CHAPTER FIVE

CONCLUSIONS AND RECOMMENDATIONS

This chapter completes this project report. A summary of the project is presented and a

personal experience is also presented as how the process of this project affected the

designer.

Findings

The Internet becoming centralized as intelligence gathering of the world has

made it a center of the spot for development resulting in better internet and

communication network to further improve all other operations and businesses that uses

such technology. The high internet speed development is also due to the increasing use

of fiber optics which is gaining demand in the market. Development must meet the rising

demands of the increasing users. Structured cabling having met the needs have further

developed and exploited the very potentials of the data network. Having said, the

demand of the Power over Ethernet is due the increasing for such reasons as structured

cabling meets the need for higher bandwidth and power, while limiting the rise in

temperature. It also reduces the need for additional wiring and redundant cabling which

in turn lower the costs of the design.


Conclusions

This project is successful in attaining the desired objectives, being able to design

a structured cabling for four story commercial building and present its estimated costs.

This design is ready for implementations and replication. Further conclusions can be

drawn after application of the design.

Recommendations

In the design of the project, the Engineer recommends for the significant

improvement of the project, such as;

1. Improved and personalized security for the building’s main server. As designing

good data network system, it is enticing possible exploitations from unknown and

unwanted individuals.

2. Properly and adequately distributed networks. Depending on changes of floor or

room purposes, a single room may use several network connections.

3. Determine the key areas of potential savings from costs of adjustments and
replacements.

Personal Experiences

Pinaka-una nku nga impression sa paghimu sa Structured Cabling

Designing is lisud gyud sya ilabi na di kabalo og AutoCAD nakadugag pud sa kalisud

individual pa og labaw sa tanan ang Time Management although gi pa pasa mig ni Sir

Pabs sa Time Management Plan lisud sya isingit aside sa study kay time kay kasagara

pud akong sobra na oras idula sa mobile legends og itulog na lang. Pero kani tanan
akoa na pangitaan og paagi ilabi na diskartehana naku kay naa pud mga previous batch

nga nagkuha sa ACE41 last year mao akoa gipangutan-an og gikuhaan og reference.

Mao tanan akong abi nga d makaya og mahimu abi ra taman kay akoa pud gi set akong

huna-hunaa nga isa pud nis rason nganu nag eskwela para maka tuon maghatag og

oras, pag focus sa butang dili sya imposible nga matun-an.

Pero kani pagbuhat naku sa Structured Cabling Designing dili gyud masugdan

og wala sa GUIDANCE sa among instructor Engr. Ian Giovanni R. Pabillaran, daghan

salamat kayo Sir isa ka sa pinaka chill, buotan nga instructor nga dili pud angay

abusaran pero labaw sa tanan QUALITY pud ang mahatag na pagtudlo, makaingon kog

hayahay kay SURE PASS pero daghan kog natun-an aside sap pag design pati na pud

sa mga TIPS sa kinabuhi kay ma ENGINEER man gyud gyapon ko PUHON pina agi

usab pud sa KALUOY SA GINOO. Salamat kayo Sir.

Tapuson naku sa sa is aka quote akong Personal Experience

“Mga Engineer mong tanan pero dili Dungan”

- Engr. Eliseo Linog

You might also like