S-23

PUSH BUTTON TOKEN


LESS BLOCK
INSTRUMENT FOR
SINGLE LINE

SUBJECT IRISET- SECUNDERABAD 1


•LSS: The fixed stop signal of a station controlling the entry of
trains into the next block section
•Station: Station means any place on a line of railway at which
traffic is dealt with or at which an authority to proceed is given
under the system of working
Introduction

• Due to various steps involved in extracting


Token, handing over of token to Loco Pilot,
handing over of token to Station Master (SM)
at Receiving station and sometimes token
loss causes train delay. In this context, Token
less block working is introduced in Indian
Railways

8/27/2020 DAIDO AND PTJ BLOCK INSTRUMENTS VER 1.0


PUSH BUTTON TOKEN LESS BLOCK
INSTRUMENT

5/4/2020 S-23 Tokenless block instrumets VER 1.0


Features of Push ButtonBlock
Instrument
(1)Push Button Type Operation. Sending SM will
take Line Clear on the Instrument. Non co-
operation feature.
(2) No drain feature when there is no operation.
(3) Automatic TOL Code transmission.
(4)Receiving SM will close the Block Section after
ensuring complete arrival of Train by checking LV
Board.
(5)Co-operation is required during Line Clear
Cancellation.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


Features(cont..)

• (6) Cooperation is required during Push


Back Operation.
• (7) DC Pulse Code Transmission is
employed for setting the pair of Block
Instruments to the required condition
according to Safety Rules of Absolute
Block Working.
• (8) This is used in Non-RE Area only.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


Features (cont..)

• (9) Works on 24Volts DC and 60 milli


Amperes.
• (10) It consistsof Operating Panel and
Relay Cabinet.
• (11) Magnetic Latched Relays are used for
registering operations.
• (12) Biased Relays are used for
Code Transmission on the Line Circuit.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


DC PULSE CODE

TCF Code For setting the instrument to TCF - + -

TGT Code For setting the instrument to TGT - - +

TOL Code For setting the instrument to TOL - - -

Line For setting the instrument


Closed to Normal - + +
Code
Bell code To send the bell code signals +
RELAYS OF PUSH BUTTON TOKEN
LESS BLOCK INSTRUMENT

5/4/2020 S-23 Tokenless block instrumets VER 1.0


The instrument consists essentially of two parts.

1) A relay cabinet housing all relays, and


2) A dash board called Block Panel containing
push buttons, indicators, bell, telephone, etc.

These two are manufactured as a compact unit with


the control panel coming on top of the relay cabinet.
The overall height renders the indicators to be at
the eye level and the buttons within comfortable
reach of a man of normal height.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
RELAY CABINET

• Height is 141 cm. The base measures 56


cm x 31 cm
• The panel and 36 number of relays and
four resistance & condenser units are on
the front side, while the button contacts
and jack board terminals of the relays are
on the rear side
• Floor mounting is adopted for fitting the
instruments
5/4/2020 S-23 Tokenless block instrumets VER 1.0
RELAY CABINET(cont..)

• ARA (American Rail Associates) terminals are 50 in


numbers are housed below the relays to take on
external connections including sources of power line
etc.
• Necessary contacts and coil terminals of relays are
brought out to these terminals. Cables for batteries,
line and external circuits are brought to the terminals
from the opening at the bottom on the instrument.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


RELAY CABINET(cont..)

• Wiring is done as per a color code for easy


identification.

• The user has to provide EKT instruments for shunt


key and slip/catch siding control key where required
as these areWIRE
not COLOUR CODEby the Manufacturers.
supplied
BLACK LOCAL
RED INST +ve
BLUE INST -ve
YELLOW LINE
WHITE SIGNAL

5/4/2020 S-23 Tokenless block instrumets VER 1.0


BLOCK PANEL

5/4/2020 S-23 Tokenless block instrumets VER 1.0


Bell Push Button
• Bell Push Button: Colour - Black,
Code - BCB. This is the most often
used button. This is used to call
the other SM's attention and for
exchange of bell code. For
cancellation operation, and for
transmitting a TCF or Line
Closed Code, this button has to
be pressed along with the
relevant button.
DAIDO AND PTJ BLOCK
8/27/2020
INSTRUMENTS VER 1.0
TGT Button
• TGT Button: Colour - Green,
Code
- TGB. This button is pushed
along with BCB for setting the
instrument to TGT. This button is
also pressed to interrupt the TOL
transmission to facilitate the train
sending operator to exchange
bell code of signals and contact
other station on phone which is
otherwise not possibleduring the
Transmission of TOL code.
8/27/2020 DAIDO AND PTJ BLOCK INSTRUMENTS VER 1.0
Cancel Button
• Cancel Button: Colour -
Red, Code - Cancel. To
be pushed along with
BCB for cancelling a Line
Clear. The action
advances the number in
the counter by one.

DAIDO AND PTJ BLOCK


8/27/2020
INSTRUMENTS VER 1.0
Line Closed Button

• Line Closed Button:


Colour - White, Code -
LCB. To be pushed along
with BCB for setting the
instrument to Line Closed.

DAIDO AND PTJ BLOCK


8/27/2020
INSTRUMENTS VER 1.0
Shunting Key Button
• Shunting Key Button: Colour -
Blue, Code - SHK. To be pressed
when it is required to remove the
key from the shunting EKT
instrument which can be
extracted in line closed, TGT-TOL

• Shunt key cannot be extracted


from EKT in TCF condition and
also only with TGT condition.

8/27/2020 DAIDO AND PTJ BLOCK INSTRUMENTS VER 1.0


Slip/Catch Siding Key Button

• Slip/Catch Siding Key


Button: Colour - Blue, Code
- SCK. To be pressed to
extract the key from EKT
instrument. The key is used
to operate Slip/Catch siding
points.

DAIDO AND PTJ BLOCK


8/27/2020
INSTRUMENTS VER 1.0
Train Coming From Indication

• TCF (Green): when lit,


indicates that the TCF
instrument is in
condition.

DAIDO AND PTJ BLOCK


8/27/2020
INSTRUMENTS VER 1.0
Line Close indication

• Line Closed
(White): when lit,
indicates that the
section has been
closed.

DAIDO AND PTJ BLOCK


8/27/2020
INSTRUMENTS VER 1.0
TGT and SNR Indications

• TGT (Green): when lit,


indicates that the
instrument is in TGT
condition.
• SNR (Green): This is
an indication to the
SM to verify if all the
relevant controls etc.
are normal.

