PROPOSED SATELLITE MONITORING CENTER BILL NO.

2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

BILL NO. 2/6


HVAC INSTALLATIONS

AIR CONDITIONING AND VENTILATION


WORKS

Supply, Installation, Testing & Commissioning


Of Air Conditioning Equipment As Specified.

VRF SYSTEM

Supply,Installation,Testing and Commissioning


of variable refrigerant flow modular type
indoor units wired/wireless remote suitable for
R410a refrigerant comprising of all accessories
as per the specifications. The indoor units shall
be suitable to work on cooling as well as
heating mode.The minimum Energy Efficiency
Ratio shall be as per ASHRAE STANDARDS
90.1 -2001 table 6.2.1B. The indoor units
shall be suitable for operation on 220 ±6%
volts, 50Hz, 1 phase AC power supply.
Ductable indoor units shall be suitable to
handle extent of ductwork as shown in the
design drawings and dehumidified air quantity
as mentioned in the heat load summary sheet
under "Special Conditions". The indoor unit shall
be complete with pre filter & remote as per
requirement The indoor units shall be of
following capacities:

INDOOR UNITS

FAN COIL UNIT

FCU-B1-01, 02 of air flow rate 642 L/s and total


A 2 No's 4,500.00 9,000.00
cooling coil load of 7.2 kW

FCU-B1-03 of air flow rate 434 L/s and total


B 1 No 4,500.00 4,500.00
cooling coil load of 7.8 kW

FCU-B1-04 of air flow rate 116 L/s and total


C 1 No 2,800.00 2,800.00
cooling coil load of 2.8 kW

BOQ;Page 2/6/1
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

To Collection QR. 16,300.00

FAN COIL UNIT (Cont'd..,)

