Safety definitions ....................................................................... 2 The CP plus control panel controls and monitors
Safety behavior and practices ................................................... 2 a Truma Combi™ furnace with additional
indirect water heating.
Operating Instructions
Available models:
Display and operating elements .......................................... 3
Description ................................................................................ 3 • Truma Combi™ eco
Rotary push button .................................................................... 3 • Truma Combi™ eco plus
Back button ............................................................................... 3 • Truma Combi™ comfort
Instructions for use .................................................................... 3 • Truma Combi™ comfort plus
Initial start-up .......................................................................... 4
Start-up .................................................................................... 4
Control panel on/off ................................................................... 4 Consumer Safety Information
Select setting level .................................................................... 4
Functions ................................................................................. 4
Change room temperature ........................................................ 5
Change hot water level .............................................................. 5 Safety definitions
Select energy mode .................................................................. 6
Select fan speed ........................................................................ 7 This is the safety alert symbol. This symbol
Set the time switch ................................................................... 7 alerts you to potential hazards that can kill or
Set clock .................................................................................... 9 hurt you and others.
Settings ..................................................................................... 9
Display power supply 120 VAC ............................................... 10 indicates a hazardous situation
Warning ................................................................................. 11 which, if not avoided, could result in death or
Malfunction ........................................................................... 11 serious injury.
Maintenance ......................................................................... 11
Technical data ....................................................................... 12 is used to address practices not re-
Troubleshooting chart (Truma Combi furnace) ............... 13 lated to physical injury.
Installation Instructions
Other important information or tips.
Safety information ................................................................... 14
Description .............................................................................. 14
Dimensions .............................................................................. 14 Safety behavior and practices
Installation location ................................................................. 14
Wiring diagram ........................................................................ 15
Connection .............................................................................. 15
Installation ............................................................................... 15 • Use the CP plus control panel only when it
is in a technically sound condition.
California Proposition 65 lists chemical sub- • Have a defective CP plus control panel re-
stances known to the state to cause cancer, paired only by the manufacturer or its ser-
birth defects, death, serious illness or other vice department.
reproductive harm. This product may contain
such substances. • Any alteration to the appliance or its con-
trols can be dangerous and will void the
warranty.
2
Operating Instructions
3
+ Turn clockwise
6
• The menu is scrolled through
5 from left to right
• Increase values (+)
7 4
- Turn counterclockwise
• The menu is scrolled through
from right to left
9 8
• Reduce values (-)
Tap
• Save a selected value
Fig. 1 • Select a menu item, go to the
setting level
1 Display
2 Status line Press (3 seconds)
3 Menu line (top) • Main switching function – con-
4 Menu line (bottom) 3 sec trol panel on/off
5 Power supply display
120 VAC (mains supply)
6 Time switch display
7 Settings/values Back button
8 Rotary push button
9 Back button Press the Back button (9) to go back to a previ-
ous menu and cancel settings. This means that
the previous values remain unchanged.
Description
• A rotary push button (8) is used to select Instructions for use
menu items in the menu lines (3 + 4) and to
adjust settings. • If there is an interruption to the power sup-
ply, the clock has to be reset.
• Information is shown on a backlit display (1).
• If a new furnace is connected to the bus sys-
• The Back button (9) is used to go back to a tem of the control panel, repeat the proce-
previous menu. dure described in “Initial start-up”.
3
Initial start-up Control panel on/off
Perform the following steps for initial start-up: • Press the rotary push button (8) for more
than 3 seconds.
• Switch on the 12 VDC power supply of the
control panel and the furnace. With Truma
Combi eco plus and Truma Combi comfort • Previously set values and operating
plus, also switch on the 120 VAC power sup- parameters are active again when the
ply (mains supply). panel is switched on.
• Start searching for the furnace in menu item • When you switch off the control
“Settings” –> “RESET” –> “PR SET”. panel, any Truma Combi device that
is connected is also switched off
When you have confirmed the selection, the automatically.
control panel is initialized. During this process,
“INIT ..” is shown on the display. The recognized • Because of internal time lags for the
furnace is recorded in the control panel. heating, the switching-off process can
take a few minutes.
Start-up
Start/Stand-by screen Select setting level
When the control panel is connected to the • Tap the rotary push button (8).
power supply, after a few seconds a start screen
is displayed. The display shows the setting level. The first
icon flashes.
4
Change room temperature Change hot water level
• Use the rotary push button (8) to select the • Use the rotary push button (8) to select the
icon in the menu line (3). icon in the menu line (3).
• Tap the button to go to the setting level. • Tap the button to go to the setting level.
• Select the desired temperature with the • Select the desired hot water level with the
rotary push button (8). rotary push button (8).
• Tap the rotary push button (8) to confirm the • Tap the rotary push button (8) to confirm the
value. value.
a a b c d
boost boost boost boost
hot hot hot hot
eco eco eco eco
2 2
3 3
5
Special features in mixed mode
Select energy mode • Interruption in the 120 VAC power supply:
• Use the rotary push button (8) to select the The furnace automatically switches to gas
icon in the menu line (3). mode. When the 120 VAC power supply is
restored, the furnace automatically switches
• Tap the button to go to the setting level. back to mixed mode.