8/27/2020 DAIDO AND PTJ BLOCK INSTRUMENTS VER 1.0


TOL and FREE
• FREE
Indications
Indication (Green):
Indicates that the prescribed
time interval has lapsed and the
cancellation of Line Clear can
commence, when the train has
not left the station and Line
Clear has to be cancelled.
• TOL (Red): When lit, indicates
that the train has entered into
the Block Section on 'Line
Clear'. Remains lit till the
section is closed. VER 1.0
COUNTER

• Counter: This registers the number of times


cancellation of Line Clear has been initiated
on the instrument. When the cancel and
BCB buttons are pressed, the counter
number jumps by one digit. The new
number is required to be lodged and
explained by the Operator.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


SINGLE STROKE BELL

Single stroke bell: This bell operates every


time when bell code is received to call the
attention of the SM as per the bell code of
signals.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


BUZZER

• Buzzer: This sounds intermittently at the


receiving station when TOL code is received
and continuously when the train arrives at
the station.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


TELEPHONE

Telephone: This is provided on the left side


of the instrument. A push button on it has
to be pressed while speaking. This is
electrically isolated from both local and line
circuits.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


RELAY TYPE
Total
S.No. Type Description Contacts Relays

Neutral Line
1 QN1 8F-8B 28
Relay
2 QL1 Latch relays 8F-6B 4
3 QB3 Biased relays 4F-2B 3
Electronic
4 ET -- 1
Timer
Condenser units with Q relay base (U-I,
5 4
U-II, U-III & U-IV)

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
POWER SUPPLY DETAILS

Telephone
1. 3 V Battery
Circuit
24 V Battery with each battery 2 V 120 AH
cells 13 nos. are preferable as minimum 24
Local Circuit V on load is
2.
required for its reliable working.

Battery to supply minimum of 60


3. Line circuit mA Line current.

External
4. 24 V battery
circuit

5/4/2020 S-23 Tokenless block instrumets VER 1.0


CRR: Code Receiving Relay
CTR: Code transmitting Relay
TOLAR: Train on line
acknowledgement relay
TOLTR: Train on line transmitting
Relay
TCKR: Transmission of coding
checking Relay
RCKR: Reception code checking
Relay
RDR: Reception Delivery Relay
PCR : Pole changing Relay
P2R : Second Positive Pulse
Registering Relay
ASCR: Advance starter control
relay
SHKR: Shunt key checking Relay
RELAY ENERGISED FROM
BATTERY
EXTERNAL
• SNR : Signal Normal Relay
• ASTR : Advanced Starter Track Relay
• TAR : Train arrival Relay

5/4/2020 S-23 Tokenless block instrumets VER 1.0


SNR: SINAL NORMAL RELAY

This relay proves the normal position of all the


signals and their knobs concerned. It picks up by
pressing BCB along with TGB/LCB or automatically
on receipt of all 2nd functional pulse except on TOL
code and drops at the end of 3rd pulse. However, if
the Instrument is set to TGT, it drops only on
releasing LSS control.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


SNR: SINAL NORMAL RELAY

Picking up of this relay indirectly proves that shunt


key and slip/catch siding keys are IN Position. Pick
up condition of FVT & LVT etc. are also proved in this
relay circuit. For all functions except TOL and Bell
transmission this relay working is a must. Though
feed to this relay from the external circuit is available,
it does not pick up due to ‘No drain circuit’ feature.
However, SNR indication is available.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


SCKR AND SNR CIRCUITS
EKT
36 SNR SHKR
SCKR
SCKR

SCKR CIRCUIT

SCKR relay picks up by proving front contact of SHKR and EKT


key is in.

17 SCKR 43

SNR
ASR

SNR K
2. 2 K 

SNR CIRCUIT
SNR relay picks up by proving SCKR front contact and other
conditions
5/4/2020 S-23 Tokenless block instrumets VER 1.0
ASTR: ADVANCE STARTER TRACK
RELAY

•It is a repeater for the FVT relay and can pick up


whenever the TGB is pressed and sticks once TGT
is established. It drops once FVT is actuated.
Dropping of this relay in TGT position initiates
transmission of automatic TOL code along with
TOL indication. It also picks up and sticks while
initiating push back cancellation. Non energization
of this relay will not permit the Instrument to change
to TGT even on receipt of Answer back TGT code.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


ASTR CIRCUIT

FVTPR 19 TGTR ASTR ASR ASR 45

R ASTR
CANCEL CAR ASTR
P

TGBR ASCR

ASTR CIRCUIT

ASTR : It is a repeater for the FVT relay and can pick up whenever the
TGB is pressed and sticks once TGT is established. It drops once FVT is
actuated.

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
TAR: TRAIN ARRIVAL RELAY

•It is a magnetic latch relay and used for


registering the arrival of a train on line clear.
It picks up through the external battery
while receiving a train on signals with
Instrument in TCF-TOL/TGT-TOL condition
and de latches to normal through local
battery once the instrument assumes to line
closed position.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
TAR CIRCUIT

TAR
CIRCUIT

TAR:It is a magnetic latch relay and used for registering the arrival
of a train on line clear. It picks up through the external battery while
receiving a train on signals with Instrument in TCF-TOL/TGT-TOL
condition and de latches to normal through local battery once the
instrument assumes to lineS-23 closed position.
Tokenless block instrumets
5/4/2020
VER 1.0
RELAYS ENERGIZED FROM
LINE BATTERY

• Relays energized from Line Battery


• CRR - Code Receiving Relay.
• Type QB3 as CRR(N) & CRR (R)
• TCKR -Transmission of codechecking
relay. Type QB3

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
CRR(N): Positve code Receiving Relay

• This relay will pick up at code receiving staton


only

• This relay is fed with other station line battery.

• This picks up of this relay picks up LR during


reception of code

• This relay picks up Whenever L1 is +ve and L2 is –ve

• Picking up of this relay alone completes bell


circuit.
CRR(R): Negative code Receiving Relay

• This relay will pick up at code receiving staton


only

• This relay is fed with other station line battery.

• This picks up of this relay picks up LR during


reception of code

• This relay picks up Whenever L1 is -ve and L2 is +ve


TCKR: Transmission of code
checking relay
This relay picks up at Transmitting end only.

This relay picks up during transmission of functional codes only.

