Turnkey solutions for


disinfection measurement
Reagent-less systems for free or
total chlorine measurement
2

Disinfection Measurement Systems


Free or Total Chlorine measurement systems eliminate reagents by using
EPA recognized amperometric sensor technology

Complete panel solutions for Free or Total Chlorine analog outputs or a model CM444 transmitter with two
sensor inputs and two analog outputs. Systems are also
• A selection of systems for free chlorine or available with EtherNet/IP digital communications with the
total chlorine measurement model CM444 transmitter.
• Reagent-less systems using amperometric
sensor technology A disinfection expansion panel is also available to add
• Accurate measurement with a choice of sensor additional disinfection sensor measurements to an existing
measurement ranges system, without the need for an additional transmitter.
• EPA compliant free chlorine systems according to Sensors installed in a disinfection expansion panel are
Method 334.0 simply connected to a CM444 transmitter on an existing
• Free chlorine systems include pH compensation to system, thereby leveraging the transmitter across multiple
ensure proper hypochlorous acid measurement and disinfection measurement points.
accurate DPD verification
• Easy DPD verification with built-in test valve All free chlorine panels are EPA compliant according to
• Inlet and outlet valves allow for easy installation and Method 334.0, which recognizes both reagent-based
isolation for routine sensor maintenance systems or amperometric measurement systems for online
• An expansion panel facilitates the installation of free chlorine analysis. The disinfection systems accomplish
additional disinfection sensors, while leveraging the chlorine analysis using amperometric sensor technology,
transmitter from an existing system eliminating the need for costly reagents or the maintenance
reagent-based systems require. These systems are ideally
Integrated flow assembly and pressure regulation suited for applications in drinking water, industrial water
or power.
• Integrated flow cell is designed to properly hold both the
chlorine and pH probes System Design
• Built in needle valve for flow control between
30 and 120 L/hr A disinfection panel is comprised of a Liquiline transmitter,
• An integral inductive switch activates an alarm when either the CM442 or CM444 and an amperometric chlorine
flow is too low for proper measurement sensor, either free or total. The chlorine sensor mounts in
• Constant pressure is maintained in the flow assembly the integral flow assembly (Flowfit CCA250), and with free
thanks to an integral pressure regulator chlorine systems a pH sensor is also included to install in the
flow assembly. All panels include an integral flow switch
Liquiline and Memosens® technology mounted in the flow assembly to monitor for proper sample
stream flow. The flow switch provides an alarm through the
• Plug-and-play Memosens digital sensors eliminate transmitter if flow is interrupted. Each free chlorine or total
problems associated with analog sensor technology chlorine system includes sensor cables and system tubing is
• Liquiline transmitter in two or four channel versions with -inch stainless steel. An integral lead-free pressure
a flexible range of I/O simplifies control system integration regulator sets system pressure to 15 PSI. Components on a
• Optional Memobase Plus hardware and software main system are installed on a 20 × 20-inch stainless steel
enables remote calibration and intelligent lifecycle panel, and a 20 × 12 inches extention panel, with -inch ID
sensor management mounting holes, that is ready to be mounted to a secure
vertical surface. Stainless steel inlet and outlet shut off
Each disinfection analysis system is designed to provide a valves, with ½-inch female NPT fittings, allow for system
turnkey panel-mounted solution for free or total chlorine isolation during routine sensor maintenance. A separate
measurement. Each complete panel system incorporates a ¼-inch sample valve allows for ease of performing a DPD
Memosens amperometric chlorine sensor. Free chlorine verification test without interrupting system measurement.
systems include a Memosens pH probe for accurate and
reliable hypochlorous acid disinfection measurement. Each The transmitter has a NEMA 4X (IP66) rating and all
panel is equipped with a Liquiline transmitter, either a other components are water-proof, for installation indoors,
model CM442 with two sensor input channels and two outdoors or in an enclosure.
3

Dimensions
20.000
19.000
7.150 .500 .500

10.405

19.000

20.000

3/8" Mounting
1/2" FNPT (x2) 1/4" Outlet
Holes (x4)
Free and total chlorine disinfection measurement systems

20.00 20.00
.50 19.00 19.00
3.94 3.94.50 .50 .50

11.00 11.00

12.00 12.00

3/8" Mounting
1/2" FNPT (x2) 1/4" Outlet
Holes (x4)
Disinfection measurement expansion panel