FCU-B1-05 of air flow rate 642 L/s and total


A 1 No 4,500.00 4,500.00
cooling coil load of 7.9 kW

FCU-B1-06 of air flow rate 559 L/s and total


B 1 No 4,200.00 4,200.00
cooling coil load of 7.6 kW

FCU-B1-07 of air flow rate 274 L/s and total


C 1 No 3,500.00 3,500.00
cooling coil load of 3.2 kW

FCU-B1-08 of air flow rate 430 L/s and total


D 1 No 4,200.00 4,200.00
cooling coil load of 5.8 kW

FCU-B1-09 of air flow rate 429 L/s and total


E 1 No 4,200.00 4,200.00
cooling coil load of 5.5 kW

FCU-B1-10 of air flow rate 144 L/s and total


F 1 No 2,800.00 2,800.00
cooling coil load of 2.5 kW

FCU-B1-11 of air flow rate 327 L/s and total


G 1 No 3,500.00 3,500.00
cooling coil load of 4.1 kW

FCU-B1-12 of air flow rate 397 L/s and total


H 1 No 3,750.00 3,750.00
cooling coil load of 9.4 kW

FCU-B1-13 of air flow rate 127 L/s and total


J 1 No 2,800.00 2,800.00
cooling coil load of 3.0 kW

FCU-B1-14, 15 of air flow rate 925 L/s and total


K 2 No's 5,000.00 10,000.00
cooling coil load of 10.7 kW

FCU-B1-16 of air flow rate 409 L/s and total


L 1 No 4,000.00 4,000.00
cooling coil load of 5.1 kW

FCU-B1-17, 18 of air flow rate 537 L/s and total


M 2 No's 4,200.00 8,400.00
cooling coil load of 7.9 kW

FCU-B1-19 of air flow rate 866 L/s and total


N 1 No 4,750.00 4,750.00
cooling coil load of 9.7 kW

BOQ;Page 2/6/2
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

FCU-B1-20 of air flow rate 866 L/s and total


P 1 No 4,750.00 4,750.00
cooling coil load of 9.6 kW
To Collection QR. 65,350.00

CEILING SUSPENDED UNIT

CSU-B1-01, 02 of air flow rate 607 L/s and total


A 2 No's 4,500.00 9,000.00
cooling coil load of 9.6 kW

CSU-B1-03, 04, 05 of air flow rate 639 L/s and


B 3 No's 4,500.00 13,500.00
total cooling coil load of 7.6 kW

CSU-B1-06, 07 of air flow rate 832 L/s and total


C 2 No's 4,500.00 9,000.00
cooling coil load of 14.2 kW

CSU-B1-08, 09 of air flow rate 627 L/s and total


D 2 No's 4,500.00 9,000.00
cooling coil load of 7.8 kW

CSU-B1-10, 11 of air flow rate 563 L/s and total


E 2 No's 4,200.00 8,400.00
cooling coil load of 9.9 kW

CEILING MOUNTED 4 WAY CASSETTE


UNITS

CU-B1-01, 01A of air flow rate 106 L/s and total


F 2 No 3,750.00 7,500.00
cooling coil load of 1.5 kW

CU-B1-02, 02A of air flow rate 130 L/s and total


G 2 No 3,750.00 7,500.00
cooling coil load of 1.8 kW

HI WALL UNITS

IDU-B1-01 of air flow rate 158 L/s and total


H 1 No 3,200.00 3,200.00
cooling coil load of 2.7 kW

IDU-B1-02 of air flow rate 356 L/s and total


J 1 No 4,100.00 4,100.00
cooling coil load of 5.2 kW

IDU-B1-03, 04, 05 of air flow rate 273 L/s and


K 3 No's 3,800.00 11,400.00
total cooling coil load of 3.2 kW

IDU-B1-06 of air flow rate 74 L/s and total


L 1 No 3,000.00 3,000.00
cooling coil load of 1.7 kW

BOQ;Page 2/6/3
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

IDU-B1-07 of air flow rate 278 L/s and total


M 1 No 3,800.00 3,800.00
cooling coil load of 3.6 kW

To Collection QR. 89,400.00

HI WALL UNITS (Cont'd..,)

IDU-B1-08 of air flow rate 87 L/s and total


A 1 No 3,000.00 3,000.00
cooling coil load of 1.3 kW

IDU-B1-09, 10 of air flow rate 410 L/s and total


B 2 No's 4,100.00 8,200.00
cooling coil load of 4.6 kW

THERMOSTAT

Wall mounted type thermostat as per


C 50 No's 250.00 12,500.00
specification

CRAC UNIT

Bottom discharge type double skin CRAC unit


complete with multiple evaporative blowers, DX
cooling coil, heater, humidifier and
microprocessor control panel. The unit has to be
BMS compatible, necessary MODBUS interface
card has to be included to enable complete
transfer of data and to set all parameters from
the BMS system. The necessary MS stand to
match the false flooring to be included. The cost
should include power connections between the
isolator switch.

CRAC-B1-01, 02 of air flow rate of 2976 l/s and


D 2 No's 35,000.00 70,000.00
total cooling load 34.9 kW

FRESH AIR HANDLING UNIT

BOQ;Page 2/6/4
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

Fresh Air handling unit, DX type, complete with


plate heat exchanger, cooling coil, condensate
pan, fresh air fan, exhaust fan, starters, filters,
vibration isolator, necessary valves, Expansion
kit, control panel, insulations and all necessary
accessories and connections as per drawing,
details and in accordance with the Specification.
The cost should include power connections
between the isolator switch.

FAHU-B1-01 with supply and exhaust air flow of


E 1 No 38,000.00 38,000.00
3150 l /s

To Collection QR. 131,700.00

TREATED FRESH AIR UNIT

Treated Fresh Air unit, DX type, complete with,


horse shoe heat pipe, cooling coil, condensate
pan, fresh air fan, starters, filters, vibration
isolator, necessary valves, Expansion kit,
control panel, insulations and all necessary
accessories and connections as per drawing,
details and in accordance with the Specification.
Additionally, the condensing unit shall
comprises of multiple compressors, condenser
coil, condenser fans. as per the specifications.
The cost should include power connections
between the isolator switch and the outdoor
unit, anti-vibration pad for the outdoor unit and
concrete base with all the accessories, control
and electric connections.

A TFA-B1-01 with supply air flow of 1744 l /s 1 No 22,000.00 22,000.00

DX TYPE AIR HANDILING UNIT

BOQ;Page 2/6/5
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

Air Handling unit, DX type, complete with,


cooling coil, condensate pan, fan, starters,
filters, vibration isolator, necessary valves,
Expansion kit, control panel, insulations and all
necessary accessories and connections as per
drawing, details and in accordance with the
Specification. Additionally, the condensing unit
shall comprises of multiple compressors,
condenser coil, condenser fans. as per the
specifications. The cost should include power
connections between the isolator switch and the
outdoor unit, anti-vibration pad for the outdoor
unit and concrete base with all the accessories,
control and electric connections.

