This document provides the specifications for a portable 12-lead electrocardiograph machine. Key details include: it can acquire 12-lead data simultaneously, operates for 1 hour on rechargeable batteries, has a 128x64 pixel LCD display showing 3 ECG channels, performs arrhythmia analysis and automatic tests, and prints to 63mm wide thermal paper rolls. The device is classified for medical use and measures ECG signals from 0.5-40Hz with high common mode rejection.
This document provides the specifications for a portable 12-lead electrocardiograph machine. Key details include: it can acquire 12-lead data simultaneously, operates for 1 hour on rechargeable batteries, has a 128x64 pixel LCD display showing 3 ECG channels, performs arrhythmia analysis and automatic tests, and prints to 63mm wide thermal paper rolls. The device is classified for medical use and measures ECG signals from 0.5-40Hz with high common mode rejection.
This document provides the specifications for a portable 12-lead electrocardiograph machine. Key details include: it can acquire 12-lead data simultaneously, operates for 1 hour on rechargeable batteries, has a 128x64 pixel LCD display showing 3 ECG channels, performs arrhythmia analysis and automatic tests, and prints to 63mm wide thermal paper rolls. The device is classified for medical use and measures ECG signals from 0.5-40Hz with high common mode rejection.
NAME : 1/2/3CH PORTABLE INTERPRETATIVE ELECTROCARDIOGRAPH
TYPE : C120 MERK : FUKUDA M.E KOGYO NEG. ASAL : JAPAN
SPECIFICATION
* 12 Lead Simultaneous Data Acquisition
* Power Supply : AC 100 - 240V, 50 /60 Hz DC 9,6V Ni-MH Rechargeable battery Battery capsity : 1 ( one ) hour continuous operation Charging time : 3 ( three ) hours * Power consumption : 30VA ( Max ) * Input : Floating circuit * Input Impedance : Greather than 0.01mA * Operation temperature : +10 to +40°C * Time constant : over 3,2 sec * Filter / digital HUM : -20dB at 50 / 60Hz DRIFT : -3dB at 0,5Hz EMG : -3dB at 20 / 30 / 40Hz * Operation Humidity : 25 to 95% Non-condensing * Operation atmosphire : 70kPa to 106kPa * Analysis in Arrhythmia Check Recording * Automatic Nervous Function * Auto ID Number function automatically count ID number one by one after recording in auto mode * Recording copy * Self Test and Test Pattern * Operation : Auto / Manual * Setting : Recording channel 1, 2 & 3 * A/D conversion : 12 bits * ECG Sampling Data Rate : 600Hz, 1,66ms * Unit Weight : 2,4 kg including a rechargeable battery * LCD : 128 x 64 dots 3 channel waves * The Interpretation function is based on the accurate measurement of ECG data * CMRR : within 10mm ( p-p ) on the chart * Leakage current : Less than 0,01mA * Dimension : 280 (W) x 202 (D) x 87 (H) mm * IEC Classification : Class 1, type CF * Paper : 63mm x 30mt ( Roll, Fold type) * Frequency respon : 0,5 - 40 Hz ( Filtered in HUM+DRIFT+EMG at 40Hz ) 0,05 - 100 Hz ( unfiltered ) * The suitable sensitivity is selected : 1/2, 1, 2 cm/mV and AUTO by 1/4, 1/2, and 1