRAMING PLAN


NOTE
1. MIX OF CONCRETE FOR SHALL BE M-25.
2. GRID LINE SHALL BE FOLLOW AS PER ARCHITECTURAL DRAWING
4. MAXIMUM NO. OF BARS IN A SINGLE LAYER SHALL BE 3 FOR 9",
4 FOR 12",6 FOR 18",8 FOR 24",10 FOR 30" WIDE BEAM.
5. THE GAP BETWEEN TWO LAYER OF BARS EITHER ON TOP OR
DATE 19.07.2022
BOTTOM SHALL BE 1"
6. PROVIDE 2-#12 AT TOP & BOTTOM AT CUTOUT. NORTH:
7. FOLLOW GENERAL NOTES DRAWING FOR DETAILING.
8. FOLLOW WRITTEN DIMENSION ONLY..
2#12 B/W DRAWING NO. S-08
9. SUNK SHALL BE AS PER ARCH DRAWING.
10. DOWELS SHALL BE LEFT FOR STAIR CASE.
11. STEEL GRADE SHALL BE Fe-500.
T/B SHEET NO. 00
REVISION 00
TYPICAL CUT-OUT DETAIL SCALE 1:50 U.N.O.