B AHU-B1-01,02 with supply air flow of 3579 l /s 2 No's 36,000.00 72,000.00

To Collection QR. 94,000.00

EXHAUST FANS

Supply Installation, testing & Commissioning of


Low noise application exhaust fans, complete
with motor, statically or dynamically balanced
die-cast-in-aluminium impeller; rolled steel
channel supporting frames, anti-vibration
mountings, acoustic lining enclosure etc.,
complete as specified and indicated on the
drawings, equipment schedule and technical
specification of following capacties;

AXIAL FAN

SEF-B1-01 (2Hr's and 250°C fire rated), with air


A 1 No 25,000.00 25,000.00
flow rate of 5250 l/s

B EF-B1-02 ,with air flow rate of 174 l/s 1 No 950.00 950.00

BOQ;Page 2/6/6
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

TWIN EXHAUST FAN

C EF-B1-01,with air flow rate of 600 l/s 1 No 6,500.00 6,500.00

DUCTED INLINE FAN

D EF-B1-03,with air flow rate of 141 l/s 1 No 950.00 950.00

BIFURCATED FANS (BATTERY ROOM)

Bifurcated exhaust fans switch


operated,complete with motor, statically or
dynamically balanced die-cast-in-aluminium
impeller; rolled steel channel supporting frames,
anti-vibration mountings, acoustic lining
enclosure etc., complete as specified and
indicated on the drawings; connections to local
power outlets; installed on as shown on the
drawings; connections to ductwork.

E EF-B1-04, 05 with air flow rate of 86 l/s 2 No's 2,300.00 4,600.00

To Collection QR. 38,000.00

REFRIGERANT PIPE INSTALLATION

Refrigerant copper piping for interconnecting the


VRF indoor and out door units as per the AC
equipment capacity complete with pipe
protection and insulation as per the supplier's
recommendations and specification.

A Ø 6.35 mm 45 m 9.00 405.00

B Ø 9.52 mm 165 m 12.00 1,980.00

C Ø 12.7 mm 117 m 15.00 1,755.00

D Ø 15.88 mm 210 m 17.00 3,570.00

BOQ;Page 2/6/7
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

E Ø 19.05 mm 125 m 19.00 2,375.00

F Ø 19.52 mm 5 m 19.00 95.00

G Ø 22.2 mm 130 m 21.00 2,730.00

H Ø 28.58 mm 153 m 32.00 4,896.00

J Ø 34.9 mm 113 m 42.00 4,746.00

K Ø 38.1 mm 55 m 36.00 1,980.00

L Ø 41.3 mm 42 m 60.00 2,520.00

M Ø 44.5 mm m 55.00 -

Refrigerant copper piping for interconnecting the


CRAC indoor and out door units as per the AC
equipment capacity complete with pipe
protection and insulation as per the supplier's
recommendations and specification.

N Ø 15.88 mm 41 m 17.00 697.00

P Ø 28.58 mm 25 m 32.00 800.00

To Collection QR. 28,549.00

Refrigerant copper piping for interconnecting the


AHU,TFA & FAHU indoor and out door units as
per the AC equipment capacity complete with
pipe protection and insulation as per the
supplier's recommendations and specification.

A Ø 15.88 mm 108 m 17.00 1,836.00

B Ø 28.58 mm 90 m 32.00 2,880.00

C Ø 41.20 mm 48 m 60.00 2,880.00

D Ø 22.2 mm 95 m 21.00 1,995.00

E Ø 44.5 mm 48 m 70.00 3,360.00

BOQ;Page 2/6/8
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

AIR CONDITIONING DUCTWORK

Supply, Fabrication, Installation and testing of


Galvanized sheet metal ventilation ductwork
and fittings confirming to the latest HVAC
/ASHRAE /SMACNA /DW144 duct construction
standards complete as specified and indicated
on the drawings; including test holes, turning
vanes, splitters, stiffeners, transformation
pieces, access, panels and doors etc. on and
including supports.

