Professional Documents
Culture Documents
Submittal - Thakher City Project Building - Rga
Submittal - Thakher City Project Building - Rga
Submittal - Thakher City Project Building - Rga
Part of
1 Company Profile
2 Trade License
4 Certification
8 Warranty Certificate
9 Project List
10 Project Approvals
C O M P A NY P R O F I L E
Part of
MADA GYPSUM
COMPANY
The Company was established in
2005 in Yanbu and produces its products
according to the international
standards EN and ASTM. The production
capacity is 400,000 t of plasters and 34
million m2 of plasterboard, more than
7.5 million m2 of Laminated gypsum Ceiling
Tiles and more than 2 million m2 of cement
boards.
WHY MADA
This makes MGC the biggest
GYPSUM?
plasterboard producer in KSA. With its Ͱ ISO certified
product mix and approach to the market, Ͱ World Class manufacturing processes
Dry Wall Academy for market education, first Ͱ Latest state of the art process
system solution for Dry Wall Systems, Mada equipment from Gyptech and Grelbex
Gypsum has become a market leader in the Ͱ Quality control system
MENA region. Ͱ In-house laboratory
Ͱ Production according to ASTM and EN
standards
Ͱ Third party laboratories certificates
Ͱ Best gypsum product mix in GCC
Ͱ Own gypsum rock quarry for best raw
material quality control
Ͱ Sustainable raw materials and input
materials quality control
Ͱ Technical literature to support
consultants, architects and specifiers.
Ͱ On-site technical support
Ͱ Specification (drawings) of solution
based on customers need
Ͱ PROCEM
Customized Systems
Ͱ In addition to standard applications, Mada’s strong
Single source of supply
specification engineering team can work with the Ͱ Mada Plus Systems helps drywall contractors
designers and architects of specific projects to offer source their complete requirement from a single
systems suiting specific needs of a particular projects. source, thereby considerably reducing the
complexity involved in projects. In addition, Mada
ensures that different components that goes in
the systems are compatible to each other, thereby
On Site Technical Support ensuring performance, integrity, and longevity of
Ͱ For selected locations Mada can provide onsite technical the system.
support to teach the applicators for correct application of
dry wall partition to achieve system performance. Technical literature
Ͱ Mada Plus Systems are supported by several
technical literatures (system book, system
Recycling Facility selector, installation manuals etc.) to help the
project identify the right system as well as correct
Ͱ Mada Gypsum Company has its own recycling facility method of application. In addition, a wide range
for Plasterboard, thus offering projects additional of typical drawings are made available to easily
opportunity to gain LEED points. integrate Mada Plus Systems within the overall
project masterplan.
Mada Plus drywall systems are offered as both standard off the shelf requirements, and tailor made
according to the specifications of the project.
Performance
Sound Insulation – up to 65 dB
Impact Rating
2. Acoustic
Acoustic insulation is the term describing the reduction of sound that passes between two spaces
separated by a dividing element. In transmitting between two spaces, the sound energy may pass
through the dividing element (direct transmission) and through the surrounding structures (indirect or
flanking transmission). In designing for Acoustic insulation, it is important to consider both methods
of transmission. The walls or floors, which flank the dividing element, constitute the main paths for
flanking transmission, but this can also occur at windows, heating or ventilation ducts, doorways, etc.
For these reasons it is unlikely that figures quoted from laboratory test conditions will be achieved in
practice on site.
The Building regulation requirements regarding the sound insulation of walls and partitions relate to
the transmission of airborne sounds. These include speech, musical instruments, loudspeakers and
other sounds that originate in and are transmitted through the air.
Mada Plasterboards
Mada Plus Plasterboards are produced from high purity natural gypsum core with some
additives encased in closely adhering best selected paper linings of different types. Mada
Plasterboards are complying with ASTM C1396 & EN 520 standard.
Mada J Track is forming the Horizontal element of a shaft wall structure into which
the vertical CH-Studs and E-Studs are fixed.
Mada J Deflection Track is forming the Horizontal element of a shaft wall structure into
which the vertical CH-Studs and E-Studs are fixed. It provides a friction fit for the stud
and also provide a slip joint to allow any movement of the structure. It is positioned
at the top to guide CH-Studs.
Mada Main Channel forms the primary frame of the drywall ceiling framework. It is
suspended from the ceiling roof using hooked wire, adjustment clip or rigid hangers.
Mada Furring channel is designed for furr-out any surface for application of final
finish. It forms the secondary frame of the drywall ceiling framework.
Mada Wall angle forms the periphery of the drywall ceiling framework. It is fixed to
the wall with the help of anchors & serves as support for intermediate channels.
Mada Self Tapping bugle head screws have the ability to advance while creating its
own thread. It is used for fastening drywall and other accessories mounting on steel
structures below 0.8mm thickness.
Mada Self Drilling bugle head screws also known as Tek screws; eradicate the need
for a pre-drilled hole and allow drilling and tie to be done in the same motion. It is
used for fastening drywall and other accessories mounting on steel structures from
0.8mm up to 3.0mm thick
Mada PROCEM Self Drilling screws are special corrosion protected screws with
countersunk head and ribs under head for fixing of Mada PROCEM cement boards to
the metal framing.
Mada Wafer Head Screws are used for fixing together metal framing members
Mada Hex Head Self Drill Screws are used to fasten metal to metal or metal to other
accessories from 0.8mm to 3.0mm thickness. It has excellent tensile strength,
Wedge Anchors
Wedge anchors are made from galvanized steel and have multiple uses in non
structural cracked and uncracked concrete. They are specially used for fixing hangers,
brackets, and all kinds of drywall profiles to concrete slab where high work load,
safety and rigidity of the installation is required.
Drop in Anchor
The DynaSet™ Drop-In Anchor is an all steel, medium duty, displacement setting,
expansion anchor designed to provide a permanent anchorage point in concrete.
Its internal thread allows it to be used with both machine bolts and threaded rod,
placing no restrictions on fixture thickness.
Trubolt Anchor
Trubolt Stud Anchor is a true-to-size, heavy duty, torque controlled expansion anchor,
for permanent anchoring into concrete.
Hollow Wall Anchor is a zinc plated metal fixing with metric screw for fixing directly
into the board lining of the wall and / or ceiling. The screw can be removed and
refitted again.
Mada Fire Guard sealant is developed for use as a joint seal in drywall systems and
through penetration fire stop systems. As an acrylic based caulk with a tenacious
bond regardless of porosity, it is easy to use on virtually any job. Mada Fire Guard
Sealant has a long shelf life and good open time. It is Water & chemical resistant
(Mild Chemical) can be painted and also contains anti-microbial protection to inhibit
the growth of sustain caused by mold & mildew It can be applied with all commonly
available hand-gun equipment.
Mada Jointing Compound contains vinyl binders and other ingredients that provide
performance superior to that of ordinary ready mix products, blended to creamy
smooth consistency. It gives excellent slip and bond and ease workability. It can be
used directly from the pail and require minimal mixing thinning and re-tempering.
Mada French Adhesive is a special gypsum product for interiors and exteriors. It is
used for adhering of decorations and cornices to the wall and for special cladded
walls where Plasterboard is directly glued to the walls.
Mada L Bracket is used at the floor and soffit to support the wall studs. Its simple
shape of L which is rigid enough to resist moments & shear to an extent.
One arm of L is fixed to a vertical ( wall stud) and other projecting horizontally
fixed to the support of wall ceiling or slab
These brackets are helpful in application of framing for bulkheads & ceilings
having large suspension drop, wall linings, etc.
Slotted l Brackets are designed typically for both Internal & External applications
to resist high moment & shear due to excessive loading (Live load, Seismic
&Wind)
The vertical slots on the bracket allows to take deflection for slab.
Mada external corner beads are used to straight, durable, corrosion and impact
resistant protection to the edges and corners of dray-wall systems. It is concealed
with Mada multi-purpose joint compound to deliver a smooth finished corner.
Casing Bead
Mada Casing Bead are squared corner beads that fit firmly over the edge of the
plasterboard for protection against impact. A range of casing beads are available to
fit different plasterboard thicknesses.
Mada shadow gap angle bead provides straight and neat finishing details for
internal corners of the dray wall system.
Mada control / expansion joint bead is used for areas where there is a long
continuous wall ( > 8 m ). It is used to prevent the cracks which can occur through the
expansion and contraction of material due the variation in temperature, moisture
etc.
ﺷﻬﺎﺩﺓ
CERTIFICATE
ﺗﺸﻬﺪ ﺍﻟﻬﻴﺌﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎﺓ ﻭﺍﻟﺪﺧﻞ ﺑﺄﻥ ﺍﻟﻤﻜﻠﻒ /ﺷﺮﻛﺔ ﻣﺪﻯ ﻟﻠﺠﺒﺲ ﺍﻟﻤﺤﺪﻭﺩﺓ
ﻭﻗﺪ ﻣﻨﺢ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﻩ ﻟﺘﻤﻜﻴﻨﻪ ﻣﻦ ﺇﻧﻬﺎﺀ ﺟﻤﻴﻊ ﻣﻌﺎﻣﻼﺗﻪ ﺑﻤﺎ ﻓﻲ ﺫﻟﻚ ﺻﺮﻑ ﻣﺴﺘﺤﻘﺎﺗﻪ
ﺍﻟﻨﻬﺎﺋﻴﺔ ﻋﻦ ﺍﻟﻌﻘﻮﺩ.
ﺗﺸﻬﺪ ﻭﺯﺍﺭﺓ ﺍﻟﻌﻤﻞ ﻭﺍﻟﺘﻨﻤﯿﺔ ﺍﻻﺟﺘﻤﺎﻋﯿﺔ ﺑﺄﻥ ﺍﻟﻤﻨﺸﺄﺓ ﺍﻟﻤﺬﮐﻮﺭﺓ ﺃﻋﻼﻩ ﺣﻘﻘﺖ ﻧﺴﺐ ﺍﻟﺘﻮﻃﯿﻦ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻣﻨﻬﺎ..
