FRESH WATER GENERATOR

STOPPING PROCEDURE

1. PUSH ALARM CUT BUTTON.

2. FULL OPEN JACKET HEATING BYPASS VALVE. No. 13 V.

3. CLOSE HEATING INLET VALVE. No. 11 V.

4. CLOSE HEATING OUTLET VALVE. No. 12 V.

5. OPEN VACUUM BREAKER.

6. STOP FRESH WATER DISTILLATE PUMP AND CLOSE DELIVERY VALVE.

( LET THE SYSTEM COOL DOWN FOR 20 ~ 30 MINUTES OR SHELL TEMP.


DROPS TO 20 DEG CENT. )

7. CLOSE FEEDING VALVE.

8. SWITCH OFF CHEMICAL INJECTION PUMP.

9. SWITCH OFF SALINITY INDICATOR POWER.

( AT LOWER FLOOR )

10. STOP EJECTOR PUMP.

11. CLOSE OVERBOARD VALVE No. 133 V.

12. CLOSE EJECTOR PUMP SUCTION AND DELIVERY VALVE.

13. OPEN DRAIN VALVE FOR SEA WATER AT EVAPORATOR SIDE.

-----0--- FINISH ---0------