Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Truma CP plus

Digital Control Panel

If the information in these instructions is not


followed exactly, a fire or explosion may result, Operating instructions Page 2
causing property damage, personal injury, or Installation instructions Page 14
death. To be kept in the vehicle.
This document is part of the product.
Do not store or use gasoline or other
flammable vapors and liquids in the vicin-
ity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Evacuate all persons from the vehicle.


• Shut off the gas supply at the gas contain-
er or source.
• Do not touch any electrical switch, or use
any phone or radio in the vehicle.
• Do not start the vehicle’s engine or electric
generator.
• Contact the nearest gas supplier or certi-
fied service technician for repairs.
• If you cannot reach a gas supplier or certi-
fied service technician, contact the nearest
fire department.
• Do not turn on the gas supply until the gas
leak(s) has been repaired.

Installation and service must be performed by


a certified service technician, service agency,
or the gas supplier.
Table of Contents Intended use
Intended use ........................................................................... 2 The CP plus control panel is suitable only for
installation in RVs used for recreation, travel, or
Consumer Safety Information camping.

Safety definitions ....................................................................... 2 The CP plus control panel controls and monitors
Safety behavior and practices ................................................... 2 a Truma Combi™ furnace with additional
indirect water heating.
Operating Instructions
Available models:
Display and operating elements .......................................... 3
Description ................................................................................ 3 • Truma Combi™ eco
Rotary push button .................................................................... 3 • Truma Combi™ eco plus
Back button ............................................................................... 3 • Truma Combi™ comfort
Instructions for use .................................................................... 3 • Truma Combi™ comfort plus
Initial start-up .......................................................................... 4
Start-up .................................................................................... 4
Control panel on/off ................................................................... 4 Consumer Safety Information
Select setting level .................................................................... 4
Functions ................................................................................. 4
Change room temperature ........................................................ 5
Change hot water level .............................................................. 5 Safety definitions
Select energy mode .................................................................. 6
Select fan speed ........................................................................ 7 This is the safety alert symbol. This symbol
Set the time switch ................................................................... 7 alerts you to potential hazards that can kill or
Set clock .................................................................................... 9 hurt you and others.
Settings ..................................................................................... 9
Display power supply 120 VAC ............................................... 10 indicates a hazardous situation
Warning ................................................................................. 11 which, if not avoided, could result in death or
Malfunction ........................................................................... 11 serious injury.
Maintenance ......................................................................... 11
Technical data ....................................................................... 12 is used to address practices not re-
Troubleshooting chart (Truma Combi furnace) ............... 13 lated to physical injury.

Installation Instructions
Other important information or tips.
Safety information ................................................................... 14
Description .............................................................................. 14
Dimensions .............................................................................. 14 Safety behavior and practices
Installation location ................................................................. 14
Wiring diagram ........................................................................ 15
Connection .............................................................................. 15
Installation ............................................................................... 15 • Use the CP plus control panel only when it
is in a technically sound condition.

• Have a specialist immediately remedy any


malfunctions. Remedy the malfunction
yourself only if a remedy is specified in the
troubleshooting chart in these operating
instructions.

California Proposition 65 lists chemical sub- • Have a defective CP plus control panel re-
stances known to the state to cause cancer, paired only by the manufacturer or its ser-
birth defects, death, serious illness or other vice department.
reproductive harm. This product may contain
such substances. • Any alteration to the appliance or its con-
trols can be dangerous and will void the
warranty.
2
Operating Instructions

Display and operating elements Rotary push button


The rotary push button (8) is used to select and
change setpoints and parameters; it is then
1 tapped to save the values. Selected menu items
hot
flash.
eco 2

3
+ Turn clockwise
6
• The menu is scrolled through
5 from left to right
• Increase values (+)
7 4
- Turn counterclockwise
• The menu is scrolled through
from right to left
9 8
• Reduce values (-)