ﻭﺗﻢ ﻣﻨﺤﻬﺎ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﺣﺴﺐ ﻃﻠﺒﻬﺎ
ﺗﻨﺒﻴﻬﺎﺕ:
- ٢ﻓﻲ ﺣﺎﻝ ﺍﻛﺘﺸﺎﻑ ﺃﻱ ﻋﻤﻠﻴﺔ ﺗﺰﻭﻳﺮ ﻓﻲ ﺍﻟﺸﻬﺎﺩﺓ ﺍﻟﻤﻘﺪﻣﺔ ﻧﺮﺟﻮ ﺍﻟﺘﺒﻠﻴﻎ ﻋﻦ ﺫﻟﻚ ﺑﺨﻄﺎﺏ ﺭﺳﻤﻲ ﻷﻗﺮﺏ ﻣﻜﺘﺐ ﻋﻤﻞ.
١٤٤١/٠٦/١٦ ﺍﻟﺘﺎﺭﻳﺦ
٢٠٢٠/٠٢/١٠ ﺍﻟﻤﻮﺍﻓﻖ
ﺭﻣﺰ ﺍﻟﺸﻬﺎﺩﺓ ٣٢٠٤٢٢٨٤
ﺷﻬﺎﺩﺓ
ﻛﺘﺎﺑﺔ ﺭﻗﻤﺎ
ﺍﺛﻨﺎﻥ ﻭ ﺍﺭﺑﻌﻮﻥ ﻣﺸﺘﺮﻛﺎ ٤٢ ﻋﺪﺩ ﺍﻟﻤﺸﺘﺮﻛﻴﻦ ﺍﻟﺴﻌﻮﺩﻳﻴﻦ
ﻣـﺎﺋﺔ ﻭ ﺛﻼﺛﺔ ﻭ ﺧﻤﺴﻮﻥ ﻣﺸﺘﺮﻛﺎ ١٥٣ ﻋﺪﺩ ﺍﻟﻤﺸﺘﺮﻛﻴﻦ ﻏﻴﺮ ﺍﻟﺴﻌﻮﺩﻳﻴﻦ
ﻣـﺎﺋﺔ ﻭ ﺧﻤﺴﺔ ﻭ ﺗﺴﻌﻮﻥ ﻣﺸﺘﺮﻛﺎ ١٩٥ ﺍﻟﻤﺠﻤﻮﻉ
ﺗﺸﻬﺪ ﺍﻟﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ ﺑﺄﻥ ﺍﻟﻤﻨﺸﺄﺓ ﺍﻟﻤﺬﻛﻮﺭﺓ ﺃﻋﻼﻩ ﻗﺪ ﺃﻭﻓﺖ ﺑﺈﻟﺘﺰﺍﻣﺎﺗﻬﺎ ﺗﺠﺎﻩ ﺍﻟﻤﺆﺳﺴﺔ
ﻭﻓﻖ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻤﻘﺪﻣﺔ ﻣﻨﻬﺎ ﺣﺘﻰ ﺗﺎﺭﻳﺦ ﺇﺻﺪﺍﺭ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ،ﻭﺍﻟﺘﻲ ﺗﻢ ﻣﻨﺤﻬﺎ ﻟﺘﻘﺪﻳﻤﻬﺎ ﻷﻳﺔ ﺟﻬﺔ ﺗﻄﻠﺒﻬﺎ ،ﻭﻫﻲ
ﺻﺎﻟﺤﺔ ﻟﺠﻤﻴﻊ ﺍﻷﻏﺮﺍﺽ ﺍﻟﺘﻲ ﻧﺺ ﻋﻠﻴﻬﺎ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ ﻓﻲ ﺍﻟﻤﺎﺩﺓ ) (٦/١٩ﻣﻨﻪ.
ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﺳﺎﺭﻳﺔ ﺍﻟﻤﻔﻌﻮﻝ ﺣﺘﻰ ١٤٤١/٠٧/١٦ﻫـ.
ﻋﻦ ﻃﺮﻳﻖ ﺍﺳﺘﺨﺪﺍﻡ ﺃﻭ ﻳﻠﺰﻡ ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﺻﺤﺔ ﻭﺻﻼﺣﻴﺔ ﺍﻟﺸﻬﺎﺩﺓ ﻋﺒﺮ ﺯﻳﺎﺭﺓ ﺍﻟﺮﺍﺑﻂ
ﺍﻟﺮﻣﺰ ﺍﻟﻤﻌﺮﻑ ﺍﻟﺘﺎﻟﻲ : ﺃﺩﻧﺎﻩ ﻓﻲ ﺍﻟﻤﻮﻗﻊ ﺍﻹﻟﻜﺘﺮﻭﻧﻲ ﻟﻠﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ
www.gosi.gov.sa/vc
ﺗﻌﺪ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﻣﻦ ﺍﻟﻮﺛﺎﺋﻖ ﺍﻻﻟﻜﺘﺮﻭﻧﻴﺔ ﺍﻟﺤﻜﻮﻣﻴﺔ ﺍﻟﺮﺳﻤﻴﺔ ،ﻭﻳﺤﻈﺮ ﻗﻄﻌﻴﺎ ﺗﻘﻠﻴﺪﻫﺎ ﺃﻭ ﺇﺩﺧﺎﻝ ﺃﻱ ﺗﻌﺪﻳﻼﺕ ﻋﻠﻴﻬﺎ ﺳﻮﺍﺀ ﺑﺎﻹﺿﺎﻓﺔ ﺃﻭ ﺍﻟﺤﺬﻑ
ﺃﻭ ﺍﻟﺘﻐﻴﻴﺮ ﻓﻲ ﺑﻴﺎﻧﺎﺗﻬﺎ ﺃﻭ ﻏﻴﺮ ﺫﻟﻚ ﻣﻦ ﺍﻧﻮﺍﻉ ﺍﻟﺘﻌﺪﻳﻞ ،ﻭﺗﻌﺪ ﺍﻟﺸﻬﺎﺩﺓ ﻻﻏﻴﺔ ﺇﺫﺍ ﺷﺎﺑﻬﺎ ﺷﻲﺀ ﻣﻦ ﺫﻟﻚ ،ﻛﻤﺎ ﺗﻌﺮﺽ ﺻﺎﺣﺒﻬﺎ ﻟﻠﻤﻼﺣﻘﺔ ﺍﻟﻨﻈﺎﻣﻴﺔ
ﺃﻣﺎﻡ ﺍﻟﺠﻬﺎﺕ ﺍﻟﻤﺨﺘﺼﺔ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﻣﺎﻳﻔﺮﺿﻪ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ﻣﻦ ﻋﻘﻮﺑﺎﺕ ،ﻭﻻﻳﺠﻮﺯ ﺗﺪﺍﻭﻝ ﺍﻟﺸﻬﺎﺩﺓ ﺇﻻ ﻓﻲ ﺍﻷﻏﺮﺍﺽ ﺍﻟﺘﻲ
ﺃﺻﺪﺭﺕ ﻷﺟﻠﻬﺎ ﻭﻓﻘﺎ ﻷﺣﻜﺎﻡ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ،ﻭﺍﻟﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ﻏﻴﺮ ﻣﺴﺆﻭﻟﻪ ﻋﻦ ﺃﻱ ﺁﺛﺎﺭ ﺃﺧﺮﻯ ﻣﺘﺮﺗﺒﺔ
ﻗﺒﻞ ﺍﻟﻐﻴﺮ ﻋﻦ ﺍﻟﺸﻬﺎﺩﺓ ﻭﻏﻴﺮ ﻣﺴﺆﻭﻟﺔ ﻋﻦ ﺃﻱ ﻋﻤﻠﻴﺔ ﺗﺰﻭﻳﺮ ﺃﻭ ﺗﻌﺪﻳﻞ ﺗﺘﻢ ﻋﻠﻰ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻴﻬﺎ .
100171000053598
ﺗﺸﻬﺪ اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺄن اﳌﻜﻠﻒ :ﴍﻛﺔ ﻣﺪى ﻟﻠﺠﺒﺲ اﳌﺤﺪودة
ﻣﺴﺠﻞ ﰲ ﴐﻳﺒﺔ اﻟﻘﻴﻤﺔ اﳌﻀﺎﻓﺔ ﺑﺘﺎرﻳﺦ ١٤٣٨/١٢/٠٣ :ﻫـ ،وﺗﺤﻤﻞ اﻟﺮﻗﻢ اﻟﴬﻳﺒﻲ ٣٠٠٨٩٨٤٩٨٤٠٠٠٠٣ :
ﺗﺸﻬﺪ اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺄن اﳌﻜﻠﻒ /ﴍﻛﺔ ﻣﺪى ﻟﻠﺠﺒﺲ اﳌﺤﺪودة
ﴍﻛﺔ رﻗﻢ ٧٠٠١٦٧٧٧٩٣وﺳﺠﻞ ﺗﺠﺎري رﻗﻢ ٤٧٠٠٠٠٩٥١٥
ﻗﺪم إﻗﺮاره ﻋﻦ اﻟﻔﱰة اﳌﻨﺘﻬﻴﻪ ﰲ ٢٠١٧/١٢/٣١م
وﻗﺪ ﻣﻨﺢ ﻫﺬه اﻟﺸﻬﺎده ﻟﺘﻤﻜﻴﻨﻪ ﻣﻦ إﻧﻬﺎء ﺟﻤﻴﻊ ﻣﻌﺎﻣﻼﺗﻪ ﻤﺑﺎ ﰲ ذﻟﻚ ﴏف ﻣﺴﺘﺤﻘﺎﺗﻪ اﻟﻨﻬﺎﺋﻴﺔ ﻋﻦ اﻟﻌﻘﻮد.
ﻳﴪي ﻣﻔﻌﻮل ﻫﺬه اﻟﺸﻬﺎدة ﺣﺘﻰ ﺗﺎرﻳﺦ ١٤٤٠/٠٨/٢٥ﻩ اﳌﻮاﻓﻖ ٢٠١٩/٠٤/٣٠م.