Not over 600mm wide ducts with minimum


F thickness of 0.6mm including fittings and 1,150 m2 160.00 184,000.00
accessories.

Over 601mm but not exceeding 1000mm wide


G ducts with minimum thickness of 0.8mm 300 m2 158.00 47,400.00
including fittings and accessories.

Over 1000mm wide ducts with minimum


H thickness of 1mm including fittings and 400 m2 180.00 72,000.00
accessories.

To Collection QR. 316,351.00

AIR CONDITIONING DUCTWORK


INSULATION

Supply, Fabrication and Installation of fiber


glass insulation material of 48 kg / m³ density,
thermal conductivity limited to 0.037 W/m/°C
and wrapped with reinforced aluminum foil and
covered with high quality canvass cloth 200
gm/m³ soaked in weather proofing compound
and sealed with vapor barrier seal (as
applicable) as per technical specification and
local standard.

A For Concealed duct of 25mm thick insulation 2,312 m2 110.00 254,320.00

BOQ;Page 2/6/9
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

Acoustic insulation as per technical


B 463 m2 88.00 40,744.00
specification and local standard.

FLEXIBLE CONNECTION

Supply, installation and testing of Flexible


connection not exeding 1.5m, as per technical
specification and local standard.

C Ø 200mm 355 m 73.00 25,915.00

FIRE RATED DUCT

Supply, installation, testing and commissioning


of Fire rated ducts (2Hr's & 250°C) as per
technical specification and local standards and
as shown in the drawings including all
accessories such as insulation, Inspection door,
Access door, etc,.

D 1.2 mm thick black steel sheet duct works 300 m2 210.00 63,000.00

1mm thick stainless steel duct works


E 30 m2 195.00 5,850.00
(Battery room Exhaust)

To Collection QR. 389,829.00

FIRE DAMPER

Supply, installation, testing and commissioning


of Fire damper as per technical specification
and local standards and as shown in the
drawings including all accessories; fix in position
with ductwork of following sizes.

A 750 x 400 1 No's 800.00 800.00

BOQ;Page 2/6/10
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

B 150 x 100 11 No's 350.00 3,850.00

C 250 x 200 1 No's 550.00 550.00

D 250 x 250 6 No's 550.00 3,300.00

E 400 x 250 3 No's 600.00 1,800.00

F 200 x 200 6 No's 400.00 2,400.00

G 200 x 100 2 No. 400.00 800.00

H 1200 x 550 8 No's 1,450.00 11,600.00

J 250 x 150 2 No's 550.00 1,100.00

K 200 x 150 4 No's 400.00 1,600.00

L 550 x 300 2 No. 700.00 1,400.00

M 450 x 250 3 No's 600.00 1,800.00

N 250 x 100 2 No. 450.00 900.00

P 550 x 250 1 No's 800.00 800.00

Q 350 x 250 2 No. 500.00 1,000.00

R 300 x 150 1 No's 500.00 500.00

S 800 x 400 5 No's 1,000.00 5,000.00

T 1100 x 550 4 No's 1,450.00 5,800.00


To Collection QR. 45,000.00

FIRE DAMPER(Cont'd ..,)

A 400 x 400 3 No's 700.00 2,100.00

B 150 x 150 1 No's 500.00 500.00

VOLUME CONTROL DAMPER

BOQ;Page 2/6/11
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

Supply, installation, testing and commissioning


of Volume Control Damper as per technical
specification and local standards and as shown
in the drawings including all accessories; fix in
position with ductwork as per drawings,
equipment schedule and technical specification
of the following sizes.

C 250 x 150 1 No's 300.00 300.00

D 250 x 200 3 No's 300.00 900.00

E 450 x 250 3 No's 450.00 1,350.00

F 200 x 200 3 No's 250.00 750.00

G 200 x 100 10 No's 250.00 2,500.00

H 550 x 300 1 No's 600.00 600.00

J 200 x 150 9 No's 350.00 3,150.00

K 150 x 100 19 No's 300.00 5,700.00

L 350 x 200 1 No's 350.00 350.00

M 550 x 250 1 No's 550.00 550.00

N 300 x 200 4 No's 350.00 1,400.00

P 450 x 200 3 No's 450.00 1,350.00

Q 300 x 150 7 No's 350.00 2,450.00

R 150 x 150 2 No's 200.00 400.00


To Collection QR. 24,350.00

VOLUME CONTROL DAMPER (Cont'd ..,)

