Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

List of Alarm delays

Appear TV Platform

 Appear TV AS Tel: +47 24 11 90 20


PO Box 8 Lilleaker Fax: +47 24 11 90 21
NO-0216 Oslo Email: support@appeartv.com
Norway appeartv.com

Doc. Name : List of Alarm Delays


Doc. Name : Engineering
Revision : 3.24
Revision : 1.1
Date : 30.10.2016
Date : 26.09.2011
Appear TV

1 Revision History
Version Date Name Comment
1.0.0 10.05.2012 Pallavi Katpilwar Initial version

2 List of alarm delays use for switching criteria for Appear TV


redundancy:
Module Error Set Delay Clear Delay
ASI No Sync 0 5
IP Input No bitrate 10 1
IP Input No signal 4 1
IP Input Input stream is scrambled 0 10
IP Input Link down 1 10
DVB-C No bitrate 10 1
DVB-C No signal 4 1
DVBS2 No Lock 1 5
DVB-T No bitrate 10 1
DVB-T No signal 4 1
CI No CAM 0 7
ECMG Critical Channel Errors 0 0
ECMG Major Channel Errors 0 0
EMMG/PRIVG Critical Channel Errors 0 0
PSI PAT Missing 0 0
PSI PMT Missing 0 0
Switch Input stream is scrambled 0 10
Switch Link down 1 10
Switch No bitrate 10 1
Switch No signal 1 3

Please note that it is not possible to change these delays and they are fixed in the system.

3 Reference Document:

Topic Reference document Section


Redundancy- Triggers AppearTV User Manual 11: Redundancy Support
Alarm AppearTV User Manual 12.1.4 Active Alarms

27/09/2016 2