)اﻟﺨﺎﻣﺲ و اﻟﻌﴩون ﻣﻦ ﺷﻌﺒﺎن أﻟﻒ و أرﺑﻌﺎﻤﺋﺔ و أرﺑﻌﻮن ﻫﺠﺮي(
اﻟﺨﺘﻢ اﻟﺮﺳﻤﻲ
Project Name
THAKHER CITY - MAKKAH - ARABIAN ROOTS
ASTM EN
STANDARDS STANDARDS TECHNICAL PROPOSAL
Revision: 07
Client: THAKHER
Date: 28TH SEPTEMBER 2017
Area: WESTERN REGION
Project Code: MGC - 3127
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420
PROJECT NAME THAKHER CITY - MAKKAH
The purpose of this document is to provide a technical proposal based on the submitted
technical documents provided by the Concern / Consultant / End user.
Our technical proposal is based on Test Results, Calculations, Test Reports and Certification,
and is representing the most comparable system solutions to your provided technical documentation.
It is the responsibility of the contractor to obtain approval for the submitted proposal from the consultant.
All application quantities and delivery amounts are based on empirical data that is not easily
transferable to other deviating areas.
The quantities are calculated per m2 drywall partition/ceiling without addition for loss and waste.
The Performance of Mada Technical Systems and Products can solely be ensured with the
exclusive use of Mada system components or other products expressly recommended by Mada.
This technical proposal is based on the information contained in BOQ, Drawing & Specification.
For further Technical information or clarification regarding Technical proposal please contact:
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420
PROJECT NAME THAKHER CITY - MAKKAH
System Construction
Material Description Units Side A Side B
Plasterboard Type 15 mm Mada Plus Fire Resistant Plasterboard Mada Plus Fire Resistant Plasterboard
Plasterboard Layers 1 1
Metal Framing : C - Stud 0.60 mm Size 68 mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT - Track 0.60 mm Size 70 mm x 50mm flanges - Top
Metal Framing : U - Track 0.60 mm Size 70 mm x 32mm flanges - Bottom
Metal Framing : Noggins 0.60 mm Noggins made from Mada U-Track 70 mm x 32mm flanges - Board cut joints
Top Anchor M6 x 55mm Trubolt Anchor @600 centres
Bottom Anchor M6 x 55mm Trubolt Anchor @600 centres
M3.5 x 35mm Self Tapping Screw
Drywall Screws
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Approved Insulation Glasswool Insulation 16kg/m3
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
Wall Height – Refer System Performance Table
WALL
Mada Plus Plasterboard as
specified
System Construction
Material Description Units Side A Side B
Plasterboard Type 15 mm Mada Plus Fire Resistant Plasterboard Mada Plus Fire Resistant Plasterboard
Plasterboard Layers 1 1
Metal Framing : C - Stud 0.60 mm Size 123 mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT - Track 0.60 mm Size 125 mm x 50mm flanges - Top
Metal Framing : U - Track 0.60 mm Size 125 mm x 32mm flanges - Bottom
Metal Framing : U - Track 0.60 mm Noggins made from Mada U-Track 125 mm x 32mm flanges - Board Cut Joints
Top Anchor M6 x 55mm Trubolt Anchor @600 centres
Bottom Anchor M6 x 55mm Trubolt Anchor @600 centres
M3.5 x 35mm Self Tapping Screw
Drywall Screws
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
Wall Height – Refer System Performance Table
System Construction
Material Description Units Side A Side B
Plasterboard Type 12.5 mm Mada Plus Fire Resistant Plasterboard Mada Plus Fire Resistant Plasterboard
Plasterboard Layers 2 2
Metal Framing : C - Stud 0.60 mm Size 98 mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT - Track 0.60 mm Size 100 mm x 50mm flanges - Top
Metal Framing : U - Track 0.60 mm Size 100 mm x 32mm flanges - Bottom
Metal Framing : FC 0.60 mm 72mm x 12/12mm flanges @Horizontal board cut joints
Top Anchor M6 x 55mm Trubolt Anchor @600 centres
Bottom Anchor M6 x 55mm Trubolt Anchor @600 centres
M3.5 x 25mm Self Tapping Screw – 1st layer
Drywall Screws M3.5 x 45mm Self Tapping Screw – 2nd layer
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
Wall Height – Refer System Performance Table
WALL
Mada Plus Plasterboard as
specified
System Construction
Material Description Units Side A Side B
Plasterboard Type 12.5 mm Mada Plus Regular Plasterboard Mada Plus Regular Plasterboard
Plasterboard Layers 2 2
Metal Framing : C - Stud 0.60 mm Size 148 mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT - Track 0.60 mm Size 150 mm x 50mm flanges - Top
Metal Framing : U - Track 0.60 mm Size 150 mm x 32mm flanges - Bottom
Metal Framing : FC 0.60 mm 72mm x 12/12mm flanges @Horizontal board cut joints
Top Anchor M6 x 55mm Trubolt Anchor @600 centres
Bottom Anchor M6 x 55mm Trubolt Anchor @600 centres
M3.5 x 25mm Self Tapping Screw – 1st layer
Drywall Screws M3.5 x 45mm Self Tapping Screw – 2nd layer
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
Wall Height – Refer System Performance Table
WALL
Mada Plus Plasterboard as
specified
System Construction
Material Description Units Side A Side B
Plasterboard Type 12.5 mm Mada Plus Fire Resistant Plasterboard Mada Plus Fire Resistant Plasterboard
Plasterboard Layers 2 2
Metal Framing : C - Stud 0.60 mm Size 148 mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT - Track 0.60 mm Size 150 mm x 50mm flanges - Top
Metal Framing : U - Track 0.60 mm Size 150 mm x 32mm flanges - Bottom
Metal Framing : FC 0.60 mm 72mm x 12/12mm flanges @Horizontal board cut joints
Top Anchor M6 x 55mm Trubolt Anchor @600 centres
Bottom Anchor M6 x 55mm Trubolt Anchor @600 centres
M3.5 x 25mm Self Tapping Screw – 1st layer
Drywall Screws M3.5 x 45mm Self Tapping Screw – 2nd layer
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
Wall Height – Refer System Performance Table
WALL
Mada Plus Plasterboard as
specified
System Construction
Material Description Units Side A Side B
Mada Plus Fire Resistant Plasterboard Mada Plus Moisture Resistant
Plasterboard Type 15 mm
Plasterboard
Plasterboard Layers 1 1
Metal Framing : C - Stud 0.60 mm Size 68mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT - Track 0.60 mm Size 70 mm x 50mm flanges - Top
Metal Framing : U-Track 0.60 mm Size 70mm x 32mm flanges - Bottom & Noggin
Top Anchor M6 x 55 mm Trubolt Anchor @600mm centres
Bottom Anchor M6 x 55 mm Trubolt Anchor @600mm centres
M3.5 x 35mm Self Tapping Screw
Drywall Screws
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Approved Insulation Glasswool Insulation 16kg/m3
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
WALL
Wall Height – Refer System Performance Table
System Construction
Material Description Units Side A Side B
Mada Plus Fire Resistant Plasterboard Mada Plus Moisture Resistant
Plasterboard Type 15 mm
Plasterboard
Plasterboard Layers 1 1
Metal Framing : C - Stud 0.60 mm Size 123mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT - Track 0.60 mm Size 125mm x 50mm flanges - Top
Metal Framing : U-Track 0.60 mm Size 125mm x 32mm flanges - Bottom & Noggin
Top Anchor M6 x 55 mm Trubolt Anchor @600mm centres
Bottom Anchor M6 x 55 mm Trubolt Anchor @600mm centres
M3.5 x 35mm Self Tapping Screw
Drywall Screws
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Approved Insulation Glasswool Insulation 16kg/m3
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
WALL
Wall Height – Refer System Performance Table
System Construction
Material Description Units Side A Side B
Mada Plus Fire Resistance Plasterboard Mada Plus Fire & Moisture Resistant
Plasterboard Type 15 mm
Plasterboard
Plasterboard Layers 1 1
Metal Framing : C - Stud 0.60 mm Size 123mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT-Track 0.60 mm Size 125mm x 50mm flanges - Top
Metal Framing : U-Track 0.60 mm Size 125mm x 32mm flanges - Bottom
Top Anchor M6 x 55 mm Trubolt Anchor @600mm centres
Bottom Anchor M6 x 55 mm Trubolt Anchor @600mm centres
M3.5 x 35mm Self Tapping Screw
Drywall Screws
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Approved Insulation Glasswool Insulation 16kg/m3
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
WALL
Wall Height – Refer System Performance Table
System Construction
Material Description Units Side A Side B
Mada Plus Fire & Moisture Resistant
Plasterboard Type 12.5 Mada Plus Fire Resistant Plasterboard
Plasterboard
Plasterboard Layers 2 2
Metal Framing : C - Stud 0.60 mm Size 98 mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT - Track 0.60 mm Size 100 mm x 50mm flanges - Top
Metal Framing : U - Track 0.60 mm Size 100 mm x 32mm flanges - Bottom
Metal Framing : FC 0.60 mm 72mm x 12/12mm flanges @Horizontal board cut joints
Top Anchor M6 x 55mm Trubolt Anchor @600 centres
Bottom Anchor M6 x 55mm Trubolt Anchor @600 centres
M3.5 x 25/45mm Self Tapping Screw
Drywall Screws
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Approved Insulation Glasswool Insulation 16kg/m3
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
Wall Height – Refer System Performance Table
WALL
Mada Plus Plasterboard as
specified
System Construction
Material Description Units Side A Side B
Mada Plus Fire Resistant Plasterboard Mada Plus Fire & Moisture Resistant
Plasterboard Type 12.5
Plasterboard
Plasterboard Layers 2 2
Metal Framing : C - Stud 0.60 mm Size 148 mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT - Track 0.60 mm Size 150 mm x 50mm flanges - Top
Metal Framing : U - Track 0.60 mm Size 150 mm x 32mm flanges - Bottom
Metal Framing : FC 0.60 mm 72mm x 12/12mm flanges @Horizontal board cut joints
Top Anchor M6 x 55mm Trubolt Anchor @600 centres
Bottom Anchor M6 x 55mm Trubolt Anchor @600 centres
M3.5 x 25/45mm Self Tapping Screw
Drywall Screws
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Approved Insulation Glasswool Insulation 16kg/m3
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
Wall Height – Refer System Performance Table
WALL
Mada Plus Plasterboard as
specified
System Construction
Material Description Units Side A Side B
Mada Plus Fire & Moisture Resistant Mada Plus Fire & Moisture Resistant
Plasterboard Type 15 mm
Plasterboard Plasterboard
Plasterboard Layers 1 1
Metal Framing : C - Stud 0.60 mm Size 123mm Spacing 600 mm Height Ref. Table
Metal Framing : DHT-Track 0.60 mm Size 125mm x 50mm flanges - Top
Metal Framing : U-Track 0.60 mm Size 125mm x 32mm flanges - Bottom
Top Anchor M6 x 55 mm Trubolt Anchor @600mm centres
Bottom Anchor M6 x 55 mm Trubolt Anchor @600mm centres
M3.5 x 35mm Self Tapping Screw
Drywall Screws
M4.2 x 13mm Wafer Head Screw - Bottom Track to Stud
Finishing Mada Jointing Tape & Multi Purpose Jointing Compound
Approved Insulation Glasswool Insulation 16kg/m3
Sealant Mada Fire Guard Acrylic Sealant
THICKNESS
WALL
Wall Height – Refer System Performance Table
Deflection:
• Where a deflection head is required to allow for soffit movement, use Mada Deflection head track at soffit detail. Deflection limit of a
standard partition is 08 - 10 mm. For higher deflection limit contact Mada Technical department for guidance.