A 300 x 100 5 No's 300.00 1,500.00

B 250 x 250 2 No. 250.00 500.00

BOQ;Page 2/6/12
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

C 1200 x 550 2 No's 1,100.00 2,200.00

D 250 x 100 3 No's 350.00 1,050.00

E 150 x 200 1 No's 300.00 300.00

F 600 x 550 1 No's 550.00 550.00

G 700 x 550 1 No's 800.00 800.00

BACK DRAFT DAMPER

Supply, installation, testing and commissioing of


Back Draft Damper as per technical
specification and local standards and as shown
in the drawings including all accessories; fix in
position with ductwork of following sizes.

H 200 x 200 2 No's 250.00 500.00

J 450 x 250 1 No. 450.00 450.00

K 250 x 250 1 No. 250.00 250.00

L 250 x 200 2 No. 250.00 500.00

M 200 x 100 2 No. 250.00 500.00

N 300 x 200 1 No. 300.00 300.00

To Collection QR. 9,400.00

SOUND ATTENUATOR

BOQ;Page 2/6/13
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

Supply, installation, testing and commissioing of


Sound attenuators, including all accessories
complete as per technical specification, local
standards and as indicated on the drawings;
jointing to ductwork (minimum length 1200mm)
of following sizes

A 1200 x 550 2 No's 1,500.00 3,000.00

B 800 x 400 1 No. 1,200.00 1,200.00

FRESH AIR SANDTRAP LOUVER

Supply, installation, testing and commissioing of


Fresh air inlets with Pre fillter, 2'' washable
alluminium filter, High efficiency filter with
powder coated finish to approved color,
including sand trap louvers and insect screen /
bird guard, sand trap as per secification.

C 1500 x 1200 3 No's 2,100.00 6,300.00

D 300 x 200 1 No. 800.00 800.00

EXHAUST AIR LOUVER

Supply, installation, testing and commissioing of


Exhaust air louver with powder coated finish to
approved color, including insect screen / bird
guard, louver as per secification.

E 1600 x 1000 1 No. 1,500.00 1,500.00

F 750 x 400 1 No's 750.00 750.00

G 250 x 250 1 No. 250.00 250.00

H 400 x 200 1 No. 400.00 400.00

J 300 x 300 1 No. 400.00 400.00

To Collection QR. 14,600.00

BOQ;Page 2/6/14
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

MOTORIZED DAMPER

Supply, installation, testing and commissioing of


louver type motorised dampers confirm to
SMACNA/NFPA in duct work with access door,
actuator, matching flanges, gasketts & bolts,
etc., The item shall be complete including all the
fittings and accessories as detailed in drawings
and technical specifications and local standards.
The actuator shall be ON/FF type. The actuator
shall be capable of accepting 240 V AC supply,
the controller shall be BMS ready and
communicable to BACNET protocal with
communication port. The item should be
complete in all respect including all fittings,
supports and accessories required for its
complete installation and proper functioning as
per standards,equipment schedule, technical
specifications and details in drawings of
following sizes.

A 1200 x 550 4 No's 1,450.00 5,800.00

MOTORIZED SMOKE DAMPER

Supply, installation, testing and commissioing of


fire rated motorised Smoke dampers (250°C
and 2hrs) conform to SMACNA/NFPA in duct
work with access door, actuator, matching
flanges, gasketts & bolts, etc., The item shall be
complete including all the fittings and
accessories as detailed in drawings and
technical specifications and local standards.
The actuator shall be ON/FF type. The actuator
shall be capable of accepting 240 V AC supply,
the controller shall be BMS ready and
communicable to BACNET protocal with
communication port. The item should be
complete in all respect including all fittings,
supports and accessories required for its
complete installation and proper functioning as
per standards,equipment schedule, technical
specifications and details in drawings of
following sizes.