Tap
• Save a selected value
Fig. 1 • Select a menu item, go to the
setting level
1 Display
2 Status line Press (3 seconds)
3 Menu line (top) • Main switching function – con-
4 Menu line (bottom) 3 sec trol panel on/off
5 Power supply display
120 VAC (mains supply)
6 Time switch display
7 Settings/values Back button
8 Rotary push button
9 Back button Press the Back button (9) to go back to a previ-
ous menu and cancel settings. This means that
the previous values remain unchanged.
Description
• A rotary push button (8) is used to select Instructions for use
menu items in the menu lines (3 + 4) and to
adjust settings. • If there is an interruption to the power sup-
ply, the clock has to be reset.
• Information is shown on a backlit display (1).
• If a new furnace is connected to the bus sys-
• The Back button (9) is used to go back to a tem of the control panel, repeat the proce-
previous menu. dure described in “Initial start-up”.

3
Initial start-up Control panel on/off
Perform the following steps for initial start-up: • Press the rotary push button (8) for more
than 3 seconds.
• Switch on the 12 VDC power supply of the
control panel and the furnace. With Truma
Combi eco plus and Truma Combi comfort • Previously set values and operating
plus, also switch on the 120 VAC power sup- parameters are active again when the
ply (mains supply). panel is switched on.

• Start searching for the furnace in menu item • When you switch off the control
“Settings” –> “RESET” –> “PR SET”. panel, any Truma Combi device that
is connected is also switched off
When you have confirmed the selection, the automatically.
control panel is initialized. During this process,
“INIT ..” is shown on the display. The recognized • Because of internal time lags for the
furnace is recorded in the control panel. heating, the switching-off process can
take a few minutes.

Start-up
Start/Stand-by screen Select setting level
When the control panel is connected to the • Tap the rotary push button (8).
power supply, after a few seconds a start screen
is displayed. The display shows the setting level. The first
icon flashes.

• After repairs or upgrades, the procedure


described in “Initial start-up” has to be
repeated. Functions
• The first time you switch on the con- The functions of menu lines (3, 4) of the CP plus
trol panel, any Truma Combi device control panel can be selected in any sequence.
that is connected is not switched on The operating parameters are shown in the sta-
automatically. tus line or in the displays (5, 6).

4
Change room temperature Change hot water level

• Use the rotary push button (8) to select the • Use the rotary push button (8) to select the
icon in the menu line (3). icon in the menu line (3).

• Tap the button to go to the setting level. • Tap the button to go to the setting level.

• Select the desired temperature with the • Select the desired hot water level with the
­rotary push button (8). rotary push button (8).

• Tap the rotary push button (8) to confirm the • Tap the rotary push button (8) to confirm the
value. value.
a a b c d
boost boost boost boost
hot hot hot hot
eco eco eco eco

2 2
3 3

Adjustable temperature range: a = Boiler* – Hot water generator is on.


b = eco** – Water temperature 104 °F (40 °C)
Temperature display Range Increments c = hot – Water temperature 140 °F (60 °C)
d = boost* – Boiler content is heated quickly
Fahrenheit 40 – 86 °F 1 °F (boiler priority) for up to 40 min-
Celsius 5 – 30 °C 1 °C utes. The water temperature is
then kept at the higher level (about
144 °F (62 °C)) for two subsequent
a = Furnace* is switched on. heating cycles. When the water
temperature is reached, the room
* This icon flashes until the desired room tem- is heated again.
perature is reached.
* This icon flashes until the desired water tem-
The temperature can be changed quickly perature is reached.
using the rotary push button (8) (on the
stand-by screen). ** The water temperature 104 °F (40 °C) can be
kept in “Heating and hot water mode” for a
limited time only (heating priority).

5
Special features in mixed mode
Select energy mode • Interruption in the 120 VAC power supply:

• Use the rotary push button (8) to select the The furnace automatically switches to gas
icon in the menu line (3). mode. When the 120 VAC power supply is
restored, the furnace automatically switches
• Tap the button to go to the setting level. back to mixed mode.