Control Joints:
• Movement control joints are recommended at a maximum span of 15m. Control joints should also be installed to concur with any
movement joints in the structure.
• Control joints in interior walls shall be installed where a wall or partition runs in an uninterrupted straight plane exceeding 9.1 m.
• Control joints in interior ceilings with perimeter relief shall be installed so that linear dimensions between control joints do not exceed
15m and total area between control joints does not exceed 230 m2.
• Control joints in interior ceilings without perimeter relief shall be installed so that linear dimensions between control joints do not
exceed 10m and total area between control joints does not exceed 80 m2.
• Control joints shall be installed where ceiling framing members change direction.
Penetrations:
• Please be aware that the Fire & Acoustic performance are affected if the penetrations are not properly treated. Please refer to Mada
drawings or consult the MEP Contractor to ensure that the Fire & Acoustic performance is not affected. Please contact Mada Technical
department for further information and guidance.
Metal Profile Specifications:
• Mada cold formed metal profiles are manufactured using galvanized steel coils with a minimum zinc coating mass of Z180 or Z275 [180 /
275 Grams of Zinc per m2). Steel Grade JIS 3302, SGCC
Plasterboard Specifications:
• Mada Plus plasterboard are manufactured to ASTM C1396 / C1396M Standard and EN 520 Standards
• Regular Plasterboard – ASTM C1396 / C1396M & EN 520 Type A
• Fire Resistant Plasterboard - ASTM C1396 / C1396M Type X & EN 520 Type I, F
• Moisture Resistant Plasterboard - ASTM C1396 / C1396M & EN 520 Type A & H1
• Fire & Moisture Resistant Plasterboard - ASTM C1396 / C1396M Type X & EN 520 Type I, F & H1
• Impact Resistant Plasterboard - ASTM C1396 / C1396M Type X & EN 520 Type D, F, I & R
• Acoustic Resistant Plasterboard - ASTM C1396 / C1396M & EN 520 Type D
Wall stability:
• The wall height at site may not exceed the one specified in respective Mada documentation.
• Wall stability shall be ensured by correct fixing of peripheral profiles so the surrounding structures.
• The wall studs of dimensions as specified shall be installed at spacing distances not exceeding 600 mm as specified.
• The wall lined by boards at one side may not be exposed to air pressure over 0.10 kPa until the other side is lined by boards.
• The stability of the wall with height over 6.0 m stretching over the great length of should be increased by walls branching off at
maximum 6.0 m intervals.
Limitations
• The design proposed is not as per scale and shall be read in concurrence with structural or architectural drawings.
• The Contractor to ensure the workability of the proposed system.
• The information contained in the drawing is the Property and Copyright of Mada Gypsum Co and must not be re-issued, copied or
reproduced without written consent. 14
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420
PROJECT NAME THAKHER CITY - MAKKAH
Duct Penetration
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420
PROJECT NAME THAKHER CITY - MAKKAH
Range of Products
Furring Channel Main Channel Wall Angle Fixing Channel J-Runner Track
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420
TECHNICAL DATA SHEET
[BOARDS]
TECHNICAL DATA SHEET
Advantages
• Light Weight Construction, Easy
& Fast Installation Material Storage &
• Improved strength & SAG Handling Conditions
Resistant
• Mada Plus Plasterboards to be
MADA PLUS • Good Fire Protection stored on pallets or on a pack of
boards and supported evenly on a
REGULAR • Good Sound Insulation & Good
firm, dry, level and structurally
Thermal Insulation
sound floor. Load up to 4 pallets
PLASTERBOARD “Part of Mada Plus Drywall System:
of Plasterboards on each other.
System performance warranty only
Product Description by using the proposed Mada plus • Do not store any other material
system products.” on top of Plasterboards.
Mada Plus Plasterboards are Product Characteristics • Protect Plasterboards from direct
produced from high purity natural rain, sunlight or other extensive
gypsum core being sheeted in a • Length : Standard length is weather conditions.
closely adhering best selected 2400mm & 3000mm. Special
• Mada Plus Plasterboards to be
paper liners. Mada Plus Regular length is 1800mm to 4500mm
stored in dry area inside the
Plasterboard has fiber glass which • Width : 1200mm & 1220mm. building which is ready to receive
improves strength and Sag drywall fixings.
resistnace. It is lightweight for use • Thickness : 9.5mm, 12.5mm,
in standard internal wall and 15mm & 16mm.
ceiling applications. • Edge : Tapered, Square, Beveled & Material Packing Details
Field of Application Round.
Mada Plus Regular Plasterboard • Color : Ivory / Grey
used in Residential Buildings, Board Boards Per
• Fire Rating (Mada System Thickness Pallet
Commercial Buildings, Hospitals, application) - Tested as per
Airports, Educational Institutions ASTM E119 9.5 mm 90
and other such applications.
• Acoustic Rating (Mada System 12.5 mm 66
Manufacturing Standard application) - Tested as per
ASTM E90 15.0 mm 54
Mada Plus Plasterboards are Technical Specification 16.0 mm 54
produced to ASTM C1396 /
C1396M & EN 520 Type A
standards. Tested accordance to ASTM C473-06a Plaster Board Thickness (mm)
ASTM E84 & ASTM 473
Parameters 9.5 12.5 15 16
Weight (kg / m2) +/- 0.2 7.0 9.8 11.0 11.7
Min Board Density (kg / m3) 736 784 733 731
Flame Spread Index Nil Nil Nil Nil
Smoke Developed Index Nil Nil Nil Nil
Asbestos (% by weight) Nil Nil Nil Nil
“MGC reserves the right to
Flexural Strength (N)(Ⱶ) >400 493 620 645
update technical parameters as
per its own discretion. For official Flexural Strength (N)(ǁ) >160 264 310 326
use of this TDS please consult
Nail Pull Resistance (N) >260 425 485 561
Mada Technical department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Light Weight Construction, Easy Material Storage &
& Fast Installation
Handling Conditions
• Improved strength & SAG • Mada Plus Plasterboards to be
MADA PLUS Resistant stored on pallets or on a pack of
• Good Fire Protection boards and supported evenly on a
MOISTURE RESISTANT firm, dry, level and structurally
• Good Sound Insulation & Good
sound floor. Load up to 4 pallets
PLASTERBOARD Thermal Insulation
of Plasterboards on each other.
“Part of Mada Plus Drywall System:
Product Description
System performance warranty only • Do not store any other material
by using the proposed Mada plus on top of Plasterboards.
Mada Plus Plasterboards are
produced from high purity natural system products.” • Protect Plasterboards from direct
gypsum core being sheeted in a Product Characteristics rain, sunlight or other extensive
closely adhering best selected paper weather conditions.
• Length : Standard length is
liners. Mada Plus Moisture Resistant • Mada Plus Plasterboards to be
2400mm & 3000mm. Special
Plasterboard has fiber glass which stored in dry area inside the
length is 1800mm to 4500mm
improves strength and Sag building which is ready to receive
resistnace. It is lightweight for use in • Width : 1200mm & 1220mm.
drywall fixings.
standard internal wall and ceiling • Thickness : 9.5mm, 12.5mm,
applications where Moisture 15mm & 16mm. Material Packing Details
Resistant properties is required.
• Edge : Tapered, Square, Beveled &
Field of Application Round.
Mada Plus Moisture Resistant Board Boards Per
Plasterboard used in Residential • Color : Green / Grey Thickness Pallet
Buildings, Commercial Buildings, • Fire Rating (Mada System
9.5 mm 90
Hospitals, Airports, Educational application) - Tested as per
Institutions and other such ASTM E119 12.5 mm 66
applications.
• Acoustic Rating (Mada System 15.0 mm 54
Manufacturing Standard application) - Tested as per
ASTM E90 16.0 mm 54
Mada Plus Plasterboards are
Technical Specification
produced to ASTM C1396 /
C1396M & EN 520 Type A & H1
standards. Tested accordance to ASTM C473-06a Plaster Board Thickness (mm)
ASTM E84 & ASTM 473 Parameters 9.5 12.5 15 16
Weight (kg / m2) +/- 0.2 7.2 9.5 11.4 12.1
Min Board Density (kg / m3) 757 760 760 756
Flame Spread Index Nil Nil Nil Nil
Smoke Developed Index Nil Nil Nil Nil
Asbestos (% by weight) Nil Nil Nil Nil
“MGC reserves the right to
Flexural Strength (N)(Ⱶ) >400 487 575 670
update technical parameters as
per its own discretion. For official Flexural Strength (N)(ǁ) >160 213 256 267
use of this TDS please consult
Nail Pull Resistance (N) >260 395 420 503
Mada Technical department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Light Weight Construction, Easy
Material Storage &
& Fast Installation
Handling Conditions
• Good Fire Protection
• Mada Plus Plasterboards to be
MADA PLUS FIRE • Good Sound Insulation & Good stored on pallets or on a pack of
Thermal Insulation
RESISTANT boards and supported evenly on a
firm, dry, level and structurally
“Part of Mada Plus Drywall System:
PLASTERBOARD System performance warranty only
sound floor. Load up to 4 pallets
of Plasterboards on each other.
by using the proposed Mada plus
Product Description system products.” • Do not store any other material
on top of Plasterboards.