This relay picks up with the line battery of Transmitting end in


series with either CRR(N) or CRR(R)

Since each functional code consists of 3 pulses, this relay picks up


3 times of transmitting of a functional code

Whenever this relay picks up either +ve or _ve pulse will be on line

Picking up of this relay ensures code prog. At the transmitting end

Picking up of TCKR will pick up LR and dropping of TCKR drops LR


TCKR AND CRR LINE CIRCUIT
TOLTR

CTPR TGBR CRR(R) CRR(R)


CRR(N)
R1 R2 NTR PTR CTR 7 7 CTR RCKR CTPR BCBR CRR(N) CRR(N)
TCKR CRR(R)
L2
LPR

1 +
LCBR
PTR NTR

4 -
TOLTR

CTPR TGBR

CTPR BCBR

LPR

NTR CTR 6 6 CTR RCKR LCBR TCKR AND CRR are


PTR L1 line relays which
picks up through line
TCKR & CRR LINE CIRCUIT battery

5/4/2020 S-23 Tokenless block instrumets VER 1.0


RELAYS ENERGISED FROM
LOCAL BATTERY

• RELAYS OTHER THAN LINE AND


EXTERNAL BATTERY SUPPLY.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


RCKR

RCKR - Code reception checking relay – This


senses the progress of the coding circuit at the
receiving end and when picked up, terminates
the pulse that is being received by opening the
line circuit. This relay prepares the instrument
for automatic answer back.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


RDR

•RDR - Receiving delivery relay – This stores


the first pulse of any code when it is
negative and remains energized till code
reception is complete and relay 3CR de-
energizes.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


CTR

CTR - Code Transmitting relay – This relay by


its state of energization or de-energization
decides whether the instrument is transmitting
or receiving respectively. Its front contacts
connect the line battery to line while its back
contacts connect CRR
(N) / CRR(R) to line.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


CTR

. There is a time delay circuit which checks


the duration of a pulse on line. If due to any
trouble at the receiving end, the coding circuit
functions irregularly, CTR de-energized,
resets all relays and re-initiates the code
afresh.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


CTR CIRCUIT
3CR LR 1CR TOLTR TGB TGTPR
P

TOLTR LCCPR TCFPR RCKR TGTPR

LCCPR TOLAR TCFPR CTR


SNR SHKR SCKR CANCEL
R P
SMK BCB TGB TCFR
T P P
N
SNR TOLTR TOLTR
LCB PCR PCR
P

CTPR N2R P2R R1 R2


CTR
CTR : is the code LR LPR CTR
transmission relay initially it 47 220f
picks up through SM key in UI
BCB and TGB buttons press TCKR 47 2200f CTR
. It has so many path UI

CTR
CIRCUIT

5/4/2020 S-23 Tokenless block instrumets VER 1.0


CTPR

CTPR - Repeater of CTR. This repeats the


CTR while the instrument is transmitting code,
but remains energized till the complete answer
back code is received. A time delay circuit
measures the time taken by the other
instrument to answer back. If the instrument
does not respond within a definite time, CTPR
releases and reset all relays and code
transmission is initiated all over again.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
LCCPR

LCCPR - Line Closed Code Reception Relay.


This picks up when Line Closed code is
received from line. When picked up this
enables the TGTR or TCFR to release and
switches on CTR for answer back when
necessary. This allows line closed code
transmission as an automatic reply code only
when the enquiry code is line closed code and
not otherwise.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
PTR AND NTR

PTR & NTR - Positive & Negative Transmitting Relay.

These relays switch on positive and negative pulse on


line by connecting the line battery to line appropriately.

Stick feed to these over TCKR front contact ensures


the presence of pulse on line till the line circuit is
opened.

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
PTR AND NTR

These relays are use respectively to connect on


positive/negative of dthe line battery line at the
transmitting instrument. Only one relay can pick up at
a time and this depends on the condition of the
coding relays 1CR, 2CR, 3CR and the Instrument
Position deciding relays TCFR and TGTR provided
the relay CTR is in energized conditions.

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
PTR AND NTR

Once TCKR is picked up the relay PTR/NTR sticks


through its front contact to ensure the presence of a
pulse on line till the line circuit is opened either by the
receiving instrument or by the transmitting instrument
itself by dropping of the relay CTR. The 2nd case takes
place only if the receiving Instrument fails to open the
line circuit at the end of a pulse.

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
NTR CIRCUIT

1CR 2CR 3CR RDR RCKR CTR


NTR
1CR 2CR 3CR TOLTR PCR TGTR TCFR PTR
N R NTR TCKR
TOLTR

2CR 3CR CTPR TOLTR LCCPR

TOLTR PCR TGTR TCFR TGBR

N N
NTR CIRCUIT

NTR : Negative transmission relay. when ever negative is connected to Line 1 this
relay is in pick up condition .initially it picks up with 1CR ,2CR and 3CR back
contact along with PTR back contact
5/4/2020 S-23 Tokenless block instrumets VER 1.0
LR

LR - Coding Relay. This is the relay that is


reacted on first by CRR(R) or TCKR while the
instrument is receiving or transmitting
respectively. By picking up and dropping
alternately as required it activates progresses
and terminates the functioning of the coding
circuit. So, the feeding circuits to this relay
consists of two branches, one with TCKR and
PTR/NTR contacts and the other CRR(R),
CRR(N) contacts.
5/4/2020 S-23 Token less block instruments VER 1.0
LPR

1) LPR- Repeater of LR. This repeats LR, but with


a difference. This sustains itself even during the
release period of LR by means of a time delay
circuit to monitor the duration of space period. If
the appearance of the next pulse on line or
closing of the line circuit after formation of pulse is
delayed due to irregular functioning of circuits,
LPR releases to reset all coding relays, even if the
code progress is halfway.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


LPR

2) This relay virtually by its state indicates the


activity or otherwise of the coding circuit. During
reception of an isolated positive pulse not as part
of a regular code, its back contact connects the
battery to the bell, while during reception of a
regular code its front contact connects it to LR.

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
1CR,2CR AND 3CR

• 1CR, 2CR & 3CR - Coding Relays. These relays


pick up and drop in a pre-determined manner to
progress coding. The energization or otherwise of
these mark the various stages of coding. As said
earlier, commencement of a pulse is decided by the
transmitting coding circuit and the termination by
the receiving coding circuit.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


1CR,2CR AND 3CR

• Among these relays 1CR is having two


branches circuits one with TCKR and other with
RDR respectively effective during transmission and
reception of code. Zener diode is provided across
the condenser of 3CR relay to have a constant time
delay irrespective of the voltage variation.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


TIMMING DIAGRAM FOR TCF CODE
ON AND OFF STATES OF 1CR, 2CR
AND 3CR

1CR 2CR 3CR


1st ON Up DN DN
1st OFF Up Up DN
2nd ON Up Up UP
2nd OFF Up DN UP
3rd ON DN DN UP
3rd OFF DN DN DN
Energized UP - -
De-energized DN - -
S-23 Tokenless block instrumets
5/4/2020
VER 1.0
P2R AND N2R

• P2R & N2R - Second positive and second


negative pulse receiving relays. These
store the polarity of the second pulse of a
code that is received. Front contacts of
these are used in the circuit of the final
relay.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


TOLTR
• TOLTR - TOL code transmitting relay. At the
sending station, this relay picks up when the
ASTR and ASR drop successively due to the
train occupying the FVT while entering the block
section. Consequently, CTR picks up to transmit
TOL code. At the receiving station, this picks up
in response to TOL code received from line.
The buzzer sounds intermittently, when the SM
acknowledges the TOL code by pressing BCB to
transmit a bell code, the TOLAR at the sending
station drops and causes TOLTR to drop to stop
the transmission of TOL Code.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
TOLAR

• TOLAR - TOL Acknowledgement Relay. In


the Token less system of working, a train
entering a block section on Line Clear
initiates its own protection arrangement.
This relay comes into play from the time
Line Clear is obtained till the receiving
station acknowledges the TOL code.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


TOLAR (cont..)