B 1200 x 500 2 No's 1,350.00 2,700.00

C 200 x 200 1 No 800.00 800.00

BOQ;Page 2/6/15
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

TO COLLECTION QR 9,300.00

BOQ;Page 2/6/16
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

MOTORIZED FIRE DAMPER

Supply, installation, testing and commissioning


of louver type motorized fire dampers conform
to SMACNA/NFPA in duct work with access
door, actuator, matching flanges, gaskets &
bolts, etc., The item shall be complete including
all the fittings and accessories as detailed in
drawings and technical specifications and local
standards. The actuator shall be ON/FF type.
The actuator shall be capable of accepting 240
V AC supply, the controller shall be BMS ready
and communicable to BACNET protocol with
communication port. The item should be
complete in all respect including all fittings,
supports and accessories required for its
complete installation and proper functioning as
per standards, equipment schedule, technical
specifications and details in drawings of
following sizes.

A 1200 x 500 1 No 1,350.00 1,350.00

B 750 x 300 1 No 1,000.00 1,000.00

BUTTERFLY DAMPER

Supply, installation, testing and commissioning


of butterfly damper as per technical specification
and local standards and as shown in the
drawings including all accessories; fix in position
with ductwork as per drawings, equipment
schedule and technical specification of the
following sizes.

C 250mm dia 38 No's 350.00 13,300.00

D 200 mm dia 9 No's 300.00 2,700.00

E 150mm dia 101 No's 300.00 30,300.00

BOQ;Page 2/6/17
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

TO COLLECTION QR 48,650.00

AIR INLETS AND OUTLETS

Supply, installation, balancing/testing of Supply,


return and exhaust air grilles and diffusers along
with insulated plenum boxes (as applicable) as
specified in the technical specification, local
codes and standards and drawings, extruded
aluminium construction with powder coated
finish to approved colour; complete with
supports and flexible connections; fixing in
position including connections to ductwork as
per standards, equipment schedule, technical
specifications and details in drawings of
following sizes.

Supply air circular diffuser with damper , sizes


as follows

A Ø 315 mm neck size & Ø 463 outer size 8 No's 350.00 2,800.00

Return air circular diffuser , sizes as follows

B Ø 315 mm neck size Ø 463 outer size 6 No's 350.00 2,100.00

Supply linear slot diffuser with dampers, sizes


as follows

C 25 mm 3 slot, length 1m 12 No's 1,350.00 16,200.00

D 25 mm 2 slot, length 1m 89 No's 1,250.00 111,250.00

E 25 mm 1 slot, length 1m 3 No's 1,000.00 3,000.00

Return linear slot diffuser, sizes as follows

F 25 mm 2 slot, length 1m 48 No's 1,250.00 60,000.00

G 25 mm 1 slot, length 1m 3 No's 1,500.00 4,500.00

BOQ;Page 2/6/18
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

TO COLLECTION QR 199,850.00

BOQ;Page 2/6/19
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

AIR INLETS AND OUTLETS (Cont'd )

Supply air square diffuser with dampers, sizes


as follows

A neck size 150 x 150 mm outer size 225 x 225 6 No's 275.00 1,650.00

neck size 225 x 225 mm & outer size 305 x


B 14 No's 275.00 3,850.00
305

C neck size 300 x 300 mm & outer size 375 x 375 3 No's 350.00 1,050.00

Return air square diffuser without dampers,


D
sizes as follows

E neck size 150 x 150 mm & outer size 225 x 225 4 No's 275.00 1,100.00

Supply air grill with collar dampers, sizes as


follows

F 750 x 100 mm 24 No's 750.00 18,000.00

G 1000 x 200 mm 2 No's 800.00 1,600.00

H 750 x 150 mm 12 No's 750.00 9,000.00

J 1200 x 500 8 No's 900.00 7,200.00

K 800 X 250 7 No's 750.00 5,250.00

L 450 x 100 1 No's 450.00 450.00

M 200 x 100 11 No's 450.00 4,950.00

N 300 x 150 7 No's 450.00 3,150.00

Return air grill without dampers, sizes as follows

P 100 mm linear grill 57 m 450.00 25,650.00

Q 750 x 150 mm 12 No's 1,200.00 14,400.00

BOQ;Page 2/6/20
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

TO COLLECTION QR 97,300.00

AIR INLETS AND OUTLETS (Cont'd )