Product Characteristics
Mada Plus Plasterboards are • Protect Plasterboards from direct
produced from high purity natural • Length : Standard length is rain, sunlight or other extensive
gypsum core being sheeted in a 2400mm & 3000mm. Special weather conditions.
closely adhering best selected paper length is 1800mm to 4500mm • Mada Plus Plasterboards to be
liners. Mada Plus Fire Resistant
• Width : 1200mm & 1220mm. stored in dry area inside the
Plasterboard is lightweight for use in
building which is ready to receive
standard internal wall and ceiling • Thickness : 9.5mm, 12.5mm, drywall fixings.
applications where Fire protection is 15mm & 16mm.
required.
• Edge : Tapered, Square, Beveled & Material Packing Details
Field of Application Round.
Mada Plus Fire Resistant
Plasterboard used in Residential • Color : Pink / Grey Board Boards Per
Buildings, Commercial Buildings, • Fire Rating (Mada System Thickness Pallet
Hospitals, Airports, Educational application) - Tested as per
Institutions and other such ASTM E119 9.5 mm 90
applications. 12.5 mm 66
• Acoustic Rating (Mada System
Manufacturing Standard application) - Tested as per 15.0 mm 54
ASTM E90
Mada Plus Plasterboards are 16.0 mm 54
produced to ASTM C1396 / Technical Specification
C1396M Type X & EN 520 Type
I, F standards. Tested accordance
to ASTM E84 & ASTM 473 ASTM C473-06a Plaster Board Thickness (mm)
Parameters 9.5 12.5 15 16
Weight (kg / m2) +/- 0.2 8.4 11.1 13.6 14.5
Min Board Density (kg / m3) 884 888 906 906
Flame Spread Index Nil Nil Nil Nil
Smoke Developed Index Nil Nil Nil Nil
Asbestos (% by weight) Nil Nil Nil Nil
“MGC reserves the right to
Flexural Strength (N)(Ⱶ) >400 517 690 702
update technical parameters as
per its own discretion. For official Flexural Strength (N)(ǁ) >160 241 462 466
use of this TDS please consult
Nail Pull Resistance (N) >260 425 595 603
Mada Technical department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Light Weight Construction, Easy Material Storage &
& Fast Installation
Handling Conditions
• Good Fire Protection • Mada Plus Plasterboards to be
MADA PLUS FIRE & • Good Sound Insulation & Good stored on pallets or on a pack of
MOISTURE RESISTANT Thermal Insulation
“Part of Mada Plus Drywall System:
boards and supported evenly on a
firm, dry, level and structurally
PLASTERBOARD System performance warranty only sound floor. Load up to 4 pallets
of Plasterboards on each other.
by using the proposed Mada plus
Product Description
system products.” • Do not store any other material
on top of Plasterboards.
Mada Plus Plasterboards are Product Characteristics
produced from high purity natural • Protect Plasterboards from direct
gypsum core being sheeted in a • Length : Standard length is rain, sunlight or other extensive
closely adhering best selected paper 2400mm & 3000mm. Special weather conditions.
liners. Mada Plus Fire & Moisture length is 1800mm to 4500mm • Mada Plus Plasterboards to be
Resistant Plasterboard is lightweight stored in dry area inside the
• Width : 1200mm & 1220mm.
used for standard internal wall and building which is ready to receive
ceiling applications where Fire & • Thickness : 9.5mm, 12.5mm, drywall fixings.
Moisture Resistant properties are 15mm & 16mm.
required. • Edge : Tapered, Square, Beveled & Material Packing Details
Field of Application Round.
Mada Plus Fire & Moisture
• Color : Green / Grey Board Boards Per
Resistant Plasterboard used in
Residential Buildings, Commercial • Fire Rating (Mada System Thickness Pallet
Buildings, Hospitals, Airports, application) - Tested as per
Educational Institutions and other ASTM E119 9.5 mm 90
such applications. • Acoustic Rating (Mada System 12.5 mm 66
Manufacturing Standard application) - Tested as per 15.0 mm 54
ASTM E90
Mada Plus Plasterboards are 16.0 mm 54
produced to ASTM C1396 / Technical Specification
C1396M Type X & EN 520 Type
I, F & H1 standards. Tested
accordance to ASTM E84 & ASTM C473-06a Plaster Board Thickness (mm)
ASTM 473 Parameters 9.5 12.5 15 16
Weight (kg / m2) +/- 0.2 8.5 11.1 13.7 14.6
Min Board Density (kg / m3) 894 888 913 912
Flame Spread Index Nil Nil Nil Nil
Smoke Developed Index Nil Nil Nil Nil
Asbestos (% by weight) Nil Nil Nil Nil
“MGC reserves the right to
Flexural Strength (N)(Ⱶ) >400 644 742 776
update technical parameters as
per its own discretion. For official Flexural Strength (N)(ǁ) >160 270 462 475
use of this TDS please consult
Nail Pull Resistance (N) >260 414 422 443
Mada Technical department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | technical@madagypsum.com
TECHNICAL DATA SHEET
[METAL PROFILES & ACCESSORIES]
TECHNICAL DATA SHEET
Advantages
• Easy & Fast Installation Material Storage &
• High Adhesion Handling Conditions
• Low Consumption • Mada Render should be protected
from continuous exposure to
• Versatility of Usage
THIN COAT RENDER moisture. Prolonged or repeated
exposure to moisture may cause a
loss of strength. If storing on the
Product Characteristics concrete floor, wooden pallets have
to be used.
Product Description • Composition: Stucco & Adhesive • Mada Render can be mixed by hand
to improve adhesion to base or mechanically. Before mixing
Mada Thin Coat Render is a material.
perfect solution to create the thin please ensure that the mixing
surfaces perfectly suitable to apply • Usage: Internal walls & Ceilings at equipment and bucket being used
finishing on. The Thin Coat temperature > 5˚C. are clean. Contamination from
Render is a single layer, smooth- previous mixes adversely affect the
• Working Time: 60-90 mins setting time and strength.
coat render of grey-white color
intended for hand application in • Base Material for Application: • Add Mada Render to the water and
thickness of 3-6mm. Concrete, Porous Concrete, mix using hand or electric mixture.
Render. Allow the mixture to settle for 3-5
Field of Application • Thickness: 3-6mm mins. Check the consistency of the
Mada Thin Coat Render is best mixture and if the mixture is too
option to use for concrete or • Storage: 12 months approx.
thick then add slightly more water ,
porous concrete. Thin Coat
Material Packing Details conversely if the mixture is too
Render is used to prepare the wall liquid then add slightly more Render.
for the finishing items (paints, Mix Again and if necessary repeat
wallpapers, etc.). Thin Coat the process until the desired
Render is also perfect for repair Bags Per
Weight viscosity of the mixture is achieved
works. Pallet
for optimum application. .
40 Kg 36
Manufacturing Standards
Mada Renders are produced under a Technical Specification
quality system independently audited
and certified as conforming to ISO
9001:2010 Parameters
Color Grey-White
Mixing Ratio with Water 21.5 L of water per 40 Kg
pH Level 7
Tensile Strength ≥ 1.0 MPA
Compressive Stregth ≥ 2.5 MPA
“MGC reserves the right to update
Adhesive Strength ≥ 0.5 MPA
technical parameters as per its own
discretion. For official use of this TDS Diffusion Resistance Factor (µ) 10
please consult Mada Technical
Coverage Ratio 1 Kg / m2 / mm
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Easy & Fast Installation Material Storage &
• High Adhesion Handling Conditions
• Low Consumption • Mada Render should be protected
from continuous exposure to
HAND APPLIED • Versatility of Usage
moisture. Prolonged or repeated
RENDER exposure to moisture may cause a
loss of strength. If storing on the
Product Characteristics concrete floor, wooden pallets have
to be used.
Product Description • Composition: Stucco, Perlite, • Mada Render can be mixed by hand
Light weight fillers & Adhesive to or mechanically. Before mixing please
Mada Hand Applied Render is improve adhesion to base material.
your go to product for projects ensure that the mixing equipment and
that require versatile thicknesses • Usage: Internal walls & Ceilings at bucket being used are clean.
of Renders within small area. temperature > 5˚C. Contamination from previous mixes
Hand Applied Renders can be adversely affect the setting time and
• Working Time: 60-90 mins strength.
used for thickness ranging from 5-
30mm. • Base Material for Application: • Add Mada Render to the water and
Brickwork, Concrete, Porous mix using hand or electric mixture.
Concrete, Render. Allow the mixture to settle for 3-5
Field of Application • Thickness: 5-30mm mins. Check the consistency of the
Mada Hand Applied Render is the mixture and if the mixture is too
best option to use when surface • Storage: 12 months approx.
thick then add slightly more water ,
requires thickness, small areas of
Material Packing Details conversely if the mixture is too liquid
renders. Hand Applied Render is then add slightly more Render. Mix
primarily used for brick walls, Again and if necessary repeat the
concrete, stable mortar and other process until the desired viscosity of
concrete structures. Bags Per
Weight the mixture is achieved for optimum
Pallet
application. .
25 Kg 50
Manufacturing Standards
Mada Renders are produced under a Technical Specification
quality system independently audited
and certified as conforming to ISO
9001:2010 Parameters
Color Grey-White
Mixing Ratio with Water 10 L of water per 25 Kg
pH Level 7
Tensile Strength ≥ 1.0 MPA
Compressive Stregth ≥ 2.5 MPA
“MGC reserves the right to update
Adhesive Strength ≥ 0.5 MPA
technical parameters as per its own
discretion. For official use of this TDS Diffusion Resistance Factor (µ) 10
please consult Mada Technical
Coverage Ratio 1 Kg / m2 / mm
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Easy & Fast Installation Material Storage &
• High Adhesion Handling Conditions
• Low Consumption • Mada Render should be protected
from continuous exposure to
MACHINE APPLIED • Versatility of Usage
moisture. Prolonged or repeated
exposure to moisture may cause a
RENDER Product Characteristics
loss of strength. If storing on the
concrete floor, wooden pallets have
to be used.