• At the sending station, this picks up


during reception of the second pulse of
TGT code and releases when receiving
SM transmits a positive pulse while
acknowledging TOL code. At the receiving
station, this picks up during reception of
second pulse of TCF code and releases
when the second pulse of the TOL code is
received.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
PCR

• PCR - Pole Changing Relay. All


operative codes begin with a negative
pulse. Positive and Negative pulses are
interchanged in TGT and TCF codes. To
reset these conditions, Line Closed code
with positive alone as second and third
pulse is employed. This relay generates
these pulses. It picks up at the end that
initiates Line Closed operation.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
PCR CIRCUIT

TAR

N PCR

TGTR TGTPR ASTR CAR ASR SNR R1 A1 R2 47 220f


R TIMER
U III
CANCEL BCBR ASR TAR CAR
P
R

PCR TAR TCFR


R R

PCR CIRCUIT

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
TGTR
1) TGTR - Train Going To Relay. Type - QL1. This
is a magnetic latch relay, latching its armature
in the operated position only. The relay has two
coils (i) Operating and (ii) Releasing. When the
operating coil is energized, the back contacts
break and front contacts make.

2) Once operated thus, the armature is latched in


that position. Thus, the front contacts are made
till the release coil is fed with current in the
appropriate direction.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
TGTR

3)The back contacts are designated as


‘Normal’ while the front contacts as
'Reverse'. This picks up on successful
reception of TGT code and releases when
Line Closed code is received. Its reverse
contacts are proved in the LSS control
circuits.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


TCFR

• TCFR - Train Coming From Relay -Type


- QL1. This is also a latch relay like TGTR.
It picks up when TCF code is received
and releases on reception of Line Closed
Code.
• TGTPR & TCFPR - Repeaters of
reverse conditions of TGTR & TCFR
respectively.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


TER

• TER - Time Element Relay. Before Line


Clear is cancelled when the train has not
left the station, a time interval of the order
of 2 minutes is required to elapse. To
achieve an Electronic Timer is used

5/4/2020 S-23 Tokenless block instrumets VER 1.0


CAR CIRCUIT

CAR & FREE INDICATION


CIRCUIT

CAR - Cancellation Relay. This picks up for cancellation


of Line Clear when the BCB and cancel buttons are
pressed along with some more conditions . This pushes
the counter by one digit.
S-23 Tokenless block instrumets
5/4/2020
VER 1.0
ASCR
ASCR -Advanced Starter Control Relay.

This relay proves that conditions for
dispatching a train on Line Clear are
fulfilled and that TOL condition can be
established subsequently when the train
passes the LSS. Also, it drops and locks
the signal when cancellation is initiated.
Front contacts of this are inserted in the
signal control circuits.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
SHKR

• SHKR - Shunt Key Checking Relay.


This relay can pick up only when the key
is in the transmitter and locked. Picking up
of this relay is a pre-requisite for activation
of CTR, TCFR and TGTR Relays

5/4/2020 S-23 Tokenless block instrumets VER 1.0


CONDENCER AND RESISTOR UNITS

• The condensers and resistors


required in the time delay circuits of
various relays are conveniently integrated
into a plug in base, which goes into a jack
board. Connections are made to the
terminals on the jack board. This type of
construction allows spares to be kept
ready for quick replacements at site in the
event of a failure without affecting train
services.
5/4/2020 S-23 Tokenless block instrumets VER 1.0
S-23
PUSH BUTTON BLOCK
INSTRUMENT
(operations)
PUSH BUTTON BLOCK INSTRUMENT

opp
LINE CIRCUIT
250
10W LCBR BCBR LPR CTPR RCKR CTR L1 CTR RCKR CTPR BCBR

+ Tele. BCBR R2 R1 CRR(R)


1 CRR(N)
Tele. BCBR CRR(R)
-
2
BCBR LPR CTPR RCKR CTR L2 CTR RCKR CTPR BCBR

Tele.
LINE CIRCUIT FOR BELL AND TELEPHONE 2f
Tele.

CRR(N) ; his relay picks up when + ve pulse is connected to L1 and – Ve


pulse is
connected to L2

5/4/2020 S-23 Tokenless block instrumets VER 1.0


OPERATION OF INSTRUMENT

1) To set the instrument to TGT condition push buttons BCB


(Bell Code Button) and TGB (Train Going to Button) are
pressed simultaneously at the train sending station.

2) This operation transmits the TCF code to the


instrument at the other end and if the conditions for
granting of ‘Line Clear’ are satisfied, sets the
instrument to TCF condition.

3) After the instrument at the receiving end is set to TCF,


TGT code is automatically generated and transmitted
back to set the instrument at the dispatching end to
TGT condition
Operational Sequence:
Call Attention:

Station A(Sending Station) Presses BCB


CRR(N) picks up at Station B (Receiving Station)

Station A Releases BCB


CRR(N) drops at Station B.

Station B Presses BCB


CRR(N) picks up at Station A.

Station B Releases BCB


CRR(N) drops at Station A..
Establishment of Line Clear for Sending a Train
from StationA to Station B.

Station A presses BCB & TGB

Station B Instrument is set to

TCF.
After setting to TCF, triggers TGT Code to
Station A.