• Select the desired energy mode with the • Fault in combustion process (e.g. fuel
­rotary push button (8). shortage):

• Tap the rotary push button (8) to confirm the The furnace automatically switches to elec-
value. tric mode. If the furnace is to run in mixed
mode again, the cause of the malfunction
a b c d e must be remedied and the furnace has to
be started again by going to the menu item
“Malfunction” and pressing the rotary push
button. See “Malfunction” on page 11.

Special features in electricity mode


2 • When the 120 VAC power supply is inter-
rupted and the 12 VDC supply is on, an error
3 code is displayed on the control panel.

• When the 120 VAC power supply is recon-


Icon Operating Energy mode nected, the furnace will restart automatically
mode with the previous settings without any user
a LP gas LP gas interaction. The error code on the control
b MIX 1 * Electricity 850 W+ Gas panel will disappear.
c MIX 2 * Electricity 1700 W+ Gas
d EL 1 * Electricity 850 W
e EL 2 * Electricity 1700 W

* Mixed mode and electricity mode


Possible only with Truma Combi eco plus
and Truma Combi comfort plus furnaces
with electric heating elements.

When the furnace is switched on (room tem-


perature, hot water level active), the energy
mode selected in the previous heating pro-
cess is shown in the status line. The factory
setting is gas.

6
Select fan speed Set the time switch

• Use the rotary push button (8) to select the


icon in the menu line (3).
Risk of carbon monoxide poisoning
• Tap the button to go to the setting level.
The enabled time switch turns the furnace
• Select the desired fan speed with the rotary on, even when the recreational vehicle (RV) is
push button (8). parked. The exhaust gas from the furnace can
cause poisoning in enclosed spaces (e.g. ga-
• Confirm with the rotary push button (8). rages, repair shops).

a b c d If you park the RV in an enclosed space:

• Shut off the gas feed to the furnace.

• Disable the time switch (OFF).

2 • Switch the furnace off. (On the ­Truma


CP plus control panel, press the rotary
3 push button (8) for 3 seconds.)

Icon Oper- Description • The time switch can be selected only if


ating the clock was set on the control panel.
mode • If the time switch is ON, the “Disable
– OFF Fan is switched off. time switch (OFF)” menu is displayed.
(Can be selected only if
furnace is switched off) • Use the rotary push button (8) to select the
a VENT* Circulating air, if fur- icon in the menu line (4).
nace is switched off.
Speed can be selected in • Tap the button to go to the setting level.
10 increments.
b ECO Low fan speed Enter the start time
c HIGH ** High fan speed • Use the rotary push button (8) to set the
d BOOST Fast room heating hours and then the minutes.
Available if the difference
between the selected and 24 h mode 12 h mode
the current room temper-
ature is > 18 °F (10 °C). hot hot

* Can increase wear and tear on the motor,


depending on how often it is used.

** HIGH fan speed uses more electricity, is


louder, and increases wear and tear on the = a. m.
motor. = p. m.

When the furnace is switched on (room


temperature, hot water level set), the fan
speed selected in the previous heating pro-
cess is shown in the status line (2). The fac-
tory setting is ECO.

7
Enter the end time Select energy mode
• Use the rotary push button (8) to set the • Select the desired energy mode with the ro-
hours and then the minutes. tary push button (8).

24 h mode 12 h mode • Tap the rotary push button (8) to confirm the
value.
hot hot

hot

= a. m.
= p. m.
The “Select energy mode” menu is dis-
If the start/end time is later than the time played only if a furnace with electric heat-
when you entered the settings, the operat- ing elements is connected
ing parameters are not active until the next (Truma Combi eco plus or
start/end time is reached. Until then, the Truma Combi comfort plus).
operating parameters set outside the time
switch remain valid. Select fan speed
• Select the desired fan speed with the rotary
Set the room temperature push button (8).
• Select the desired room temperature with
the rotary push button (8). • Tap the rotary push button (8) to confirm the
value.
• Tap the rotary push button (8) to confirm the
value. hot

hot

The “Select fan speed” menu is displayed


only if the room temperature was set.