Product Description • Composition: Stucco, Lime, Sand, • Mada Render can be mixed by hand
Perlite & Adhesive to improve or mechanically. Before mixing
Mada Machine Applied Render is adhesion to base material.
our solution for covering big areas please ensure that the mixing
using regular plastering machine. • Usage: Internal walls & Ceilings at equipment and bucket being used
The machine render is designed to temperature > 5˚C. are clean. Contamination from
have a higher application period as previous mixes adversely affect the
• Working Time: 120-150 mins setting time and strength.
compared to a Hand Applied
Render. • Base Material for Application: • Add Mada Render to the water and
Concrete, Porous Concrete, mix using hand or electric mixture.
Field of Application Render. Allow the mixture to settle for 3-5
Mada Machine Applied Render is • Thickness: > 6mm mins. Check the consistency of the
used when designated area is big mixture and if the mixture is too
• Storage: 12 months approx.
and thickness required exceed thick then add slightly more water ,
6mm. best option to use for Material Packing Details conversely if the mixture is too
concrete or porous concrete. liquid then add slightly more Render.
Machine Applied Render is Mix Again and if necessary repeat
primarily used for brick walls, the process until the desired
Bags Per
concrete, stable mortar and other Weight viscosity of the mixture is achieved
Pallet
concrete structures. for optimum application. .
40 Kg 36
Manufacturing Standards
Mada Renders are produced under a Technical Specification
quality system independently audited
and certified as conforming to ISO
9001:2010 Parameters
Color Grey-White
Mixing Ratio with Water 20 L of water per 40 Kg
pH Level 7
Tensile Strength ≥ 1.0 MPA
Compressive Stregth ≥ 2.5 MPA
“MGC reserves the right to update
Adhesive Strength ≥ 0.5 MPA
technical parameters as per its own
discretion. For official use of this TDS Diffusion Resistance Factor (µ) 10
please consult Mada Technical
Coverage Ratio 1 Kg / m2 / mm
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Easy & Fast Application Material Storage &
• Low Consumption Handling Conditions
• Versatility of Usage • Mada Standard Plaster should be
protected from continuous exposure
STANDARD to moisture. Prolonged or repeated
exposure to moisture may cause a
PLASTER Product Characteristics
loss of strength. If storing on the
concrete floor, wooden pallets have
to be used.
Product Description • Environmental & Healthy: • Mada Standard Plaster can be mixed
Mada Standard Plaster is gypsum • Simple mixing and application by hand or mechanically. Before
molding powder product for process mixing please ensure that the mixing
interiors. The powder product will equipment and bucket being used
• Usage on all conventional surface are clean. Contamination from
be mixed with water according to
specifications. • Create a smooth surface previous mixes adversely affect the
setting time and strength.
• Are an appropriate basis under
different surface treatment (paint, • Add Mada Standard Plaster to the
wallpaper, tiles etc.). water and mix using hand or electric
mixture. Allow the mixture to settle
Field of Application for 3-5 mins. Check the consistency
Mada Standard Plaster is a molding of the mixture and if the mixture is
powder product for interiors use only. Material Packing Details
too thick then add slightly more
It is designed for molding of water , conversely if the mixture is
decorations, cornices, repair works too liquid then add slightly more
and for modeling. Bags Per Plaster. Mix Again and if necessary
Weight
Pallet repeat the process until the desired
viscosity of the mixture is achieved
25 Kg 50
for optimum application. .
40 Kg 33
Manufacturing Standards
Mada Standard Plaster is produced
under a quality system independently
audited and certified as conforming to
ISO 9001:2010
Technical Specification
Parameters
Color White / Off White
Mixing Ratio with Water 20 L of water per 25 Kg bag
32 L of water per 40 Kg bag
“MGC reserves the right to update Workability 5 mins approx.
technical parameters as per its own
Final Set Time 21 mins approx.
discretion. For official use of this TDS
please consult Mada Technical
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Easy & Fast Application Material Storage &
• Low Consumption Handling Conditions
• Versatility of Usage • Mada Molding French Plaster should
be protected from continuous
MOLDING FRENCH exposure to moisture. Prolonged or
repeated exposure to moisture may
PLASTER Product Characteristics
cause a loss of strength. If storing on
the concrete floor, wooden pallets
have to be used.
Product Description • Environmental & Healthy: • Mada Molding French Plaster can be
Mada Molding French Plaster is a • Simple mixing and application mixed by hand or mechanically.
premium gypsum molding powder process Before mixing please ensure that the
product for interiors. The powder mixing equipment and bucket being
• Usage on all conventional surface used are clean. Contamination from
product will be mixed with water
according to specifications. • Create a smooth surface previous mixes adversely affect the
setting time and strength.
• Are an appropriate basis under
different surface treatment (paint, • Add Mada Molding French Plaster to
wallpaper, tiles etc.). the water and mix using hand or
electric mixture. Allow the mixture to
Field of Application settle for 3-5 mins. Check the
Mada Molding French Plaster is a consistency of the mixture and if the
molding powder product for interiors mixture is too thick then add slightly
use only. It is designed for molding Material Packing Details more water , conversely if the
of decorations, cornices, repair works mixture is too liquid then add slightly
and for modeling. more Plaster. Mix Again and if
necessary repeat the process until the
Bags Per
Weight desired viscosity of the mixture is
Pallet
achieved for optimum application. .
40 Kg 33
Manufacturing Standards
Mada Molding French Plaster is
produced under a quality system
independently audited and certified as
conforming to ISO 9001:2010
Technical Specification
Parameters
Color White
Mixing Ratio with Water 32 L of water per 40 Kg bag
Workability 5 mins approx.
“MGC reserves the right to update
technical parameters as per its own Final Set Time 21 mins approx.
discretion. For official use of this TDS
please consult Mada Technical
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Easy & Fast Application Material Storage &
• Low Consumption Handling Conditions
• Versatility of Usage • Mada French Adhesive should be
protected from continuous exposure
MADA FRENCH to moisture. Prolonged or repeated
exposure to moisture may cause a
ADHESIVE Product Characteristics
loss of strength. If storing on the
concrete floor, wooden pallets have
to be used.
Product Description • Environmental & Healthy: • Mada French Adhesive can be mixed
Mada FRENCH ADHESIVE is a • Simple mixing and application by hand or mechanically. Before
special gypsum product for interiors process mixing please ensure that the mixing
and exteriors. The powder product equipment and bucket being used are
• Usage on all conventional surface clean. Contamination from previous
will be mixed with water according to
specifications. mixes adversely affect the setting time
and strength.
• Add Mada French Adhesive to the
water and mix using hand or electric
Field of Application mixture. Allow the mixture to settle
Mada French Adhesive is used for for 3-5 mins. Check the consistency
adhering of decorations and cornices of the mixture and if the mixture is
to the wall and for cladded walls, too thick then add slightly more water
where gypsum boards are glued to Material Packing Details , conversely if the mixture is too
the walls. liquid then add slightly more Plaster.
Mix Again and if necessary repeat the
process until the desired viscosity of
Bags Per
Weight the mixture is achieved for optimum
Pallet
application. .
25 Kg 50
Manufacturing Standards
Mada French Adhesive is produced
under a quality system independently
audited and certified as conforming to
ISO 9001:2010
Technical Specification
Parameters
Color White / Off White
Mixing Ratio with Water 20 L of water per 25 Kg bag
Workability 60 mins approx.
“MGC reserves the right to update
technical parameters as per its own Final Set Time 90 mins approx.
discretion. For official use of this TDS Bonding Strength > 1.5 N/mm2
please consult Mada Technical
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Light Weight Construction
• Easy & Fast Installation Material Storage &
• Good Fire Protection Handling Conditions
• Good Sound Insulation
MADA WALL STUD • Environment Friendly
• Products are supplied in pack and
sub–pack quantities and should be
(C-STUD) “Part of Mada Plus Drywall System:
handled in accordance with the
recommendations contained in AS
System performance warranty only
1470 – Health and Safety at Work
by using the proposed Mada plus Principles and Practice..
Product Description system products.”
• Where mechanical lifting or
Mada Wall Studs fabricated from Product Characteristics moving equipment is required,
Cold rolled galvanized steel are trained and licensed operators are
used as the vertical member of the to be used.
Technical
partition. system with a friction fit Detail • Metal products should be stored
Parameters
between the bottom and top in an environmentally–friendly
tracks. Mada studs features knurled Z120, Z180 & area away from airborne
Coating
faces and reinforcing ribs along the Z275 contaminants such as acid and salt
stud design. The ribs provide Yield sprays.
added strength, are less prone to 240MPa - 310MPa
Strength • People with sensitive skin
twist and creating "high-shoulders"
when finishing gypsum board. Tensile conditions should seek medical
340MPa - 420MPa advice before prolonged handling
Strength
of metal products; hands should
Field of Application Material Galvanized Steel be washed before eating and for
Applicable for Partition system, personal hygiene.
32/32, 34/34,
Liner System, Stud ceiling system
Flanges (mm) 36/36, 32/34 & • Non–fogging goggles (AS/NZS
and other such applications.
34/36 1336) should be worn when
Manufacturing Standards cutting metal sections.
Lip (mm) 4.5, 5.0, 5.5 & 6.0
General Note
“MGC reserves the right to update
The products should not be used
technical parameters as per its own for purposes other than those
discretion. For official use of this TDS shown on the Mada Technical
please consult Mada Technical Proposal.