The Instrument is set to TGT at Station


A. Station A releases BCB & TGB.
TIMMING DIAGRAM FOR TCF CODE
StationA TCF Code Transmission Station B

When both the Buttons


BCB & TGB are pressed
At Station A:

NTR
NTR
F/CF/C
PTR F/C
y
Supply
Suppl CRR( RD
Suppl
toto y to R) R
CRR(N)
CRR(R
CRR(
) R)
TOL
CRR( TCF
A
N) R
R
RCKR
TGT Code Transmission
StationA Station B

NNTTRRF/C
PTR F/C
F/C
Supply to
RD SSupp uppll
R CRR(N)
yyttoo
CCRR RR((
R)R)
TOL
A
R

TGT
R
TIMMING DIAGRAM FOR TGT CODE
LINE CLEAR CONDITION B/I RELAY
POSITION

STATION-A STATION-B

ASTR TOLAR
SNR TCFR
TCFPR
TOLAR
ASR
TGTR
TGTPR
StationA TOL Code Transmission Station B

When Train Enters Block Section

NTR
NTR F/C
F/C
Suppl RD
Suppl
y to R
y to
CRR(
CRR(
R)
R)
TO
L TCF
R
AR

TOL
T
R
TIMMING DIAGRAM FOR TOL CODE
Auto TOL code transmission.

Train Enters the Block Section.

Auto TOL Code is triggered from Station A and TOL


appears at both the Stations.

Station B gets TOL Indication and Buzzer.


Presses BCB. Buzzer stops.
BLOCK CLEARENCE PROCEDURE

Station B receives the Train on Signals and gets TAR


Buzzer. Normalises the Home Signal and stops the
Buzzer.
Checks LV Board.

Presses BCB & LCB.


Transmits LCC code to Station A.

Station A Instrument is set to Line Closed


Condition. Triggers LCC code to Station B.

The Instrument is set to Line Closed condition at


Station B.
Line Closed Code Transmission
StationA Station B

PTR
PNTTRRF/C
RD FF/CC
Supply
R SS
toupupplply
y to
CRR(N
)CCRR RR(
R)N)
P2
R

LCC
PR
TIMMING DIAGRAM FOR LC
CODE
S-23
PUSH BUTTON BLOCK
INSTRUMENT CIRCUITS

5/4/2020 S-23 Tokenless block instrumets VER 1.0


PUSH BUTTON AND BELL CIRCUITS

1) BY pressing TGT button TGTR picks up by pressing LCB button LCBR


picks up and
by pressing BCB button BCBR picks up.
2)5/4/2020
Through front contact of CRR(N) bell circuit complets
S-23 Tokenless block instrumets VER 1.0
LINE CIRCUIT
250
10W LCBR BCBR LPR CTPR RCKR CTR L1 CTR RCKR CTPR BCBR

+ Tele. BCBR R2 R1 CRR(R)


1 CRR(N)
Tele. BCBR CRR(R)
-
2
BCBR LPR CTPR RCKR CTR L2 CTR RCKR CTPR BCBR

Tele.
LINE CIRCUIT FOR BELL AND TELEPHONE 2f
Tele.

CRR(N) ; his relay picks up when – ve pulse is connected to L1 and – Ve


pulse is
connected to L2

5/4/2020 S-23 Tokenless block instrumets VER 1.0


SHKR CIRCUIT
EKT
SMK BCBR LCCPR CTPR LCBR
T R1 R2
SHKR
SHKR TGBR

TCFR CTR SHKR TGBR 47 1000f


R U II
LCCPR P2R

LCCPR RCKR

TOLAR TAR 13 H/S


R N R
SHKR CIRCUIT

SHKR: it will pick up through BCBR front contact along with LCBR
/TGBR front
contact, it Has five path
5/4/2020 S-23 Tokenless block instrumets VER 1.0
SCKR AND SNR CIRCUITS
EKT
36 SNR SHKR
SCKR
SCKR

SCKR CIRCUIT

SCKR relay picks up by proving front contact of SHKR and EKT


key is in.

17 SCKR 43

SNR
ASR

SNR K
2. 2 K 

SNR CIRCUIT
SNR relay picks up by proving SCKR front contact and other
conditions
5/4/2020 S-23 Tokenless block instrumets VER 1.0
CTR CIRCUIT
3CR LR 1CR TOLTR TGB TGTPR
P

TOLTR LCCPR TCFPR RCKR TGTPR

LCCPR TOLAR TCFPR CTR


SNR SHKR SCKR CANCEL
R P
SMK BCB TGB TCFR
T P P
N
SNR TOLTR TOLTR
LCB PCR PCR
P

CTPR N2R P2R R1 R2


CTR
CTR : is the code LR LPR CTR
transmission relay initially it 47 220f
picks up through SM key in UI
BCB and TGB buttons press TCKR 47 2200f CTR
. It has so many path UI

CTR CIRCUIT

5/4/2020 S-23 Tokenless block instrumets VER 1.0


NTR CIRCUIT

1CR 2CR 3CR RDR RCKR CTR


NTR
1CR 2CR 3CR TOLTR PCR TGTR TCFR PTR
N R NTR TCKR
TOLTR

2CR 3CR CTPR TOLTR LCCPR

TOLTR PCR TGTR TCFR TGBR

N N

NTR CIRCUIT

NTR : Negative transmission relay. when ever negative is connected to Line 1 this
relay is in pick up condition .initially it picks up with 1CR ,2CR and 3CR back contact
along with PTR back contact
TCKR AND CRR LINE CIRCUIT
TOLTR

CTPR TGBR CRR(R) CRR(R)


CRR(N)
R1 R2 NTR PTR CTR 7 7 CTR RCKR CTPR BCBR CRR(N) CRR(N)
TCKR CRR(R)
L2
LPR

1 +
LCBR
PTR NTR

4 -
TOLTR

CTPR TGBR

CTPR BCBR

LPR

NTR CTR 6 6 CTR RCKR LCBR TCKR AND CRR are


PTR L1 line relays which
picks up through line
TCKR & CRR LINE CIRCUIT battery

5/4/2020 S-23 Tokenless block instrumets VER 1.0


LR CIRCUIT
P2R

LCCPR CRR(R)

CRR(N) LPR RDR

LR PTR
LR
TCKR NTR 47 470f
U II
LR CIRCUIT

LR - Coding Relay. This is the relay that is reacted on first by CRR(R) or TCKR while
the instrument is receiving or transmitting respectively. By picking up and dropping
alternately as required it activates progresses and terminates the functioning of the
coding circuit. So, the feeding circuits to this relay consists of two branches, one
with TCKR and PTR/NTR contacts and the other CRR(R), CRR(N) contacts .
LPR CIRCUIT

5/4/2020 S-23 Tokenless block instrumets VER 1.0


1CR CIRCUIT

3CR 3CR TCKR NTR

LR 1CR

LPR 2CR 1CR RDR


1CR
470f
LR 47 

U
III
1CR is coding relay with the
combination of 2CR and 3CR
arrange dc pulse code NTR on
and off and PTR on and off 1CR CIRCUIT
conditions
S-23 Tokenless block instrumets
5/4/2020
VER 1.0
CTPR CIRCUIT

