Figure 1. Dosimeter Set-Up

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

INTRODUCTION  1 X-ray Plug-in module with W X-

ray tube
Dosimetry is a subspecialty of medical  1 X-ray Capacitor plate for X-ray
physics that deals with the determination unit
and calculation and assessment of dose rates  1 X-ray holder for capacitor plates
including the absorbed dose, absorbed dose  1 X-ray fluorescent screen
rate and the equivalent dose produced by the  1 X-ray optical bench
ionizing radiation and absorbed by the  1 X-ray Diaphragm tube 2 mm
human body. This applies both internally,  1 X-ray Diaphragm tube 5 mm
caused by ingested or inhaled radioactive  1 Slide mount for optical bench
substances and externally due to irradiation  1 Power supply, regulated, 0...600 V-
by sources of radiation. Internal  1 DC measuring amplifier
dosimetry assessment depends on a variety  2 Digital multimeter
of monitoring, bio-assay or radiation  1 High value resistor, 50 MΩ
imaging techniques. External dosimetry is  1 Adapter, BNC socket / 4 mm plug
based on measurements with a dosimeter, or pin
inferred from measurements made by other
 1 Screened cable, BNC, l = 30 cm
radiological protection instruments.
 1 Connecting cable, l = 25 cm, 32 A,
Dosimetry is used for human radiation
blue
protection and is also used to monitor
occupational radiation workers, where  1 Connecting cable, l = 25 cm, 32 A,
irradiation is expected, or where radiation is red
unexpected.  2 Connecting cable, l = 10 cm, 32 A,
blue
 3 Connecting cable, l = 50 cm, 32 A,
PROCEDURE red
 3 Connecting cable, l = 50 cm, 32 A,
blue
 2 Connecting cable, l = 75 cm, 32 A,
red

First, find out the distance x0 between the


aperture and the radiation source by
removing the capacitor plates and inserting
the different diaphragm tubes. The diameter
of the pattern can be recognized on the
Figure 1. Dosimeter set-up fluorescent screen at maximum values of
anode voltage and current under subdued
To start off with the experiment, the students light. Measure the intervals necessary for the
must first set up the equipment as shown in approximate determination of the distance
Figure 1. The equipment needed for the set x0 with a ruler. Next, measure the ionization
up are as follows: current with apertures of d = 2 mm and d = 5
mm at maximum anode voltage and anode
current, as a function of the capacitor
 1 XR 4.0 X-ray expert unit voltage. After that, measure the ionization
current as a function of anode current at
maximum anode and capacitor voltages.
Then, the ionization current with apertures
of d = 5 mm at maximum anode current as a
function of the capacitor voltage at various
anode voltages.