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
112-113_HIT_M.qxd 25/11/05 10:18 Page 112
SPIT HIT M
SPIT HIT M - A4
¬ Hammer-set anchor for light duty fixing for
concrete and all materials types
N° PX 1058
Technical data
L SPIT Embedment Maximum Minimum Drilling Drilling Drilling Cylinder Total Type
hnom HIT M depth thickness thickness depth depth diameter head anchor of
of part to of base in base forward diameter length nail
be fixed in material material the part to Code
concrete be fixed Zinc Stainless
d0 (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) - coated steel
hnom tfix (1) hmin h0 L+8 d0 dc L - steel nail A4 nail
dc 5-5/27P 5 35 27 050116
20 60 30 5 9 PZ2
h0 tfix 5-15/37P 15 45 37 050117
L+8 6-5/32P 5 40 32 050118 050157
6-12/39P 12 47 39 050119
6-25/52P 25 25 65 35 60 6 11 52 PZ2 050121 050158
6-40/67P 40 75 67 050122 050159
6-12/39V 12 47 39 050129
APPLICATION 6-25/52V 25 25 65 35 60 6 10 52 PZ2 050131
6-40/67V 40 75 67 050132
¬ Insulation cladding 6/5-M6 - - 32 M6 050141
30 65 40 6 11
6/5-M7 - - 32 M7 050142
¬ Profiles for thin coat external
8-10/42P 10 50 42 050123 050161
¬ Insulation systems 8-30/62P 30 70 62 050124 050162
¬ Drywall track 8-60/92P 30 60 65 40 100 8 13 92 PZ2 050125 050163
¬ Wood 8-80/112P 80 120 112 050126
8-100/132P 100 140 132 050127
¬ Flashing 8-30/62V 30 70 62 050134
¬ Electrical accessories 8-60/92V 60 100 92 050135
8-80/112V 30 80 65 40 120 8 11,5 112 PZ2 050136
¬ Collar (Atlas …)
8-100/132V 100 140 132 050137
¬…
(1) In masonry, the thickness of part to be fixed could be fluctuate to ± 5 mm from tfix for Ø5 et 6 mm, and to ± 10 mm for
Ø8 mm, to ensure a good contact between collar and the part to be fixed.
SPIT HIT M
SPIT HIT M - A4
Design loads (NRd, VRd) and Recommended loads (Nrec, Vrec)
for one anchor without edge or spacing influence
TENSILE IN kN SHEAR IN kN
NRec 0,04 0,04 0,05 VRec 0,04 0,04 0,04 0,09 0,05
Plasterboard type BA10 + polystyren
NRd 0,07 0,07 0,08 VRd 0,07 0,07 0,07 0,27 0,08
NRec 0,05 0,05 0,06 VRec 0,05 0,05 0,05 0,19 0,06
Spacing data
IN CONCRETE
SPIT HIT M Minimum distance between anchors and from edges (mm)
Ccr,N mini Ccr,V mini Scr,1 mini Scr,2 mini
without edge influence near one edge
5/5 ; 5/15 25 40 25 60
6/5 ; 6/12 ; 6/25 ; 6/40 25 45 25 70
8/10 ; 8/30 ; 8/60 ; 8/80 ; 8/100 25 60 25 90
113
TECHNICAL DATA SHEET
Advantages
• The additional bearing forces
provided by a wider head mean Material Storage &
fewer screws are required
Handling Conditions
• Excellent choice for general
MADA WAFER HEAD purpose, light-to-medium-duty
• Mechanical handling – The
use
SELF DRILLING • #2 Phillips point reduces the risk
dimensions of the packaging /
pallet vary depending upon the
SCREW of cam-out product size. To avoid potentially
overloading a lift truck, it is
important that any effect on load
Product Description “Part of Mada Plus Drywall System: centres is considered.
System performance warranty only
Wafer Head self drilling screws • Manual handling – Screws are
by using the proposed Mada plus supplied in a variety of lengths
with a head diameter of 11mm are
system products.” and the weight of these varies
designed for assembling steel
framing components for up to slightly. Puncture resistant gloves
3.0mm thick. Product Characteristics should be used when handling
screws.
General Note
“MGC reserves the right to update
The products should not be used
technical parameters as per its own
for purposes other than those
discretion. For official use of this TDS shown on the Mada Technical
please consult Mada Technical Proposal.
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Designed specifically for use in
drywall Material Storage &
• Distributes bearing stress over a Handling Conditions
wider area than flat heads
Case Minimum
Mada Drywall Screws comply to
Hardness Rockwell C44
ASTM C1002 Installation Guidelines
M3.5 x 25
M3.5 x 30
• Overdriving may result in failure of
M3.5 x 35
the fastener or stripout of the work
Sizes (mm) M3.5 x 45
surface.
M3.5 x 55
M3.5 x 60 • The Bugle head to be fully seated
M4.2 x 70 when the head is flush with the
work surface.
Packing 1000Pcs/Box
General Note
“MGC reserves the right to update
The products should not be used
technical parameters as per its own
for purposes other than those
discretion. For official use of this TDS shown on the Mada Technical
please consult Mada Technical Proposal.
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Light in weight
• Easy & Fast Installation Material Storage &
• Economical Handling Conditions
MADA SLOTTED “Part of Mada Plus Drywall System:
System performance warranty only • Products are supplied in pack and
L-BRACKET WITH by using the proposed Mada plus sub–pack quantities and should be
handled in accordance with the
system products.”
MINI HOLES Product Characteristics
recommendations contained in AS
1470 – Health and Safety at Work
Product Description Principles and Practice..
General Note
“MGC reserves the right to update
The products should not be used
technical parameters as per its own for purposes other than those
discretion. For official use of this TDS shown on the Mada Technical
please consult Mada Technical Proposal.
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Ready to be used directly from
the bucket Material Storage &
• Creamy and smooth consistency Handling Conditions
• Outstanding slip and bond • Keep containers closed when not
MADA MULTIUSE • Joint finishing is fast, easy, and
in use. Minimize generation of
dust. Avoid inhalation of dust and
JOINTING smooth, reducing work efforts
contact with an eyes and skin.
and improving appearance and
COMPOUND quality of the job • Wear recommended personal
protective equipment when
• Easy workability, Easy filling, Fast
Product Description drying, Easy to sand
handling..
• Use good safety and industrial
Mada Gypsum Multi use Jointing hygiene practices.
Compound is a ready mix calcium “Part of Mada Plus Drywall System:
carbonate based joint filler with System performance warranty only • Store at room temperature in a dry
vinyl binders and high value by using the proposed Mada plus location, keep product out of
additives which provides superior direct sunlight at all times.
system products.”
performance compared to ordinary • Do not freeze.
ready mixed products..
Product Characteristics • Ecotoxicological Information -
This product has no known
Field of Application adverse effect on the ecology. A
Proper concealment (joints, large discharge directly into
fasteners, trims) of drywall Technical waterways would not be expected
Detail
partition & ceiling systems.. Parameters to kill aquatic life.
Density
1.74
(kg/ltr) Installation Guidelines
Type Ready mix
Manufacturing When taping and finishing joint,
Hand or thinning with water may improve
Standards Use mechanical tool application. Add clean water in
application half-pint increments, remix and
Mada’s Multi use Jointing compound trial apply until preferred
Humidity
comply to ASTM C475 Standard 95% RH consistency is reached. Over-
Resistance
Specification for Joint Compound dilution causes abnormal
for finishing gypsum board. Light shrinkage, poor bond and other
0.75
Reflection negative effects. Do not mix with
9 Months under any other material.
Shelf life proper storage
conditions
Packing 28kg/Bucket
General Note
“MGC reserves the right to update
The products should not be used
technical parameters as per its own for purposes other than those
discretion. For official use of this TDS shown on the Mada Technical
please consult Mada Technical Proposal.
department”
0
Copyrights © Mada Gypsum Company. All Rights Reserved | Saudi Arabia | Tel: (00966) 14 325 3253 | Fax: +966 14 325 0420 | Technical@madagypsum.com
TECHNICAL DATA SHEET
Advantages
• Odorless, Paintable
• Easy to apply. Product Specification
• Good water & Chemical resistant
Technical
MADA FIRE GUARD • Flexible and compressible
Parameters
Detail
Fire Rating
S.No Partition Description
[ASTM E119]
Double Layer Of 12.5mm Mada Plus Plasterboards On Both Sides Of
1 1 Hour
Single Stud Frame
Double Layer Of 12.5mm Mada Plus Plasterboards On Both Sides Of Single
2 2 Hour
Stud Frame
Single Layer Of 15mm Mada Plus Plasterboards On Both Sides Of Single
3 1 Hour
Stud Frame
Double Layer Of 12.5mm Mada Cement Boards On Both Sides Of Single
4 90 Minutes
Stud Frame
Single Layer Of 15mm Mada Cement Board On Both Sides Of Single Stud
5 1 Hour
Frame
Single Layer Of 15mm Mada Cement Board On Both Sides Of Single Stud
6 45 Minutes
Frame
Single Layer Of 15mm Mada Plus Plasterboards On One Side & Single
7 Layer Of 25mm Mada Plus Shaft Board On Other Side Of Single CH-Stud 1 Hour
Frame
Double Layer Of 15mm Mada Plus Plasterboards On One Side & Single
8 Layer Of 25mm Mada Plus Shaft Board On Other Side Of Single CH-Stud 2 Hour
Frame
Three Layer Of 15mm Mada Plus Plasterboards On Both Sides Of Single
9 3 Hour
Stud Frame
Single Layer Of 12.5mm Mada Plus Plasterboards On Both Sides Of Single
10 45 Minutes
Stud Frame
* Complete test report/certification will be provided on request
* Mada PLUS plasterboards are manufactured only for projects and are not available in the retail market.
* Mada PLUS plasterboard is produced with an enhanced configuration (extra fibers, special additives, higher specification of paper liners, controlled density, etc)
so that the performance is guaranteed
* Mada PLUS plasterboard is not available to purchase without purchasing a full system (Mada PLUS System) from Mada Gypsum
* Mada PLUS systems are tested & certified with Intertek for fire ratings as per ASTM E119.
