Result of Inspection: Conclusion
Result of Inspection: Conclusion
PICTURE OF EQUIPMENT
INSPECTION RESULTS
The unit should be periodically examined and tested at interval not exceeding 6 (six) month, but more frequent interval is needed with the objectives of
enviromental condition, result of previous examination, length of service time and statutory requirements.
No apparent discountinuities were detected through Magnetic Particle Inspection in welds of the critical areas of lifting points.
There is no apparent discountinuities were detected along critical area of lifting point during Magnetic Particle Inspection after Drop Test
Conclusion :
Based on document evaluation and field inspection PT LD Servis concluded that the lifting equipment can be used according to codes and standards and we
recommend the lifting equipment to be used for operations with safe workloads and Max Gross Mass. as stated above.
EQUIPMENT DETAILS
Description Toolbox Macaroni Manufacture Elnusa Fabrikasi Konstruksi
Serial Number HMRB-06 / 1000000132880 Date of Manufacture August 2020
Dimension 10290 (L) x 1200 (W) x 1320 (L) mm Colour Code Solid Blue
GENERAL CONDITION
Essntial and Non Redundanct Availabelity Corrosion Deformation Crack Result Remarks
Top & bottom side rails Yes No Yes No Yes No Yes No Accepted
Top & bottom end rails Yes No Yes No Yes No Yes No Accepted
Primary Structures
INSPECTION RESULTS
The dimensional examination (s) have been satisfactorily completed in accordance with standard reference used and customer requirement, Dimensional check
were done based on above reference standard
Conclusion :
Based on document evaluation and field inspection PT LD Servis concluded that the lifting equipment can be used according to codes and standards and we
recommend the lifting equipment to be used for operations with safe workloads and Max Gross Mass. as stated above.
EQUIPMENT DETAILS
Description Type of Inspection :
Four Legged Wire Rope Slings Thimble eyes type, with ferrule
Visual Inspection NDT NDT (Non Destructive Test)
secure each end sling c/w Master Link Assembly at Upper And
Function Test Magnetic Particle Test
Serial Number FJ20H 2286 Dimensional check Dye Penterant Test
Manufacture Franklin Offshore Last of examination
Date of Manufacture August 2020 • Date : February 19, 2021
Work. Load Limit (WLL) 19.2 Tons @ 0 - 45º • Tested by : PT Akura Bina Citra
Colour Code Solid Blue • Type examination :
Internal Procedure LDS-LT-20 LDS-LT-07 Visual NDT NDT (Non Destructive Test)
Ref. Code BS EN 13414 ANSI B30.9 Dimensional check Magnetic Particle Test
BS EN 1677 ANSI B30.20 Function Test Dye Penterant Test
GENERAL CONDITION
WIRE ROPE SLINGS MASTER LINK AND SUB. LINKS
Broken wire >1 wire Yes No Reduction of rope diameter > 10% Yes No Missing / Illegible Identification Yes No Pitting
External wear Yes No Basket or lantern deformation Yes No Exessive Wear Yes No Yes No
Decrease elasticity Yes No Wire protrusion Yes No Nick Yes No Weld Spater
Fracture of strand Yes No Local increase in rope diameter Yes No Gouges Yes No Yes No
Defect
Defect
Flattened protion Yes No Core of strand protrusion Yes No Stretched Link or Component Yes No 10% Reduction dim.
Waviness Yes No distorsion Yes No Bend Yes No Yes No
Kink Yes No Corrosion Yes No Twisted Yes No
Damage Yes No Severe Rust Yes No Deformation Yes No
Bend Yes No Other : Yes No Heat Damage Yes No
INSPECTION SUMMARY
Dimension
Evaluation
Diameter Length Width
Wire Rope Data REMARK
(A) (B) (C)
Accepted Rejected
mm mm mm
Wire Rope 24 5415 N/A √ -
INSPECTION RESULTS
The dimensional examination (s) have been satisfactorily completed in accordance with standard reference used and customer requirement, Dimensional check were done based on
above reference standard
Conclusion :
Based on document evaluation and field inspection PT LD Servis concluded that the lifting equipment can be used according to codes and standards and we recommend the lifting
equipment to be used for operations with working load limit as stated above.
EQUIPMENT DETAILS
Description Bow Anchor Shackle Bolt and Nut Type With Safety Pin Ref. Code : BS EN 13889 ANSI B30.26
Serial Number See Table BS 3551 ANSI B30.20
Manufacture Crosby Vanbeest Gunnebo Internal Procedure : LDS-LT-02
Other Type of Inspection :
Size 1 Inch Visual Inspection NDT NDT (Non Destructive Test)
Work. Load Limit (WLL) 8.5 Tons Function Test Magnetic Particle Test
Type Bolt & Nut Anchor Screw Pin Dimensional check Dye Penterant Test
Model G-2130 G-4163 855 Colour Code : Solid Blue
GENERAL CONDITION
Missing / Illegible Identification Exessive Wear Weld Spater Last of examination
Yes No Yes No Yes No Date : February 19, 2021
Stretched Component Twisted Pitting Tested by : PT Akura Bina Citra
Yes No Yes No Yes No Type examination :
Defect
10% Reduction dimesional Nick Other Visual NDT NDT (Non Destructive Test)
Yes No Yes No Dimensional check Magnetic Particle Test
Exessive Wear Gouges Function Test Dye Penterant Test
Yes No Yes No NOTE (If any comments) :
Heat Damage Bend
Yes No Yes No
INSPECTION SUMMARY
Shackle Dimension Evaluation
Serial Number Width Inside (D) Length Inside Remarks
Ø Bow (A) mm Ø Pin (B) mm Ø Eye (C) mm Accepted Rejected
mm (E) mm
FJ20H 2287 25 28 59 43 95 √ - -
FJ20H 2288 25 28 59 43 95 √ - -
FJ20H 2289 25 28 59 43 95 √ - -
FJ20H 2290 25 28 59 43 95 √ - -
INSPECTION RESULTS
The dimensional examination (s) have been satisfactorily completed in accordance with standard reference used and customer requirement, Dimensional check were done
based on above reference standard
Conclusion :
Based on document evaluation and field inspection PT LD Servis concluded that the lifting equipment can be used according to codes and standards and we recommend the
lifting equipment to be used for operations with working load limit as stated above.
NDE Before Load Test on : N/A NDE After Load Test on : N/A
INSPECTION RESULTS
No apparent discontinuities defect were detected through Magnetic Particle Inspection in welds of lifting points was performed
No permanent defect or damage issue was detected at the time of process - The unit FIT for its intended use