CTPR CIRCUIT

CTPR - Repeater of CTR. This repeats the CTR while the instrument is
transmitting code, but remains energized till the complete answer back
code is received. A time delay circuit measures the time taken by the other
instrument to answer back. If the instrument does not respond within a
definite time, CTPR releases and reset all relays and code transmission is
initiated all over again.
S-23 Tokenless block instrumets
5/4/2020
VER 1.0
RDR CIRCUIT
CAR TAR LPR R1 R2
N RDR

1CR CRR(R) CTPR

LR RDR

1CR LPR CTR

3CR RDR CIRCUIT

• RDR - Receiving delivery relay – This stores the first pulse of any code when it is
negative and remains energized till code reception is complete and relay 3CR de-
energizes.
S-23 Tokenless block instrumets
5/4/2020
VER 1.0
RCKR CIRCUIT

RCKR CIRCUIT

RCKR - Code reception checking relay – This senses the progress of the coding
circuit at the receiving end and when picked up, terminates the pulse that is being
received by opening the line circuit. This relay prepares the instrument for automatic
answer back.
S-23 Tokenless block instrumets
5/4/2020
VER 1.0
2CR CIRCUIT

LPR LR 2 CR R1 R2
2 CR

3CR LR 1CR 47  470  f

U II

2CR is coding relay with the 2CR CIRCUIT


combination of 1CR and 3CR
arrange dc pulse code NTR on
and off and PTR on and off
conditions
S-23 Tokenless block instrumets
5/4/2020
VER 1.0
3CR CIRCUIT

LPR 3CR R1 R2
3CR

LR 2CR 100 2200f

U III

3CR CIRCUIT

3CR is coding relay with the combination of 2CR and 3CR arrange dc pulse
code NTR on and off and PTR on and off conditions

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
TCFR CIRCUIT

1CR TCKR RDR 2CR CRR(R) P2R TGTR TCFPR R1 TAR TOLAR
R2 CAR TGTPR PCR
N TCFR N R
R3 R4
CRR(N) ASR LCCPR P2R LCBR BCBR TGTPR SNR

CANCEL SCKR SHKR SNR


P

TCFR CIRCUIT

TCFR : picks up at receiving end instrument this is latch relay . It picks up by


proving 1CR front ,RDR front contact, CRR(R) front contact ,p2R front contact
and TGTR (n) and some more conditions
5/4/2020 S-23 Token less block instruments VER 1.0
ASTR CIRCUIT

FVTPR 19 TGTR ASTR ASR ASR 45

R ASTR
CANCEL CAR ASTR
P

TGBR ASCR

ASTR CIRCUIT

ASTR : It is a repeater for the FVT relay and can pick up whenever the
TGB is pressed and sticks once TGT is established. It drops once FVT is
actuated.

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
PTR CIRCUIT

TCFR
R
PCR TGTR TCFR

N N
2CR 3CR CTPR TOLTR PCR LCCPR

PCR PTR TCKR

1CR 2CR 3CR TOLTR PCR TGTR TCFR NTR RDR RCKR CTR
N N PTR
PTR CIRCUIT

PTR – Positive Transmitting Relay. This relay switch on positive pulse on line by
connecting the line battery to line appropriately. Stick feed to these over TCKR front
contact ensures the presence of pulse on line till the line circuit is opened.

5/4/2020 S-23 Tokenless block instrumets VER 1.0


N2R AND P2R CIRCUIT

P2R/N2R CIRCUIT

• P2R & N2R - Second positive and second negative pulse receiving relays.
These store the polarity of the second pulse of a code that is received. Front
contacts of these are used in the circuit of the final relay.
S-23 Tokenless block instrumets
5/4/2020
VER 1.0
TOLAR CIRCUIT
P2R

TGTR TCFR N2R 2CR


R1 R2
N N TOLAR
3CR 1CR R3 R4

TCFR N2R 2CR TGTPR

LPR CRR(N) TCFPR CTPR TOLTR

TOLAR CIRCUIT

• TOLAR:-TOL Acknowledgement Relay. In the Token less system of working, a


train entering a block section on Line Clear initiates its own protection
arrangement. This relay comes into play from the time Line Clear is obtained
till the receiving station acknowledges the TOL code.

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
ASR AND LCCPR CIRCUITS

ASR CIRCUIT

1CR TCKR RDR 2CR CRR(N) 1CR P2R R1 R2 SHKR


LCCPR

LCCPR SHKR

LCCPR CIRCUIT

5/4/2020 S-23 Tokenless block instrumets VER 1.0


TGTR CIRCUIT
LC TG
1CR TCKR RDR 2CR CRR(N) ASR CPR TPR R1 R2 BCBR TGBR CTPR TCFR N2R CAR
TGTR N
TGTPR
R3 R4
ASR LCCPR P2R

PCR TGTPR BCBR LCB


R

CANCEL SCKR SHKR SNR PCR TGTPR TOLAR TAR


P
R N
TGTR CIRCUIT

TGTR - Train Going To Relay. Type - QL1. This is a magnetic latch


relay, latching its armature in the operated position only.
The relay has two coils (i) Operating and (ii) Releasing.
When the operating coil is energized, the back contacts break and
front contacts make.
ASCR AND TGTPR CIRCUITS
TGTR TGTPR ASTR CAR SNR ASR PCR TOLAR
R ASCR R

ASCR CIRCUIT

TCFR TGTR TGTR


R TCFPR R TGTPR R

TCFPR/TGTPR CIRCUIT

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
TOLTR CIRCUIT

1CR TCKR RDR 2CR CRR(R) P2R N2R 1CR TCFPR


TOLTR

TOLTR RCKR TGTR N2R RCKR 47 1000f


N U II

ASR TGTPR TOLAR CAR TCFPR

R
TOLTR CIRCUIT

• TOLTR - TOL code transmitting relay. At the sending station, this relay picks
up when the ASTR and ASR drop successively due to the train occupying
the FVT while entering the block section. Consequently, CTR picks up to
transmit TOL code. At the receiving station, this picks up in response to TOL
code received from line. The buzzer sounds intermittently, when the SM
acknowledges the TOL code by pressing BCB to transmit a bell code, the
TOLAR at the sending station drops and causes TOLTR to drop to stop the
transmission of TOL Code.S-23 Tokenless block instrumets
5/4/2020
VER 1.0
TAR CIRCUIT

TAR
CIRCUIT

:
•TAR It is a magnetic latch relay and used for registering the arrival of a train on
line clear. It picks up through the external battery while receiving a train on
signals with Instrument in TCF-TOL/TGT-TOL condition and de latches to
normal through local battery once the instrument assumes to line closed
position.
S-23 Tokenless block instrumets
5/4/2020
VER 1.0
PCR CIRCUIT

TAR

N PCR

TGTR TGTPR ASTR CAR ASR SNR R1 A1 R2 47 220f


R TIMER
U III
CANCEL BCBR ASR TAR CAR
P
R

PCR TAR TCFR


R R

PCR CIRCUIT

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
CAR CIRCUIT

CAR & FREE INDICATION


CIRCUIT

CAR - Cancellation Relay. This picks up for cancellation of Line Clear when
the BCB and cancel buttons are pressed along with some more conditions .
This pushes the counter by one digit.