* The performance of all Mada PLUS Systems rely on using the nominated MGC components. Use of non-MGC approved components will reduce a systems fire
rating, acoustic rating, appearance or other aspects of performance. This also includes invalidating any system warranty and previously submitted systems for
consultant approval
AbdulRaheem Sultan
[Technical Manager]
SYSTEM TEST REPORT
[ACOUSTIC TEST REPORT]
Acoustic Test Report Result Summerized
Acoustic STC
S.No. Mada PLUS System Cavity Insulaiton
laboratory [ASTM E90]
1 1x12.5mm Mada Plus Regular plasterboard on both sides of Mada C-stud UL 40
1x15mm Mada Plus Fire Resistant Plasterboard on one side and 1x25mm Mada Shaft board on shaft side of
2 UL 46
Mada CH-stud
3 1x15mm Mada Plus Fire Resistant Plasterboard on both sides of Mada C-stud UL 47
1x15mm Mada Plus Fire Resistant Plasterboard on both sides with resilient channel on one side of Mada C-
4 UL 49
stud
5 2x12.5mm Mada Plus Regular plasterboard on both sides of Mada C-stud UL 51
6 2x12.5mm Mada Plus Fire Resistant Plasterboard on both sides of Mada C-stud UL 52
1 Row x 50mm Mada
2x15mm Mada Plus Fire Resistant Plasterboard on one side and 1x25mm Mada Shaft board on shaft side of
8 UL 52 Approved Glasswool
Mada CH-stud
Insulation 16kg/m3
9 1x15mm Mada ProCem Cement Board on both sides of Mada C-stud UL 53
11 2x15mm Mada plus Fire Resistant plasterboard on either side of double(chase wall) C-stud UL 58
2x15mm Mada Plus Fire Resistant Plasterboard on both sides with resilient channel on one side of Mada C-
12 UL 59
stud
13 2x16mm Mada Plus Fire Resistant Plasterboard on both sides of Mada C-stud DARL 57
1 x 16mm Mada Plus Fire Resistant board one side and 1 x 15mm Mada ProCem Cement board on other side
15 DARL 61
of Twin Stud without Bridging (350mm total width of partition)
1x15mm Mada Plus Regular Plasterboard on one side and 1x15mm Mada Plus Impact Resistant Plasterboard
7 Exova 52 1 Row x 75mm Mada
on one side of Mada C-stud
Approved Rockwool
2x15mm Mada Plus Fire Resistant Plasterboard on one side and 1x15mm Mada Impact Resistant Plasterboard
10 Exova 56 Insulation 40kg/m3
on one side of single C-stud
2 x 16mm Mada Plus Fire Resistant board one side and 1 x 12mm Mada Fiber Cement board on other side of
16 DARL 79
Twin Stud without Bridging (350mm total width of partition)
3 x 16mm Mada Plus Fire Resistant board one side and 1 x 12mm Mada Fiber Cement board on other side of
17 DARL 78
Twin Stud without Bridging (450mm total width of partition)
2 x 16mm Mada Plus Fire Resistant plasterboards (either sides) of Twin Stud without Bridging (350mm total
18 DARL 70
width of partition)
2 x 16mm Mada Plus Fire Resistant plasterboards (either sides) of Twin Stud without Bridging (300mm total
19 DARL 68
width of partition)
2 Row x 75mm Mada
2 x 16mm Mada Plus Fire Resistant plasterboards (either sides) of Twin Stud (200mm total width of partition) -
20 DARL 63 Approved Glasswool
Without brace
Insulation 24kg/m3
2 x 16mm Mada Plus Fire Resistant plasterboards (either sides) of Twin Stud (200mm total width of partition) -
21 DARL 59
With rigid brace
1 x 16mm Mada Plus Fire Resistant board one side a+ 1 x 15mm Mada ProCem Cement board (either sides) of
22 DARL 64
Twin Stud (200mm total width of partition) - With acoustic v-brace
3 x 16mm Mada Plus Fire Resistant plasterboards (either sides) of Twin Stud without Bridging (450mm total
23 DARL 72
width of partition)
3 x 16mm Mada Plus Fire Resistant plasterboards (either sides) of Twin Stud with Bridging (450mm total width
24 DARL 72
of partition)
3 x 16mm Mada Plus Fire Resistant plasterboards (One side) of Single Stud Frame (118mm total width of Liner 1 Row x 75mm Mada
25 System) DARL 45 Approved Glasswool
Insulation 24kg/m3
MATERIAL TEST REPORT
TEST REPORTS
[JOINTING TAPE]
TEST REPORTS
[JOINTING COMPOUND]
BLUE LABEL CO.,LTD.
48/58 Moo.1 Ekachai Road, Khok-Krabue, Amphur Muang, Samutsakhon, 74000 Thailand
Tel : +66 3449 4774-5 Fax : +66 3449 4776 Website : www.bluelabelgroup.com
Theme : Check film properties of RHINOZ Cement Plaster Base. Report No. : LTR-160222
Reported by : Phitchaya Approved by : Sombat
The data shown are based on laboratory tests only. Actual measured data may vary due to circumstances beyond our control
Page 1 of 1
PAGE
INSTALLATION 1/2
INSTALLATION
1. 2.
Apply SC032 3D Concrete Bonding on the surface and Mix RF103 RHINOZ Cement Plaster Base, Part A:B by
leave it dry 30-60 min. until color of concrete bonding 3:1 of weight ratio with mixing machine tool. (speed
changed from milky white to be transparent color. 300-500 rpm.) until homogeneous compound
3. 4.
Apply RF103 RHINOZ Cement Plaster Base on the Put AB001 RHINOZ Fiberglass Mesh Tape on the joint,
jointing with trowel only 1 layer, width 10 cm. and thick- and press fiber mess tape to stick on jointing compound
ness 1 mm. while its still wet.
PAGE
INSTALLATION 2/2
5. 6.
INSTALLATION
Apply RF103 RHINOZ Cement Plaster Base to cover on Apply 2nd layer of RF103 RHINOZ Cement Plaster Base
the AB001 RHINOZ Fiberglass Mesh Tape only 1 layer, to cover 1st layer, width 20 cm., thin layer and leave dry
and leave dry 1-2 hr. 1-2 hr.
7. 8.
Apply 3rd layer of RF103 RHINOZ Cement Plaster Base Leave completely dry, at less 10-16 hr.
to cover 2nd layer, width 30 cm.
9. 10.
Sanding the surface wall with sandpaper NO.80-120 or Clean with cloth to remove all dust before painting.
sander machine.
1 Kingdom Tower, Jeddah Kingdom Holding Company Dar Al Handasah Shair & Partners Saudi Bin Ladin Group ABCD Jeddah
2 SANG Hospital [Taif Region] National Guard Health Affairs Dar Al Handasah Shair & Partners Nesma & Partners Contracting Company Taif
3 Sail Tower Project AMIAS Dress & Sommer Al Saad General Contracting - BESIX Saudi - JV Jeddah
Ministry of Interiors,
5 Ministry Of Interiors, KSA Saudi Oger Jeddah
KAP 1/181/Dhahban, KSA
6 Abraj kudai project Abraj kudai Dar Al Handasah Shair & Partners Saudi Bin Ladin Group ABCD Makkah
9 Mental Health Hospital Dar Al Handasah Shair & Partners Saudi Bin Ladin Group KSA
10 Saudi Aviation Flight Acadimy Aviation Sciences Company Limited Dar Al Handasah Shair & Partners UCTC Riyadh
11 Procare Riaya Hospital Expansion Procare Riaya Hospital Otaishan Consulting Engineers PBC - Project Build General Contracting Co. Ltd Dammam
12 Faby Land, Deerfield Project Abdulla Al Othaim Helpdesk Technical Abu Dhabi
14 MOH Maternity and Child Hospital Ministry of Health Fourth Dimension Dreshak International Iraq
15 The Baron Hotel Mumtaz Muslim Dar Al Handasah Shair & Partners Dreshak International Iraq
16 Jumeirah Park Villas, Package 5A Jumeirah Park Dar Al Handasah Shair & Partners Arabtech Construction LLC Dubai
17 Strategic Unified Project Ministry of Interior Integrated Project Dar Al Riyadh Consultant Engineers Saudi Bin Ladin Group ABCD KSA
APPROVED PROJECTS
S.No. PROJECT NAME CLIENT CONSULTANT CONTRACTOR CITY
18 SABIC Plastics Applications Development Center SABIC Zuhair Fayez Partnership EL-SEIF SABIC KSA
19 KKU Medical City Male Campus Phase2 KKU Medical City Male Campus Phase2 Zuhair Fayez Partnership Saudi Arabian Baytur KSA
26 King Saud University for Health Science National Guards Dar Al Handasah Shair & Partners Saudi Bin Ladin Group ABCD Riyadh/Jeddah
30 King Saud University in Riyadh - Women's Educational Facilities King Saud University Saudi Consulting Services (Saud Consult) Saudi Bin Ladin Group PBAD Riyadh
35 The Headquarters Business Park in Jeddah Al-Dar Al-Khasa for Urban Development Dr. Jafar Al Sabbagh Office Freyssinet Saudi Arabia Co. LTD Jeddah
Al Qussi International
Seat Group for const. and Dev.
Bong Kyung Const. Co.
King Abdulazez University, Ministry of Zuhair Fayez Partnership Consultants / Al Muhaideb Contracting Co.
36 King Abdul-Aziz University – Many Projects Jeddah
Higher Education FLUOR Arabia Limited Haif Cont. Co.
Al-Saad General Contracting.
ABV Saudi.
Rafic A. Kreidie Engineers and Contractors.
42 Emergency Accommodation Center in Alshmisy Ministry of Finance Dar Al Handasah Shair & Partners Saudi Bin Ladin Group PBAD Makkah
43 King Faisal Medical City in Taif Ministry of Health Dar Al-Magd Consultant. Al Majal Al Arabi Group Taif
APPROVED PROJECTS
S.No. PROJECT NAME CLIENT CONSULTANT CONTRACTOR CITY
King Abdullah Endowment for His
44 King Abdullah Endowment for His Parents Omrania & Associates (O&A), Saudi Arabia Saudi Oger, Riyadh Madina
Parents
48 King Abdul-Aziz Center for Knowledge and Culture Saudi Aramco Saudi Consulting Services (Saud Consult) Saudi Oger Ltd Dhran