• Select the desired energy mode with the • Fault in combustion process (e.g. fuel
rotary push button (8). shortage):
• Tap the rotary push button (8) to confirm the The furnace automatically switches to elec-
value. tric mode. If the furnace is to run in mixed
mode again, the cause of the malfunction
a b c d e must be remedied and the furnace has to
be started again by going to the menu item
“Malfunction” and pressing the rotary push
button. See “Malfunction” on page 11.
6
Select fan speed Set the time switch
7
Enter the end time Select energy mode
• Use the rotary push button (8) to set the • Select the desired energy mode with the ro-
hours and then the minutes. tary push button (8).
24 h mode 12 h mode • Tap the rotary push button (8) to confirm the
value.
hot hot
hot
= a. m.
= p. m.
The “Select energy mode” menu is dis-
If the start/end time is later than the time played only if a furnace with electric heat-
when you entered the settings, the operat- ing elements is connected
ing parameters are not active until the next (Truma Combi eco plus or
start/end time is reached. Until then, the Truma Combi comfort plus).
operating parameters set outside the time
switch remain valid. Select fan speed
• Select the desired fan speed with the rotary
Set the room temperature push button (8).
• Select the desired room temperature with
the rotary push button (8). • Tap the rotary push button (8) to confirm the
value.
• Tap the rotary push button (8) to confirm the
value. hot
hot
hot
8
Disable the time switch (OFF)
• Tap the rotary push button to go to the set- Settings
ting level.
• Disable the time switch (OFF) with the rotary • Use the rotary push button (8) to select the
push button (8) “Settings” icon in the menu line (4).
• Tap the rotary push button (8) to confirm the • Tap the button to go to the setting level.
value.
1. Show version number of connected
devices
hot Display the version number of furnace and
control panel.
hot
Set clock
2. Backlighting
Change the backlighting of the CP plus control
Display 24 h mode Display 12 h mode panel in 10 increments.
hot hot hot
4 4
= a. m.
= p. m. 3. Language
Select the desired language (English, German,
• Use the rotary push button (8) to select the French, Italian).
“Set clock” icon in the menu line (4).
hot
9
5. °C / °F temperature display 7. Factory setting (RESET)
Select temperature display °C (Celsius) or The reset function resets the control panel to
°F (Fahrenheit). the factory settings. All your settings are de-
leted. Newly connected devices are recognized
hot and recorded in the control panel.
°F (Fahrenheit) 1 ± 10 °F
hot
hot
10
Warning Malfunction
This icon indicates that an operating parameter In case of a malfunction, the control panel im-
has reached an undefined status. In this case, mediately goes to the menu level “Malfunction”
the furnace continues to operate. When the op- and displays the error code of the malfunction.
erating parameter returns to the set range, this
icon extinguishes automatically. The troubleshooting chart can be used to deter-
mine the cause of the warning and remedy the
hot error (see Page 13).
hot
E = Malfunction
112 = Error code
H = Furnace
• Tap the rotary push button (8). Cause remedied / return to setting level
The code of the current warning is displayed. • Tap the rotary push button (8).
The troubleshooting chart can be used to de-
termine the cause of the warning and rem- • The furnace is restarted.
edy the error (see Page 13).
This may take a few minutes because of
W = Warning internal time lags of the connected furnace.
hot
11
Technical data
Display
LCD, monochrome, with backlighting
Diagonal 3.3 in. (84 mm)
Dimensions (L x W x H)
3.62 x 4.06 x 1.58 in. (92 x 103 x 40 mm)
Operating temperature range
13 °F to 140 °F (-25 °C to +60 °C)
Storage temperature range
13 °F to 158 °F (-25 °C to +70 °C)
Interface
TIN bus
Power supply
8 – 16.5 VDC
Power consumption
max. 65 mA (100% backlighting)
10 mA (stand-by)
Quiescent current
3 mA (Off)
Weight
approx. 0.22 lb (approx. 100 g)
12
Troubleshooting chart (Truma Combi furnace)
If none of the measures in the troubleshooting chart proves successful or if fault codes are dis-
played that cannot be found in the troubleshooting chart, please contact the Truma Service Center
at 1-855-558-7862 or one of our authorized service partners.
13
Installation Instructions Description
The CP plus control panel (with polarity pro-
tection) is supplied with voltage via a 12 V
Read and follow safety rules and instruc- connector cable. The control panel is con-
tions before operating this control panel nected with a Truma Combi™ furnace with a
Truma CP plus. connector cable (TIN bus).
• Switch off the vehicle’s on-board power 0.12±0,04 in. (3+1 mm)
supply during installation and when con-
necting the appliance.
Ø Maximum
+ - - + 0.134 in. (3.5 mm)
red / black
• Fix the top of the control panel in place with
red
a screw (supplied).
1A
Truma Combi™
• Slide the rotary push button on to the shaft.
12 VDC
Figure 3 – Rear view 1
Connection 2
Danger from electrostatic charge.
Electrostatic charges can destroy the electronics.
4
• Establish a connection to ground (potential 3
equalization) before touching any electronics. Fig. 5
34030-66000 · 01 · 12/2014 · Fo ©
Manufacturing Sales
Truma Gerätetechnik GmbH & Co. KG Truma Corp
Wernher-von-Braun-Straße 12 825 East Jackson Blvd.
85640 Putzbrunn Elkhart, IN 46516
Germany USA
www.truma.com Toll Free 1-855-558-7862
Fax 1-574-538-2426
service@trumacorp.com