Abstract—This paper presents for the first time the between the two fingers is 5μm and 15μm (figure 1), and the
fabrication and testing of a PMMA capacitive micro dimensions of the folded-beams are 1040×10×60μm3
accelerometer based on hot embossing and ultra-precision (L×W×T). The size of the mass is 1.5mm×1.5mm. The gap
machining. The detection principle of the PMMA micro between device layer and the substrate is about 50μm.
accelerometer is based on closing-gap capacitive combs. 500µm
Since the sensor is made of PMMA polymer, it would be
very flexible, high sensitive and low cost. The PMMA 40µm
1.5mm
micro accelerometer was tested and very high sensitivity
of 0.4pF /G or equivalent to 0.16V/G/V was obtained. 1.5mm
I. INTRODUCTION
Silicon-based MEMS have been developing over the past
35 years with numerous successful commercializations of 60µm
silicon micro sensors, micro actuators in industrial and
consumer applications. However, Si is not the best choice for
all applications, especially for low cost devices. Recently, Schematic view of PMMA accelerometer
polymer MEMS have been studied extensively [1, 2] because
of several advantages against traditional silicon MEMS, such
as lower material, fabrication and assembly costs; most 5µm
polymers are flexible or softer than Si and, in many varieties, 5µm
they are transparent, biocompatible, and biodegradable, etc.
Since the Young's modulus and mass density of PMMA are 15µm
about 1/50 and 1/2 compared to those of Si, respectively, the
PMMA accelerometer should have a sensitivity of 25 times
higher than that of the silicon counterpart. In this work, at first
we will demonstrate the novel fabrication process for PMMA 100µm
MEMS structures, i.e. movable micro structures, based on hot
embossing and high precision machining (i.e. elliptical
vibration cutting method). Then, the development of a PMMA
capacitive micro accelerometer based on this process is Details of comb parts
presented.
Figure 1. Configuration of PMMA micro accelerometer.
II. DESIGN OF THE CAPACITIVE MICRO ACCELEROMETER
Configuration of the PMMA capacitive micro III. FABRICATION PROCESS OF THE MICRO
accelerometer is shown in figure 1.The micro accelerometer ACCELEROMETER
consists of a mass suspended by four beams. The mass can The fabrication process of the PMMA micro accelerometer
move laterally upon an application of acceleration, therefore, is shown schematically in figure 2.
the gaps of comb electrodes are changed, leading to the
change of capacitance. Capacitance change is then converted Firstly, two-stepped silicon mold was fabricated from
to output voltage through C-V converter circuit. Dimensions silicon wafer by ICP-RIE as shown in figure 3. Then the micro
of an electrode finger are 110×5×60μm3 (L×W×T), gap accelerometer structure was formed by hot embossing of
Si SiO2 Resist
(c) Bonding by surface activation method
Si PMMA Au
A. Fabrication of two-step Si mold Figure 4. SEM image of the two-stepped Si mold of the
The fabrication process of the two-step Si mold is shown accelerometer.
schematically in figure 3 [3]. Firstly, SiO2 layer is formed on
1302
Figure 5. SEM close-up image of the comb fingers illustrated Figure 6. SEM image of the PMMA micro accelerometer
in Fig. 4. structure after hot embossing process.
B. Hot Embossing and Bonding
The fabricated silicon molds are used for hot embossing
process. Micro accelerometer structures were hot embossed on
PMMA material. The entire hot embossing procedure and
condition parameters are as below:
REFERENCES
[1] S. Amaya, D.V. Dao, and S. Sugiyama, Proceedings of
MEMS 2009, pp 713- 716
[2] Chao-Heng Chien And Zhi-Peng Chen, Tech. Digest
APCOT2006, B-16.
[3] M. Mita, Y. Mita, H. Toshiyoshi, H. Fujita,” Multiple-
height Microstructures Fabricated by ICP-RIE and
Embedded Masking Layers”, T.IEE Japan, Vol. 120-E,
No.11, 2000, pp.493-497
[4] P. H. Pham et al, “Fabrication and Characterization of
Smooth Si Mold for Hot Embossing Process”, J.
Micromech. Microeng. Vol. 127 (2007), No. 3 pp.187-
191
Figure 9. Comb fingers of the PMMA micro accelerometer. [5] T. Suzuki, F. Kitagawa, H. Shinohara, J. Mizuno, K.
Otsuka and S. Shoji, “Polymer Microchip for
IV. OPERATIONAL TEST Electrophoresis-Mass Spectrometry Fabricated by Hot
The PMMA micro accelerometer was preliminarily Embossing and Low Temperature Direct Bonding”,
characterized by rotating it from 0o to 90o and the capacitance Tech. Digest Transducers’07, pp. 1617-1620.
change is measured. The output is shown in figure 10. [6] N. Suzuki, A. Nakamura, E. Shamoto, K. Harada, M.
Capacitance changes of 10% (or 0.4pF) were obtained when Matsuo, M. Osada, ” Ultraprecision micromachining of
accelerations of 1G are applied. hardened steel by applying ultrasonic elliptical vibration
cutting ” Proceedings of MHS 2003, pp 221- 226
12
10
8
ΔC/C (%)
0
0 15 30 45 60 75 90
Inclined angle (°)
Figure 10. Measurement result of capacitance
1304