Example: Temperature display in °F Enable the time switch (ON)


• Enable the time switch (ON) with the rotary
Set the hot water level push button (8)
• Select the desired hot water level with the
rotary push button (8). • Tap the rotary push button (8) to confirm the
value.
• Tap the rotary push button (8) to confirm the
value. hot 2

hot

The time switch remains enabled, even for


several days, until it is disabled (OFF). If the
time switch is programmed and enabled,
the time switch icon is shown in the status
line (2). If the time switch is active, the icon
flashes.

8
Disable the time switch (OFF)
• Tap the rotary push button to go to the set- Settings
ting level.

• Disable the time switch (OFF) with the rotary • Use the rotary push button (8) to select the
push button (8) “Settings” icon in the menu line (4).

• Tap the rotary push button (8) to confirm the • Tap the button to go to the setting level.
value.
1. Show version number of connected
devices
hot Display the version number of furnace and
control panel.

hot

Set clock
2. Backlighting
Change the backlighting of the CP plus control
Display 24 h mode Display 12 h mode panel in 10 increments.
hot hot hot

4 4
= a. m.
= p. m. 3. Language
Select the desired language (English, German,
• Use the rotary push button (8) to select the French, Italian).
“Set clock” icon in the menu line (4).
hot

The hour display flashes.

• Use the rotary push button (8) to set the


hour.

• Tap the rotary push button (8) again and the


minute display flashes. 4. 12 h / 24 h Mode
Display in 12 h (a. m., p. m.) / 24 h mode.
• Use the rotary push button (8) to set the
minutes. hot

• Tap the rotary push button (8) to confirm the


value.

Default 12 h mode.

9
5. °C / °F temperature display 7. Factory setting (RESET)
Select temperature display °C (Celsius) or The reset function resets the control panel to
°F (Fahrenheit). the factory settings. All your settings are de-
leted. Newly connected devices are recognized
hot and recorded in the control panel.

• Switch on the 12 VDC power supply of the


control panel and the furnace. With Truma
Combi eco plus and Truma Combi comfort
plus, also switch on the 120 VAC power sup-
ply (mains supply).
Default °F (Fahrenheit).
Reset
6. Calibrate temperature sensor (OFFSET) • Select RESET with the rotary push button (8).
The temperature sensor of the connected fur-
nace can be adjusted individually to suit the size • Tap the rotary push button (8).
of the vehicle.
• PR SET is shown in the display.
Setting the offset:
Temperature display Increments Range • Tap the rotary push button (8) to confirm.
°C (Celsius) 1 ± 5 °C hot

°F (Fahrenheit) 1 ± 10 °F

hot

When you have confirmed the selection, the


control panel is initialized.

During this process, INIT... is shown in the


Default °F (Fahrenheit). display.

Display power supply 120 VAC


The icon shows that the 120 VAC power supply
(mains supply) is available.

hot

The icon is displayed only in combination


with a Truma Combi eco plus or
Truma Combi comfort plus.

10
Warning Malfunction

This icon indicates that an operating parameter In case of a malfunction, the control panel im-
has reached an undefined status. In this case, mediately goes to the menu level “Malfunction”
the furnace continues to operate. When the op- and displays the error code of the malfunction.
erating parameter returns to the set range, this
icon extinguishes automatically. The troubleshooting chart can be used to deter-
mine the cause of the warning and remedy the
hot error (see Page 13).

hot
E = Malfunction
112 = Error code
H = Furnace

Display warning code


• Select the icon with the rotary push button (8).

• Tap the rotary push button (8). Cause remedied / return to setting level
The code of the current warning is displayed. • Tap the rotary push button (8).
The troubleshooting chart can be used to de-
termine the cause of the warning and rem- • The furnace is restarted.
edy the error (see Page 13).
This may take a few minutes because of
W = Warning internal time lags of the connected furnace.
hot

42 = Error code If the cause was not remedied, the mal-


H = Furnace function will occur again and the control
panel will again go to the “Malfunction”
menu level.

