49 CFR Ch. I (10-1-11 Edition) 178.337-10: Chlorine Cargo Tanks. Angle Valves
49 CFR Ch. I (10-1-11 Edition) 178.337-10: Chlorine Cargo Tanks. Angle Valves
I (10–1–11 Edition)
(iii) Mark each hose assembly with § 178.337–10 Accident damage protec-
the month and year of its original pres- tion.
sure test. (a) All valves, fittings, pressure relief
(8) Chlorine cargo tanks. Angle valves devices, and other accessories to the
on cargo tanks intended for chlorine tank proper shall be protected in ac-
service must conform to the standards cordance with paragraph (b) of this sec-
of the Chlorine Institute, Inc., Dwg. tion against such damage as could be
104–8 or ‘‘Section 3, Pamphlet 166, caused by collision with other vehicles
Angle Valve Guidelines for Chlorine or objects, jack-knifing and over-
Bulk Transportation.’’ (IBR, see § 171.7 turning. In addition, pressure relief
of this subchapter). Before installation, valves shall be so protected that in the
each angle valve must be tested for event of overturn of the vehicle onto a
leakage at not less than 225 psig using hard surface, their opening will not be
dry air or inert gas. prevented and their discharge will not
(c) Marking inlets and outlets. Except be restricted.
for gauging devices, thermometer (b) The protective devices or housing
wells, and pressure relief valves, each must be designed to withstand static
cargo tank inlet and outlet must be loading in any direction equal to twice
marked ‘‘liquid’’ or ‘‘vapor’’ to des- the weight of the tank and attach-
ignate whether it communicates with ments when filled with the lading,
liquid or vapor when the cargo tank is using a safety factor of not less than
filled to the maximum permitted fill- four, based on the ultimate strength of
ing density. A filling line that commu- the material to be used, without dam-
nicates with vapor may be marked age to the fittings protected, and must
‘‘spray-fill’’ instead of ‘‘vapor.’’ be made of metal at least 3⁄16-inch
(d) Refrigeration and heating coils. (1) thick.
Refrigeration and heating coils must (c) Rear-end tank protection. Rear-end
be securely anchored with provisions tank protection devices must:
for thermal expansion. The coils must (1) Consist of at least one rear bump-
be pressure tested externally to at er designed to protect the cargo tank
least the cargo tank test pressure, and and all valves, piping and fittings lo-
internally to either the tank test pres- cated at the rear of the cargo tank
sure or twice the working pressure of from damage that could result in loss
the heating/refrigeration system, of lading in the event of a rear end col-
whichever is higher. A cargo tank may lision. The bumper design must trans-
not be placed in service if any leakage mit the force of the collision directly
occurs or other evidence of damage is to the chassis of the vehicle. The rear
found. The refrigerant or heating me- bumper and its attachments to the
dium to be circulated through the coils chassis must be designed to withstand
must not be capable of causing any ad- a load equal to twice the weight of the
verse chemical reaction with the cargo loaded cargo tank motor vehicle and
tank lading in the event of leakage. attachments, using a safety factor of
The unit furnishing refrigeration may four based on the tensile strength of
the materials used, with such load
be mounted on the motor vehicle.
being applied horizontally and parallel
(2) Where any liquid susceptible to
to the major axis of the cargo tank.
freezing, or the vapor of any such liq- The rear bumper dimensions must also
uid, is used for heating or refrigera- meet the requirements of § 393.86 of this
tion, the heating or refrigeration sys- title; or
tem shall be arranged to permit com-
(2) Conform to the requirements of
plete drainage. § 178.345–8(d).
[Order 59–B, 30 FR 580, Jan. 16, 1965. Redesig- (d) Chlorine tanks. A chlorine tank
nated at 32 FR 5606, Apr. 5, 1967] must be equipped with a protective
EDITORIAL NOTE: For FEDERAL REGISTER ci- housing and a manway cover to permit
wreier-aviles on DSK3TPTVN1PROD with CFR
tations affecting § 178.337–9, see the List of the use of standard emergency kits for
CFR Sections Affected which appears in the controlling leaks in fittings on the
Finding Aids section of the printed volume dome cover plate. For tanks manufac-
and at www.fdsys.gov. tured on or after October 1, 2009, the
142
VerDate Mar<15>2010 14:56 Jan 03, 2012 Jkt 223216 PO 00000 Frm 00154 Fmt 8010 Sfmt 8010 Y:\SGML\223216.XXX 223216
Pipeline and Hazardous Materials Safety Admin., DOT § 178.337–14
more than 3⁄4 NPT equipped with a [Amdt. 178–29, 38 FR 27599, Oct. 5, 1973, as
valve having an integral excess flow amended by Amdt. 178–89, 54 FR 25018, June
valve or excess flow feature. 12, 1989; Amdt. 178–118, 61 FR 51340, Oct. 1,
[64 FR 28050, May 24, 1999] 1996]
143