Pac Unit - Installation

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

SERVICE CLEARANCE

MODELS: PY036 - PY150 MODELS: PY180 - PY360


X, D D
BO
OL R
TR TO
CON R MO
OR WE
L F LO
NE & B
PA O R
SS S
CCE PRES
A OM
C

ACCESS PANEL FOR


EVAPORATOR COIL

B
E T
INL
IR
E RA
NS
DE
C ON

NOTE: All dimensions are in cm.


MODEL DIMENSIONS MODEL DIMENSIONS
NUMBER A B C D E NUMBER A B C D E
PY036 85 105 105 150 90 PY180 120 90 115 250 120
PY048 85 105 105 150 90 PY210 120 90 115 250 120
PY060 85 105 105 150 90 PY240 120 90 115 250 120
PY075 90 105 105 200 90 PY300 120 90 115 250 120
PY090 90 105 105 200 90 PY340 120 90 115 250 120
PY100 90 105 105 200 90 PY360 120 90 115 250 120
PY120 90 105 105 200 90 A : Clearance dimension from condenser coil & compressor access panel
PY150 90 105 105 200 90 B : Clearance dimension from filter access panel
A : Clearance dimension from condenser coil C : Clearance dimension from electrical control box, blower & motor/evaporator access panel
B : Clearance dimension from electrical control box, blower & motor/evaporator access panel D : Clearance dimension over the condenser fan
C : Clearance dimension from condenser coil E : Clearance dimension from condenser coil
D : Clearance dimension over the condenser fan
E : Clearance dimension from filter access panel

RIGGING INSTRUCTIONS
ATTENTION TO RIGGERS
• Insert 2" nominal pipe through holes in the base rail as shown in the figure below for slings.
• Holes in base rail are centered around the unit center of gravity.
• Use wooden pallet or spreader bar when rigging, to prevent the slings from damaging the unit.
• Rollers may be used to move the unit on the roof or ground.

CAUTION: All panels should be in place when rigging.

MODELS: PY036 - PY360


LIFT LIFT

SPREADER BAR

PROPER CLEARANCE TO BE
PROVIDED

COMPRESSOR
END

MUST BE 2" NOMINAL PIPE THRU UNIT FOR SLINGS TO AVOID BASE DAMAGE

4
UNIT MOUNTING

ROOF
CONCRETE PAD
CONDENSATE DRAIN CONNECTION
• Use standard PVC pipe with NPT connection for the condensate drain. Provide a 'P' trap immediately at the condensate drain connection.
• Piping has to be sloped away from the unit.
• Remember to remove the drain hole plug before operating the unit. Avoid bends & elbows.

DUCT CONNECTION
The units can be connected to the ducting in horizontal configuration. Connect ducting using flexible duct connection. The duct should
be properly designed and the drive package should match the required CFM & corresponding external static pressure.

ATTENTION: Avoid abrupt changes in size and/or direction of duct to ensure proper unit performance.

ELECTRIC HEATERS
Electric heater kit is installed as an externally mounted kit at the supply air opening.

UNIT WEIGHT & WEIGHT DISTRIBUTION


TOTAL WEIGHTS (Kg.)
MODEL WEIGHT
NUMBER (Kg.) K G L N M H R Y
PY036 195 60 45 52 38 - - - -
PY048 213 66 48 58 41 - - - -
PY060 215 66 49 58 42 - - - -
PY075 335 95 83 86 71 - - - -
PY090 360 107 86 93 74 - - - -
PY100 440 128 101 116 95 - - - -
PY120 445 130 102 118 95 - - - -
PY150 450 131 103 119 97 - - - -
PY180 800 155 104 166 98 145 132 - -
PY210 840 170 106 176 99 151 138 - -
PY240 970 190 120 200 116 177 167 - -
PY300 975 192 120 201 116 177 169 - -
PY340 1030 215 124 223 118 179 171 - -
PY360 1323 220 138 200 128 150 165 164 158

K H R G

CONDENSER SECTION

L M Y N
=

SUPPLY AIR RETURN AIR


5
UNIT DIMENSIONS
PY180 - PY360

CONTROLS ACCESS PANEL S


ACCESS PANEL FOR BLOWER & MOTOR
CONDENSER COIL M

CONTROL COMPARTMENT
CONDENSATE DRAIN OUTLET
A\IR IN 3/4" NPT
POWER INLET

A\IR IN (OPTIONAL)
FRESH AIR OPENING/HOOD

CONDENSER COIL
AIR IN SUPPLY AIR RETURN AIR

TOP VIEW

F AIR OUT
K U H N
CONTROL BOX
ACCESS PANEL
COMPRESSOR
ACCESS PANEL

CONDENSER COIL SUPPLY AIR RETURN AIR OPENING


R

OPENING

ACCESS PANEL
C

FILTER
[9.17] DRAIN OUTLET
233

[5.67]
144
POWER INLET
D X X G D
G L
B B
A 16 x 25mm
MOUNTING SLOT (3EACH SIDE)
MOUNTING SLOT (4EACH SIDE-PY/PQ360)
SIDE VIEW FRONT VIEW SIDE VIEW

DIMENSIONS
MODEL
A B C D F G H K L N R S M U X

PY180 - PY210 2794(110) 1778(70) 1266(49.83)1715(67.52) 1737(68.37) 197(7.75) 817(32.17) 720(28.35) 1200(47.25) 83(3.27) 912(35.9) 666(26.22) 194(7.64) 171(6.73) -

PY240 - PY340 3048(120) 2196(86.44) 1446(56.94) 2135(84.1) 2152(84.72) 324(12.76) 915(36.02) 740(29.13) 1200(47.25) 84(3.31) 1050(41.34) 666(26.22) 289(11.38) 194(7.64) -

PY360 3683(145) 2184(86) 1446(56.94)2125(83.66) 2184(86) 42(1.65) 938(36.93) 527(20.75) - 97(3.83) 1000(39.37) 680(26.77) 254(10) 372(14.65) 1125(44.29)

NOTE:
1. All dimensions are in mm (dimensions in brackets are in inches).

You might also like