A 750 x 300 mm 1 No's 750.00 750.00

B 750 x 250 8 No's 750.00 6,000.00

Exhaust air squar diffuser, sizes as follows

C Neck size 150 x150 mm & outer size 225 x 225 25 No's 250.00 6,250.00

neck size 225 x 225 mm & outer size 305 x


D 1 No's 250.00 250.00
305

Exhaust air grill with collar dampers, sizes as


follows

E 900 x 250 7 No's 850.00 5,950.00

Supply air Floor grill with collar dampers, sizes


as follows

F 600 x 600 8 No's 750.00 6,000.00

AIR CURTAIN

Design, Supply, installation, testing &


commissioning of Air curtain, isolator, starter,
etc and all necessary accessories and fittings as
per technical specification and local standards
of following sizes

G ARC - 01 to 05 of 2m length 5 No's 7,500.00 37,500.00

H ARC - 06 to 07 of 1m length 2 No's 6,500.00 13,000.00

BOQ;Page 2/6/21
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

TO COLLECTION QR 75,700.00

ELECTRICAL HEATER

Supply, Installation, testing & Commissioning of


duct mounted type electrical heater complete
with thyristor control panel and all necessary
wirings and all needed for proper working as per
drawings, equipment scheudle and technical
specification of the following size.

Duct mounted size Electrical heater capacity


A 1 No 3,000.00 3,000.00
EH-B1-01 of 20.9 kW

PRESSURIZATION FAN

Supply Installation, testing & Commissioning of


Low noise application exhaust fans, complete
with motor, statically or dynamically balanced
die-cast-in-aluminium impeller; rolled steel
channel supporting frames, anti-vibration
mountings, acoustic lining enclosure etc.,
complete as specified and indicated on the
drawings, equipment schedule and technical
specification of following capacties

B Pressurization Fan FAF-B1-01 of 50 L/s 1 No 4,500.00 4,500.00

BOQ;Page 2/6/22
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

TO COLLECTION QR 7,500.00

BUILDER'S WORK IN CONNECTION WITH


AIR CONDITIONING AND VENTILATION
INSTALLATION.

Allow for the following.

Holes openings, chases, cutting back, building


in pipes, ductwork, sleeves, lintels over
A Item
openings and making good finishing as
necessary.

Concrete plinths; including waterproofing for


B Item
airconditioning unit as necessary.

25000 25,000.00

Concrete plinths including waterproofing for duct


C Item
& pipe support as necessary.

Wall brackets as detailed specified for


D Item
supporting ductwork

Allow for any other builder's work deemed


E necessary in connection with the ventilation and Item
airconditioning installation.

BOQ;Page 2/6/23
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

TO COLLECTION QR 25,000.00

SUNDRIES IN CONNECTION WITH


AIRCONDITIONING AND VENTILATION
INSTALLATION.

Allow for the following.

Marking the position of holes, mortices, chases


A Item
and the like in the structure.

Plates, discs, labels, tagging and charts for


B Item
identification of plant, equipment and the like.

C Loose keys, tools and spare parts as specified. Item 15000 15,000.00

Temporarily operating, the Installations and


D assisting the CLIENT in the operations and Item
maintenance of the Installations.

E Training to Client Personnel on HVAC System Item

BOQ;Page 2/6/24
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

TO COLLECTION QR 15,000.00

Collection

Page 2/6/1 16,300.00

Page 2/6/2 65,350.00

Page 2/6/3 89,400.00

Page 2/6/4 131,700.00

Page 2/6/5 94,000.00

Page 2/6/6 38,000.00

Page 2/6/7 28,549.00

Page 2/6/8 316,351.00

Page 2/6/9 389,829.00

Page 2/6/10 45,000.00

Page 2/6/11 24,350.00

Page 2/6/12 9,400.00

Page 2/6/13 14,600.00

Page 2/6/14 9,300.00

Page 2/6/15 48,650.00

BOQ;Page 2/6/25
PROPOSED SATELLITE MONITORING CENTER BILL NO.2: SMC BUILDING
AT WADI AL MARKHIYA HVAC WORKS

Item Description Quantity Unit Rate (QR) Amount (QR)

Page 2/6/16 199,850.00

Page 2/6/17 97,300.00

Page 2/6/18 75,700.00

Page 2/6/19 7,500.00

Page 2/6/20 25,000.00

Page 2/6/21 15,000.00


TOTAL FOR HVAC INSTALLATIONS To Summary 1,741,129.00