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
INDICATION CIRCUIT

LR TCFPR TGTR LED 2.2K RDR

TCFPR LED 2.2K P LAMP


P
TCF(G)K

TGTR LED 2.2K P LAMP BCBR


P
R TGT(G)K

INDICATION CIRCUIT

INDICATION CIRCUIT gives various indications on the panel like line close
,TCF green and TGT green by proving the above conditions.

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
TOL(R)K
CIRCUIT
TGTR PCR ASR TGTPR 2.2K
R TOL(R)K

TCFPR

TOLAR TCFPR
N
TOL INDICATION CIRCUIT

INDICATION CIRCUIT TOL(R)k will lit when train enters the block section
by proving conditions TGTR latched and TGTPR front contact in one path
and other path is also available through TOLAR

S-23 Tokenless block instrumets


5/4/2020
VER 1.0
TIMMING DIAGRAM FOR TCF CODE
TIMMING DIAGRAM FOR TGT CODE
TIMMING DIAGRAM FOR TOL
CODE
TIMMING DIAGRAM FOR LC
CODE
BLOCK SIGNALLING-TLBI (FM & PB TYPES)

Feature FM Handle type Push button Instrument

Bell - -Ve on L1 +Ve on L1


TCF +Ve Carrier 85HZ - + -
TGT +Ve Carrier 65HZ - - +
TOL Carrier 65HZ - - -
Line closed +Ve Carrier 85HZ - + +
Shunt Key Is in-built and provided by the Shunt key is not in-built and
manufacturer not provided by the
manufacturer
TOL Indication Appears in sending and receiving Appears in sending and
instruments receiving instruments
BLOCK SIGNALLING-TLBI (FM & PB
TYPES)

Feature FM Handle type Push button Instrument

TOL Buzzer Sounds at both sending Sounds intermittently at the


and receiving receiving end only
instruments
Authority to proceed OFF aspect of LSS OFF aspect of LSS

Manufacturer S&T work shop Howrah S&T workshop Podanur


Shunt key can be In Line closed and TGT In Line closed and TGT- TOL
extracted position position
Shunt key when taken Locks the Block handle Makes the instrument
out mechanically inoperative electrically.
P.O.H Since having some Not required since it is
mechanical parts purely relay interlocking
overhauling is required
and it is 7 years.
BLOCK SIGNALLING-TLBI (FM & PB
TYPES)
Feature FM Handle type Push button Instrument

Operated By A block handle which is having three Pressing different Knobs


positions TCF, TGT & Line closed for different operations

Co operation Co operation is required for all Cooperation is eliminated


operations on the instrument for line clear and closing
the instrument hence full
advantage of Tokenless
block working obtained.

But Co-operation required


for Line clear cancellation
& Push back cancellation.
No drain circuit It is not there It is there
feature
Usage It can be used in AC RE as well as NON It cannot not be used in
RE Area AC RE Area
Maintenance Requires Maintenance Less Maintenance
S-
23
PUSH BUTTON BLOCK
INSTRUMEN
FAILURES AND TROUBLE
SHOOTING
PBBI SUSPENDED
CIRCUMSTENCES
The Push Button Token less Block Instruments shall
be considered to be interrupted and their working
suspended in the following circumstances

1) When attention cannot be obtained direct on the


Block Instrument.

2) When signalson the Bell are received indistinctly or fail


altogether.

3) If the LSS fails to return to ON position as a train


passes it.
4) If the TAR (Train Arrival) buzzer fails even after
the complete passage of the train inside the
FSS over the LVT Circuit ( May be due to
failure of the LVT circuit)

Note: Though FSS may go to ON automatically


by passage of the train, FSS shall not be put
back to Normal position unless the whole of
the train has arrived inside the FSS. Failure to
adhere to this will result in a Block Failure and
the TAR buzzer will not sound under such
circumstances.
5) When there is reason to believe that there is
contact between the Block line wire and any
other circuit:
Note :(i) If a contact exists between the Block
wire and any other circuit, there is a
possibility of irregular beats on the bell. A
contact between two block wires would cause
signals given on one instrument to be
repeated on the neighboring instrument.
• Not (ii) The Telephone connected with
e
instrument for
the train signalling, also shall be
considered as having failed and working by
means of the telephone would not be
resumed until authorized by the Signal
engineer or any other authorized person.
6) If the Instrument or its battery counter is found
unlocked or seal missing.
7) When TOL buzzer fails at the receiving
station, even after display of TOL indication
on the Block Instrument.
Note: (i) If a following train in the same
direction working on paper line clear ticket
actuates the TAR buzzer, block working may
be resumed.
Note: (ii) If there is no following train but there
is a train to proceed in the opposite direction
the same will be dispatched on paper line
clear ticket. The SM at other end should use
cancel push button as in the case of a train
pushing back and receive the train on
proper signals after which block working
may be resumed without waiting for S&T
staff.
8) When Material Train etc. is required to be
taken into a Block Section after Line Block
has been imposed in accordance with
Appendix V to the G & SR.

Note: Block Working with Line Clear


exchange by any means shall to suspended
and the Material train etc. started on an
‘Authority to proceed without Line Clear’.
After the Line Block has been removed the
SMs themselves shall resume block working.
9) When a train is required to enter a block section
which is obstructed by an accident or any other
reason.

Note: Block Working with Line Clear Exchange by any


means shall be suspended and trains started on an
‘authority to proceed without Line Clear’. On the
obstruction being removed, the SM themselves shall
resume block working.

10) If it is known that the Instrument is defective in any


way not specified above.
PBBI OTHER FAILURES
1) If the TGT indication is not displayed on the
instrument when operated or TOL indication is not
displayed on the Instrument after the train has entered
the Block Section.

2) If the LSS cannot be cleared even when the


instrument displays TGT indication.

3) If the LSS can be cleared without displaying TGT


indication on the Block Instrument.
Note: This test shall be made when SM take charge of
the Block Instrument and an entry made in the Train
Signal Register (TSR)
PBBI OTHER
FAILURES
4) Since the OFF aspect of the LSS is the
authority to enter the block section in the
Token-less territory, in case LSS does not
assume OFF aspect, the Block working
should be suspended.