System Components

Liquiline CM442 or CM444* transmitter: Memosens total chlorine


• CM442-CAM2A2FD11A: CSA C/US sensor – CCS120D:
General purpose, two sensor inputs, • CCS120D-AA21AE:
two analog outputs with HART, two discrete 0.1 to 10 mg/L, non-hazardous
inputs and outputs, 100 to 230 VAC, or,
• CM444-CAM21A1FG11BAA: CSA C/US Memosens pH sensor – CPS31D:
General purpose, two sensor inputs, • CPS31D-7AC21: Basic, 1-12 pH,
two analog outputs with HART, two discrete 120 mm, non-hazardous
inputs and outputs, 100 to 230 VAC, or,
• CM444-CAM2DA1FG11BAA: CSA C/US Memosens measurement cable:
General purpose, two sensor inputs, • CYK10-A881: Non-hazardous,
Ethernet IP with two analog outputs, 1 m, wire terminals
two discrete inputs and outputs,
100 to 230 VAC Flowfit CCA250 flow assembly:
• CCA250-M1: NPT process
Memosens free chlorine sensor – CCS51D adaptor with proximity switch
(range dependent): • Pressure regulator with gauge:
• CCS51D-AA11AD-NC: Lead-free, 0-30 PSIG,15 PSIG
0 to 5 mg/L, non-hazardous nominal operating pressure
• CCS51D-AA11BF-NC: • Inlet and outlet valves: 316 SS
0 to 20 mg/L, non-hazardous ball valve, ½-inch NPT fitting
• CCS51D-AA11CJ-NC: • DPD test valve: 316 SS toggle
0 to 200 mg/L, non-hazardous valve, ¼-inch

*
Accommodates up to eight additional sensor inputs and other optional outputs that are ordered separately.
Material Numbers

Material Number Transmitter Description


71367911 Liquiline CM442 Free Chlorine Analysis System complete with Liquiline CM442 transmitter,
0 to 5 mg/L chlorine range, compliant to EPA Method 334.0
71367912 Liquiline CM444 Free Chlorine Analysis System complete with Liquiline CM444 transmitter,
0 to 5 mg/L chlorine range, compliant to EPA Method 334.0
71502871 Liquiline CM444 Free Chlorine Analysis System complete with Liquiline CM444 transmitter
with EtherNet/IP communications, 0 to 5 mg/L chlorine range, compliant to
EPA Method 334.0
71337195 Liquiline CM442 Free Chlorine Analysis System complete with Liquiline CM442 transmitter,
0 to 20 mg/L chlorine range, compliant to EPA Method 334.0
71337196 Liquiline CM444 Free Chlorine Analysis System complete with Liquiline CM444 transmitter,
0 to 20 mg/L chlorine range, compliant to EPA Method 334.0
71502872 Liquiline CM444 Free Chlorine Analysis System complete with Liquiline CM444 transmitter
with EtherNet/IP communications, 0 to 20 mg/L chlorine range, compliant to
EPA Method 334.0
71452648 Liquiline CM442 Free Chlorine Analysis System complete with Liquiline CM442 transmitter,
0 to 200 mg/L chlorine range, compliant to EPA Method 334.0
71454792 Liquiline CM444 Free Chlorine Analysis System complete with Liquiline CM444 transmitter,
0 to 200 mg/L chlorine range, compliant to EPA Method 334.0
71464226 Liquiline CM442 Total Chlorine Analysis System complete with Liquiline CM442 transmitter,
0.1 to 10 mg/L chlorine range
71464231 Liquiline CM444 Total Chlorine Analysis System complete with Liquiline CM444 transmitter,
0.1 to 10 mg/L chlorine range
71502873 Liquiline CM444 Total Chlorine Analysis System complete with Liquiline CM444 transmitter
with EtherNet/IP communications, 0.1 to 10 mg/L chlorine range
71464233 Expansion panel for installing additional disinfection sensors using an
existing system with CM444 transmitter (Sensor(s) and sensor cable(s) are
ordered separately.)

Note: Variations from these standard panels are available upon request. Disinfection systems with the Liquiline CM444 transmitter
allow for integration of up to eight additional sensor inputs. The CM444 configurations also allow for the integration of additional
I/O in the transmitter, such as digital communications or additional analog outputs. A system with a CM444 transmitter is required
to integrate the additional sensor(s) used with an expansion panel.
Consult your local Endress+Hauser sales representative to define a version tailored to a specific need.

www.addresses.endress.com
CP01262C/24/EN/02.20
(04.2020)
© Endress+Hauser, Inc., 2020