Cause not remedied / return to setting level


• Press the back button.
Cause remedied / return to setting level
• Tap the rotary push button (8). In this case, the malfunction is not ­acknowl‑
edged in the control panel and the icon re-
Cause not remedied / return to setting level mains. The furnace remains in the malfunc-
• Press the Back button (9). tion status.

In this case, the warning is not acknowl-


edged in the control panel and the icon Maintenance
­remains. The furnace remains in warning
status. This control panel is maintenance-free.

To clean the front, you can use a non-abrasive


cloth moistened with water (and a neutral soap
solution).

11
Technical data

Display
LCD, monochrome, with backlighting
Diagonal 3.3 in. (84 mm)
Dimensions (L x W x H)
3.62 x 4.06 x 1.58 in. (92 x 103 x 40 mm)
Operating temperature range
13 °F to 140 °F (-25 °C to +60 °C)
Storage temperature range
13 °F to 158 °F (-25 °C to +70 °C)
Interface
TIN bus
Power supply
8  – 16.5 VDC
Power consumption
max. 65 mA (100% backlighting)
10 mA (stand-by)
Quiescent current
3 mA (Off)
Weight
approx. 0.22 lb (approx. 100 g)

Subject to change without notice.

12
Troubleshooting chart (Truma Combi furnace)

Error Cause Remedy


code
# 17 Hot water mode with empty water Switch off furnace and allow to cool. Fill boiler
container. with water.
# 18 Warm-air outlet blocked. Check the individual outlet openings.
Circulated air intake blocked. Remove blockage from circulated air intake.
# 21 Room temperature sensor/cable Contact Truma Service.
defective.
# 24 Imminent undervoltage, battery voltage Charge battery.
too low < 10.4 V.
# 41 Electronics blocked. Contact Truma Service.
# 43 Excess voltage > 16.4 V. Check battery voltage and power sources,
such as battery charger.
# 44 Undervoltage, battery voltage too low Charge battery. If necessary, replace old
< 10.0 V. battery.
# 45 Only Truma Combi eco plus or Truma Combi comfort plus models.
No 120 VAC supply voltage. Restore 120 VAC supply voltage.
Overheating protection has responded. Contact Truma Service.
#112, Gas cylinder closed. Check gas supply.
#202, Switch for gas shut-off valve open. Close switch for gas shut-off valve.
#121, Overheating protection has responded. Switch off furnace and allow to cool; if neces-
#211 sary, fill the water container with cold water.
Check warm air outlets and circulated air in-
take and remove blockages.
Switch furnace on again.
#122, Combustion air infeed or exhaust gas Check for obstructions such as slush, ice or
#212 outlet closed. leaves and remove from the openings.
Switch for gas shut-off valve open. Close switch for gas shut-off valve.
Gas pressure regulation system Contact Truma Service.
defective.
Overheating protection has responded. Switch off furnace and allow to cool; if neces-
sary, fill the water container with cold water.
Check warm air outlets and circulated air in-
take and remove blockages.
Switch furnace on again.
Electronics defective. Contact Truma Service.
#255 Furnace has no 12 VDC power supply. Ensure 12 VDC power supply.
No connection between the furnace and Ensure connection between furnace and con-
the control panel. trol panel.
Control panel cable defective. Contact Truma Service.

If none of the measures in the troubleshooting chart proves successful or if fault codes are dis-
played that cannot be found in the troubleshooting chart, please contact the Truma Service Center
at 1-855-558-7862 or one of our authorized service partners.

13
Installation Instructions Description
The CP plus control panel (with polarity pro-
tection) is supplied with voltage via a 12 V
Read and follow safety rules and instruc- connector cable. The control panel is con-
tions before operating this control panel nected with a Truma Combi™ furnace with a
Truma CP plus. connector cable (TIN bus).

