Budiyanto Mulianto

February 2016
• Data Center Design
• Physical Components
• Network Devices
 Make it Robust
 Make it Modular
 Make it Flexible
 Standardize
 Promote Good Habits
Shoes Rack
FM 200

Network Room Meeting Room

Up
Ramp

Operation

15.00m.
Up
Command Center
Room

Storage Staging Electrical & UPS


Server Room
Room Room Room
Up

42.00m.

9.00m. 33.00m.
 Operation Command  Electrical & UPS Room
Center Room
 Fire Suppression Room
 Server Room
 Storage Room  Staging Room

 Network Room  Meeting Room


International Standard
• TIA-942 has been ratified in April 2005 as
The Telecommunications Infrastructure
Standards for Data Centers
– Site Spaces & Lay-out
– Cabling Infrastructure
– Tiered Reliability
– Environmental Consideration
 Spaces
 Raised Floor System
 Environmental Monitoring System
 Smoke Detection System & Fire Protection System
 Air Condition and Humidifier System
 Rack System
 Uninterruptible Power Supply
 Electrical Generator System
 Structured Cabling System
 CCTV & Access Security System
• Raised Floor
• Ceiling
• Partition
• Construction
• Painting & Final Finishing
• Media Ducting atau Media Distribusi Udara untuk AC
Presisi
• Instalasi Perkabelan (Kabel Data, Kabel Voice dan
Kabel Power)
• Instalasi Pemipaan (Pemipaan Cooling Systems dan
Pemipaan Fire Suppression)
• Instalasi Control Systems, sehingga ruangan tersebut akan
terlihat rapi dari segi estetika
Raised Floor
The Panel

Finishing
Core
Edging
Backing

Raised Floor tipe Bare Panelnya terbuat dari bahan plat besi, dengan Warna Panel
Grey (Abu-abu),.
Raised Floor tipe HPL Panelnya telah dilapisi dengan bahan Vinyl Anti Statis atau
lebih dikenal dengan istilah HPL (High Pressure Laminated) berwarna White Grey
(Putih bercak abu-abu),
Environmental Monitoring System

optional : Alert :
To Monitor :
1. Email / SMS
1. Air Conditioner 1. Motion
2. UPS Status 2. SNMP
2. Rack Door Open / Close
3. Water Leakage 3. Alarm
4. Fire Suppression 3. Pressure / Air Flow 4. Voice Dialing
5. Temperature & Humidity
Structured Cabling and Rack System

• Cabling Systems
(Fiber Optic &
UTP)
• Centralize Data
Communication

• Perforated Rack
For airflow system
Uninterruptable Power Supply ( UPS)

1. Power Distribution Local


2. Avoidance data interruption.
3. Minimize hardware problem
4. Secure business continuously
Generator System

1. Distribution Power System


2. Emergency Power Data Center
3. Generated PLN local
Access Security System
1.Administrator System.
2.Security IT Data Center
3.Protection Access
CCTV System

1.Monitoring
Infrastructure
Data Center.
2.Capture
documentation
3.Security
Management
system
Air Condition and Humidifier
System
• Provide increased cooling system availability.
• Effectively remove the heat load from the computer room.
• Protection from equipment downtime or damage.
• Temperature degree of the ambient humidity and airflow
• Approximately 16-24 degrees Celsius
Cold and Hot Aisle
Pendinginan tanpa
Plenums/Exhaust Ducting
Pendinginan dengan saluran
melalui ceiling/loteng dengan jalur
kembali melalui Plenums ke CRAC
PRECISION AIR CONDITIONING & FIRE EXTINGUISHING
(CONTROL & INTEGRATION)

Ruang Server

Gas FM-200
Fire Panel
PRECISION
AIR
CONDITIONING
10 DETIK
NETWORK
PERIPHERALS
N

(Shutdown)

Air Grille
Raised Floor
Documentation
• Proper documentation is key to a managed
data center
• Data Centre documentation consists at least
out of :
– Design plan and layouts
– Equipment / asset lists
– Maintenance contract
– Policies, procedures and
work instructions
– Forms (request for change)
– Test plans, test results,
action plans