5) When a train arrives at a station when the


Block Instrument is not displaying TOL
indication.
Note: In this case irregularities shall be
reported as an accident.
PBBI OTHER FAILURES

6) If the Line closed indication can be displayed


on the Instrument before complete arrival of the
train.

7)If the TGT indication cannot be cancelled


even though proper manipulation has
been done.

8)If the TGT indication can be cancelled without


the co-operation of the SM at the other end of
the Block Section
ALTERNATIVE MEANS OF
COMMUNICATION

In the event of failure or suspension of Block


Instruments Line Clear shall be obtained by
any one of the alternative means of
communications in the order of priority
indicated below:

a)Telephone attached to the Block


Instrument,
b)Station to Station fixed telephones
wherever available,
ALTERNATIVE MEANS OF
COMMUNICATION

c) Fixed telephone such as Railway auto


phones and BSNL telephones,
d) Control telephone and
e) VHF set.
Shall be worked in accordance with the
procedure laid down in G&SR 14.01
All failures shall be reported promptly to all
concerned.
TROUBLE SHOOTING CHART
FOR PUSH BUTTON BI
S.No Type of Observation Causes
Failures
1 Bell Code 1. Bell Beats failed Due to twist on line
Failed altogether both sides or
break fault CRR is not
picking up. CTR Back
contact in CRR circuit
not
making
1. Outgoing bell beats 1. Disconnection of Line
only failed Battery at sending
end.
2. Disconnection in
250 Ohms
resistance in Unit
No. IV at sending
end.
3. Disconnection of
Local
2. a) Generation of 1. SHKR not picking up Shunt Key IN contact
Code failed inside
EKT is not making
properly
2. SCKR not picking up Local Battery Weak

3. SNR not picking up 1. Disconnection in


Location
Battery
2.Disconnection in SNR
circuit. Due to Circuit
Controller contact not
making, FSS Lamp fused
etc.
4(a) CTR not picking up 1. Cancel Button
developed
High Resistance fault.
2. BCB/TGB contact
spring not making
while buttons are
pressed.
3. SNR –2A1
contact
4(b) CTR not holding 1. Condenser for the time lag
arrangement unit. – I
2. CTR stick circuit contacts of TCKR 5A6, LR
7B8, LPR 2D1 relays.

5. TAR not picking up on 1. Faulty circuit controller of Home Signal


arrival of train. lever/disconnection in other contacts of TAR
circuits (or) TOLAR- 5A6 offer high
resistance
2. LVT track circuit failed.
b) Code CTR actuating but Disconnection of Line or
Transmissi code is not Disconnection in Line Battery
on transmitted
Failed
c) Code reception failed CRR is not picking CRR not energizing due to
while code is being BCBR- 6A5/6B5 not making at
received from the receiving end.
other end.
d) Code Transmission CTPR picking up & Condenser across CTR in Unit
not dropping 1st pulse No. 1
progressing only being punctured.
transmitted
e) Failure to generate RCKR not holding RCKR picked up at receiving
TGT hence CTR not station
automatic reply code picking up. but not holding due to
or answer back code condenser
in response to fault in Unit I.
incoming
TCF code
3.a) Answer back Instrument is not 1. ASR- 2CI front contact in
code is set to TGT even TGTR circuit is not
recd., but TGTR is though TGT code making.
not picking up is 2. In Unit IV 50 ohm
received resistance developed
open circuit. Fault 220
mfd condenser
punctured resulting in
ASR not holding.
3. CTPR not holding
due to 4700 mfd
condenser
defective, in Unit
No.1
4. ASTR not picking up due
to
failure of FVT.
b) While taking TCFR not picking Disconnection in TCFR coils
line up at receiving resulting in failure of replay
4. a) Both TCF & TOL TOLAR not Local Battery at the
Indications holding at receiving
appeared at receiving end end is defective or
receiving end momentarily interrupted
simultaneously (some time due to
while the other development of
station is trying reverse
to polarity in one of the
take line clear cells).

5. When TGB & TCKR contact No. TCKR Defective


BCB 4 A3 offered high
are pressed, TOL resistance.
code is transmitted Hence, LR and
instead of TCF LPR did not pick
Code. up. Hence, 3 CR
did not pickup
6. In reply to the During the code TCKR defective.
incoming progress TCKR
TCF code, TOL code contact No. 4A3 is
is transmitted as not making.
‘Answer Back’ Hence, LR is not
instead of TGT picking up. 3CR is
code. not picking up.
Consequently
NTR is not
dropping while
the instrument is
‘Answering Back’
7. Transmission of reply CTR is not holding Solder given up
code is incomplete CTR
2CI is not available
as the solder is
given up
8. Failure of transmission CTR was not picking Wire given up
of code. up and holding. LPR
was not holding
9. No Answerback This was due to Relay contact not making.
for LCCPR not
Line Closed Code holding in the
Line closed
code receiving
instrument due
to the IA2
contact of
SHKR was
offering
high resistance.
10. While taking line TOLAR not holding TOLAR latch is not effective
clear TOL indication at sending end
appeared
immediately
after
getting
TGT
indication at the
train sending end
11. TOL indication TOL indication Failure of FVT after the
appeared before appeared instrument is set to TGT
the entry of train prematurel before the train passed over
into y FVT
the Block Section

12. TOL indication No TOLK Check the LED of 2.2 K ohm


failed resistance

13. TOL Buzzer failure Buzzer is not TOLTR not picking up at


sounding receiving
station.

14. Train arrival buzzer -do- TAR not picked up (or) not
failure holding.
Do,s
Operating department:
(1) Ensure SM’s key/ SHK /SCK “IN” for
taking Line Clear.
(2)Block competency Authorized person only
shall operate Block Instrument.

Signal and Telecom department:


(1)Megger Block line wires jointly with
SSE/JE (Telecom) once in a year.
(2) Maintain the Line, Local and Location
Batteries in good condition.
(3) Ensure Incoming/Outgoing Line current 60
– 70
(4) All Relays shall be plugged correctly
according to code pins.
(5) Retaining clips shall be properly fixed.
(6) Ensure Double Locking of Block Instruments.
(7) Ensure proper sealing of Block Instruments.
DONT’S

Operating department:
(1)Do not allow unauthorized person
to operate the Block Instrument.
(2)Do not allow to interfere with the Block
Instrument without proper
disconnection.

(3)Never allow testing of the Block


Instrument by S & T staff with train in
the Block section.
DONT’S

Signal and Telecom department:


(1) Local Voltage shall not be more than 28.8 V D.C.
(2) Do not certify the Block Instrument after
attending Block failure without testing and
issuing of Reconnection notice.