Safety information Dimensions


• Installation and service must be performed 3.62 in. (92 mm) 0.35 in.
by an authorized Truma installer, service (9 mm)
agency or OEM. Improper installation, al- Top
teration, service or maintenance can cause

4.06 in. (103 mm)


property damage, personal injury or loss of
life.

0.28 in. (7 mm)


• Do not attempt installation as a Do-it-Your-

0.87 in. (22 mm)


self project.

• Install in recreational vehicles (RVs) only.


RVs are recreational vehicles designed as
temporary living quarters for recreation,
camping, or travel use; such vehicles have 0.71 in. (18 mm)
their own power or are towed by another
vehicle.
Fig. 1 – Image not to scale
• DO NOT modify the appliance in any way.
This is dangerous and will void the warranty.
Installation location
• DO NOT HI-POT appliance unless electron-
ic (circuit board) has been disconnected. Install the control panel in a location that is pro-
tected from moisture and wetness.
• DO NOT use battery charger to supply
power to appliance, even when testing. Install the control panel at eye level so that
it is easy to read the display.
• DO NOT connect the 12 Volt DC power to
the appliance if the vehicle requires weld- • Prepare an installation opening for the con-
ing. Electrical welding will cause serious trol panel.
damage to the appliance. 2.87+0,04 in. (73+1 mm)
0.14 in. (3.5 mm)
• DO NOT shorten the electrical connection
cable(s) or remove the sticker that indicates
polarity.
0.14 in. (3.5 mm)
3.31+0,04 in. (84+1 mm)

• Switch off the vehicle’s on-board power 0.12±0,04 in. (3+1 mm)
supply during installation and when con-
necting the appliance.

• The appliance may be installed only in the


specified position.

USA and CANADA


This appliance must be installed in accordance
with local codes or, in the absence of local
codes, the Standard for Recreational Vehicles,
ANSI A119.2/NFPA 501C or CAN/CSA-Z240 RV.
Fig. 2 – Image not to scale
14
Wiring diagram Installation
• Mount the control panel frame on to the wall
with 4 screws.
TIN-Bus
RJ-12 female

Ø Maximum
+ - - + 0.134 in. (3.5 mm)

Figure 4 – Front view

• Hook the top of the control panel into the


connecting cable

frame via 2 latches.


2 x RJ-12 male

red / black
• Fix the top of the control panel in place with
red

a screw (supplied).
1A

Truma Combi™
• Slide the rotary push button on to the shaft.
12 VDC
Figure 3 – Rear view 1

If any of the original wire as supplied


with the appliance must be replaced, it must be
replaced with wire AWG# 18 - 105 °C - UL1015
or its equivalent.

Connection 2
Danger from electrostatic charge.
Electrostatic charges can destroy the electronics.
4
• Establish a connection to ground (potential 3
equalization) before touching any electronics. Fig. 5

• Observe the ESD regulations. Subject to change without notice.

Install the connector cable (TIN bus) in a


loop so that it is not under tension. It must
be possible to pull the control panel about
8 in. (20 cm) out of the installation opening –
with no tension on the connector. Do not
pull on the connector cable (TIN bus) when
it is plugged into the control panel.

• Plug the connector cable (TIN bus) into


the control panel and run the cable to the
furnace.

• The plus cable must be protected with a


1 ampere fuse.

• Plug in the 12 V connector cable and connect


to a 12 VDC power supply (permanent plus).
15
In case you encounter any problems,
please contact the Truma Service Center
at 855-558-7862 or one of our authorized
service partners. For details see
www.truma.net.

Please have the model number and serial


number (on furnace’s type plate) handy
when you call.

34030-66000 · 01 · 12/2014 · Fo ©

Manufacturing Sales
Truma Gerätetechnik GmbH & Co. KG Truma Corp
Wernher-von-Braun-Straße 12 825 East Jackson Blvd.
85640 Putzbrunn Elkhart, IN 46516
Germany USA
www.truma.com Toll Free 1-855-558-7862
Fax 1-574-538-2426
service@trumacorp.com
www.truma.net

You might also like